IFC 011 K, F Signal Converter

For electromagnetic flowmeters

• Easy and user friendly installation and operator control

• Best in class measuring accuracy, ± 0.5% of measured value

• Integrated totaliser

• Simple and user friendly menu


IFC 011 K, F Signal Converter
For electromagnetic flowmeters
Features
• Simple and easy programming

• Flow measurement in both directions

• Galvanically isolated Current output linear to flow

• Indication through 7 segment 8 digit LED display

• User defined flow units

• In built flow totaliser

Signal converter for electromagnetic flowmeters


• User friendly and easy to operate

• Available versions

IFC 011K – Compact system (Integral with flow sensor)

IFC 011F – Separate system (Field housing)

• Suitable for primary head size 3/8” to 24” / DN10 to DN600

Display:
Instantaneous and
totalized flow

Isolated outputs

Mounting bracket
Technical Specifications

Flow rate for Q=100% Adjustable 0.085 to 12216m³/hr corresponding to velocity


of 0.3 to 12m/s
Flow units User defined flow units - m³/hr, liters/hr,
US gallons/hr, hectoliters/hr etc
Error limits ± 0.5% of measured valve + 1mm/s
Display 8 digit seven segment LED display
Functions Actual flow rate in user defined units
Totaliser m³, liters, US gallons LanguageEnglish
Current output
Function All operating date settable, galvanically isolated
Current 0 – 20mA or 4 – 20mA
Load- Active mode 500 Ohms maximum
Error identification 0 / 3.6 / 22mA
Low flow cut off ON – Value 0.1 – 19% of Q100% adjustable in
OFF – Value 0.2 – 20% 1% increments
Power supply
1. Rated voltage 230 / 240 VAC
Tolerance band 200 – 260 VAC
2. Rated voltage 115 / 120 VAC
Tolerance band 100 – 130 VAC
Frequency 48 – 63 Hz
Coil drive ± 125mA
Excitation frequency F, F/2 and F/4
Housing Die cast aluminium
Ambient temperature -25 to 60 Deg C
Protection category IP 65 equivalent to NEMA 4
Signal converter IFC 011 is compatible with below mentioned KROHNE primary heads.
Compact / Separate systems Primary head details
Aquamag Meter size : 2” to 6” / DN50 to DN150
Liner : Hardrubber
Ecomag Meter size : 1” to 6” / DN25 to DN150
Liner : PTFE
Aquaflux Meter size : 2” to 24” / DN50 to DN600
Liner : Hardrubber, Neoprene and Polyurethene
IFS 4000 Meter size : 3/8” to 24” / DN10 to DN600
Liner : PTFE, PFA and ETFE
Dimensions and weights

IFC 011 Signal converter IFC 011 connection diagram with DS cable
Dimensions in mm, weight approx 1.5 kg

120

120

KROHNE
MARSHALL 213

69

69

101

Signal cable type DS

1 Stranded drain wire, 1st shield,


1.5 mm² or AWG 14

2 Insulation
3 Stranded wire 0.5 mm² or AWG 20
4 Special foil, 1st shield
5 Insulation
6 Mu-metal foil 2nd shield
7 Stranded drain wire, 2nd shield, 0.5 mm² or AWG 20
8 Outer sheath

Doc#CIG/0912 /302/V1.R0

KROHNE Marshall Pvt. Ltd. Tel.: +91 (0)20 27442020


A-34/35, MIDC, Fax: +91 (0)20 27442040
Industrial Estate, E-mail: ksales@krohnemarshall.com
'H' Block, Pimpri, www.krohne.com
Pune - 411 018. India. www.forbesmarshall.com