Professional Documents
Culture Documents
119 ST Andrews Avenue-Proposed Roof Structure-S01
119 ST Andrews Avenue-Proposed Roof Structure-S01
119 ST Andrews Avenue-Proposed Roof Structure-S01
T1 T1
TIMBER SCHEDULE
PRR1
T2 T2 T2 T2
T1 T1
14
15
FRJ1 (FLAT ROOF JOISTS) 50*150 C24 @400 C/C
16
TRIMMER T1 DOUBLE 50*175 C24 TIMBER
C1 17 18 19 20 21 22 23 24 25 B1
P1 TRIMMER T2 DOUBLE 50*175 C24 TIMBER
FRJ1
ALL MASONRY BLOCKWORK TO BE 7.3N GRADE. M6/ (ii) MORTAR.
DW
EXISTING STRUCTURAL ELEMENTS THROUGHOUT THE DURATION OF THE PROPOSED WORKS. *Do not scale from this drawing. *This layout and the information
contained within is the property IAW
ENSURE GAP BETWEEN NEW STEEL BEAMS AND EXISTING MASONRY IS PACKED TIGHT. SOME COSMETIC CRACKING MAY OCCUR AFTER TEMPORARY PROPPING IS TAKEN AWAY AS THE BEAM DEFLECTS SLIGHTLY UNDER *All dimensions, levels and setting Consulting Engineers and may not be
outs to be checked on site. used, transmitted or reproduced
THE NEW LOADING. MAKE GOOD ANY CRACKING. in whole or in part without prior written
*This layout should be used in
consternation from IAW Consulting
ANY WALLS THAT ARE SUPPORTING STEELWORK THAT ARE FOUND NOT TO BE LOAD BEARING MASONRY OR OF POOR CONSTRUCTION SHOULD BE REPORTED TO THE ENGINEER. conjunction with other the
Engineers.
documentation of the same revision.
ADEQUATE TEMPORARY WORKS ARRANGEMENT MUST BE INTRODUCED PRIOR TO DEMOLITION AND CONSTRUCTION WORKS BEGIN.
ALL STEEL BEAMS WHERE SEATED ON MASONRY TO HAVE CONCRETE PADSTONES BENEATH BEAM ENDS. PADSTONES BASED ON ENGINEERING CALCULATION AND TO MATCH WIDTH OF WALL. CONCRETE TO ALL PAD
STONES TO HAVE A MINIMUM STRENGTH OF 30 N/MM2. STEEL BEAMS TO HAVE A MINIMUM END BEARING OF 150MM WHERE SPAN OF BEAM IS PARALLEL TO WALL UNLESS NOTED OTHERWISE ON THE DETAILS. I A Waseem
BE, MSc, CEng MICE
STEELWORK TO BE MILD STEEL GRADE S275, WIRE BRUSHED TO REMOVE ALL OIL, RUST, MILL SCALE ETC. AND PAINTED WITH TWO COATS OF ZINC PHOSPHATE OR SIMILAR APPROVED. CONSULTING ENGINEERS
NEW STEEL BEAMS TO BE ENCASED IN 12.5MM GYPROC FIRELINE BOARD WITH STAGGERED JOINTS, GYPROC FIRECASE OR PAINTED IN NULLIFIRE S OR SIMILAR INTUMESCENT PAINT TO PROVIDE 1/2 HOUR FIRE RESISTANCE
Project: Drawing Title:
AS AGREED WITH BUILDING CONTROL. ALL FIRE PROTECTION TO BE INSTALLED AS DETAILED BY SPECIALIST MANUFACTURER.
ALL STEEL WORK CONNECTIONS TO HAVE 4 NO. M16(8.8)BOLTS. UNO.
BEAM B1 TO COLUMN C1 CONNECTIONS TO BE AS PER DETAIL 03 119 ST ANDREWS PROPOSED ROOF
AVENUE STRUCTURE