SEPLOS 419.12KWh Energy Storage Battery Solution
SEPLOS 419.12KWh Energy Storage Battery Solution
12kWh Energy
Storage Technical Solution
VERSION:V1.0
TIME:2023 年 3 月
The energy storage system consists of 419.12KWh batteries and PCS inverters.
The topology of the energy storage system is shown in the figure below:
The battery module is composed of 18 square aluminum shell cells 18S, and the
module lugs are connected by laser welding.It adopts air-cooled heat dissipation
method and has a BMU module.
management unit BCMU, and a battery stack management unit BAMU.The BMS
system has the functions of high-precision detection and reporting of analog signals,
fault alarm, upload and storage, battery protection, parameter setting, passive
mode to interact with other modules in the system to control the operation of the
system.
NO Item description Specification parameter
Equipment
1 model BMU
Equipment
2 12 way detection
Specification
Detection
12 way
quantity
Detection
±1℃
accuracy
resolution ≤1℃
Temperature
≤2s
upload cycle
Detection
12 way
quantity
Detection
±0.2%
accuracy
4 Voltage test
sampling period 50ms
Detection range 0VDC~5VDC
Voltage upload
≤2s
cycle
5 Balance type Passive balance
6 Balance current Passive balance 100mA
7 Communication CAN2.0
Dongguan Seplos Technology Co., Ltd 5
interface
8 Supply Voltage 24VDC
Equipment power
9 ≤2W
consumption
The BCMU is responsible for managing all the BMU in a battery rack. At the same time, it is
equipped with the total voltage collection of the battery cluster, the cluster current collection,
and the leakage detection. When the state of the battery module is abnormal, it will drive to
disconnect the high-voltage contactor, so that the battery rack will be out of operation, ensuring
The battery is safe to use.At the same time, capacity calibration and SOC calibration are
completed independently under the management of BMS. Through its own algorithm, the latest
corrected battery system capacity and SOC calibration value are obtained.
detection accuracy
9 Communication interface
RS485*2、CAN*3、Ethernet
3 Current Acquisition
≤±0.2%
Accuracy
4 SOC calculation
≤5%
accuracy
6 Energy Calculation
≤±2%
Error
7 Record ≥10000
13 Communication
RS485*3,CAN*2,Ethernet/100M
interface
14 Supply voltage 24VDC
15 Equipment power ≤3W
consumption
2 Balanced 100mA
current
3 MOS
configuration External MOS
method
4 Balanced
Interface Comes with TVS protection
protection
Compared with the built-in MOS solution, the external MOS equalization solution
can better protect the FAE interface and prevent the FAE from being damaged by
static electricity, hot-swapping impact, etc.The external MOS is also more conducive
to heat dissipation, reducing the risk of FAE heating, improving the stability of FAE,
and improving the balance efficiency.
The energy storage cabinet is equipped with industrial air-conditioning for heat
dissipation, and the unique air duct design realizes precise heat dissipation.The
Large air volume design to meet the small temperature difference requirements for
The fire protection system of this energy storage project includes the following
systems:
integrated inside the battery container(The entire gas fire extinguishing system has
three starting modes: automatic control, manual control and mechanical emergency
operation.)
b) Fire alarm detection system
For electrical and battery fires in the energy storage battery compartment, configure
sensitive fire detection systems with different principles, including smoke detectors
and temperature detectors. At the same time, auxiliary criteria for electrical
quantities are added to form linkage with automatic gas fire extinguishing equipment,
so as to Find the source of the fire and rush to the fire in time.It forms a linkage with
The energy storage container is equipped with a high-definition network camera for
round-the-clock monitoring and video recording of the environment and equipment
operation inside the container, and transmits the dynamic image of the monitored
target to the monitoring center.
The energy storage system of this project uses a rated power of 250kW energy
storage battery and the AC grid, including AC/DC bidirectional converter power
bidirectional converter has the function of parallel and off-grid operation, which can
guarantee the continuous power supply of important loads; it can cooperate with the
DC voltage 900Vdc
100KW
AC Rated output power
Dongguan Seplos Technology Co., Ltd 10
characteristics
Maximum output power 100KVA
220
Allowable grid voltage(Vac)
(-15%~15%)
50Hz
Rate
230@380VAC
Maximum output current
maximum efficiency
97.3%
overload capacity
110%
-20~50℃
Working temperature Range
700×220×440
Dimension
35Kg
Weight
environment
3000m(3000m
Altitude
Derating)
cooling method
air cooled
IP20
IP grade
In this project, the energy management system (EMS) adopts centralized control, and
the energy management system is responsible for system real-time data acquisition
and monitoring (SCADA), data storage, classification, query, system charge and
discharge scheduling, system protection control, etc., to realize automatic intelligent
control of the system , and can communicate with the remote information
management system to realize remote operation and maintenance.
map, color-coded operation nodes and a clear control interface, which can perform
EMS has a rich database to collect and process system operation data.It has the
functions of event sequence recording and accident recall, and can self-diagnose and
self-recovery for software failures.It also has advanced control strategies for plan
Heptafluoropropane
set
automatic monitoring fire 1
Confluence cable,
connection cable
1 set communication cable