emek

emek
EMEK ELEKTRÝK ENDÜSTRÝSÝ A.Þ.
Address : Esenboða Yolu 23. Km 06750 Akyurt / ANKARA / TURKEY
Tel : +90 312 398 01 81 • Fax : +90 312 398 04 74
e-mail : emek@emek.com.tr
web site : www.emek.com.tr
Company Profile

Milestones

Oil Insulated Instrument Transformers


- Current Transformers
- Capacitive Voltage Transformers
- Inductive Voltage Transformers

Epoxy Resin Insulated Transformers


- Indoor Type Current and Voltage Transformers
- Outdoor Type Current and Voltage Transformers

Disconnecting Switches

Quality Assurance

Social Contributions

Contents
Company
Profile THE ART OF QUALITY FOR A HALF CENTURY IN
ALMOST 100 COUNTRIES
EMEK ELEKTRÝK ENDÜSTRÝSÝ A.Þ. aim to manufacture In 1978, EMEK commissioned her own research and
high quality and reliable products, taking both safety testing laboratory capable of performing all the routine
and environmental requirements into consideration. and type tests of instrument transformers (except the
EMEK quality for design and manufacturing, has been short time current test for current transformers). Later,
certified by both local and international institutes. a 5 meter high climatic room capable of going down to
EMEK has become a renowned world trademark for -45°C was added to the laboratory.
north america europe
delivery, quality and service. In 1982, EMEK realized the first export of instrument CANADA AUSTRIA
EMEK was established in 1969 as the first company of transformers, when 145 kV current and voltage COSTA RICA CROATIA MOLDOVA
CUBA DENMARK NORTHERN CYPRUS
BARMEK Holding and production began in a small transformers were exported to WAPDA, Pakistan. DOMINICAN REPUBLIC ESTONIA NORWAY
EL SALVADOR
workshop in Ankara. In 1994, EMEK was granted ISO 9001 certification by GUETAMALA
FRANCE PORTUGAL
GERMANY ROMANIA
EMEK signed a licence agreement with Balteau, the Turkish Standards Institute (TSE). Additionally, MEXICO GREECE RUSSIA
PANAMA HUNGARY SPAIN
Belgium in 1971 for the transfer of technology to EMEK was also accredited with ISO 9001 from TRINIDAD&TOBAGO IRELAND SWEDEN
manufacture oil filled current transformers and Independent International Institutes since 1997, ITALY SWITZERLAND
KOSOVA TURKEY
inductive voltage transformers up to 170 kV. The currently EMEK has ISO9001:2008 and 14001:2004 LUXEMBOURG UKRAINE
MALTA UNITED KINGDOM
agreement also included transfer of technology for cast certificates from ABS Quality Evaluations INC valid till
epoxy resin instrument transformers. 2012.
In 1972, EMEK moved to her new plant, 23 km from Emek has the annual capacity to manufacture 7500
downtown Ankara. Today, the plant comprises of units of oil filled and 35000 units of epoxy resin
11,500 m² covered area and 27,500 m² open area. instrument transformers, 2000 units of disconnecting
In 1975, EMEK signed another technology transfer switches and 1500 MVAR of power capacitors.
agreement with ICAR Italy, for manufacturing of asia
AZERBAIJAN
capacitive voltage transformers and LV power EMEK Manufacture; BANGLADESH
BRUNEI
capacitors. CAMBODIA
Instrument Transformers HONG KONG

•Oil filled current transformers up to 525 kV,


INDIA
INDONESIA
•Capacitive voltage transformers up to 525 kV, JAPAN
KRYGYZSTAN
• Oil filled inductive voltage transformers up to 420 kV, LAOS
MALAYSIA
MONGOLIA
MYANMAR
Epoxy
Epoxy Resin
Res Transformers africa NEPAL
• Indoor
ndoor type epoxy resin current and voltage
In EGYPT PAKISTAN
ETHIOPHIA middle east PHILIPPINES
transformers
transform up to 36 kV, south america GHANA IRAN SINGAPORE
KENYA IRAQ SOUTH KOREA
• Outdoor
Outdoo type epoxy resin current and voltage BRAZIL
LÝBYA
JORDAN
SRI LANKA
CHILE LEBANON
transformers
transform up to 36 kV, COLOMBIA MALI OMAN
PALESTINE
TAIWAN
ECUADOR MOROCCO TAJIKISTAN
QATAR
PERU MOZAMBIQUE SAUDI ARABIA THAILAND
Disconnecting
D iissconnec Switches VENEZUELA NIGERIA SYRIA
UNITED ARAP EMIRATES
oceania TURKMENISTAN
SOUTH AFRICA AUSTRALIA VIETNAM
YEMEN
•D Disconnecting
Di isconne switches up to 245 kV, TANZANIA FIJI
TUNISIA NEW ZEALAND
UGANDA PAPUA NEW GUINEA
ZAMBIA
Caaap
C
Cap paci
ac tors
ac
Capacitors ZIMBABWE
• Low
Lo
Lo
oww volt
voltage power capacitors

Tod
od
oda
day, EMEK
Today, EM products are exported almost 100
countries aall around the world.
countries
2/3
MILESTONES

Hüseyin Arabul and Özcan Kanburoðlu, the first graduates of


Middle East Technical University (METU) Electrical Engineering
Department, prepared their master thesis on "Design and
Production of 154 kV Current Transformers" and "Optimum
Economic Solutions" under joint cooperation of
ETIBANK and METU.

1965, the master project has been realized at ETIBANK


facilities.

1969 Hüseyin Arabul and Özcan Kanburoðlu


established EMEK Elektrik Endüstrisi A.Þ.
the first company of the group in a small
workshop with the financial support of
11 shareholders.

1971 EMEK made a license agreement with


BALTEAU (Belgium) for High and Medium
Voltage Instrument Transformers.
1980 License agreement with Merlin-Gerin
(France) for the production of
disconnecting switches up to 420 kV
and SF6 Circuit Breakers up to
1990 A joint venture company (GALMEK)
was established with Gec - Alsthom
( France ) for manufacturing of Sf6
Circuit Breakers up to 36 kV and
36 kV was signed. Cubicles.
First 170 kV voltage and current
transformers were manufactured.

1972 EMEK moved to a new campus


25 km away from downtown, along the
Esenboða Airport Road, with initially
1982 EMEK Holding was established.
In the same year, first export was realized.

First 420 kV Current and Capacitive


1994 Emek was granted ISO 9001
certification by the Turkish
Standards Institute (TSE)

2,500 m2 of closed area Voltage Transformers were manufactured. EMEK was also accredited with
ISO 9001 from Independent
International Institutes.

First production of 36 kV, Sf6 Circuit

1973 First production of MV Epoxy Resin


Instrument Transformers was realized. 1984 Breakers was realized under the
license of Merlin - Gerin. 1998 Initial public offering of 18% of EMEK
Elektrik’s shares was realized.

Concession Agreement for the transfer of


operation rights of the electricity distribution
network of Ankara - Kýrýkkale region was signed
with Ministry of Energy.

1975
Technical know-how agreement
with ICAR (Italy) for LV Power
Capacitors production was signed.
1985 First 170 kV Disconnecting Switch
was manufactured.
2006 Emek was granted ISO 14001
certificationby Independent
International Institutes.

1976
Technical know-how agreement with
ICAR for Capacitive Voltage
1988 As a result of the reorganization
studies, BARMEK Holding was
established.
2010 First production of 420 kV tank type
current transformers is realized.

Transformers production was signed.


4/5
OIL INSULATED
INSTRUMENT TRANSFORMERS

DESCRIPTION
Production
• EMEK current transformers are
manufactured in Ankara Turkey.
CURRENT General Description
TRANSFORMERS • We manufacture oil insulated current transformers up to
ϱϮϱ kV
• Above 170 kV, Cascade type transformers which include two or
UP TO ϱϮϱ KV three bushings is provided.
• Primary and secondary cores are housed in porcelain bushing
or tank.
• Transformers are hermetically sealed.
• Well proven “hair pin” technology is used.

REQUIRED TECHNICAL SPECIFICATIONS


ELECTRICAL DATA
.Service Conditions
.Insulation Level
.Frequency
.Number of Cores
.Current Ratio
.Rated Burden for Each Core
.Accuracy Class for Each Core
.Standards
.Continuous Primary Current
.Short time Thermal Current
.Creepage Distance

6/7
OIL INSULATED
DESIGN CHARACTERISTICS INSTRUMENT TRANSFORMERS

Frequency Cores Base Plate Altitude


• 50 Hz, 60 Hz • Grain oriented silicon steel is used. • Base of the transformers are fabricated from steel and • Standard design is suitable up to 1000 m above sea level.
• The core shapes are toroidal with or without air gap. galvanised.
Secondary Current • Electrolytic copper suitable to withstand rated continuous Optional Accessories
• 1 A, 2 A or 5 A, others on request. current and short time thermal current is used for primary Name Plate • Capacitive tap
winding. • Name plates are stainless steel and weatherproof. • Steel support structure
Primary Current • Enamelled electrolytic copper wire is used for • Primary connectors
• up to 4000 A Secondary winding. Secondary Terminal Box • Marshalling box
• Hinged type boxes are used and are sealable on request.
Thermal and Dynamic Ratings Bracelets They are made of aluminium or stainless steel. Maintenance
• Short time thermal current ratings up to 50 KA/ 3 sec and • All bracelets used on transformers are made from • Clamp type secondary terminals are used. Other secondary • Maintenance free, simple recommendations;
dynamic current ratings up to 125 KA peak. aluminium alloy. terminals are available on request. • Clean the porcelain bushing at regular
intervals depending on the degree of pollution.
Continuous Thermal Current Head Earthing • Ensure that there is no oil leakage.
• 1.2 x In continuous (up to 2.0 x In on request). • The housing head is fabricated from corrosion protected • Earthing terminals are located on the base of the
aluminium.
transformers. Spare Part & Special Tools
Insulation • Every housing is subject to pressure and vacuum test before
• Clamp type terminals are available on request. • There are no user serviceable parts, therefore
• Oil impregnated paper, high dielectric strength, low dielectric assembly.
no spare parts or special tools are required for maintenance.
losses.
• Graded layers with well rounded edges enable a uniformly
Assembly
distributed field over the whole unit.
• Before the assembly, following visual checks should be made;
Insulating Oil • There are no oil leaks,
• The insulating oil is mineral oil in conformity with IEC 60296. • The porcelain is not damaged,
• Before impregnation, moisture and gases are removed from • The aluminium protective cover on the bellows is not damaged,
the oil by special processes. CURRENT • There is no damage on the primary terminals,
• The oil level indicator indicates sufficient oil level.
• Drain plug for taking samples and oil refilling facilities are
provided on request.
• Floating type oil level indicator is standard supply.
TRANSFORME
TRANSFORMERS Packing

Oil Impregnation
UP TO ϱϮϱ KV • The transformers are packed in rugged wooden crates which are
suitable for overseas transportation.
• Heat and vacuum are applied to the fully insulated windings • The transformers are encapsulated in polyethylene covers to
after assembly of the current transformer for drying purposes, keep them from environmental effects.
followed immediately by the oil impregnation procedure. • Wooden crates can be lifted by either a fork lift or by a crane
with slings.
Hermetic Seal
• Oil volume variations are compensated with stainless steel
bellows placed in the head of the transformers. With this Painting
facility there will be no contact between air and oil in the • External surface of the transformers, which are already
transformers. corrosion protected, are additionally painted grey. Other
• The dielectric strength will remain unchanged for the life timee colours are available on request.
of the CT.
Earthquake Design
Bushings • Standard design is up to 0.6g.
• Brown, Grey glazed porcelain.
Mechanical Strength
Primary Terminals • Applied load to the primary terminal in horizontal and vertical
• Primary terminals are made from tin plated copper. is in conformity with IEC 60044.1 and IEC 60186.
• Vertical and horizontal primary terminals are available.
• Dimensions depend on rated primary current. Ambient Temperature
e.
• Stud, nema pad or clamp type primary terminals are available. • Standard design is suitable for temperature range -50 °C to
+50°C. Other ranges on request.
1-Aluminium Rain Cover 10-Secondary Widdings
2-Stainless Steel Bellows 11-Secondary Widdings Support
3-Oil Level indicator 12-Oil
4-Primary Terminals 13-Base Plate
5-Aluminium Head 14-Lifting Holes
6-Primary Widding 15-Secondary Terminals Never Use The Primary Terminals For Lifting The Transformer
7-Paper Insulation ( HVside) 16-Oil Sampling Valve Lift The Transformer By Using The Holes provided On The Base
8-Porcelain Bushing 17-Oil Filling Tap
9-Paper lnsulation(LV side) * Other technical specifications may be available
upon request. 8/9
OIL INSULATED
INSTRUMENT TRANSFORMERS

DESCRIPTION
Production
• EMEK capacitive voltage transformers are
manufactured in Ankara Turkey.
CAPACITIVE
VOLTAGE General Description
• We manufacture oil insulated capacitive voltage transformers
up to ϱϮϱ kV
TRANSFORMERS • CVTs are composed of two seperate part: capacitive voltage
divider and tank.
UP TO ϱϮϱ KV • Above 170 kV, Multiple bushings are supplied for capacitive
voltage divider part.
• Oil inside the tank and the capacitive voltage divider is different
and they do not mix with each other.
• Transformers are hermetically sealed.

REQUIRED TECHNICAL SPECIFICATIONS


ELECTRICAL DATA
.Service Conditions
.Insulation Level
.Frequency
.Number of Winding
.Voltage Ratio
.Rated Burden for Each Winding
.Accuracy Class for Each Winding
.Standards
.Rated Capacitance
.Creepage Distance

10/11
OIL INSULATED
DESIGN CHARACTERISTICS INSTRUMENT TRANSFORMERS

Frequency Magnetic Unit Oil Insulation Oil Impregnation


• 50 Hz, 60 Hz • The insulating oil is mineral oil in conformity with IEC 60296. • Heat and vacuum are applied after assembly of the
• Before impregnation, moisture and gases are removed from the capacitive unit for drying purposes, followed
Rated Secondary Voltage Description oil by special processes. immediately by oil impregnation procedure
• 110/√3, 100/√3, 110/3, 100/3, 100, 110 V etc. • The hot dip galvanised steel tank houses oil impregnated • Drain plug for taking samples and oil refilling facilities are
magnetic unit. provided on request. Bushings
in conformity with customer requirement.
• Floating type oil level indicator is standard supply. • Capacitor stacks are housed in porcelain
Paper Insulation bushings.
Highest System Voltage
• Oil impregnated paper is used which has high dielectric Accessories • Bushings are brown, grey glazed porcelain.
• Highest system voltage from 72.5 to ϱϮϱ KV.
strength, low dielectric losses. • Fixing holes, lifting holes, secondary terminal box, name plate,
Number of Secondary Windings warning plates are also provided in our standard design. Packing
Core • The transformers are packed in rugged
• In conformity with customer requirements, max. 4
• High quality sheet steel cores are used. Tank wooden crates which are suitable for overseas transportation.
secondary windings is available.
• Enamelled electrolytic copper wire is used for primary windings. • Tank is made from hot dip galvanised steel and painted with • The transformers are encapsulated in polyethylene covers to
• Enamelled electrolytic copper wire is used for secondary grey colour. keep them from environmental effects.
Voltage factor
windings. • The magnetic unit consists of the reactor (inductance • Wooden crates can be lifted by either a fork lift or by a crane
• 1.2 x Un continuous / 1.9 x Un for 30 sec.
coil), short circuit protection device, anti ferro resonance with slings.
Oil Impregnation filter and intermediate transformer.
Hermetic Seal
• Heat and vacuum are applied to the fully insulated windings Maintenance
• Oil volume variations are compensated with teflon bellows placed
after assembly of the magnetic unit for drying purposes. • Maintenance free, simple recommendations;
in the capacitive parts, for air not to contact oil
• The dielectric strength will remain unchanged for the life • Clean the porcelain bushing at regular
time of the CVT. intervals depending on the degree of pollution.
• Ensure that there is no oil leakage.
Primary Terminals
• Primary terminals are made of tin plated brass. CAPACITIVE Special Tools & Spare Parts
• Nema pad or clamp type primary terminals are available • No special tools, servicable parts or spare parts are required
on request. VOLTAGE for the maintenance.

Name Plate
• Name plates are stainless steel and weatherproof.
TRANSFORMERS
Painting
UP TO ϱϮϱ KV
• External surface of the transformers, which are already corrosion
protected, are additionally painted grey colour.

Earthquake Design
• Standard design is up to 0.6g. Secondary Terminal Box
• Hinged type boxes are used and are sealable on request.
Mechanical Strength • Secondary box consists of secondary terminals, spark gap,
• Applied load to the primary terminal in horizontal and vertical earthing switch, drain coil, low voltage terminal-HF terminal
is in conformity with IEC 60044.5 and IEC 60186. and earthing terminal.
• Secondary terminals are clamp type.
Ambient Temperature • Fuses or MCB’s are also available on request.
• Standard design is suitable for temperature range -20 °C to +40 °C.
Capacitive Unit
Altitude
• Standard design is suitable up to 1000 m above sea level.
Description
Tuning • The capacitor stacks in Emek CVT’s are the mixed type
• The CVT is tuned in the factory and sealed. No further tuning which means paper and plastic film are used together
on site is required. as the dielectric.
• Capacitor elements are stacked and bound together to
Bracelet maintain constant pressure.
• All bracelets used on transformers are made of aluminium alloy. • The electrodes are made of soft rolled aluminium.

Optional Accessories Oil Insulation


• Steel support structure • The insulating oil is synthetic oil.
• Primary connectors • Before impregnation, moisture and gases are removed from Lift The Transformer By Using The Holes provided On The Tank
• Marshalling box the oil by special process.
• If required mount line traps can be provided at order stage. * Other technical specifications may be available
upon request. 12/13
OIL INSULATED
INSTRUMENT TRANSFORMERS

DESCRIPTION
Production
• EMEK inductive voltage transformers are
INDUCTIVE manufactured in Ankara Turkey.

VOLTAGE General Description


• We manufacture oil insulated inductive voltage transformers
up to ϭϳϬ kV
TRANSFORMERS • Up to 36kV, IVTs are manufactured tank type, primary and
secondary windings are housed in galvanised stainless steel tank.
UP TO ϭϳϬ KV • From 36kV up to 170kV, IVTs are manufactured as bushing type,
primary and secondary windings are housed in porcelain bushing.
• Transformes are hermetically sealed.

REQUIRED TECHNICAL SPECIFICATIONS


ELECTRICAL DATA
.Service Conditions
.Insulation Level
.Frequency
.Number of Windings
.Voltage Ratio
.Rated Burden for Each Winding
.Accuracy Class for Each Winding
.Standards
.Voltage Rating Factor
.Creepage Distance

14/15
OIL INSULATED
DESIGN CHARACTERISTICS INSTRUMENT TRANSFORMERS

Frequency Secondary Terminal Box Altitude


• 50 Hz, 60 Hz • Hinged type boxes are used and are sealable on request. • Standard design is suitable up to 1000 m above sea level.

Rated Secondary Voltage Painting Bracelet


• 110/√3, 100/√3, 110/3, 100/3, 100, 110 V etc. • External surface of the transformers, which are already corrosion • All bracelets used on transformers are made of aluminium
in conformity with customer requirement. protected, are additionally painted grey colour. alloy.

Highest System Voltage Earthquake Design Optional Accessories


• Highest system voltage is ϭϳ0 KV. • Standard design is up to 0.6g. • Steel support structure
• Primary connectors
Number of Secondary Windings Mechanical Strength • Marshalling box
• In conformity with customer requirements, max. 4 • Applied load to the primary terminal in horizontal and vertical
secondary windings is available. is in conformity with IEC 60044.2 and IEC 60186. Assembly
• Before the assembly, following visual checks should be made;
Voltage factor Ambient Temperature • There are no oil leaks Special Tools & Spare Parts
• 1.2 x Un continuous / 1.9 x Un for 30 sec. • Standard design is suitable for temperature range • The porcelain is not damaged • No special tools, servicable parts or spare parts are required
-50 °C to +50 °C. • There is no damage on the primary terminals for the maintenance.
Hermetic Seal • The oil level indicator indicates sufficient oil level
• Oil volume variations are compensated with stainless steel
bellows placed in the head of the transformers.
• With this facility there will be no contact between air and oil.
• The dielectric strength will remain unchanged for the life time
of the VT.

Primary Terminals INDUCTIVE


• Primary terminals are made of tin plated brass.
• Vertical and horizontal primary terminals are available on request. VOLTAGE
Name Plate
• Name plates are stainless steel and weatherproof.
TRANSFORMERS
Paper Insulation UP TO ϭϳ0 KV
• Oil impregnated paper is used which has high dielectric strength
and low dielectric losses.

Core
• High quality sheet steel cores are used.
• Enamelled electrolytic copper wire is used for primary windings.

Bushing Packing
• Brown, grey glazed porcelain • The transformers are packed in rugged wooden crates which are
suitable for overseas transportation.
Oil Insulation • The transformers are encapsulated in polyethylene covers to
• The insulating oil is mineral oil in conformity with IEC 60296. keep them from environmental effects.
• Before impregnation, moisture and gases are removed from • Wooden crates can be lifted by either a fork lift or by a crane
the oil by special processes. with slings.
• Drain plug for taking samples and oil refilling facilities are
provided on request. Maintenance
• Floating type oil level indicator is standard supply. • Maintenance free, simple recommendations;
• Clean the porcelain bushing at regular intervals depending on
Oil Impregnation the degree of pollution.
• Heat and vacuum are applied to the fully insulated windings • Ensure that there is no oil leakage.
after assembly of the inductive voltage trasformers for drying
purposes, followed immediately by oil impregnation procedure.
Lift The Transformer By Using The Holes provided On The Base
Accessories
• Fixing holes, lifting holes, secondary terminal box, name plate,
warning plates are also provided in our standard design.

* Other technical specifications may be available


upon request. 16/17
EPOXY RESIN INSULATED
TRANSFORMERS

Secondary Terminal Box


• The secondary terminals are provided with a
transparent covering.
• If CT’s are used for revenue metering
provision can be made to seal the covers.

Earthing
• Earthing terminal is located
on the body of the transformers.

Ambient Temperature
• Standard design is suitable for temperature
range -25°C to +40°C.

Maintenance
• Maintenance free, our simple recommendations are;
• Cleaning of the body to eliminate deposits of all type of pollution.

Special Tools & Spare Parts


• No special tools, no servicable parts or spare parts are required.

Packing
• The transformers are packed in rugged wooden crates which are
suitable for overseas transportation.
• The transformers are encapsulated in polyethylene covers to keep
INDOOR TYPE them from environmental effects.

CURRENT Assembly
• Before the assembly, following visual checks should be made;
DESCRIPTION TRANSFORMERS • Ensure that there is no crack on the body
Production • Ensure that the body is clean
• EMEK indoor type epoxy resin insulated current transformers are • Ensure that there is no damage on the base and secondary
manufactured in Ankara Turkey. terminal box.
• Current transformers can be assembled in any position.
General Description
• We manufacture indoor type epoxy resin insulated current transformers
up to 36 kV DESIGN CHARACTERISTICS
• Primary and secondary cores are moulded in epoxy resin to Epoxy Resin
ensure product with high reliability, maintenance free, • The cores and windings of the current transformer are
small weight, mounting in any position, high mechanical strength. moulded in epoxy resin.
• Vacuum is applied during material preparation and
the casting processes.

Primary Terminals
REQUIRED TECHNICAL SPECIFICATIONS • Primary terminals are made of tin plated brass or copper.
• Stud, nema pad or clamp type primary terminals are available.
ELECTRICAL DATA
Cores
.Service Conditions
• Grain oriented silicon steel is used.
.Insulation Level
• The core shapes are toroidal without air gap.
.Frequency
• Electrolytic copper strips suitable to withstand rated
.Number of Cores continuous current and short time thermal current is used for
.Current Ratio primary winding
.Rated Burden for Each Core • Enamelled electrolytic copper wire is used for secondary
.Accuracy Class for Each Core winding.
.Standards
.Continuous Primary Current Base Plate
.Short Time Thermal Current • Base of the transformers are fabricated from sheet steel
and are hot dip galvanised. * Other technical specifications may be available
upon request. 18/19
EPOXY RESIN INSULATED
TRANSFORMERS

Primary Terminals
• Primary terminals are made of tin plated brass.

Core
• High quality sheet steel cores are used.
• Enamelled electrolytic copper wire is used
for primary windings.
• Enamelled electrolytic copper wire is used
for secondary windings.

Base Plate
• Base of the transformers are fabricated from Aluminium

Secondary Terminal Box


• The secondary terminals are provided with a transparent covering.
• If VT’s are used for revenue metering provision can be made to
seal the cover.

Earthing
• Earthing terminal is located on the body of the transformers

Ambient Temperature
Standard design is suitable for temperature range -25°C to +40°C.

Maintenance
INDOOR TYPE • Maintenance free, our simple recommendations are;
• Cleaning of the body to eliminate deposits of all type of pollution.
VOLTAGE
Special Tools & Spare Parts
DESCRIPTION TRANSFORMERS • No special tools, no servicable parts or spare parts are required.
Production
• EMEK indoor type epoxy resin insulated voltage transformers are Packing
manufactured in Ankara Turkey. • The transformers are packed in rugged wooden crates which are
suitable for overseas transportation.
General Description • The transformers are encapsulated in polyethylene covers to keep
• We manufacture indoor type epoxy resin insulated voltage transformers them from environmental effects.
up to 36 kV DESIGN CHARACTERISTICS Assembly
• Primary and secondary windings are moulded in epoxy resin to
ensure product with high reliability, maintenance free, Frequency • Before the assembly, following visual checks should be made;
• 50 Hz, 60 Hz • Ensure that there is no crack on the body
small weight, mounting in any position, high mechanical strength.
• Ensure that the body is clean
Rated Secondary Voltage • Ensure that there is no damage on the base and secondary
• 110/√3, 100/√3, 110/3, 100/3 V etc. in conformity with terminal box.
customer requirement. • Voltage transformers can be assembled in any position

REQUIRED TECHNICAL SPECIFICATIONS Highest System Voltage


• Highest system voltage is 36 KV.
ELECTRICAL DATA
.Service Conditions Number of Secondary Windings
.Insulation Level • In conformity with customer requirements, max. 3
.Frequency secondary windings is available.
.Number of Windings
.Voltage Ratio Voltage factor
.Rated Burden for Each Winding • Phase to Ground Connection : 1.2 x Un continuous / 1.9 x Un
.Accuracy Class for Each Winding for 30 sec.
.Standards • Phase to Phase Connection : 1.2 x Un continuous.
.Voltage Rating Factor
Epoxy Resin
• Vacuum is applied during material preparation and
casting processes. * Other technical specifications may be available
upon request. 20/21
EPOXY RESIN INSULATED
DESCRIPTION DESIGN CHARACTERISTICS TRANSFORMERS
Production
• EMEK outdoor type epoxy resin insulated current transformers are
manufactured in Ankara Turkey.
Frequency Primary Terminals
General Description 50 Hz, 60 Hz • Primary terminals are made of tin plated brass or copper.
• We manufacture outdoor type epoxy resin insulated current • Stud, nema pad or clamp type primary
transformers up to 36 kV Secondary Current terminals are available.
• Primary and secondary cores are moulded in epoxy resin to 1 A, 2 A or 5 A, others on request.
ensure product with high reliability, maintenance free, Cores
small weight, mounting in any position, high mechanical strength. Primary Current • Grain oriented silicon steel is used.
• Up to 3000 A • The core shapes are toroidal without air gap.
• Electrolytic strips copper suitable to
Thermal and Dynamic Ratings withstand rated continuous current and short
• Short time thermal current up to 40 KA/ 3 sec and dynamic time thermal current is used for primary
REQUIRED TECHNICAL SPECIFICATIONS current ratings up to 100 KA peak are possible. windings.
• Enamelled electrolytic copper wire is used for secondary windings.
ELECTRICAL DATA Continuous Thermal Current
.Service Conditions • 1.2 x In continuous, higher values on request. Base Plate
.Insulation Level • Base of the transformers are fabricated from Aluminium
.Frequency Epoxy Resin
• Vacuum is applied during material preparation and Name Plate
.Number of Cores
casting processes. • Name plates are stainless steel and weatherproof.
.Current Ratio
.Rated Burden for Each Core
Secondary Terminal Box
.Accuracy Class for Each Core
• The secondary terminals box is polypropylene (also cover)
.Standards
or epoxy with aluminium cover.
.Continuous Primary Current
• If CT’s are used for revenue metering provision can be made
.Short Time Thermal Current
to seal the covers.
.Creepage Distance OUTDOOR TYPE
Earthing
CURRENT • Earthing terminal is located on the body of the transformers.

TRANSFORMERS Ambient Temperature


• Standard design is suitable for temperature range -25°C to +40°C.

Altitude
• Standard design is suitable up to 1000 m above sea level.

Maintenance
• Maintenance free, our simple recommendations are;
• Cleaning of body to eliminate deposits of all type of pollution.

Special Tools & Spare Parts


• No special tools, no servicable parts or spare parts are required.

Packing
• The transformers are packed in rugged wooden crates which are
suitable for overseas transportation.
• The transformers are encapsulated in polyethylene covers to keep
them from environmental effects.

Assembly
• Before the assembly, following visual checks should be made;
• Ensure that there is no crack on the body
• Ensure that the body is clean
• Ensure that there is no damage on the base and secondary
terminal box.
• Current transformers can be assembled in any position

* Other technical specifications may be available


upon request. 22/23
EPOXY RESIN INSULATED
DESCRIPTION DESIGN CHARACTERISTICS TRANSFORMERS
Production
• EMEK outdoor epoxy resin insulated voltage transformers are
manufactured in Ankara Turkey. Frequency Earthing
• 50 Hz, 60 Hz • Earthing terminal is located on the body of the transformers.
General Description
• We manufacture outdoor type epoxy resin insulated voltage transformers Rated Secondary Voltage Ambient Temperature
up to 36 kV • 110/√3, 100/√3, 110/3, 100/3 V etc. in conformity with • Standard design is suitable for temperature
• Primary and secondary windings are moulded in epoxy resin to customer requirement. range -25°C to +40°C.
ensure product with high reliability, maintenance free,
small weight, mounting in any position, high mechanical strength. Highest System Voltage Maintenance
• Highest system voltage is 36 KV. • Maintenance free, our simple
recommendations are;
Number of Secondary Windings • Cleaning of the body to eliminate deposits
• In conformity with customer requirements, max. 3 of all type of pollution.
REQUIRED TECHNICAL SPECIFICATIONS secondary windings is available.
Special Tools & Spare Parts
ELECTRICAL DATA Voltage factor • No special tools, no servicable parts or spare parts are required.
.Service Conditions • Phase to Ground Connection : 1.2 x Un continuous / 1.9 x Un
.Insulation Level for 30 sec. Packing
.Frequency • Phase to Phase Connection : 1.2 x Un continuous • The transformers are packed in rugged wooden crates which are
.Number of Windings suitable for overseas transportation.
.Voltage Ratio • The transformers are encapsulated in polyethylene covers to keep
.Rated Burden for Each Winding them from environmental effects.
.Accuracy Class for Each Winding
.Standards Assembly
.Voltage Rating Factor • Before the assembly, following visual checks should be made;
.Creepage Distance • Ensure that there is no crack on the body
• Ensure that the body is clean
OUTDOOR TYPE • Ensure that there is no damage on the base and secondary
terminal box.
VOLTAGE • Voltage transformers can be assembled in any position
TRANSFORMERS

Epoxy Resin
• Whole cores and windings of the voltage transformer
are moulded with the epoxy resin.
• Vacuum is applied during material preparation and
casting processes.

Primary Terminals
• Primary terminals are made of tin plated brass.

Core
• High quality sheet steel cores are used.
• Enamelled electrolytic copper wire is used for primary
windings.
• Enamelled electrolytic copper wire is used for secondary
windings.

Base Plate
• Base of the transformers are fabricated from Aluminium

Secondary Terminal Box


vering
• The secondary terminals are provided with a transparent covering.
• If VT’s are used for revenue metering provision can be made to
seal the cover.
* Other technical specifications may be available
upon request. 24/25
DISCONNECTING SWITCHES

DESCRIPTION
Production
• EMEK disconnecting switches are manufactured in
CENTER BREAK Ankara Turkey.

HORIZONTAL General Description


• We manufacture disconnecting switches up to 245 kV
• Center Break, horizontal opening type disconnecting switches
OPENING are available.
• Motor or manual operating mechanism can be supplied upon
UP TO 245 KV request.

REQUIRED TECHNICAL SPECIFICATIONS


ELECTRICAL DATA
.Service Conditions
.Insulation Level
.Frequency
.Rated Current
.Short Time Thermal Current
.Standard
.Creepage Distance
.With or Without Earthing Switch
.Motor or Manual Operating Mechanism
.Motor Control Voltage

26/27
DESIGN CHARACTERISTICS DISCONNECTING SWITCHES

Frequency Control Cubicle


• 50Hz, 60Hz • The control cubicle is fabricated from high grade stainless
steel to prevent corrosion.
Rated Current • Painting or similar maintenance is not required during
• Up to 2500A the switchgear lifetime.
• The control cubicle contains a thermostat controlled
Shot time Thermal Current heater to prevent condensation.
• Short time thermal current up to 40kA / 3 second is available. • Breathing vents are fitted with brass screen mesh to
• Under fault conditions contact pressure increases, providing prevent insect entry.
excellent short-time current withstand capability.
Bearing
Number of Poles • The bearings, which carry the major mechanical load of the
• One or three poles are available disconnectors, are made from stainless steel and Teflon (PTFE)
• Each pole contains a frame, two rotating post insulators and components.
two main contacts that move in the horizontal plane. • Bearings are closed to the environment and do not require
maintenance.
Ambient Temperature • The post insulators are mounted on rotating bearings, which
• Standard design is suitable for temperature range -25 °C to 40 °C are mounted on the U beam frame.

Altitude
• Standard design is suitable up to 1000m above sea level.

Main Contacts
• Silver plated contacts are used to provide excellent resistance
to environmental pollutants.
CENTER BREAK
• Finger type contacts ensure auto alignment during the closing
operation. HORIZONTAL
• The pressure on the contacts in closed position is adecuate for
keeping the temperature rise within limits. OPENING
• The main contacts rotate 90 degrees to open and close
the disconnector. UP TO 245 KV
Operating Mechanism
• Motor and manual operating mechanism are available.

Control Mechanism Characteristics


• It is not possible to engage remote and local control at the Auxillary Contacts
rated voltage kV 36 72.5 123 145 170 245
same time. • Auxiliary contacts are procured from well known
• The universal joint between the gear box and the rotating manufacturers who have specialized and are experienced insulation withstand level(kV)

mechanism ensures silent and safe operation. in this type or switches. to earth 70 140 230 275 325 460
one-min.power frequency, wet
(rms value)
Motor Packing across isolating distance 80 160 265 315 375 530
• The motors can be AC or DC upon request and can run • The disconnecting switches are packed in ruggen wooden
to earth 170 325 550 650 750 1050
between 85% and 110% of rated voltage. crates which are suitable for overseas transportation. lightning impulse 1.2/50 uS
(peak value)
• Manual operation is possible only after mechanical and electrical • Insulators and active parts are packed separately in two across isolating distance 190 375 630 750 860 1200
interlocks are in effect, thus accidental motor operation during different boxes.
hand operation is impossible. 800
• Motors can be controlled remotely, or locally, with the push Assembly 1250
rated normal
buttons located within the control cubicle. • Before the assembly, following visual checks should be made; currents(A)
1600
• Ensure that there is no crack on the body
Earthing Switches • Ensure that the body is clean 2500
• In case required one or two earthing switches can be supplied. • Ensure that there is no damage on the base and secondary kA rms 1250 A 31.5 31.5 31.5 31.5 31.5 31.5
• Motor and manual operating mechanism can be provided. terminal box. short time kA rms 1600-2000 A 40 40 40 40 40 40
withstand current
• Motors may be AC or DC type. kA peak 1250 A 80 80 80 80 80 80
kA peak 1600-2500 A 100 100 100 100 100 100

short time withstand current can be extended to 40kA upon request.

* Other technical specifications may be available


upon request. 28/29
QUALITY ASSURANCE

QUALITY POLICY

We will do the real customer satisfaction by supplying faultless


products with convenient price and delivery at the right time.
After sales service will be supplied along the service life.
To reach this aim, we believe that it is necessary;

• To adapt customer requests and expectations at changing market


conditions by taking into consideration environmental impacts
• To improve quality and profitability continually.
• To get superiority to rival companies by cost reducing.
• To supply staffs participation, training and satisfaction.

Standards
• All products are subjected to full routine tests as
described in the relevant standards.
• Type tests can also be performed (except short time current test)
in our own testing laboratories but should be negotiated
during the order stage.
• IEC, BS, ANSI, AS, CSA and other standards on request.

Testing facilities
• Type and routine tests as described in IEC, ANSI, AS, BS, CSA etc. are carried
out (except short time current test for CT’s) at the testing facilities of EMEK, located
in Ankara.
• Testing facilities include apparatus and systems for testing dry and wet
insulation (power frequency & impulse), partial discharge, accuracy, power factor & loss
angle, RIV, artificial ageing and mechanical strength.
• Operation tests of our climatic chamber under severe ice condition and at the
temperature limit -40 / +150 °C are possible.
• Test facilities for transformer oil and insulation paper are also available.
• Tests can be performed between 16 2/3 to 60 Hz.
• Temperature and humidity controlled calibration center is available.

Test Reports
• Despite Emek's testing facilities, our products have also been tested at several
Certificates • Independent Testing Laboratories such as ; KEMA, CESI, VEIKI, ICMET, STRI, IPH...etc
EMEK was granted ISO 9001 certification by the Turkish Standards Institute (TSE). • Upon customer request, we have performed more than 150 Type Tests for our products.
Additionally, EMEK was also accredited with ISO 9001 from Independent Institutes
since 1997. Currently EMEK has ISO 9001:2008 and ISO 14001:2004 certificates from
ABS Quality Evaluations Inc.

30/31
EMEK, being aware of her social responsibilities, has
Social Contributions participated in the foundation of Kusadasi Education and
Development Foundation under BARMEK Group, Private
U. Naci Akdogan Schools in 1993 and opened BARMEK
The Chairman and the executive staff of EMEK Primary School in Ankara, Balikhisar Village for the
ELEKTRÝK ENDÜSTRÝSÝ A.Þ. is active in the energy sector 1997-1998 education year to give support to the eight
both in Turkey and in the world not only through their years of continuous education campaign in Turkey.
positions as the founder and/or member of the local and Believing in the necessity of equal education opportunity.
international non-governmental organizations, but also EMEK also gives support to other schools and foundations,
presented reports and scientific studies. contributes, the education of many successful students and
offers them career opportunities.
The World Energy Council, of which Hüseyin ARABUL, the
chairman of EMEK, is the Deputy President and Turkey In The Years Of Two Thousand Strategically, Social
President of Turkish National Committee, makes studies And Economical Research Foundation (FOUNDATION 2000),
for reliable and effective generation, transmission and leaded by BARMEK Group, EMEK aims to make strategic
distribution of energy and environmental friendly studies and to give consultancy services for Turkey to take her
utilization of the energy resources. Additionally, the deserved place among the developed countries, to reach
Committee discusses the problems, future energy policies a higher level of prosperity and consciousness, for equality
and energy resources of Turkey by organizing congresses, in country management and practice of every element
symposiums, conferences, public sessions and panels and of human rights and democracy. The foundation also
offers solutions. organizes many activities to represent our country in the
international arena effectively.
BARMEK Group has also played an active role in the
foundation of many non-governmental organizations In addition, EMEK frequently brings together
like Electromechanical Industrialists' Association (EMSAD), her employees, by organizing nee planting festivals,
Electricity Distribution Firms' Association (ELDER), tennis tournaments, art markets, concerts and picnics.
Defense Industry Manufacturers' Association (SASAD).
Electric Industry Businessmen's Association (ELSIAD), On 23th April international Children Festival
Middle East Technical University Development Foundation. and the painting contest among the primary school
Prof. Dr. M. Parlar Foundation and Metal Goods Industry students organized in 2000. EMEK continues to increase
Employers' Union (MESIS). EMEK has right to change the information and datas without prior notice
her dedications for children of our future.
All updated datas can be reached from our web site www.emek.com.tr
All rights reserved.