Professional Documents
Culture Documents
Ground Floor and Second Floor Lighting Layout (Typical) : A B C D E
Ground Floor and Second Floor Lighting Layout (Typical) : A B C D E
ELECTRICAL SYMBOLS:
CEILING LIGHT REFER TO SCHEDULE
E E A E EC CA E
OUTLET
F MANUAL CALL POINT FOR FIRE ALARM
12000 OF LIGHTING
FIXTURES AND LAMPS VIBRATING BELL OUTLET, 230mm
CEILING LIGHT B DIAMETER, 230V, 60HZ TO BE INSTALLED 1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF THE LATEST
3000 3000 3000 3000 OUTLET @ 300mm BELOW CEILING LINE
EDITION OF THE PHILIPPINE ELECTRICAL CODE, EXISTING APPLICABLE ORDINANCES, RULES AND
Sa SINGLE POLE WALL SWITCH IN ONE
1
CEILING MOUNTED EXHAUST FAN (15
SWITCH PLATE (10 AMP., 230 VOLTS)
AMP., 230 VOLTS) REGULATIONS OF THE LOCAL GOVERNMENT AND WITH THE REQUIREMENTS OF THE LOCAL
2 SINGLE POLE WALL SWITCHES IN ONE
Sab SWITCH PLATE (10 AMP., 230 VOLTS) CONCEALED OR EMBEDDED CONDUIT POWER COMPANY.
RUN
LAUNDRY AND LAUNDRY AND LAUNDRY AND LAUNDRY AND 3 SINGLE POLE WALL SWITCHES IN ONE
CR DIRTY KITCHEN CR DIRTY KITCHEN CR DIRTY KITCHEN CR DIRTY KITCHEN Sabc SWITCH PLATE (10 AMP., 230 VOLTS)
CONCEALED OR EMBEDDED CONDUIT
RUN TO SWITCHES 2. THE TYPE OF SERVICE POWER SUPPLY TO BE USED SHALL BE SINGLE-PHASE, 2-WIRE, 230V, 60
HERTZ, A.C
3000
Sg Sh Sg Sh Sg Sh Sg Sh 3w CIRCUIT HOMERUN
S THREE WAY SWITCH
a
a
AIRCON OUTLET DISTRIBUTION PANELBOARD
3. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF SERVICE ENTRANCE
DUPLEX UNIVERSAL CONVENIENCE OUTLET,
FOR CONNECTION TO THE POWER COMPANY SERVICE POINT.
DINING
DINING
DINING
DINING
AREA M ELECTRIC SERVICE METER
AREA
AREA
AREA
Sdef Sdef Sdef Sdef GROUNDING TYPE, "WP" DENOTES
b
EL SINGLE CONVENIENCE OUTLET w/ 3W (2x1.5W),
220lm LED EMERGENCY LIGHT, ADJUSTABLE 4. UNLESS OTHERWISE SPECIFIED, THE MINIMUM SIZES OF WIRE AND GALVANIZED RIGID STEEL
EL EL EL EL GROUNDING SYSTEM
LAMP HEADS ON SINGLE PRONG OUTLET
c b c b c b c b
CONDUIT TO BE USED SHALL BE 3.5mm²,THHN AND 15mm NOMINAL DIAMETER, RESPECTIVELY.
LIKEWISE ALL ELECTRICAL WIRES SHALL BE COLOR-CODED.
BEDROOM BEDROOM
3000
5. ALL LIGHTING CIRCUIT HOMERUNS AND CONVENIENCE OUTLETS SHALL BE WIRED WITH NOT LESS
SCHEDULE OF LIGHTING FIXTURES AND LAMPS:
a b b b b THAN 3.5 mm² IN SIZE.
BEDROOM BEDROOM 12W LED Round Panel Downlight, Diecast Aluminum, Powder
Coated, (Daylight) RECESSED MOUNTED
PB1A PB1B PB1C PB1D
a a HALLWAY
a a
18W LED Square Panel Downlight, Diecast Aluminum, Powder
Coated, (Daylight) SURFACE MOUNTED
7. ALL NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE PROPERLY
350
OPEN SPACE/PARKING AREA 15W LED Square Panel Downlight, Outdoor Type, IP20, (Daylight)
SURFACE MOUNTED GROUNDED IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE.
GROUND FLOOR AND SECOND FLOOR 8. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND OF THE APPROVED TYPE FOR LOCATION
AND PURPOSE.
LIGHTING LAYOUT(TYPICAL) 9. STANDARD TYPE OF ACCESSORIES, SPLICING DEVICES, TERMINATIONS AND OTHER
THIS SITE APPURTENANCES FOR THE ENTIRE ELECTRICAL INSTALLATION SHALL BE USED.
A B C D E COURT
10. ALL WALL OUTLETS SHALL BE INSTALLED AT THE FOLLOWING HEIGHTS ABOVE THE FINISHED
FLOOR LEVEL UNLESS NOTED IN THE PLAN.
3000 3000 3000 3000 11. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE SUPERVISION OF A
DULY REGISTERED ELECTRICAL ENGINEER.
NATIONAL HIGHWAY
1
LAUNDRY AND LAUNDRY AND LAUNDRY AND LAUNDRY AND
CR DIRTY KITCHEN CR DIRTY KITCHEN CR DIRTY KITCHEN CR DIRTY KITCHEN
CSU CANTEEN
3000
CSU CARIG
DINING
DINING
DINING
DINING
AREA
AREA
AREA
AREA
2 BEDROOM BEDROOM
3000
TO CARIG HIGHWAY
TO REGIONAL OFFICES
BEDROOM
PB1A PB1B PB1C PB1D
1650
HALLWAY
3
VICINITY MAP
350
PTR. No. :
PROPOSED 2-STOREY COMMERCIAL BUILDING
CELENE HELOISE C. MIGUEL E-1
PRC. REG. No.
OWNER
PLACE ISSUED : DATE ISSUED : LOCATION: CARIG, TUGUEGARAO CITY , CAGAYAN ELECTRICAL