6 TOTAL IR SUBMITTED

3 UR UNDER REVIEW

INSPECTIONS LOG 1 A APPROVED

Project No: PACKAGE G3-BEACH BAR-THE ROYAL ATLANTIS RESORT AND RESIDENCES 5 B APPROVED AS NOTED

Contractor: SSANGYONG ENGINEERING 1 C REVISE AND RESUBMIT

Date: 20-Jun-24 2 D REJECTED

Document SBJV Response email DEC Response email


S/N
Reference Aconex Reference No. Descipline Type of Submission Title/Details Rev Date Submitted Status Latest Status Latest Status Notices
Aconex Ref Date Aconex Ref Date

SBJV-Submit with Copy of OIR form, Approved


HLLC-OIR-000001 CO OFFSITE WIR 0 26-Apr-21 D SBJV-ROIR-000508 26-Apr-21 SBJV-ROIR-000508 26-Apr-21 MAR and copy of mix design.Description of OIR
should be with mix code and location of trial mix.

CONCRETE TRIAL MIX C50 SUBSTRUCTURE & DEC-CONCRETE TRIAL MIX FOR C50 (Mix code
1 TRA-HYL-OIR-CO-GEN-02547 00
SUPERSTRUCTURE CONCRETE 502M7X4-4-S47D) SUB STRUCTURE & SUPER
STRUCTURE By approved Third party Wimpey
Approved as Approved as Laboratory at Cemex top mix Readymix plant Jabel
HLLC-OIR-000003 CO OFFSITE WIR 0 28-Apr-21 B DECAE-ROIR-001793 4-May-21
Noted
DECAE-ROIR-001793 4-May-21
Noted Ali. (PLANT No. 306 / Batch No.1)has been carried
out /witnessed on 2nd May 2021 at Jabel Ali plant
with attached Initial report.
Contractor is required to fallow the cubes crushing
witnessing and all other test to be done at
approved lab .

2 TRA-HYL-OIR-CO-GEN-02548 00 HLLC-OIR-000004 CO OFFSITE WIR CONCRETE TRIAL MIX C25 - BLINDING 0 28-Apr-21 UR

CONCRETE TRIAL MIX FOR READY MIX


SCREED C20 (MIX CODE: 201X6X1-4-U21D)
Approved as Approved as FOR WP AREA PROTECTION & TO RECEIVE
3 TRA-HYL-OIR-CO-GEN-02549 00 HLLC-OIR-000005 CO OFFSITE WIR CONCRETE TRIAL MIX C20 - READY MIX 0 28-Apr-21 B DECAE-ROIR-001807 10-May-21
Noted
DECAE-ROIR-001807 10-May-21
Noted FINISHES by approved Third-party Wimpey
Laboratory at Cemex top mix Readymix plant Jabel
Ali. (Plant 306)has been carried out at jabal Ali
palnt

4 TRA-HYL-OIR-CO-GEN-02550 00 HLLC-OIR-000006 CO OFFSITE WIR CONCRETE TRIAL MIX C20 - DRY MIX 0 28-Apr-21 UR

CONCRETE TRIAL MIX FOR C50 (Mix code


502M7X4-4-S47D) SUB STRUCTURE & SUPER
STRUCTURE By approved Third party Wimpey
Laboratory at Cemex top mix Readymix plant Jabel
CONCRETE TRIAL MIX FOR C50 (Mix code 502M7X4-4- Approved as Approved as
5 TRA-HYL-OIR-CO-GEN-02551 00 HLLC-OIR-000007 CO OFFSITE WIR
S47D) SUB STRUCTURE & SUPER STRUCTURE
0 5-May-21 B DECAE-ROIR-001803 6-May-21
Noted
DECAE-ROIR-001803 6-May-21
Noted
Ali. (PLANT No. 306 / Batch No.2) has been
witnessed ,and initail report attached ,
Submit all related test result report by 3rd party for
final approval.

CONCRETE TRIAL MIX FOR C50 (Mix code


502M7X4-4-S47D) SUB STRUCTURE & SUPER
STRUCTURE By approved Third party Wimpey
Laboratory at Cemex top mix Readymix plant Jabel
CONCRETE TRIAL MIX FOR C50 (Mix code 502M7X4-4- Ali. (PLANT No. 306 / Batch No.3)has been carried
S47D) SUB STRUCTURE & SUPER STRUCTURE By Approved as Approved as out at jabal Ali palnt
6 TRA-HYL-OIR-CO-GEN-02552-R00 HLLC-OIR-000013 CO OFFSITE WIR
approved Third party Wimpey Laboratory at Cemex top mix
0 9-May-21 B DECAE-ROIR-001806 10-May-21
Noted
DECAE-ROIR-001806 10-May-21
Noted Required supporting documents attached .
Readymix plant Jabel Ali. (PLANT No. 306 / Batch No.3 Submit all required test report by 3rd paty lab for
review& final approval.