6-134-4 Piping Arrangements For Venturi Installations
6-134-4 Piping Arrangements For Venturi Installations
DATE 11JAN16
SSI
STATUS REAFFIRMED
K
VENTURI INLET PIPING ARRANGEMENTS FOR VENTURI INSTALLATIONS SPONSOR RED
TTEN PERM I
H APPROVED MJM
F
S W RI
VALVE
A Z
THOUT UOP'
D
FLOW
GLOBE, LESS
TWO CONTROL, THAN
PLANE
SCLOSED TO OTHERS W I
OR CHECK 10D
10D OR
FLOW VALVE
GREATER
CONCENTRIC
REDUCER
CATED,OR DI
TEE,
CROSS, OR
CONCENTRIC
LATERAL
REDUCER OR
EXPANDER GATE OR
BALL VALVE
NOMINAL
PIPE LENGTH OF STRAIGHT RUN
DIAMETER
A F G H K Z
D
3D 3.5D 4.5D 20D 29.5D 4D
3" 9" (230) 1 (270) 1'- (345) 5'-0" (1525) 7'-6" (2290) 1'-0" (305)
4" 1'-0" (305) 1'-2" (360) 1'-6" (460) 6'-8" (2035) 10'-0" (3050) 1'-4" (410)
6" 1'-6" (460) 1'-9" (540) 2'-3" (690) 10'-0" (3050) 15'-0" (4575) 2'-0" (610)
8" 2'-0" (610) 2'-4" (715) 3'-0" (915) 13'-4" (4065) 20'-0" (6100) 2'-8" (815)
DENTI
10" 2'-6" (765) 2'-11" (890) 3'-9" (1145) 16'-8" (5080) 25'-0" (7620) 3'-4" (1020)
12" 3'-0" (915) 3'-6" (1070) 4'-6" (1375) 20'-0" (6100) 30'-0" (9145) 4'-0" (1220)
S CONFI
14" 3'-6" (1070) 4'-1" (1245) 5'-3" (1605) 23'-4" (7115) 35'-0" (10670) 4'-8" (1425)
S DOCUM ENT I
16" 4'-0" (1220) 4'-8" (1425) 6'-0" (1830) 26'-8" (8130) 40'-0" (12195) 5'-4" (1630)
18" 4'-6" (1375) 5'-3" (1605) 6'-9" (2060) 30'-0" (9145) 45'-0" (13720) 6'-0" (1830)
20" 5'-0" (1525) 5'-10" (1780) 7'-6" (2290) 33'-4" (10160) 50'-0" (15240) 6'-8" (2035)
24" 6'-0" (1830) 7'-0" (2135) 9'-0" (2745) 40'-0" (12195) 60'-0" (18290) 8'-0" (2440)
N THI
ON I
NFORM ATI
NOTES:
1. TABULATED DIMENSIONS ARE BASED ON INFORMATION IN THE INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO) 5167-1 AND ALSO
AL -THE I
AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME), FLUID METERS - 6th EDITION, AT A MAXIMUM THROAT DIAMETER RATIO (d/D) OF 0.75.
2. DIMENSIONS SHOWN ARE THE MINIMUM REQUIRED. WHEN POSSIBLE THEY SHOULD BE INCREASED.
3. WHEN SEVERAL FITTINGS (OTHER THAN 90° BENDS) ARE UPSTREAM OF THE VENTURI, THE FIRST FITTING CLOSEST TO THE VENTURI SHALL BE PER THE TABLE. THE
DENTI
MINIMUM STRAIGHT LENGTH FROM THE SECOND FITTING (TO THE FIRST FITTING) SHALL BE • OF THE DIMENSION LISTED IN THE TABLE FOR THE SECOND FITT
CONFI
4. WHEN BENDS ARE USED INSTEAD OF FITTINGS TO CHANGE DIRECTION, DIMENSION LINES SHALL BE TO TANGENT LINE OF BEND.