Improvements to the Project House of Sholayar Dam at Sholayar Nagar- Brick work

and Plastering First Floor


1 Brick work in following Cement Mortar 1:6 using best quality II class ground
moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" for foundation and
basement including curing, etc., complete complying with standard
specifiction.
Measurement
For Superstructure in First Floor
Left side hall
Side1 1 x 1 9.90 0.23 1.80 4.10
Side2 1 x 1 7.46 0.23 2.15 3.69
Side3 1 x 1 14.75 0.23 1.80 6.11
Side4 1 x 1 7.46 0.23 2.00 3.43
Deduction 39.57
Side 1 -1 x 3 1.50 1.20 -5.40
Side 3 -1 x 3 1.50 1.20 -5.40
Side 4 -1 x 1 1.20 2.05 -2.46
Dinning Hall
Side1 1 x 1 8.00 0.23 2.80 5.15
Side2 1 x 1 5.36 0.23 2.00 2.47
Side3 1 x 1 8.00 0.23 2.00 3.68
Side4 1 x 1 4.69 0.23 2.00 2.16
Deduction 26.05
Side 1 -1 x 1 1.50 1.20 -1.80
Side 3 -1 x 1 1.50 1.20 -1.80
Side 4 -1 x 1 1.20 2.05 -2.46
Right side hall
Side1 1 x 1 17.65 0.23 2.00 8.12
Side2 1 x 1 7.46 0.23 2.20 3.77
Side3 1 x 1 17.65 0.23 2.00 8.12
Side4 1 x 1 5.00 0.23 1.67 1.92
Deduction 47.76
Side 1 -1 x 4 1.50 1.20 -7.20
Side 3 -1 x 4 1.50 1.20 -7.20
19.00 m3
2
Plastering with cement mortar 1:5 (One part of cement and five parts of sand )
12 mm thick including finishing and curing complying with technical
specification as directed by the Engineer in charge of the work.
Measurement
First Floor inner side
For Left side hall (side1) 1 x 1 9.90 1.80 17.82
Side 2 1 x 1 7.00 1.98 13.83
Side 3 1 x 1 14.75 1.80 26.55
Side 4 (Front and back) 1 x 2 7.00 1.98 27.65
Window jambs 2 x 3 5.40 0.23 7.45
Door jambs 1 x 1 5.40 0.23 1.24
Left Side wall Deduction
Side 1 -1 x 3 1.50 1.20 -5.40
Side 3 -1 x 3 1.50 1.20 -5.40
Side 4 -1 x 1 1.20 2.05 -2.46

For Right side hall 1x1 42.30 2.20 93.06


Side 4 (Front and back) 1x2 5.00 1.67 16.70

Window jambs 2x4 5.40 0.23 9.94


Door jambs 1x1 5.40 0.23 1.24
Deduction
Side 1 -1 x 4 1.50 1.20 -7.20
Side 3 -1 x 4 1.50 1.20 -7.20
For Dinning hall 1 x 2 8.00 1.85 29.60
1 x 1 4.90 2.80 13.72
Side 4 (Front and back) 1 x 2 4.90 2.80 27.44
Window jambs 1 x 2 5.40 0.23 2.48
Door jambs 1 x 1 5.40 0.23 1.24
Deduction
Side 1 -1 x 1 1.50 1.20 -1.80
Side 3 -1 x 1 1.50 1.20 -1.80
Side 4 -1 x 1 1.20 2.10 -2.52
First Floor outer side
For Left side hall 1x1 32.57 2.00 65.14
Left Side wall Deduction
Side 1 -1 x 3 1.50 1.20 -5.40
Side 3 -1 x 3 1.50 1.20 -5.40

For Right side hall 1x1 43.22 2.20 95.08


Deduction
Side 1 -1 x 4 1.50 1.20 -7.20
Side 3 -1 x 4 1.50 1.20 -7.20
For Dinning hall 1x1 26.72 2.80 74.82

Deduction
Side 1 -1 x 1 1.50 1.20 -1.80
Side 3 -1 x 1 1.50 1.20 -1.80
462.42 m2
Agt Rate Amount

9420.00 178980.00

Agt Rate Amount


320.00 147974.40
Improvements to the Project House of Sholayar Dam at Sholayar Nagar
1 Brick work in following Cement Mortar 1:6 using
best quality II class ground moulded chamber
burnt bricks of size 9" x 4-3/8" x 2-3/4" for
foundation and basement including curing, etc.,
complete complying with standard specifiction.

b 19.00 m3 For Superstructure in First Floor 9420.00 m3 178980


2 462.42 m2
Plastering with cement mortar 1:5 (One part of 277.85 m2
128483
cement and five parts of sand ) 12 mm thick
including finishing and curing complying with
technical specification as directed by the Engineer
in charge of the work.

Total 307463
Improvements to the Project House of Sholayar Dam at Sholayar Nagar- Tiles and
Granite measurement
Sl.
Description Nos L B D Quantity
No
1
Paving the floor with Double charged vitrified tiles of size 600 x 600 x 8mm
laid over 20 mm thick cement mortar 1:3 (one cement and three sand) base
mortar over the existing slab/ floor including cutting the tiles to th required size
with special cuttrt eherever necessary, laying in position and pointing with
white cement mixed with colouring pigment at the rate of .3 kg/sq,m.etc.,
complete complying with standard specification. ( The make and brand of tiles
should be got approved from Executive Engineer before use in works).

Measurement
First Floor
Dining hall 1 x 1 12.58 4.20 52.84
Power room jamb 1 x 1 1.05 0.35 0.37
Opposite jamb 1 x 1 1.05 0.35 0.37
front door jamb 1 x 1 1.05 0.55 0.58
kitchen front 1 x 1 3.25 2.35 7.64
kitchen front jamb 1 x 1 1.05 0.55 0.58
kitchen door jamb 1 x 1 1.05 0.55 0.58
kitchen 1 x 1 4.15 3.25 13.49
kitchen jamb 1 x 1 1.05 0.50 0.53
kitchen store 1 x 1 2.40 1.45 3.48
Left hall 1 x 1 10.80 7.00 75.60
Dining hall 1 x 1 4.40 7.90 34.76
Right hall 1 x 1 7.00 17.90 125.30
Door jams 1 x 3 1.20 0.30 0.36
316.48

2 Paving the floor with best approved quality fine polished Granite Stone Slabs of
size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar
varieties with machine cut edges laid over a cement mortar bed of 20mm thick
using cement mortar 1:3 (One cement and three sand) fixing the slabs with
required cement slurry and laid in true right angles with minimum possible
width of joints and pointing the joints with white cement mixed with mathcing
colouring pigments etc., The granite stone slabs and other materials to be used
shall be got approved by the Executive Engineer concerned before use on work,
etc., complete as per standard speicification.

Measurement
Sitout 1 1x1 2.85 2.05 5.84
Sitout door Jamb 1x1 1.05 0.55 0.58
Front side room 1 1x1 2.07 3.00 6.21
Front side door 1x1 1.05 0.55 0.58
Front side of room 2 1 x 1 2.08 9.20 19.14
Front side of dining hall 1 x 1 2.60 4.85 12.61
Front opening jamb 1 x 2 0.23 2.45 1.13
Side 1 x 1 0.45 1.40 0.63
Staircase bottom 1 x 1 6.50 3.60 23.40
Living area 1 x 1 1.40 3.70 5.18
For Room No3 side 1 x 1 4.03 2.15 8.65
Room 3 & 4 front 1 x 1 13.00 2.10 27.30
Door jamb 1 x 1 1.05 0.55 0.58
Room 5 front 1 x 1 3.00 2.05 6.15
Door jamb 1 x 1 1.05 0.55 0.58
Siteout 5 1 x 1 2.85 2.05 5.84
Skirting for verandah 1x 1 101.54 0.1 10.154
Suit 1 1 x 1 4.85 4.42 21.44
Suit 2 1 x 1 3.60 4.42 15.91
Suit 3 1 x 1 3.63 4.20 15.25
Suit 4 1 x 1 3.63 4.20 15.25
Suit 5 1 x 1 4.85 4.20 20.37
Skirting for Room 1x 1 18.54 0.1 1.854
Skirting for Room 1x 3 15.6 0.1 4.68
Skirting for Room 1x 1 18.1 0.1 1.81
Steps Thread 1 x 17 0.95 0.3 4.845
Steps Raiser 1 x 17 0.95 0.15 2.4225
Mid Landing 1x 2 1 1 2
Skirting for Steps 1 x 17 0.45 0.1 0.765
Skirting for Mid Landing 1x 2 2 0.1 0.4
Main Entrance Steps Thread 1x 3 2.45 0.45 3.3075
Main Entrance Steps Raiser 1x 3 2.45 0.2 1.47
246.33

Suit 1 1 x 1 4.85 4.42 21.44


Suit 2 1 x 1 3.60 4.42 15.91
Suit 3 1 x 1 3.63 4.20 15.25
Suit 4 1 x 1 3.63 4.20 15.25
Suit 5 1 x 1 4.85 4.20 20.37
Skirting for Room 1x 1 18.54 0.1 1.854
Skirting for Room 1x 3 15.6 0.1 4.68
Skirting for Room 1x 1 18.1 0.1 1.81
96.56
Tiles and

Unit

Agt Rate Amount

m2 1640 519027.2

Agt Rate Amount


124.40

111.77

m2 1640 403977.9

268.03
Improvements to the Project House of Sholayar Dam at Sholayar Nagar
1 246.33 m2 Dismantling Mosaic-in-situ finish in cement 70.00 m2 17243
mortar in flooring and in wall surfaceas per
standard specifications and as directed by the
departmental officers.
2 316.48 m2 Paving the floor with Double charged vitrified 1640.00 m2 519027
tiles of size 600 x 600 x 8mm laid over 20 mm
thick cement mortar 1:3 (one cement and three
sand) base mortar over the existing slab/ floor
including cutting the tiles to th required size with
special cuttrt eherever necessary, laying in
position and pointing with white cement mixed
with colouring pigment at the rate of .3
kg/sq,m.etc., complete complying with standard
specification. ( The make and brand of tiles
should be got approved from Executive Engineer
before use in works).

3 246.33 m2 Paving the floor with best approved quality fine 2730.00 m2 672475
polished Granite Stone Slabs of size 1200 x 600
of 18 / 20mm thick of Synthetic Grey, Paradise
and similar varieties with machine cut edges laid
over a cement mortar bed of 20mm thick using
cement mortar 1:3 (One cement and three sand)
fixing the slabs with required cement slurry and
laid in true right angles with minimum possible
width of joints and pointing the joints with white
cement mixed with mathcing colouring pigments
etc., The granite stone slabs and other materials to
be used shall be got approved by the Executive
Engineer concerned before use on work, etc.,
complete as per standard speicification.

Total 1208745
Improvements to the Project House of Sholayar Dam at Sholayar Nagar
Sl.
Description Nos L B D
No
1 Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Doors of casement
type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile
are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are
multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour)
covered with over all the edges of frame and shutter the shutter will be provided with
Espag multi power point locks and also it operates as handle. The corners and joints
should be welded and cleaned. Radiations free pin headed plain or brown colour glass
4mm thick should be provided to the shutter and it should not allow leakage of water
even at most ranging storms and should have key lockable action, security protective
hinges, strong locking systems and as per size for arresting noise and energy loss. The
connecting mechanism between sash and outer frame that enables opening of the
window. The window should be fixed to the wall with 100% packing with screws and
silicon packing all round the frames. The Doors should be got approved from the
Executive Engineer before use on work.

Measurement
Ground Floor
Room No.1 Main door 1 x 1 1.05 - 2.10
Restroom Door 1 x 1 0.90 - 2.10
Sit out 1 Entrance 1 x 1 1.05 - 2.10
Verandah Entrance 1 x 1 1.05 - 2.10
Room No.2 Main door 1 x 1 1.07 - 2.10
Restroom Door 1 x 1 0.90 - 2.50
Room No.3 Main door 1 x 1 1.05 - 2.10
Dressing Entrance 1 x 1 0.90 - 2.10
Restroom Door 1 x 1 0.90 - 2.10
Room No.4 Main Door 1 x 1 1.05 - 2.10
Restroom Door 1 x 1 0.90 - 2.10
Room No.5 Main Door 1 x 1 1.05 - 2.10
Restroom Door 1 x 1 0.90 - 2.10
Sit out Entrance 1 x 1 1.05 - 2.10
Verandah Entrance 1 x 1 1.05 - 2.10
First Floor Entrance Door 1 x 1 1.00 - 2.10
Room No.6 Main Door 1 x 1 1.05 - 2.10
Restroom Door 1 x 1 1.05 - 2.10
Room No.7 Main Door 1 x 1 1.15 - 2.80
Restroom Door 1 x 1 0.90 - 2.10
Dinning Hall Entrance 1 x 1 1.15 - 2.10
Dinning Hall Left 1 x 1 1.15 - 2.10
Dinning Hall Right 1 x 1 1.15 - 2.10
Kitchen (Left) Entrance Door 1 x 1 1.15 - 2.10
Kitchen (Left) Entrance Door 1 1 x 1 1.15 - 2.10
Kitchen (Left) Back Door 1 x 1 1.15 - 2.10
Kitchen (Right) Entrance Door 1 x 1 1.15 - 2.10
Kitchen (Right) Back Door 1 x 1 1.15 - 2.10
Store room 1 x 1 0.85 - 2.00
Driver room door 1 x 1 0.95 - 1.95
Outside toilet door 1 x 1 0.85 - 1.80
Power room door 1 x 1 0.85 - 1.80
First Floor
Left side Meeting Hall 1x1 1.20 - 2.10
Right side Meeting Hall 1x1 1.20 - 2.10
Dinning hall 1x1 1.20 - 2.10
32
2 Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement
type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile
are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are
multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour)
covered with over all the edges of frame and shutter the shutter will be provided with
Espag multi power point locks and also it operates as handle. The corners and joints
should be welded and cleaned. Radiations free pin headed plain or brown colour glass
4mm thick should be provided to the shutter and it should not allow leakage of water
even at most ranging storms and should have key lockable action, security protective
hinges, strong locking systems and as per size for arresting noise and energy loss. The
connecting mechanism between sash and outer frame that enables opening of the
window. The window should be fixed to the wall with 100% packing with screws and
silicon packing all round the frames. The window should be got approved from the
Executive Engineer before use on work

Measurement
Sit Out.1 (centre window) 1x1 1.02 - 1.17
Sit Out.1 (Right side window) 1x1 2.07 - 1.17
Sit Out.1 (Left side window) 1x1 2.84 - 1.17
Room No.1 (Centre window) 1x1 1.50 - 1.20
Room No.1 (Left window) 1x1 1.50 - 1.20
Verandha before Room.1 1x1 2.40 - 1.17
Verandha before Room.2 1x1 2.40 - 1.20
Verandha before Room.2 1x1 4.06 - 1.20
Room No.2 (Centre window) 1x1 1.50 - 1.20
Room No.2 (Left side window) 1x1 1.17 - 1.34
Room No.3 (Centre window) 1x1 1.50 - 1.20
Room No.3 (Side window) 1x1 1.20 - 1.35
Room No.3 (Left side window) 1x1 0.90 - 1.35
Room No.4 (Centre window) 1x1 1.50 - 1.20
Room No.4 (Side window) 1x1 1.20 - 1.37
Verandha before Room No.3,4 1x1 1.20 - 3.00
Verandha before Room No.3,5 1 x 1 1.20 - 3.00
Verandha before Room No.3,6 1 x 1 1.20 - 3.63
Room No.5 (Centre window) 1 x 1 1.50 - 1.20
Room No.5 (Side window) 1 x 1 1.50 - 2.20
Verandha before Room.5 1 x 1 2.40 - 1.20
Sit Out.5 (centre window) 1 x 1 2.85 - 1.20
Sit Out.5 (Right side window) 1 x 1 2.10 - 1.20
Sit Out.5 (Left side window) 1 x 1 1.20 - 1.20
Room No.6 (Side Window) 1 x 1 0.75 - 1.50
Room No.6 (Centre Window) 1 x 1 4.40 - 1.30
Verandha before Room.6 1 x 1 1.20 - 3.00
Verandha before Room.6 side 1 x 1 1.00 - 1.80
Room No.7 Window 1 1 x 1 3.00 - 1.25
Room No.7 Window 2 1 x 1 4.50 - 1.25
Room No.7 Window 3 1 x 1 1.50 - 2.25
Room No.7 Window 4 1 x 1 1.50 - 1.25
Room No.7 Window 5 1 x 1 0.85 - 0.85
Kitchen 1 x 6 1.20 - 0.90
Dinning Hall Inner windows 1 x 4 1.50 - 1.20
Dinning Hall Entrance 1 x 1 2.00 - 1.05
Dinning Hall Entrance 1 x 1 1.10 - 1.05
Power room Windows Both sides 1 x 2 0.90 - 1.20
Driver room 1 x 1 0.90 - 1.20
G F Front Large Window 1 x 1 2.84 - 1.99
G F Front Large Window 1 x 1 3.00 - 1.65
First Floor
Left side Meeting Hall 1x6 1.50 - 1.20
Right side Meeting Hall 1x8 1.50 - 1.20
Dinning hall 1x2 1.50 - 1.20
66
3 Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators
of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60
x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free,
the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber
(black colour) covered with all over the edges of frame and shutter. The corners and
joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be
provided in the louvers. The window should be fixed to the wall with 100% packing
with screws and silicon packing all round the frames. The ventilator should be got
approved from the Executive Engineer before use on work

Measurement
Room No.1 Restroom 1x3 0.90 - 0.40
Room No.2 Restroom 1x2 0.90 - 0.40
Room No.3 Restroom 1x2 0.90 - 0.40
Room No.4 Restroom 1x2 0.90 - 0.40
Room No.5 Restroom 1 x 2 0.90 - 0.45
1 x 2 1.50 - 0.50
Room No.6 Restroom 1 x 2 0.90 - 0.45
Room No.7 1 x 2 0.90 - 0.40
17
layar Nagar

Quantity Unit

Agt Rate Amount

2.21
1.89
2.21
2.21
2.25
2.25
2.21
1.89
1.89
2.21
1.89
2.21
1.89
2.21
2.21
2.10
2.21
2.21
3.22
1.89
2.42
2.42
2.42
2.42
2.42
2.42
2.42
2.42
1.70
1.85
1.53
1.53

2.52
2.52
2.52
76.80 m2 8120.00 623616

Agt Rate Amount


1.19
2.42
3.32
1.80
1.80
2.81
2.88
4.87
1.80
1.57
1.80
1.62
1.22
1.80
1.64
3.60
3.60
4.36
1.80
3.30
2.88
3.42
2.52
1.44
1.13
5.72
3.60
1.80
3.75
5.63
3.38
1.88
0.72
6.48
7.20
2.10
1.16
2.16
1.08
5.65
4.95

10.80
14.40
3.60
146.70 m2 7310.00 1072377

1.08
0.72
0.72
0.72
0.81
1.50
0.81
0.72
7.10 m2 6893.00 48940.3
Improvements to the Project House of Sholayar Dam at Sholayar Nagar- Tiles and
Granite measurement
Sl.
Description Nos L B D Quantity
No
1
Paving the floor with Double charged vitrified tiles of size 600 x 600 x 8mm
laid over 20 mm thick cement mortar 1:3 (one cement and three sand) base
mortar over the existing slab/ floor including cutting the tiles to th required size
with special cuttrt eherever necessary, laying in position and pointing with
white cement mixed with colouring pigment at the rate of .3 kg/sq,m.etc.,
complete complying with standard specification. ( The make and brand of tiles
should be got approved from Executive Engineer before use in works).

Measurement
First Floor
Suit 1 1 x 1 4.85 4.42 21.44
Suit 2 1 x 1 3.60 4.42 15.91
Suit 3 1 x 1 3.63 4.20 15.25
Suit 4 1 x 1 3.63 4.20 15.25
Suit 5 1 x 1 4.85 4.20 20.37
Skirting for Room 1x 1 18.54 0.1 1.854
Skirting for Room 1x 3 15.6 0.1 4.68
Skirting for Room 1x 1 18.1 0.1 1.81
Left hall Skirting 1 x 1 35.60 0.10 3.56
Left hall 1 x 1 10.80 7.00 75.60
Right hall 1 x 1 7.00 17.90 125.30
Right hall skirting 1 x 1 49.80 0.10 4.98
Door jams 1 x 3 1.20 0.30 0.36
306.36

2 Paving the floor with best approved quality fine polished Granite Stone Slabs of
size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar
varieties with machine cut edges laid over a cement mortar bed of 20mm thick
using cement mortar 1:3 (One cement and three sand) fixing the slabs with
required cement slurry and laid in true right angles with minimum possible
width of joints and pointing the joints with white cement mixed with mathcing
colouring pigments etc., The granite stone slabs and other materials to be used
shall be got approved by the Executive Engineer concerned before use on work,
etc., complete as per standard speicification.

Measurement
Dining hall 1x 1 12.58 4.20 52.84
Power room jamb 1x 1 1.05 0.35 0.37
Opposite jamb 1x 1 1.05 0.35 0.37
front door jamb 1x 1 1.05 0.55 0.58
kitchen front 1x 1 3.25 2.35 7.64
kitchen front jamb 1 x 1 1.05 0.55 0.58
kitchen door jamb 1 x 1 1.05 0.55 0.58
kitchen 1 x 1 4.15 3.25 13.49
kitchen jamb 1 x 1 1.05 0.50 0.53
kitchen store 1 x 1 2.40 1.45 3.48
Sitout 1 1 x 1 2.85 2.05 5.84
Sitout door Jamb 1 x 1 1.05 0.55 0.58
Front side room 1 1 x 1 2.07 3.00 6.21
Front side door 1 x 1 1.05 0.55 0.58
Front side of room 2 1 x 1 2.08 9.20 19.14
Front side of dining hall 1 x 1 2.60 4.85 12.61
Front opening jamb 1 x 2 0.23 2.45 1.13
Side 1 x 1 0.45 1.40 0.63
Staircase bottom 1 x 1 6.50 3.60 23.40
Living area 1 x 1 1.40 3.70 5.18
For Room No3 side 1 x 1 4.03 2.15 8.65
Room 3 & 4 front 1 x 1 13.00 2.10 27.30
Door jamb 1 x 1 1.05 0.55 0.58
Room 5 front 1 x 1 3.00 2.05 6.15
Door jamb 1 x 1 1.05 0.55 0.58
Siteout 5 1 x 1 2.85 2.05 5.84
Skirting for verandah 1x 1 101.54 0.1 10.154
Steps Thread 1x 17 0.95 0.3 4.845
Steps Raiser 1x 17 0.95 0.15 2.4225
Mid Landing 1x 2 1 1 2
Skirting for Steps 1x 17 0.45 0.1 0.765
Skirting for Mid Landing 1x 2 2 0.1 0.4
Main Entrance Steps Thread 1x 3 2.45 0.45 3.3075
Main Entrance Steps Raiser 1x 3 2.45 0.2 1.47
Dining hall 1x 1 4.40 7.90 34.76
Dining hall skirting 1x 1 24.60 0.10 2.46
267.44

Suit 1 1 x 1 4.85 4.42 21.44


Suit 2 1 x 1 3.60 4.42 15.91
Suit 3 1 x 1 3.63 4.20 15.25
Suit 4 1 x 1 3.63 4.20 15.25
Suit 5 1 x 1 4.85 4.20 20.37
Skirting for Room 1x 1 18.54 0.1 1.854
Skirting for Room 1x 3 15.6 0.1 4.68
Skirting for Room 1x 1 18.1 0.1 1.81
96.56
Tiles and

Unit

Agt Rate Amount

124.40

m2 1640 502437

Agt Rate Amount


842.95

m2 1640 438608.2

1057.54