Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

DEVICE RESET PROCEDURE CONTACT INPUTS & OUTPUTS

COM
① Insert a patch cable

AMG570 Interface Circuit


loop between ports Alarm & Contact

O
1 & 2 on the switch Outputs
Relay Output

COM
② Power cycle the (400V @ 0.1A Max)
switch

ALM
③ After switch boot

COM
cycle is complete Contact Input
remove the patch Dry Contact
cable loop (No Voltage)

I
Optical Isolation

POE CAPABILITIES
Example part code:
Ensure the PSU size
AMG570-2GBT-2GAT-2S-P240 used is at least equal
to the maximum PoE
budget figure.
Characters PoE Standard Supported Characters PoE Budget
None Non-PoE Model P120 120W Max IEEE 802.3at Models
Type 1 & 2 PoE support
AT IEEE 802.3at 30W Port P240 240W Max Mode A PSE only

AMG570
BT IEEE 802.3bt 60/90W Port
IEEE 802.3bt Models
Check the product label to determine the PoE power supported
on each port and the units total maximum PoE budget.
Type 1, 2, 3 & 4 PoE
support. Mode A AMG570-4G-2S Series
and/or Mode B PSE
L2+ Industrial Managed Switch
CONNECTING TO THE SWITCH
Web GUI
Installation Manual - Hardware
Default IP Address: 192.168.1.101
Username: admin
Password: admin

Console CLI
USB-A to USB-C Cable 115200,8,N,1

To access the full software user guide for this product


amg-support.com/AMG570-4G-2S_Series please visit the product page using the QR code
above or the direct link opposite.

AMG Systems Ltd. 3 The Omega Centre, Stratton Business Park, Biggleswade, Bedfordshire, SG18 8QB, UK
T :: +44 (0) 1767 600 777 E :: sales@amgsystems.com
D36187-00 www.amgsystems.com
Proud to be a British
Manufacturer amgsystems.com
AMG570-4G-2S INCLUDED ACCESSORIES DIN RAIL MOUNT INSTALLATION SURFACE MOUNT INSTALLATION

① Remove the DIN rail


clip by unscrewing the
two fixing screws as
shown.

USB Console Cable

DIN Rail Bracket

② Attach the included wall


mount brackets with the
AMG570 Switch provided 4 x M3 screws as
shown. ③ Fix the unit to the surface
using two appropriate screws
(screws not provided)
2 x Wall Mounting Brackets

POWER EARTH PROTECTION LED INDICATORS


Contact Out

Warning
Contact In
Alarm Out

Common

Check Polarity Before Powering


No Reverse Polarity Protection
Power Power
2 1
Model Type Voltage
Non-PoE Models 12-56 VDC
30W PoE Models 50-56 VDC
- + - +
90W PoE Models 52-56 VDC
LED Colour Description
DC input present on power 1
POWER 1 / 2 Blue
and/or power 2
ALARM Red Unit in alarm condition
SFP link present (flashes
SFP LINK/ACT Green
To provide correct protection from ESD with data traffic activity)
Model Type Power and Surge events ensure that the unit PoE is being delivered on
is correctly earthed using the provided POE 1-4 Yellow
All Models 6W Max* the port
earth connection point in accordance
*Excludes PoE Load with local electrical codes & standards. RJ45 LINK/ Ethernet link present (flashes
Green
(cable not provided) ACT with data traffic activity)