A330 ECAM Warning Reset Guide
A330 ECAM Warning Reset Guide
CAB PR
CAB PR AFT OFV NOT OPEN. NO DISPATCH
- Check forward outflow Valve OPEN.
CAB PR EXCESS CABIN ALT. Not applicable
- Reset breakers CPC 1 and CPC 2 on LH and RH reset panels
CAB PR FWD OFV NOT OPEN. NO DISPATCH
- Check aft outflow Valve OPEN.
CAB PR LDG ELEV FAULT MEL 21-31-05
- Reset breakers CPC 1 and CPC 2 on LH and RH reset panels.
- Reset breaker, DMC 3 on RH reset panel.
CAB PR LO DIFF PR Not applicable
- No Action required.
CAB PR SAFETY VALVE OPEN MEL 21-31-05
- If safety valves are visually closed.
- Reset breakers SDAC 1 and 2 on LH and RH reset panels.
CAB PR SYS 1 + 2 FAULT MEL 21-31-05
- Reset breakers CPC 1 and 2 on LH and RH reset panels.
CAB PR SYS 1 FAULT MEL 21-31-05
- Reset breaker CPC 1 on LH reset panel.
CAB PR SYS 2 FAULT MEL 21-31-05
- Reset breaker CPC 2 on RH reset panel.
COND
COND AFT CRG ISOL FAULT MEL 21-28-03-B
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND AFT CRG VENT FAULT MEL 21-28-03-A
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND BULK CRG DUCT OVHT MEL 21-43-02
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND BULK CRG HEAT FAULT MEL 21-43-02
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND BULK CRG ISOL FAULT MEL 21-28-04-B
- Reset breaker VENT CONT Lane1/2 on RH reset panel.
COND BULK CRG VENT FAULT MEL 21-28-04-A
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND L + R CAB VENT FAULT MEL 21-21-01
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND L CAB VENT FAULT MEL 21-21-01
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND LAV + GALLEY FAN FAULT MEL 21-23-01
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND R CAB VENT FAULT MEL 21-21-01
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND VENT SYS FAULT MEL 21-26-04
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND ZONE CTLR FAULT MEL 21-63-01
- Reset breaker ZONE CONT on RH reset panel.
COND ZONE CTLR 2 FAULT MEL 21-63-01
- Reset breaker ZONE CONT on RH reset panel.
COND ZONE REGUL FAULT MEL 21-63-01 or 21-63-03
- Reset breaker ZONE CONT on RH reset panel.
COND CAB REST ISOL FAULT MEL 21-21-04
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND DUCT OVHT MEL 21-63-03 or 21-43-01
- Reset breaker ZONE CONT on RH reset panel.
COND FWD CRG COOL FAULT MEL 21-28-02-D
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND FWD CRG HEAT FAULT MEL 21-43-01
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND FWD CRG ISOL FAULT MEL 21-28-02-B
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
COND FWD CRG VENT FAULT MEL 21-28-02-A
- Reset breaker VENT CONT Lane 1/2 on RH reset panel.
VENT
VENT BLOWING FAULT MEL 21-21-02 or 21-26-08-A
- Reset breaker AEVC on LH reset panel.
VENT EXTRACT FAULT MEL 21-26-01
- Reset breaker AEVC on LH reset panel.
VENT GND COOL FAULT MEL 21-27
- Reset breaker AEVC on LH reset panel.
VENT OVBD VALVE FAULT MEL 21-26-02
- Reset breaker AEVC on LH reset panel.
VENT PACK BAY VENT FAULT MEL 21-25
- Reset breaker AEVC on LH reset panel.
AIR
AIR ABNORM BLEED CONFIG MEL 36-11-01
- Operational message… No further action required.
AIR APU BLEED FAULT MEL 36-12-02
- Perform BITE Test of BMC 1 & 2 on MCDU (ATA36)
AIR APU BLEED LEAK MEL 36-12-01 or 36-22-03
- Perform BITE Test of BMC 1 & 2 on MCDU (ATA36)
AIR BLEED LO TEMP MEL 36-11-01
- Perform BITE Test of BMC 1 & 2 on MCDU (ATA36)
AIR BMC 1 + 2 FAULT MEL 36-11-01
- Perform BITE Test of BMC 1 & 2 on MCDU (ATA36)
AIR BMC 3 + 4 FAULT MEL 36-11-01
- Perform BITE Test of BMC 3 & 4 on MCDU (ATA36)
AIR BMC 1 (2) (3) (4) FAULT MEL 36-11-01
- Perform BITE Test of BMC 1 (2) (3) (4) on MCDU (ATA36)
AIR ENG 1 (2) (3) (4) BLEED FAULT MEL 36-11-01
- Perform BITE Test of BMC 1 (2) (3) (4) on MCDU (ATA36)
AIR ENG 1 (2) (3) (4) BLEED LEAK NO DISPATCH or MEL 36-22-
01
- Perform BITE Test of BMC 1 (2) (3) (4) on MCDU (ATA36)
AIR ENG 1 (2) (3) (4) BLEED NOT CLSD MEL 36-11-02
- Perform BITE Test of BMC 1 (2) (3) (4) on MCDU (ATA36)
AIR ENG 1 (2) (3) (4) HPV NOT OPEN MEL 36-11-07
- Perform BITE Test of BMC 1 (2) (3) (4) on MCDU (ATA36)
AIR HOT AIR SYS 1 (2) FAULT MEL 21-63-03
- Perform System Test of the Temp CTL system on MCDU (ATA21)
AIR L WING LEAK NO DISPATCH or MEL 36-22-
02
- Perform BITE Test of BMC 1 & 2 on MCDU (ATA36)
- Switch ON/OFF ENG 1 Bleed
AIR L WING LEAK DET FAULT MEL 36-22-02
- Perform BITE Test of BMC 1 & 2 on MCDU (ATA36)
AIR PACK 1 + 2 FAULT MEL 21-52-01
- Check push button switch PACKS 1 & 2 ON.
- Passenger doors not closed and locked?
AIR PACK 1 OFF MEL 21-52-01
- Check push button switch PACK 1 ON.
AIR PACK 1 OVHT MEL 21-52-01
- Perform System Test of the Temp CTL system on MCDU (ATA21)
- Faulty Pack Controller 1 (531HH)
AIR PACK 1 REGUL FAULT MEL 21-52 or 21-53
- Perform System Test of the Temp CTL system on MCDU (ATA21)
- Faulty Pack Controller 1 (531HH)
AIR PACK 2 OFF MEL 21-52-01
- Check push button switch PACK 2 ON.
AIR PACK VALVE 1 FAULT MEL 21-52-01
- Faulty Pack Controller 1 (531HH)
AIR PACK VALVE 2 FAULT MEL 21-52-01
- Faulty Pack Controller 2 (532HH)
AIR CONTINUED
AUTO FLT
AUTO FLT A/THR LIMITED Not Applicable
- Operational message… No further action required.
AUTO FLT A/THR OFF MEL 22-30-01
- Reset breaker FMGEC 1 on LH reset panel.
- Reset breaker FMGEC 2 on RH reset panel.
AUTO FLT AP OFF MEL 22-10-01
- Reset breaker FMGEC 1 on LH reset panel.
- Reset breaker FMGEC 2 on RH reset panel.
- Recycle FCPC1,2 and 3 (Flight Control Primary Computer)
AUTO FLT FCU FAULT NO DISPATCH
- Reset breaker FMGEC 1 on LH reset panel.
- Reset breaker FMGEC 2 on RH reset panel.
- Reset breaker FCU 1 on LH reset panel.
- Reset breaker FCU 2 on RH reset panel.
AUTO FLT FM 1 + 2 FAULT MEL 22-83-01
- Reset breaker FMGEC 1 on LH reset panel.
- Reset breaker FMGEC 2 on RH reset panel.
AUTO FLT FM 1 FAULT MEL 22-72-01
- Reset breaker FMGEC 1 on LH reset panel.
AUTO FLT FM 2 FAULT MEL 22-72-01
- Reset breaker FMGEC 2 on RH reset panel.
AUTO FLT REAC W/S DET FAULT MEL 22-60-02-B
- Perform System Test of the Auto Flight System on MCDU (ATA22)
COM
COM ACARS FAULT MEL 23-24-01
- Perform BITE Test of ACARS on MCDU (COM-Radio)
COM ACARS ALERT Not Applicable
- If no message on PFR… No Action Required.
COM ACARS CALL Not Applicable
- If no message on PFR… No Action Required.
COM CIDS 1 + 2 FAULT MEL 23-73-01-A
- Reset breakers CIDS 1, CIDS 2 and DMC 3 on reset panels LH and
RH.
COM CIDS PA FAULT MEL 23-31-01
- Perform interface and Power Up test as follows:
- Open CB’s CIDS DIR 1 and DIR 2 ESS on panel 742VU
- Open CB’s CIDS DIR 1 and DIR 2 NORM on panel 722VU
- Close all breakers again.
COM HF 1 EMMITTING NO DISPATCH
- Reset breaker 2RE1 on panel 721VU
COM HF 2 EMMITTING NO DISPATCH
- Reset breaker 2RE2 on panel 722VU
COM VHF 1 EMMITTING NO DISPATCH
- Reset breaker 2RC1 on panel 742VU
COM VHF 2 EMMITTING NO DISPATCH
- Reset breaker 2RC2 on panel 722VU
COM VHF 3 EMMITTING NO DISPATCH
- Reset breaker 2RC3 on panel 721VU
ELEC
ELEC AC BUS 1-1 FAULT NO DISPATCH
- On panel 721VU cycle breakers M09, N11, Q05 and N07.
- On panel 722VU cycle breakers M39, L45 and M43.
- On panel 742VU cycle breakers A78, J77, E79 and H77.
ELEC AC BUS 1-2 FAULT NO DISPATCH
- On panel 721VU cycle breakers M09, N11, Q05 and N07.
- On panel 722VU cycle breakers M39, L45 and M43.
- On panel 742VU cycle breakers A78, J77, E79 and H77.
ELEC AC BUS 2-3 FAULT NO DISPATCH
- On panel 721VU cycle breakers M09, N11, Q05 and N07.
- On panel 722VU cycle breakers M39, L45 and M43.
- On panel 742VU cycle breakers A78, J77, E79 and H77.
ELEC AC BUS 2-4 FAULT NO DISPATCH
- On panel 721VU cycle breakers M09, N11, Q05 and N07.
- On panel 722VU cycle breakers M39, L45 and M43.
- On panel 742VU cycle breakers A78, J77, E79 and H77.
ELEC AC ESS BUS ALTN NO DISPATCH
- Perform operational test of the ESS generation manual switching.
- Open CB 1XC on panel 715VU.
- Release AC ESS FEED pushbutton.
- Close CB 1XC on panel 715VU.
- Push the AC ESS FEED pushbutton.
- Perform operational test of the ESS generation automatic switching.
- Open CB 41XN and 5XC on panel 721VU
- Close CB 41XN and 5XC on panel 721VU
ELEC AC ESS BUS FAULT NO DISPATCH
- Cycle CB 17XH on panel 742VU.
- Cycle CB 12XH on panel 742VU.
ELEC AC ESS BUS SHED NO DISPATCH
- Cycle CB 8XH on panel 742VU.
- Cycle CB 15XH on panel 742VU.
- Cycle CB 17XH on panel 742VU.
ELEC APU BAT FAULT MEL 24-38-01-A
- Switch APU Battery OFF.
ELEC APU BAT OFF MEL 24-38-01-A
- Operational message… No further action required.
ELEC APU BCL FAULT MEL 24-38-01-B
- Switch APU Battery OFF.
ELEC APU GEN FAULT MEL 24-23-01
- Perform APU GCU BITE test on MCDU (ATA 24-AC-EPGS)
ELEC APU GEN OVERLOAD MEL 24-26-01
- Perform EMCU BITE test on MCDU (ATA 24-AC-EMCU)
ELEC APU TR FAULT MEL 24-32-01
- Perform APU TR Reset on APU TR or through MCDU (ATA 24)
ELEC BAT 1 FAULT MEL 24-38-01-A
- Switch BAT 1 OFF then ON.
ELEC CONTINUED
ELEC CONTINUED
APU FIRE
APU FIRE NO DISPATCH
- Perform BITE test of the APU fire and overheat detector unit. (ATA
26)
SMOKE
SMOKE AFT CRG BTL 1 FAULT MEL 26-23-01
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE AFT CRG BTL 2 FAULT MEL 26-23-01
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE AFT CRG DET FAULT MEL 26-16-02
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE AFT/BULK CRG SMOKE NO DISPATCH
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
- If no real smoke in bulk or in the Air conditioning system,
Perform BITE test of Smoke Detection System with MCDU (ATA 26)
SMOKE AVIONICS DET FAULT NO DISPATCH
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE AVNCS VENT SMOKE NO DISPATCH
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
- If no real smoke in bulk or in the Air conditioning system,
Perform BITE test of Smoke Detection System with MCDU (ATA 26)
SMOKE BULK CRG DET FAULT MEL 26-16-03
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE CAB REST DET FAULT MEL 26-18-02
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE CAB REST SMOKE NO DISPATCH
- Check for real smoke in Cabin Attendant Rest Room.
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE DET FAULT NO DISPATCH
- Reset breakers SIDS 1 and 2 on LH and RH reset panel.
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE FLT REST DET FAULT MEL 26-18-01
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE FLT REST SMOKE NO DISPATCH
- Check for real smoke in Flight Crew Rest Room.
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE FWD CRG BTL 1 FAULT MEL 26-23-01
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE FWD CRG BTL 2 FAULT MEL 26-23-01
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE FWD CRG DET FAULT MEL 26-16-01
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE FWD CRG SMOKE NO DISPATCH
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
- If no real smoke in bulk or in the Air conditioning system,
Perform BITE test of Smoke Detection System with MCDU (ATA 26)
SMOKE LAVATORY DET FAULT MEL 26-17-01
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
SMOKE LAVATORY SMOKE NO DISPATCH
- Reset breakers SDCU 1 and 2 on LH and RH reset panel.
- If no real smoke in bulk or in the Air conditioning system,
Perform BITE test of Smoke Detection System with MCDU (ATA 26)
F/CTL
F/CTL ADR DISAGREE NO DISPATCH
- Check PFR.
F/CTL AIL SERVO FAULT MEL 27-14-01
- Cycle FCPC 2 (Flight Control Primary Computer).
F/CTL ALTN LAW NO DISPATCH
- Cycle FCPC 1 & 2 (Flight Control Primary Computer).
- Cycle FCSC 1 & 2 (Flight Control Secondary Computer).
F/CTL DIRECT LAW NO DISPATCH
- Check PFR.
F/CTL ELEV REDUND LOST NO DISPATCH
- Perform BITE test of the EFCS ground scanning through MCDU (ATA
27).
F/CTL ELEV SERVO FAULT MEL 27-43-01
- Perform BITE test of the EFCS ground scanning through MCDU (ATA
27).
F/CTL FCFC 1 FAULT MEL 27-95-01
- Reset FCDC 1 on LH reset panel.
F/CTL FCDC 1 + 2 FAULT MEL 27-95-01
- Reset FCFC 1 and 2 on LH and RH reset panels.
F/CTL FCDC 2 FAULT MEL 27-95-01
- Reset FCDC 2 on RH reset panel.
F/CTL FLAP SYS 1 FAULT MEL 27-51-01
- Cycle breakers SFCC 1 NORM on 721VU position X14.
- Cycle breakers SFCC 1 AVAIL on 721VU position X13.
- Cycle breakers SFCC 1 SLAT on 742VU position L62.
- Cycle breakers SFCC 1 FLAP on 742VU position L61.
F/CTL FLAP SYS 2 FAULT MEL 27-51-01
- Cycle breakers SFCC 2 SLAT on 722VU position T43.
- Cycle breakers SFCC 2 FLAP on 722VU position V40.
F/CTL FLAP TIP BRK FAULT NO DISPATCH
- Reset Wing tip Brake with MCDU (ATA 27)
F/CTL FLAP/MCDU DISAGREE NO DISPATCH
- Check the PFR.
F/CTL FLAPS FAULT NO DISPATCH
- Reset Wing tip Brake with MCDU (ATA 27)
F/CTL FLAPS LOCKED NO DISPATCH
- Reset Wing tip Brake with MCDU (ATA 27)
F/CTL GND SPLR FAULT MEL 27-92-02 or 32-42-05
- Cycle FCPC 1, 2 and 3 (Flight Control Primary Computers)
F/CTL IR DISAGREE NO DISPATCH
- Check the PFR.
F/CTL L ELEV FAULT NO DISPATCH
- Perform BITE test of EFCS ground scanning with MCDU (ATA 27).
F/CTL L INR AIL FAULT NO DISPATCH
- Perform BITE test of EFCS ground scanning with MCDU (ATA 27).
F/CTL L OUTR AIL FAULT NO DISPATCH
- Perform BITE test of EFCS ground scanning with MCDU (ATA 27).
F/CTL CONTINUED
F/CTL CONTINUED
F/CTL CONTINUED
FUEL
FUEL ABNORMAL MAN FWD XFR Not Applicable
- No Action Required.
FUEL APU AFT PUMP FAULT MEL 49-30-01-A
- Reset breakers FCMC 1 and 2 on LH and RH reset panel.
FUEL APU LP VALVE FAULT MEL 49-30-03
- Reset breakers FCMC 1 and 2 on LH and RH reset panel.
FUEL CTR TO INNER FAULT MEL 49-30-03
- Reset breakers FCMC 2 on RH reset panel.
FUEL ENG1 LP VALVE FAULT MEL 28-24-01
- Reset breakers FWC 1 and 2 on LH and RH reset panel.
FUEL ENG2 LP VALVE FAULT MEL 28-24-01
- Reset breakers FWC 1 and 2 on LH and RH reset panel.
FUEL ENG3 LP VALVE FAULT MEL 28-24-01
- Reset breakers FWC 1 and 2 on LH and RH reset panel.
FUEL ENG4 LP VALVE FAULT MEL 28-24-01
- Reset breakers FWC 1 and 2 on LH and RH reset panel.
FUEL EXCESS AFT CG MEL 28-40-13-A
- Reset breakers FCMC 1 and 2 on LH and RH reset panel.
FUEL FCMC 1 FAULT MEL 28-51-01-A or 28-51-01-B
- Reset breakers FCMC 1 on LH reset panel.
FUEL FCMC 1 + 2 FAULT NO DISPATCH
- Reset breakers FCMC 1 and 2 on LH and RH reset panel.
FUEL FCMC 2 FAULT MEL 28-51-01-A or 28-51-01-B
- Reset breakers FCMC 2 on RH reset panel.
FUEL FUEL LO TEMP MEL 28-49-02-A, -B OR -C
- Reset breakers FCMC 1 and 2 on LH and RH reset panel.
FUEL JETTISON FAULT MEL 28-31-02
- Reset breakers FCMC 1 and 2 on LH and RH reset panel.
FUEL JETTISON NOT CLOSED MEL 28-31-01
- Reset breakers FCMC 1 and 2 on LH and RH reset panel.
FUEL L CTR PUMP LO PR MEL 28-26-02
- Reset breakers FCMC 1 and 2 on LH and RH reset panel.
FUEL R CTR PUMP LO PR MEL 28-26-01
- Reset breakers FCMC 1 and 2 on LH and RH reset panel.
FUEL L INNER TK HI TEMP Not Applicable
- Apply ECAM procedure.
- If MCDU shows no maintenance message, no further action is
required.
FUEL L WING PUMPS LO PR MEL 28-21-01-A or 28-21-01-B
- Reset breakers FCMC 1 and 2 on LH and RH reset panel.
FUEL L WING TK LO LVL MEL 28-46-04-A
- Check the PFR.
- Operational message… No further action required.
FUEL L + R WING TK LO LVL MEL 28-46-04-A
- Check the PFR.
- Operational message… No further action required.
FUEL PUMP 1 LO PR MEL 28-21-01-A
- Cycle breaker FUEL PUMP 1 on 742VU pos S66.
FUEL CONTINUED
HYD
HYD B + Y SYS LO PR MEL 29-30-03-F
- Check Hydraulic fluid levels.
HYD B ELEC PUMP FAULT MEL 29-22-01 or 29-30-03-D
- Cycle breaker HSMU B + PART G on 721VU pos U11.
- Cycle breaker HYD PUMP B CTL on 721VU pos X12.
HYD B ENG 2 PUMP LO PR MEL 29-30-03-E
- Check BLUE Hydraulic fluid level.
- Bleed BLUE Hydraulic system.
HYD B RSVR LO AIR PR MEL 29-30-03-B
- Check Air pressure in reservoir from reservoir gauge.
- Pressurize the hydraulic reservoirs with APU Bleed air.
(Selection of ENG MASTER SW to crank will boost APU Bleed PX to
58 PSI for 30 sec).
HYD B RSVR LO LVL MEL 29-30-03-A
- Check BLUE hydraulic fluid level.
HYD G + B SYS LO PR MEL 29-30-03-F
- Check hydraulic fluid levels.
HYD G + Y SYS LO PR MEL 29-30-03-F
- Check hydraulic fluid levels.
HYD G ELEC PUMP FAULT MEL 29-21-01 or 29-30-0-D
- Cycle breaker HSMU B + PART G on 721VU pos U11.
- Cycle breaker HSMU Y + PART G on 722VU pos X46.
HYD G ENG 1 PUMP LO PR MEL 29-30-03-E
- Check GREEN hydraulic fluid level.
- Bleed GREEN hydraulic system.
HYD G ENG 1 + 4 PUMPS LO PR MEL 29-30-03-E
- Check GREEN hydraulic fluid level.
HYD G ENG 4 PUMP LO PR MEL 29-30-03-E
- Check GREEN hydraulic fluid level.
- Bleed GREEN hydraulic system.
HYD G RSVR LO AIR PR MEL 29-30-03-B
- Check Air pressure in reservoir from reservoir gauge.
- Pressurize the hydraulic reservoirs with APU Bleed air.
(Selection of ENG MASTER SW to crank will boost APU Bleed PX to
58 PSI for 30 sec).
HYD G RSVR LO LVL MEL 29-30-03-A
- Check GREEN hydraulic fluid level.
HYD B (G) (Y) RSVR OVHT MEL 29-30-03-C
- Check the PFR.
HYD G RSVR UNDERFILLED NO DISPATCH
- Check for obvious leaks.
- Re-fill the GREEN hydraulic system reservoir.
HYD G SYS LEAK Not Applicable
- Cross check fluid level indication on GREEN reservoir and ECAM
HYD page.
- Check for obvious leaks.
HYD CONTINUED
A.ICE
A.ICE CAPT AOA HEAT MEL 30-31-04
- Reset breaker PHC1 on the LH reset panel.
- Perform operational test of the Probe Ice protection system with the
MCDU (ATA 30)
A.ICE CAPT PITOT HEAT MEL 30-31-02
- Reset breaker PHC1 on the LH reset panel.
- Perform operational test of the Probe Ice protection system with the
MCDU (ATA 30)
A.ICE CAPT PROBES HEAT MEL 30-31-01
- Reset breaker PHC1 on the LH reset panel.
- Perform operational test of the Probe Ice protection system with the
MCDU (ATA 30)
A.ICE CAPT TAT HEAT MEL 30-31-05
- Reset breaker PHC1 on the LH reset panel.
- Perform operational test of the Probe Ice protection system with the
MCDU (ATA 30)
A.ICE DETECT FAULT MEL 30-81-01
- Cycle breaker ICE DET 1 on panel 721VU pos B08.
- Cycle breaker ICE DET 2 on panel 722VU pos F46.
- Perform operational test of the Probe Ice Detection system with the
MCDU (ATA 30)
A.ICE ENG 1 (2) (3) (4) VALVE CLOSED MEL 30-21-01
- ENG 1… Cycle breaker ANTI ICE ENG 1 on panel 722VU pos X39.
- ENG 1… Cycle breaker ANTI ICE ENG 2 on panel 721VU pos W06.
- ENG 1… Cycle breaker ANTI ICE ENG 3 on panel 722VU pos X40.
- ENG 1… Cycle breaker ANTI ICE ENG 4 on panel 721VU pos W07.
- Cycle breaker FADEC B ENG 1 on panel 722VU pos D44.
- Cycle breaker FADEC A ENG 1 on panel 742VU pos Q73.
- Check Engine Air Intake Anti-ice Valve (4000DN).
A.ICE ENG 1 VALVE OPEN MEL 30-21-01
- Cycle breaker ANTI ICE ENG 1 on panel 722VU pos X39.
- Cycle breaker FADEC B ENG 1 on panel 722VU pos D44.
- Cycle breaker FADEC A ENG 1 on panel 742VU pos Q73.
A.ICE ENG 2 VALVE OPEN MEL 30-21-01
- Cycle breaker ANTI ICE ENG 2 on panel 721VU pos W06.
- Cycle breaker FADEC B ENG 1 on panel 722VU pos D44.
- Cycle breaker FADEC A ENG 1 on panel 742VU pos Q73.
A.ICE ENG 3 VALVE OPEN MEL 30-21-01
- Cycle breaker ANTI ICE ENG 3 on panel 722VU pos X40.
- Cycle breaker FADEC B ENG 2 on panel 722VU pos K49.
- Cycle breaker FADEC A ENG 2 on panel 742VU pos Q73.
A.ICE ENG 4 VALVE OPEN MEL 30-21-01
- Cycle breaker ANTI ICE ENG 4 on panel 721VU pos W07.
- Cycle breaker FADEC B ENG 2 on panel 722VU pos K49.
- Cycle breaker FADEC A ENG 2 on panel 742VU pos Q73.
A.ICE CONTINUED
A.ICE CONTINUED
A.ICE CONTINUED
EIS
EIS DISPLAY DISCREPANCY NO DISPATCH
- Reset breaker DMC 1,2 and 3 on the LH and RH reset panels.
EIS ECAM DMC 1 FAULT MEL 31-62-01-B
- Reset breaker DMC 1 on the LH reset panel.
EIS ECAM DMC 2 FAULT MEL 31-62-01-B
- Reset breaker DMC 2 on the RH reset panel.
EIS ECAM DMC 3 FAULT MEL 31-62-01-B
- Reset breaker DMC 3 on the LH reset panel.
EIS EFIS DMC 1 FAULT MEL 31-62-01-A
- Reset breaker DMC 1 on the LH reset panel.
EIS EFIS DMC 2 FAULT MEL 31-62-01-A
- Reset breaker DMC 2 on the RH reset panel.
EIS EFIS DMC 3 FAULT MEL 31-62-01-A
- Reset breaker DMC 3 on the LH reset panel.
FWS
FWS EPC FAULT MEL 31-56-01
- Reset breaker FWC 1 and SDAC 1 on the LH reset panel.
- Reset breaker FWC 2 and SDAC 2 on the RH reset panel.
FWS FWC 1 FAULT MEL 31-53-01
- Reset breaker FWC 1 on the LH reset panel.
FWS FWC 1 + 2 FAULT MEL 31-53-01
- Reset breaker FWC 1 and FWC 2 on the LH and RH reset panels.
FWS FWC 2 FAULT MEL 31-53-01
- Reset breaker FWC 2 on the RH reset panel.
FWS SDAC 1 FAULT MEL 31-55-01
- Reset breaker SDAC 1 on the LH reset panel.
FWS SDAC 1 + 2 FAULT MEL 31-55-01
- Reset breaker SDAC 1 and SDAC 2 on the LH and RH reset panels.
FWS SDAC 2 FAULT MEL 31-55-01
- Reset breaker SDAC 2 on the RH reset panel.
RECORDER
RECORDER DFDR FAULT NO DISPATCH
- Cycle breaker FDIU/DFDR on panel 722VU pos F42.
RECORDER FDIU FAULT NO DISPATCH
- Cycle breaker FDIU/DFDR on panel 722VU pos F42.
WHEEL
WHEEL HYD SEL VALVE NO DISPATCH
- Cycle A/SKID & N/W STRG switch on F/O instrument panel.
WHEEL N/W STRG FAULT MEL 32-51-01
- Cycle A/SKID & N/W STRG switch on F/O instrument panel.
- Reset breakers LGCIU 1 and LGCIU 2 on the LH and RH reset
panels.
WHEEL TIRE LO PR NO DISPATCH
- Cycle A/SKID & N/W STRG switch on F/O instrument panel.
- Adjust tire pressures as required.
BRAKES
BRAKES A/SKID NWS OFF Not Applicable
- No action required is A/SKID & N/W STRG switch is in the OFF
position.
BRAKES ANTI SKID FAULT NO DISPTCH
- Cycle A/SKID & N/W STRG switch on F/O instrument panel.
BRAKES AUTO BRAKE FAULT MEL 32-42-02 or 32-42-04
- Cycle A/SKID & N/W STRG switch on F/O instrument panel.
BRAKES BSCU CH 1 FAULT MEL 32-42-03
- Perform BITE test of BSCU 1 on the MCDU (ATA 32)
BRAKES BSCU CH 2 FAULT
- Perform BITE test of BSCU 2 on the MCDU (ATA 32)
BRAKES HOT NO DISPATCH
- Max 150 deg C difference between 2 brakes on same gear.
- Max 200 deg C difference between brakes on LH and RH rears.
- Cool down brakes or delay dispatch until cool.
BRAKES RELEASED MEL 32-42-01 or 32-42-05
- Perform BITE test of BSCU 1 on the MCDU (ATA 32)
- Perform BITE test of BSCU 2 on the MCDU (ATA 32)
BRAKES RESIDUAL BRAKING MEL 32-42-01
- Perform BITE test of BSCU 1 on the MCDU (ATA 32)
- Perform BITE test of BSCU 2 on the MCDU (ATA 32)
L/G
L/G DOORS NOT CLOSED NO DISPATCH
- Perform visual inspection of Landing Gear Doors.
- Reset breaker LGCIU 1 and LGCIU 2 on the LH and RH rest panels.
L/G GEAR NOT DOWN Not Applicable
- No action if no PFR report.
L/G GEAR NOT DOWNLOCKED Not Applicable
- Reset breaker LGCIU 1 and LGCIU 2 on the LH and RH rest panels.
L/G GEAR NOT UPLOCKED Not Applicable
- Reset breaker LGCIU 1 and LGCIU 2 on the LH and RH rest panels.
L/G GEAR UPLOCK FAULT FCOM 2-04-25
- Check up lock Assy of all Landing Gears.
L/G L LENGTHENING FAULT FCOM 2-04-25
- Check for damage to the shortening mechanism or the proximity
sensor target on the LH Gear.
L/G R LENGTHENING FAULT FCOM 2-04-25
- Check for damage to the shortening mechanism or the proximity
sensor target on the RH Gear.
L/G LGCIU 1 FAULT MEL 32-31-01
- Reset breakers FWC 1 and LGCIU 1 on the LH reset Panel.
- Reset breakers FWC 2 and LGCIU 2 on the RH reset Panel.
L/G LGCIU 1 + 2 FAULT MEL 32-31-01
- Reset breakers FWC 1 and LGCIU 1 on the LH reset Panel.
- Reset breakers FWC 2 and LGCIU 2 on the RH reset Panel.
L/G LGCIU 2 FAULT MEL 32-31-01
- Reset breakers FWC 1 and LGCIU 1 on the LH reset Panel.
- Reset breakers FWC 2 and LGCIU 2 on the RH reset Panel.
L/G RETRACTION FAULT FCOM 2-04-25
- Check for damage to the proximity sensors or targets on all Gears.
L/G SYS DISAGREE NO DISPATCH
- Reset breaker LGCIU 1 and LGCIU 2 on the LH and RH rest panels.
NAV
NAV ADR 1 FAULT MEL 34-10-01-B
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Cycle breaker ADIRU1 115VAC on panel 721VU pos C04.
- Cycle breaker ADIRU1 28VDC on panel 742VU pos B80.
- Cycle breaker ADIRU1 BAT on panel 742VU pos K70.
NAV ADR 1 + 2 FAULT MEL 34-10-01-B
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Check PFR.
NAV ADR 1 + 3 FAULT MEL 34-10-01-B
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Check PFR.
NAV ADR 2 FAULT MEL 34-10-01-B
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Cycle breaker ADIRU2 115VAC on panel 722VU pos H46.
- Cycle breaker ADIRU2 BAT on panel 742VU pos G73.
NAV ADR 2 + 3 FAULT MEL 34-10-01-B
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Check PFR.
NAV ADR 3 FAULT MEL 34-10-01-B
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Cycle breaker ADIRU3 115VAC on panel 721VU pos G05.
- Cycle breaker ADIRU3 28VDC on panel 742VU pos F68.
- Cycle breaker ADIRU3 BAT on panel 742VU pos G74.
NAV ALTI DISCREPANCY MEL 34-10-01-B
- No action required if there is no failure on the PFR.
NAV ATT DISCREPANCY MEL 34-10-01-A
- No action required if there is no failure on the PFR.
NAV EXTREME LATITUDE Not Applicable
- No action required if there is no failure on the PFR.
NAV FM/IR POS DISAGREE Not Applicable
- Reset ADIRU 1 (2) (3)
- No action required if there is no failure on the PFR.
NAV GPWS FAULT MEL 34-38-01
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Re-rack ILS 1 after pulling breaker on panel 742VU pos P66.
NAV HDG DISCREPANCY MEL 34-10-01-A
- No action required if there is no failure on the PFR.
NAV ILS 1 FAULT MEL 34-36-01
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Re-rack ILS 1 after pulling breaker on panel 742VU pos P66.
NAV ILS 1 + 2 FAULT MEL 34-36-01
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Re-rack ILS 1 after pulling breaker on panel 742VU pos P66.
- Re-rack ILS 2 after pulling breaker on panel 722VU pos H44.
NAV ILS 2 FAULT MEL 34-36-01
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
- Re-rack ILS 2 after pulling breaker on panel 722VU pos H44.
NAV CONTINUED
APU
APU FAULT MEL 49-11-01
- Check the PFR
APU FIRE DET FAULT MEL 26-13
- Cycle breaker FDU LOOP B APU on panel 721VU pos P08.
- Cycle breaker FIRE LOOP A APU on panel 742VU pos D80.
APU FIRE LOOP A FAULT MEL 26-13-01
- If LOOP A OK…. Faulty FDU (13WG).
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
APU FIRE LOOP B FAULT MEL 26-13-01
- If LOOP B OK…. Faulty FDU (13WG).
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
DOOR
DOOR AFT CARGO MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR AVIONIC MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR BULK CARGO MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR FWD CARGO MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR L AFT CABIN MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR L EMER EXIT MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR L FWD CABIN MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR L MID CABIN MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR POS DET 1 FAULT MEL 52-71-01-A
- Reset breakers CPC 1 and CPC 2 on the LH and RH reset panels.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR POS DET 1 + 2 FAULT MEL 52-71-01-A
- Reset breakers CPC 1 and CPC 2 on the LH and RH reset panels.
- Cycle breaker DOORS & SLIDES CTL on panel 721VU pos N12.
- Cycle breaker DOORS & SLIDES CTL on panel 722VU pos P41.
DOOR POS DET 2 FAULT MEL 52-71-01-A
- Reset breakers CPC 1 and CPC 2 on the LH and RH reset panels.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR R AFT CABIN MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR R EMER EXIT MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR R FWD CABIN MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
DOOR R MID CABIN MEL 52-71-01-B
- Check proximity sensor and target.
- Perform system test of PSCU on the MCDU (ATA 52).
CONFIG
CONFIG FLAPS NO IN T.O. RANGE NO DISPATCH
- Check the PFR.
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
CONFIG L SIDESTICK FAULT Apply ECAM procedure.
- Check the PFR.
- If there is no failure message… no action is required.
CONFIG R SIDESTICK FAULT Apply ECAM procedure.
- Check the PFR.
- If there is no failure message… no action is required.
CONFIG PARK BRK ON NO DISPATCH
- Set brakes to OFF.
CONFIG PITCH TRIM NOT IN T.O. RANGE NO DISPATCH
- Check the PFR.
- If there is no failure message… no action is required.
CONFIG RUD TRIM NOT IN T.O. RANGE NO DISPATCH
- Check the PFR.
- If there is no failure message… no action is required.
CONFIG SLATS NOT IN T.O. RANGE NO DISPATCH
- Check the PFR.
- If there is no failure message… no action is required.
CONFIG SPD BRK NOT RETRACTED NO DISPATCH
- Check the PFR.
- If there is no failure message… no action is required.
ENG
ENG THRUST LOSS MEL 73-30-03-B
- Reset breaker ZONE CONT on the RH reset panel.
ENG ALL ENG FLAME OUT NO DISPATCH
- Check Fuel filters for contamination.
ENG THR LEVERS NOT SET MEL 73-20-01
- Operational message… no further actions required.
ENG T.O. THRUST DISAGREE NO DISPATCH
- Check the PFR for defective LRU’s.
ENG 1
ENG 1 BLEED STATUS Apply ECAM procedure
- Reset breaker ZONE CONT on the RH reset panel.
- Reset breaker EIVMU 1 on the RH reset panel.
ENG 1 CTL SYS FAULT NO DISPATCH
- Cycle breaker FADEC A ENG 1 on panel 742VU pos N74.
- Cycle breaker FADEC B ENG 1 on panel 722VU pos K46.
ENG 1 EGT OVERLIMIT Not Applicable
- Perform visual inspection of the effected engine.
ENG 1 EIU FAULT MEL 73-25-02
- Reset breaker EIVMU 1 on the RH reset panel.
- Reset breaker FCU 1 on the LH reset panel.
ENG 1 FADEC FAULT NO DISPATCH
- Reset breakers SDAC 1 and SDAC 2 on the LH and RH reset panels.
- Reset breaker FCU 1 on the LH reset panel.
ENG 1 FADEC OVHT NO DISPATCH
- Check for local overheating of the EEC, pay particular attention to the
Nacelle ANTI-ICE ducting for leakages.
ENG 1 FADEC SYS FAULT NO DISPATCH
- Reset breaker EIVMU 1 on the RH reset panel.
- Cycle breaker FADEC A ENG 1 on panel 742VU pos N74.
- Cycle breaker FADEC B ENG 1 on panel 722VU pos K46.
ENG 1 FIRE DET FAULT NO DISPATCH
- Perform BITE test of the FDU through the MCDU (ATA 26)
ENG 1 FIRE LOOP A FAULT MEL 26-12-01
- Perform BITE test of the FDU through the MCDU (ATA 26)
ENG 1 FIRE LOOP B FAULT MEL 26-12-01
- Perform BITE test of the FDU through the MCDU (ATA 26)
ENG 1 FUEL FILTER CLOG NO DISPATCH
- Check the fuel pump filter for contamination.
- Check the fuel pump differential pressure switch.
ENG 1 HP FUEL VALVE NO DISPATCH
- Perform FADEC system static test through the MCDU (ATA 70)
ENG 1 IGN A FAULT MEL 74-31-01 or 74-31-03-A
- Reset breaker EIVMU 1 on the RH reset panel.
ENG 1 IGN B FAULT MEL 74-31-01 or 74-31-03-A
- Reset breaker EIVMU 1 on the RH reset panel.
ENG 1 IGN A + B FAULT MEL 74-31-01 or 74-31-03-A
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
ENG 1 MINOR FAULT MEL 73-25-01-A
- Cycle breaker FADEC A ENG 1 on panel 742VU pos N74.
- Cycle breaker FADEC B ENG 1 on panel 722VU pos K46.
ENG 1 OIL FILTER CLOG MEL 79-35-02-A
- Check the oil filter for contamination.
- Check the oil filter differential pressure switch.
ENG 1 OIL HI TEMP NO DISPATCH
- Check engine oil level.
ENG 1 CONTINUED
ENG 2
ENG 2 BLEED STATUS Apply ECAM procedure
- Reset breaker ZONE CONT on the RH reset panel.
- Reset breaker EIVMU 2 on the LH reset panel.
ENG 2 CTL SYS FAULT NO DISPATCH
- Cycle breaker FADEC A ENG 2 on panel 742VU pos Q73.
- Cycle breaker FADEC B ENG 2 on panel 722VU pos D43.
ENG 2 EGT OVERLIMIT Not Applicable
- Perform visual inspection of the effected engine.
ENG 2 EIU FAULT MEL 73-25-02
- Reset breaker EIVMU 2 on the LH reset panel.
- Reset breaker FCU 1 on the LH reset panel.
ENG 2 FADEC FAULT NO DISPATCH
- Reset breakers SDAC 1 and SDAC 2 on the LH and RH reset panels.
- Reset breaker FCU 1 on the LH reset panel.
ENG 2 FADEC OVHT NO DISPATCH
- Check for local overheating of the EEC, pay particular attention to the
Nacelle ANTI-ICE ducting for leakages.
ENG 2 FADEC SYS FAULT NO DISPATCH
- Reset breaker EIVMU 2 on the LH reset panel.
- Cycle breaker FADEC A ENG 2 on panel 742VU pos Q73.
- Cycle breaker FADEC B ENG 2 on panel 722VU pos D43.
ENG 2 FIRE DET FAULT NO DISPATCH
- Perform BITE test of the FDU through the MCDU (ATA 26)
ENG 2 FIRE LOOP A FAULT MEL 26-12-01
- Perform BITE test of the FDU through the MCDU (ATA 26)
ENG 2 FIRE LOOP B FAULT MEL 26-12-01
- Perform BITE test of the FDU through the MCDU (ATA 26)
ENG 2 FUEL FILTER CLOG NO DISPATCH
- Check the fuel pump filter for contamination.
- Check the fuel pump differential pressure switch.
ENG 2 HP FUEL VALVE NO DISPATCH
- Perform FADEC system static test through the MCDU (ATA 70)
ENG 2 IGN A FAULT MEL 74-31-01 or 74-31-03-A
- Reset breaker EIVMU 2 on the LH reset panel.
ENG 2 IGN B FAULT MEL 74-31-01 or 74-31-03-A
- Reset breaker EIVMU 2 on the LH reset panel.
ENG 2 IGN A + B FAULT MEL 74-31-01 or 74-31-03-A
- Reset breakers FWC 1 and FWC 2 on the LH and RH reset panels.
ENG 2 MINOR FAULT MEL 73-25-01-A
- Cycle breaker FADEC A ENG 2 on panel 742VU pos Q73.
- Cycle breaker FADEC B ENG 2 on panel 722VU pos D43.
ENG 2 OIL FILTER CLOG MEL 79-35-02-A
- Check the oil filter for contamination.
- Check the oil filter differential pressure switch.
ENG 2 OIL HI TEMP NO DISPATCH
- Check engine oil level.
ENG 2 CONTINUED