Date : May 2024

No. : CCE-3088

Technical Report
CCE-3088

ROM UPGRADE..... (16)

Caution for firmware upgrade


・If upgrading from the version 0310Q100_23120400 or earlier you won’t be able to restore original version.
・0330Q100_24041000 is the common firmware for BP-50C26 etc. and BP-50M26 etc. and BP-FR12U.

1. Model Name: BP-50C26/26A/31/31A/36/45/55/65,


BP-70C31/31A/36/45/45A/55/65/65A, BP-50M26/26A/31/31A/36/45/55/65,
BP-70M31/31A/36/45/45A/55/55A/65/65A,
BP-FR12U (Option for BP-50C26/26A/31/31A/36/45/55/65,
BP-70C31/C31A/36/45/45A/55/65/65A, BP-50M26/M26A/31/31A/36/45/55/65,
BP-70M31/31A/36/45/45A/55/55A/65/65A)

2. Description: Upgrade of ICU, PCU and PCU_BW-ROM


From May 2024 production.
ROM
Model BUNDLE ICU PCU PCU_BW SCU
Control No.
BP-50C26, BP-50C31
BP-50C36, BP-50C45
BP-50C55, BP-50C65
BP-55C26, BP-60C31
C06 0330Q100 -
BP-60C36, BP-60C45
BP-70C31, BP-70C36
BP-70C45, BP-70C55
0330Q100_ 0330Q100
BP-70C65 0200Q100
24041000
BP-50M26, BP-50M31
BP-50M36, BP-50M45
BP-50M55, BP-50M65
B06 - 0330q100
BP-70M31, BP-70M36
BP-70M45, BP-70M55
BP-70M65
BP-FR12U - 0330Qc00 0330Q100 0330q100
- Last 8-digit of BUNDLE version is displayed when updating the firmware
Notification
in the field. Factory default is fixed to 00000000.

Item of change - See page 2.

1/2
SHARP CORPORATION Smart Work Solutions Business Unit C
ROM Version History Table
ROM
No. BUNDLE ICU PCU PCU_BW SCU Action T/R No.
Control No.
C05 0320Q100_ Feb.2024
(15) 0320Q100 CCE-3044
B05 24012200 Mar.2024
0310Q100 0310q100
C04 0310Q100_
(14) 0310Q100 Jan.2024 CCE-3035
B04 23120400
C03 0303Q100_ Aug.2023
(13) 0303Q100 0200Q100 CCE-2985
B03 23080300 Sep.2023
C01 0301Q100_
(12) 0301Q100 0300Q100 0300q100 Jul.2023 CCE-2968R
B01 23061400
C00 0300Q100_
(11) 0300Q100 Jun.2023 CCE-2940R2
B00 23051700
B08 0286Q100_
(10) 0286Q100 Apr.2023 CCE-2910
A07 23031500
B07 0285Q100_
0280Q100 0285Q100 0280q100 Mar.2023 CCE-2893R3
A06 23030600
(9)
0280Q100_
A05 - Mar.2023 CCE-2893
23021500
B05 0270Q100_
0270Q100 Feb.2023
A04 23011300
(8) 0231Q100 0200q100 CCE-2868
B04 0260Q100_
0260Q100 Jan.2023
A03 00000000
(7) B03 0250Q100_ CCE-2786R
0250Q100 0230Q100 0130q100 Oct.2022
(2) A02 22092600 ARE-1439R
0211Q100_
(1) A01 0210Q100 - 0101q100 0100Q100 Aug.2022 ARE-1427
22080800
0202Q100_
(6) B02 0202Q100 0202Q100 Jul.2022 CCE-2739
22070600
0201Q100_
(5) B01 0201Q10a Jun.2022 CCE-2720
22060700
0200Q100
0200Q100_
(4) B00 0200Q10a May.2022 CCE-2709
22052400
-
0121Q100_
(3) A04 0121Q100 May.2022 CCE-2682
22042100
0120Q10a
0120Q10a_
(2) A03 0120Q100 Apr. 2022 CCE-2658R
22031700
0101Q100_ 0100Q10c
(1) A01 0100Q100 Feb. 2022 CCE-2633
22021000

Item of change
No. Item Detail

Support for change of Gmail connector.


*Google has released an interface to connect with Gmail (mail service provided by Google). Since they
1 OSA
announced to change some terms of use, “Gmail connector” cannot be used after mid-April of this year
affected by the change.

Main unit Correction of occasional failure to execute remote firmware update. It occurred if LAN cable is not
2
control connected while checking for an update (which takes place in every 24 hours).

(Only for MFPs with 120V AC supply voltage)


When more than 300 sheets are printed under following conditions, power cooling fan does not work,
causing DC power supply failure (short circuit of diode).
Main unit
3 - Desk and finisher are installed.
control
- Temperature 15 °C or higher.
- Humidity 80% or lower.
- First job after recovering from power off (or sleep) which lasted 40 minutes or longer.

Correction of occasional failure to detect A6R size paper as Extra size.


Main unit
4 The error occurred if you go to [System Settings] > [Common Settings] > [Paper Settings] > [Paper Tray
control
Settings] and tap [Submit] without changing any setting for Bypass tray.

Correction of occasional failure to login after swiping an HID card when switched to Job Status screen
while displaying OSA screen and then switched back to original screen.
5 OSA
It occurred while using an OSA external authentication application which allows login using key emulation
by HID card while IC card authentication is disabled.