Configuration Tool User Manual

1.Primary Functions

Reviewing and configuring device’s parameters

Upgrading device firmware through serial port

2.Introduction to functional sections

1
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689

Parameter configuration area for serial/rs232 port, which is used for connecting the device
and computer. This is the key step which define a successful use for the rest. Before using
this option, please confirm that the device and computer are successfully connected
through the USB interface. Then press Open com. The LED before the device type will

change from to .which indicates the connection is successful. Button used for
query all of the parameter. (parameters in default or newly set parameters)

Parameter configuration area for device unit, which is used for configuring needed value

Software version and protocol area, which showcase the current basic information of the
device.

Upgrade area,which is used for latest firmware upgrade.

User Manual

Restore the default configuration

3.Special status reminder

3.1 Serial port configuration: when you switch the COM port, please reconnect the device and read the parameters
3.2 Firmware upgrade: progress bar indicating. Please pay attention to the bar until it fully reaches 100%

3.3 Parameter Control: Hover your mouse cursor over the blue icon - it gives you instant hint help

2
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689
3.4 Parameter Control: when you start to fill the value , the color of the character will change to red.

The “APPLY” button will change to red either.

3.4 Parameter Control: Select the network route that you want to register first. This is a special option only when you need.
You can choose or shed any of below network at your request.

4. Configuring area guide

A. Quick start guide: After each device leaves the factory, all parameters have a default setting. When you get the
sample and want to use it quickly. Please confirm that at least the following three necessary conditions have been
modified or set up successfully in a way that suits your needs: IP address, port, APN of the SIM. You can find these
three parameters via “Server setting”&”APN setting”.

Now, Let’s take a look at a detailed explanation of each settings area.

3
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689
B. Device Information

Model & SN(IMEI) are read-only elements, and can not be modified.

Name Configure Property Comments

Version version.MCU r Device model version string

IMEI sn r Device Identification String (IMEI)

ICCID SMS r Calling Card Identification


Number (SMS)

C. Report interval setting

4
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689
Name Configure Property Comments

Active-ON reportoninterval rw
Report interval in active state

It defines the data upload time


interval in moving

Active-OFF reportoffinterval rw
Report interval in inactive state

It defines the data upload time


interval in static

Stationary- stationaryackti rw
ACK me The device determines the time
from moving state to stationary
state

It defines the demanded duration


of the device to enter sleeping
mode from the moment it stops
moving.

D. APN setting(LTE/GSM:APN)

Name Configure Property Comments

APN Name apnname rw Name of APN

APN Username apnusername rw Username for APN

5
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689
APN Password apnpassword rw Password for APN

RAT Specify gsmnetwork rw Select the network route that you


want to register first

Duty.ON gsmdutyinterv rw Intermittent transmission interval


al for LTE/GSM module

E. server setting

Name Confi Prop Comments


gure erty

Host ipaddr rw IP-address or domain name of the target server

Port port rw TCP port of the target server

6
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689
F. FTP server setting

Name Configur Property Comments


e

Host ftpipadd rw IP-address or domain name for target


r FTP server

Directory ftpurl rw TCP port for target FTP server

User ftpuser rw Username for FTP server

Password ftppass rw Password for FTP server

G. Phone Number for SOS

Name Configure Property Comments

SOS1 sos1 rw Configure the SOS number you


need, e.g. China Mobile:
+86**********Please note that only
the "+" sign is supported before
the country and area code of the
7
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689
phone number, and "00" is not
supported.

SOS2 sos2 rw ...........................................

H. Bluetooth peripheral

Name Configur Prop Comments


e erty

BTSN1 btsn1 rw Configure the SN number of your Bluetooth


peripheral

BTSN2 btsn2 rw

BTSN3 btsn3 rw

BTSN4 btsn4 rw

BTSN5 btsn5 rw

BTSN6 btsn6 rw

BTSN7 btsn7 rw

BTSN8 btsn8 rw

8
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689
I. Selective function for device unit

Name Configure Propert Comments


y

Vibra device.ctrl.bit[ rw g-sensor enable(tick)/disable(untick) bit


0]

BLE device.ctrl.bit[ rw BLE module enable(tick)/disable(untick) bit


1]

Light1 device.ctrl.bit[ rw Light1 module enable(tick)/disable(untick) bit


2]

Light2 device.ctrl.bit[ rw Light2 module enable(tick)/disable(untick) bit


3]

Ring device.ctrl.bit[ rw LTE/GSM module ring


4] enable(tick)/disable(untick) bit

GSM device.ctrl.bit[ rw GSM module sleep enable(tick)/disable(untick)


Sleep 6] bit

BLE device.ctrl.bit[ rw BLE module sleep enable(tick)/disable(untick)


Sleep 7] bit

LEDOF device.ctrl.bit[ rw LED ON(tick)/OFF(untick) bit


F 9]

TIPS: Please note vibra (g sensor) this option. If this option is selected, the upload interval will be based on
the time set by “Active-on and Active-Off” in the “report interval setting”. If this item is not selected, that is to say,
when G-SENSOR is turned off, the data upload interval will only be uploaded according to the interval set by “ACTIVE-
OFF” in the “report interval setting”.

9
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689
J. Selective emergency events for SMS/Dial alert

Name Configure Property Comments

SOS.s emerg.ctrl.bit[0] rw SOS event sending control bit via SMS

SOS.d emerg.ctrl.bit[1] rw SOS event sending control bit via dialing

Volt.s emerg.ctrl.bit[2] rw Voltage alarm events sending control bit


via SMS

Volt.d emerg.ctrl.bit[3] rw
Voltage alarm events sending control bit
via dialing

Door.s emerg.ctrl.bit[4] rw Door-magnet alarm events sending


control bit via SMS

Door.d emerg.ctrl.bit[5] rw Door-magnet alarm events sending control bit


via dialing

Light.s emerg.ctrl.bit[8] rw Light-alarm event sending control bit via


SMS

Light.d emerg.ctrl.bit[9] rw Light-alarm event sending control bit via


dialing

Vibra. emerg.ctrl.bit[10] rw Vibrating-alarm event sending control bit


s via SMS

Vibra. emerg.ctrl.bit[11] rw Vibrating-alarm event sending control bit


d via dialing

10
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689

K. Selective elements for state query

TIPS: STATE is an SMS command. State query means when you text the STATE command through text functions.

You will get the ticked parameter in the above picture in return.

Name Configure Property Comments

Date sms.state.bit[ rw Date Provide date in the response of


0] the state command

BattR sms.state.bit[ rw Provide battery remains in the


3] response of the state command

Vibra sms.state.bit[ rw Provide control-bit of the g-sensor in


6] the response of the state command

Light1 sms.state.bit[ rw Provide control-bit of the light sensor 1


7] in the response of the state command

Light2 sms.state.bit[ rw Provide control-bit of the light sensor 2


8] in the response of the state command

11
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689
L. Polish CAN function(For TE604E use only)

TIPS:Click Select Parameter to pop up the right function box

The CAN function cannot be empty, at least one should be selected

5.MCU software upgrade


5.1 Upgrade

5.2 Click Upgrade to select the upgrade file

5.3 Select the file, click Start, and wait for the upgrade to succeed

12
深圳市思创捷物联科技有限公司
Shenzhen ThinkPower Technology Co.,Ltd
地址:深圳市宝安区新安街道稻兴环球科创中心 B 座 1215 号 电话:0755-86719689

6.Restore factory default parameters


6.1 Click Factory

6.2 The pop-up window prompts whether to restore the factory settings, click Yes to restore the factory default
parameters, and click No to exit the step