GEOTECHNICAL

ENGINEERING REPORT
(PIPE PILE)
General Information
ELS Size: 170m x 120m
Depth: 15.0mPD-3.0mPD
Water Table: +12.0mPD
Surcharge nearby: 25kPa
Design magnitude of the earthquake (M) is assumed as 6.8 with its
centre located 50 km away
Design Peak effective ground acceleration is estimated as 0.1g -
0.2g
Plaxis 3d pipe piles analysis
Data input: Borehole data
Data input: Soil and interfaces data
Generated mesh :
Water level
PHASE 01 Static situation
Total displacements u_y :
Total displacements u_x :
Total displacements uZ :
PHASE 02 Dynamic situation
Parameters for seismic situation
Total displacements u_y
Total displacements u_x
PHASE 03 Dynamic Situation
5 seconds dynamic time interval simulation
Total displacements u_y (5 Seconds)
Total displacements u_x (5 seconds) :
Total displacements U_z (5 seconds)
«settlement »
Conclusion
• To ensure the reliability of our solution, we incorporated it into the calculations,
which yielded satisfactory results for the three study areas:

• - Maximum displacement UX calculated (dynamic case) = 4.30 cm, Acceptable.

• - Maximum displacement UY calculated (dynamic case) = 2.20 cm, Acceptable.

• - Maximum displacement UZ (Settlement) calculated (dynamic case) = 3.30 cm,


Acceptable.