Operator Instruction Doc. No.

1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 1 (69)

Display Description

PWCP
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB

Based on 1CS62774 Author SIT/GKLT/A. Johansson


Product SGT-700 MD Fixed B Appr. 2012-06-12 Jan Bergmark
Doc. Kind Screen layout display
Language en

This document is issued in Pulse.


Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 2 (69)

Contents
PWCP

1 General ...........................................................................................................4
1.1 Purpose of this document
1.2 The SGT-700 displays
1.3 Compressor and Gas Process displays

2 Unit Operation Display..................................................................................5


2.1 General
2.2 Unit Operation Display abbreviations

3 Log Page Display ..........................................................................................9


3.1 General
3.2 Log Page Display abbreviations
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

4 Fuel System Display ...................................................................................15


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

4.1 General
4.2 Fuel System Display abbreviations

5 Lubrication Oil Display ...............................................................................17


5.1 General
5.2 Lubrication Oil Display abbreviations

6 Air Intake Display ........................................................................................19


6.1 General
6.2 Air Intake Display abbreviations

7 Bearings Display .........................................................................................21


7.1 General
7.2 Bearings Display abbreviations

8 Ventilation Display ......................................................................................23


8.1 General
8.2 Ventilation Display abbreviations

9 Emission Control Display...........................................................................25


9.1 General
9.2 Emission Control Display abbreviations

10 Turbine Governing Display ........................................................................27


10.1 General
10.2 Turbine Governing Display abbreviations

11 Ventilation SAC Electrical & Control Module Display .............................30


11.1 General
11.2 Ventilation SAC Electrical & Control Module Display abbreviations

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 3 (69)

12 Start Block and Trips Display ....................................................................32


12.1 General
12.2 Start Block and Trips Display abbreviations

13 Overview Phase 1 & 2, 3, 4 Display ...........................................................38


13.1 General

14 Compressor Control Display .....................................................................40


14.1 General
14.2 Compressor Control Display abbreviations

15 Compressor Bearings Display...................................................................44


15.1 General
15.2 Compressor Bearings Display abbreviations

16 Sealing Gas Compressor Display..............................................................47


16.1 General
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

16.2 Sealing Gas Compressor Display abbreviations


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

17 Anti Surge Control display.........................................................................50


17.1 General
17.2 Anti Surge Control display abbreviations

18 Surge Map Phase 1 & 2, 3, 4 display .........................................................54


18.1 General
18.2 Surge Map Phase 1 display abbreviations

19 Gas Process display ...................................................................................59


19.1 General
19.2 Gas Process display abbreviations

20 Gas Process Gas Coolers display.............................................................62


20.1 General
20.2 Gas Process Gas Coolers display abbreviations

21 Overview Load Sharing display.................................................................65


21.1 General

22 Overview Load Page Gas Process display...............................................67


22.1 General

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 4 (69)

1 General

1.1 Purpose of this document


In the document Human-Machine Interface (HMI) Description, the basic layouts of the
Graphic and Trend displays are described. This document describes the operating displays
used in the SGT-700 plant delivery.

1.2 The SGT-700 displays


The SGT-700 interactive displays are built up of a number of “pages”, each having a
certain purpose. The system displays are based on the Process & Instrumentation
We reserve all rights in this document and in the information

Diagrams (P&ID) included in the Operator Documentation.


contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

1.3 Compressor and Gas Process displays


During the life time of this compressor station, the suction pressure will drop. To always
stay at the same discharge pressure in the future, the setup of the compressors and the gas
process needs to be changed depending on the pressure drop at the suction side. This is the
reason to why the project is divided in four different phases. The control system logic will
change depending on the actual operation phase
The control system logic will cover all four phases. Due to the fact that all software design
shall be done at the same time and to stay to one program, the shifting between the phases
will be done with four selector settings in the software, one for each phase.
There are different HMI displays depending on the actual activated phase1 for the
compressor and the gas-process.

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 5 (69)

2 Unit Operation Display

2.1 General
The Unit Operation display is used during the start-up sequence, normal operation and the
shut down sequence. It includes functions to select turbine controller, fuel-mode and to
start and stop. The display also indicates whether a certain Function Group (FG) is in
operation or not. This is shown in the Start Indication column. The most important values
such as temperature, pressure and process data can also be observed here.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 6 (69)

2.2 Unit Operation Display abbreviations

MIMIC DISPLAY
T0/H0 Ambient air temperature/humidity
T2/P2 Compressor inlet temperature/pressure
T3/P3 Compressor discharge temperature/pressure
T7/P8 Exhaust gas temperature/pressure
GG Speed Gas Generator Speed
PT Speed Power Turbine Speed
Suction Suction Side of Compressor
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

Discharge Discharge Side of Compressor


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

OPERATIONAL MODE
Internal Operation from gas turbine control system
External Operation from customer DCS
Off No operation possible

GOVERNING MODE
Speed mode Activate Speed Mode
SP Internal Speed Setpoint
Load Sharing Mode Load Sharing Mode Activated

COMPRESSOR PHASE
Phase 1 Control System Logic for Design Phase 1 Activated
Phase 2 Control System Logic for Design Phase 2 Activated
Phase 3 Control System Logic for Design Phase 3 Activated
Phase 4 Control System Logic for Design Phase 4 Activated

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 7 (69)

UNIT OPERATION
Ready to Start All start orders are ignored (Start interlock) until the unit is ready for
start.
Preparation Preparation of compressor before start
Start/Stop Function group (FG) for start and stop of GT

START INDICATION
Ventilation Indicates when the ventilation is put into service and purging of all
rooms of the unit is proceeding.
Lub. Oil The lubricating oil system is activated.
Purge/Fuel Pr. The barring starts and purging of the turbine is proceeding and the fuel
system is started.
Pilot Ignition Ignition of pilot flame
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

Main Ignition Ignition of main flames


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Acc With Starter Acceleration of the gas turbine by both start motor and combustion of
fuel.
Acceleration Start motor is stopped and acceleration is carried out by combustion of
fuel.
Turbine In Service Turbine and Gas Compressor in service and unit on Load
Purge Time Indicates the remaining time for the purge sequence.

STOP INDICATION
Start Abort Indicates that the abortion of the start sequence is activated.
UL90 Shutdown An unloading shutdown is initiated. The unit will be unloaded until the
fault disappears or the active load is zero. Maximum 90 second.
UL30 Shutdown An unloading shutdown is initiated. The unit will be unloaded until the
fault disappears or the active load is zero. Maximum 30 second.
Instant Shutdown Indicates that an instant shutdown trip is activated.
Stopping Indicates that the stop sequence is activated.
Warm Turbine Indicates that the cooling down sequence will be activated after a stop
or trip.
Barring
Indicates turning of turbine-shaft.
Cool Down Time
Indicates the remaining time for the cooling down sequence.

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 8 (69)

SEQUENCES
Turb Sequence Turbine sequence
Unit Sequence Main sequence start/stop of unit
Fuel Sequence Gas fuel sequence
Comp Prep Sequence Compressor Preparation Sequence
Comp Sequence Compressor Sequence

T7L Limits the average turbine exhaust temperature. The set point is
calculated according to the ambient air conditions.

NGG Limits the speed of the gas generator rotor. The set point is calculated
according to the ambient air conditions. The limiter uses two setting
levels, one for start and one for service
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

The limiters are presented with one bar graph for the measured value and one for the limiting set point.
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

The limit set point bar graph starts at the top of the diagram and expand downwards by decreasing value.

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 9 (69)

3 Log Page Display

3.1 General
The Log Page displays are used when all possible values needed are presented on one
page. This page is also used when performing a Routine Reading printout. In the figure
below you can overview all the values presented in log page.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 10 (69)

3.2 Log Page Display abbreviations

TURBINE DATA
NGG Rotation speed of the gas generator shaft
NGG* Normalized rotation speed (according to ambient temperature) of the
gas generator shaft
NPT Rotation speed of the power turbine shaft
IGV Inlet guide vane position
Barring Gas Compressor is Barring
Cooling Time Indicates the elapsed time for the cooling down sequence
We reserve all rights in this document and in the information

Cx Factor used to calculate equivalent working hours


contained therein. Reproduction, use or disclosure to third

Compr Inlet DP Compressor inlet differential pressure


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Turb. Inl. Mass Flow Turbine inlet mass flow measurement


Exhaust Pr P8 Exhaust gas pressure
Exhaust Diff Pr Turbine exhaust differential pressure
T2 Compressor inlet temperature
P2 Compressor inlet pressure
T3 Compressor discharge temperature
P3 Compressor discharge pressure
BV1 Bleed valve 1 (control valve)
BV2 Bleed valve 2 (control valve)

HISTORICAL DATA
Starts Total numbers of starts
Operating Hours Total GT operating hours
Equivalent Hours Total GT equivalent operating hours

SEAL GAS PHASE 1, 2 &


3, 4
Ext Seal Gas Supply Ctrl DP External Seal Gas Supply Delta Flow Pressure 1´ST Compressor
(PDIT-2211)
Seal Gas Supply Temperature Seal Gas Supply Temperature 1´ST Compressor
(TIT-2802)
Primary Vent Pressure DE Primary Vent Pressure Driven End 1´ST Compressor
(PIT-2301)

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 11 (69)

Primary Vent Pressure NDE Primary Vent Pressure Not Driven End 1´ST Compressor
(PIT-2303)
Primary Seal Vent Pressure Primary Seal Vent Pressure 1´ST Compressor
(PIT-2311)
Separation Gas Supply Separartion Gas Supply Pressure 1´ST Compressor
Pressure (PIT-2007)

SEAL GAS PHASE 3 & 4


Ext Seal Gas Supply Ctrl DP External Seal Gas Supply Delta Flow Pressure 2&3´ST Compressor
(PDIT-2522)
Seal Gas Supply Temperature Seal Gas Supply Temperature 2&3´ST Compressor
(TIT-2502)
Primary Vent Pressure DE Primary Vent Pressure Driven End 2&3´ST Compressor
(PIT-2513)
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

Primary Vent Pressure NDE Primary Vent Pressure Not Driven End 2&3´ST Compres
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

(PIT-2514)
Primary Seal Vent Pressure Primary Seal Vent Pressure 2&3´ST Compressor
(PIT-2516)
Separation Gas Supply Separartion Gas Supply Pressure 2&3´ST Compressor
Pressure (PIT-2511)

COMPR BEARINGS
PHASE 1, 2 & 3, 4
Compr Vibration DE X 1´ST Compressor vibration Driven End measure point X
(VE1447X)
Compre Vibration DE Y 1´ST Compressor vibration Driven End measure point Y
(VE1447Y)
Compr Vibration NDE X 1´ST Compressor vibration Non Driven End measure point X
(VE1446X)
Compr Vibration NDE Y 1´ST Compressor vibration Non Driven End measure point Y
(VE1446Y)
Axial Displ. Compr 1´ST Compressor Axial Displacement
(VE1445A)
Axial Displ. Compr 1´ST Compressor Axial Displacement
(VE1445B)
Radial Bearing DE Temp 1´ST Compressor Radial Bearing Temperature Driven End
(TE-1441)
Radial Bearing DE Temp 1´ST Compressor Radial Bearing Temperature Driven End
(TE-1442)
Axial Bearing Outb Temp 1´ST Compressor Axial Outboard Bearing Temperature
(TE-1431)

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 12 (69)

Axial Bearing Outb Temp 1´ST Compressor Axial Outboard Bearing Temperature
(TE-1432)
Axial Bearing Inb Temp 1´ST Compressor Axial Inboard Bearing Temperature
(TE-1435)
Axial Bearing Inb Temp 1´ST Compressor Axial Inboard Bearing Temperature
(TE-1436)
Radial Bearing NDE Temp 1´ST Compressor Radial Bearing Temperature Not Driven End
(TE-1439)
Radial Bearing NDE Temp 1´ST Compressor Radial Bearing Temperature Not Driven End
(TE-1440)

COMPR BEARINGS
PHASE 3 & 4
Compr Vibration DE X 2&3´ST Compressor vibration Driven End measure point X
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

(VE1417X)
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Compre Vibration DE Y 2&3´ST Compressor vibration Driven End measure point Y


(VE1417Y)
Compr Vibration NDE X 2&3´ST Compressor vibration Non Driven End measure point X
(VE1416X)
Compr Vibration NDE Y 2&3´ST Compressor vibration Non Driven End measure point Y
(VE1416Y)
Axial Displ. Compr 2&3´ST Compressor Axial Displacement
(VE1415A)
Axial Displ. Compr 2&3´ST Compressor Axial Displacement
(VE1415B)
Radial Bearing DE Temp 2&3´ST Compressor Radial Bearing Temperature Driven End
(TE-1411)
Radial Bearing DE Temp 2&3´ST Compressor Radial Bearing Temperature Driven End
(TE-1412)
Axial Bearing Outb Temp 2&3´ST Compressor Axial Outboard Bearing Temperature
(TE-1401)
Axial Bearing Outb Temp 2&3´ST Compressor Axial Outboard Bearing Temperature
(TE-1402)
Axial Bearing Inb Temp 2&3´ST Compressor Axial Inboard Bearing Temperature
(TE-1405)
Axial Bearing Inb Temp 2&3´ST Compressor Axial Inboard Bearing Temperature
(TE-1406)
Radial Bearing NDE Temp 2&3´ST Compressor Radial Bearing Temperature Not Driven End
(TE-1409)
Radial Bearing NDE Temp 2&3´ST Compressor Radial Bearing Temperature Not Driven End
(TE-1410)

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 13 (69)

GAS FUEL DATA


Gas Fuel Press Gas fuel pressure
Gas Fuel Temp Gas fuel temperature
Pilot Gas Pilot gas heat flow/ Pilot gas fuel valve position
Main Gas Main gas heat flow/ Main gas fuel valve position

BEARINGS
1 GG Radial Temperature and vibration of bearing 1, gas generator
1 GG Axial Temperature of axial bearing, gas generator
2 GG Radial Temperature and vibration of bearing 2, gas generator
3 PT Radial Temperature and vibration of bearing 3, power turbine
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

4 PT Radial Temperature and vibration of bearing 4 ,power turbine


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

4 PT Axial Temperature of axial bearing, Power Turbine.


Axial Displ. GG Axial displacement, gas generator
Axial Displ PT. Axial displacement, power turbine

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 14 (69)

AIR INTAKE
Ambient Temp T0 Ambient air temperature
Humidity H0 Ambient air humidity
DP Air Intake Filter Differential pressure over air intake filter
DP Pre-Filter Differential pressure over Pre-filter
DP High Efficiency Filter Differential pressure over high efficiency filter
Sealing Air Temp Temperature sealing air

LUBRICATION OIL
Bearing 2 DP Differential pressure between lubrication oil pressure and bearing
house pressure in bearing no. 2
Supply Press Oil-supply pressure to all bearings except bearing no 2
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

Supply Temp Oil-supply temperature to all bearings


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Tank Heaters Indication oil heaters in storage tank


Tank Temp Temperature in oil storage tank
Tank Level Oil level in storage tank
Tank Press Pressure in oil storage tank

EXHAUST TEMP T7
XE01 CT005 to CT080 Shows the first ring of measuring points
XE02 CT005 to CT080 Shows the second ring of measuring points
T7 Avg Average exhaust temperature per ring
T7 Avg Total average exhaust temperature
T7 Min To Avg Shows the minimum temperature below average
T7 Max To Avg Shows the maximum temperature above average
T7 Max Start Max average temperature during latest start

COMBUSTOR
PULSATIONS
Low Frequency Low Frequency
High Frequency High Frequency
Narrow Frequency Narrow Frequency

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 15 (69)

4 Fuel System Display

4.1 General
The Fuel System display includes the Gas Fuel System and the Ignition system. For more
information about the systems, see the Process & Instrumentation Diagrams, System
Descriptions and Component Lists.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 16 (69)

4.2 Fuel System Display abbreviations

FUEL SYSTEM
Pilot Ignition FG Pilot ignition function group
FG Gas Fuel Gas fuel function group
Gas Fuel Seq Gas fuel sequence

ENERGY FLOW
Gas Gas fuel heat flow
Total Total fuel heat flow
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

Purge Time Remaining time during purge-step in start-sequence


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

GT MAIN DATA
NGG Rotation speed of the Gas Generator shaft
NPT Rotation speed of the Power Turbine shaft
T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction flow
Suction Temp Suction temperature
Suction Pressure Suction pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 17 (69)

5 Lubrication Oil Display

5.1 General
The Lubrication Oil display includes two systems: the Lube Oil System and the Start
System. The figure below shows the lube oil tank, the lube oil pumps, filters, pipes and
bearings. For more information about the systems, see the Process & Instrumentation
Diagrams, System Descriptions and Component Lists.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 18 (69)

5.2 Lubrication Oil Display abbreviations

LUBE OIL SYSTEM


Lube Oil Lube oil system function group
Purge Purge function group
Barring Barring function group
Compr Wash Compressor wash function group
Cool Init Group 1 Lube oil pump group 1 of 3
Cool Init Group 2 Lube oil pump group 2 of 3
Cool Init Group 3 Lube oil pump group 3 of 3
We reserve all rights in this document and in the information

Indicates that the cooling down sequence will be activated after a stop
contained therein. Reproduction, use or disclosure to third

Warm Turbine
or trip
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Cool down time Shows the remaining cooling down time


Time Until Wash Remaining Time Until Wash Enable

GT MAIN DATA
NGG Rotation speed of the Gas Generator shaft
NPT Rotation speed of the Power Turbine shaft
T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 19 (69)

6 Air Intake Display

6.1 General
The Air Intake display includes the Air Intake and Cooling Air, Instrument Air and Gas
turbine system.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 20 (69)

6.2 Air Intake Display abbreviations

XE01 CT005 TO CT080 Shows the first ring of measuring points


XE02 CT005 TO CT080 Shows the second ring of measuring points
T7 Avg XE01 Average exhaust temperature first ring
T7 Avg XE02 Average exhaust temperature second ring
T7 Avg Total average exhaust temperature
T7 Min to Avg Maximum deviation below average
T7 Max to Avg Maximum deviation above average
T7 Max Start Maximum average temperature during start
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.

GT MAIN DATA
© Siemens Industrial Turbomachinery AB

NGG Rotation speed of the Gas Generator


NPT Rotation speed of the Power Turbine
T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 21 (69)

7 Bearings Display

7.1 General
The Bearings display contains temperature/vibration information about the axial bearings
as well as the radial bearings on the GT.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 22 (69)

7.2 Bearings Display abbreviations

L/O Bearing 2 DP Lubrication oil differential pressure in bearing #2


L/O Supply Press Lubrication oil supply pressure
L/O Supply Temp Lubrication oil supply temperature

GT MAIN DATA
NGG Rotation speed of the Gas Generator shaft
NPT Rotation speed of the Power Turbine shaft
T0 Ambient air temperature
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

T7 Total exhaust average temperature


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Temperature
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 23 (69)

8 Ventilation Display

8.1 General
The Ventilation display shows the position of fire shut off dampers and operation modes
of the fans for the ventilation system.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 24 (69)

8.2 Ventilation Display abbreviations

GG Room Vent Gas turbine room ventilation function group

GAS DETECTION SYSTEM


H Level Gas High Gas Level
HH Level Gas High High Gas Level
Equipment Fault Malfunction of the gas detection equipment

FIRE SYSTEM
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

Warning Fire warning


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Trip Fire trip


Equipment Fault Malfunction of the fire detection equipment
CO2 Blocked The release of CO2 is blocked
CO2 Released The CO2 has been released
Dampers Closed Fire shut off dampers closed

GT MAIN DATA
NGG Rotation speed of the Gas Generator shaft
NPT Rotation speed of the Power Turbine shaft
T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 25 (69)

9 Emission Control Display

9.1 General
This display shows the emission process. Compressed air is mixed with gas fuel and burnt
in the combustion chamber producing hot gas at high velocity as input to the gas turbine.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 26 (69)

9.2 Emission Control Display abbreviations

EMISSION CONTROL
Disable Bypass Control Disables control of bypass valves
Disable BV2 Emis. Ctrl Disables emission control for bleed valve 2
SP Bypass Area Calculated set point bypass area
MV Bypass Area Calculated measured value bypass area
Calc. Flame Temp Calculated flame temperature

GT MAIN DATA
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

NGG Rotation speed of the Gas Generator shaft


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

NPT Rotation speed of the Power Turbine shaft


T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 27 (69)

10 Turbine Governing Display

10.1 General
The Turbine Governing display shows the turbine governor in operation.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 28 (69)

10.2 Turbine Governing Display abbreviations

TURBINE GOVERNING
FSC SP Set point for flame sustain control
STC SP G Set point to the start controller
STC O SP Offset to the start controller, manually set by the operator
MPC MV Measured value of the max position controller. Fuel control tests, gas
fuel.
MPC O SP Set point of the max position controller. Fuel control tests, gas fuel.
GAC SP Set point of the gas generator acceleration controller (limiter)
We reserve all rights in this document and in the information

PAC Power turbine accelerator controller


contained therein. Reproduction, use or disclosure to third

SC Controls the speed of the gas generator


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

T7L Exhaust temperature controller (limiter)


NGGL Gas generator speed limiter
MPPRC Maximum Primary Pressure Ratio Controller
MMPRC Maximum Main Pressure Ratio Controller
MIN Minimum selector
MAX Maximum selector
Split Range Control Controls the relation between main and primary gas to minimize NOx
Split Range Control PFR Function of active power used to minimize NOx emissions with stable
flame.
Split Range Control CFR Split range control Central Fuel Ratio
Pilot Valve Pilot gas fuel control valve
Pilot Valve MJ Energy flow through the pilot gas fuel control valve
Pilot Valve SP Set point of the pilot gas fuel control valve
Pilot Valve MV Pilot gas fuel control valve position
Pilot Valve Dev Deviation from SP and position of primary gas valve
Main Valve Main gas fuel control valve
Main Valve MJ Energy flow through the main gas fuel control valve
Main Valve SP Set point of the main gas fuel control valve
Main Valve MV Main gas fuel control valve position
Main Valve Dev Deviation from SP and position of main gas valve
Central Valve Central gas fuel control valve
Central Valve MJ Energy flow through the central valve. (MJ=Mega Joule)

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 29 (69)

Central Valve MV Central valve measured value


BV1 MV Bleed valve 1 measured value
BV 1 SP Set point for bleed valve 1 for test purpose, only possible to set during
standstill
BV2 MV Bleed valve 2 measured value
BV2 SP Set point for bleed valve 2 for test purpose, only possible to set during
standstill
IGV MV Inlet guide vane measured value
IGV SP Set point for inlet guide vane

GAS
Pilot Test SP Set point for pilot gas fuel valve for test purpose, only possible to set
during standstill
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

Main Test SP Set point for main gas fuel valve for test purpose, only possible to set
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

during standstill
Central Test SP Set point when testing Central Fuel Valve

GT MAIN DATA
NGG Rotation speed of the Gas Generator shaft
NPT Rotation speed of the Power Turbine shaft
T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 30 (69)

11 Ventilation SAC Electrical & Control Module Display

11.1 General
The E&C display picture shows the ventilation fans, shut off dampers and differential
pressure for the control and battery room.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 31 (69)

11.2 Ventilation SAC Electrical & Control Module Display abbreviations

FIRE SYSTEM
Warning Common fire pre alarm for the control module
Trip Fire detected in the control module
Equipment Fault Fire system fault
CO2 Released Fire system has released it’s CO2
Dampers Closed Dampers closed due to fire detected

GT MAIN DATA
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

NGG Rotation speed of the Gas Generator shaft


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

NPT Rotation speed of the Power Turbine shaft


T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 32 (69)

12 Start Block and Trips Display

12.1 General
The Start Block and Trips display shows possible active start blocking alarms and possible
active shutdowns. The different kinds of start blocks are; Start blocking alarms, Start
abort, Instant shutdown, Blow down, Unloading 90, Unloading 30 and Hard Wired
Click on the different blocks for detailed signal information.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 33 (69)

12.2 Start Block and Trips Display abbreviations

MIMIC DISPLAY
Startblock AL Start blocking alarms
Start Abort Shutdown during start-up and stand still. (Blocked during operation)
InstantSD Instant shutdown. Instant closing of fuel valves and closing of Suction
and Discharge valves.

Unload90 Shutdown with unloading during 90s (ramp rate is from full load to
zero in 90s) before Instant shutdown is activated. If the trip condition
disappears during the unloading, the shutdown is aborted and the GT
stays at current speed.
We reserve all rights in this document and in the information

Unload30 Shutdown with unloading during 30s (ramp rate is from full load to
contained therein. Reproduction, use or disclosure to third

zero in 30s) before Instand shutdown is activated. If the trip condition


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

disappears during the unloading, the shutdown is aborted and the GT


stays at current speed
SD Comp Compressor shutdown. Instant closing of fuel valves and closing of
Suction and Discharge valves. If Blowdown Shutdown
depressurization of compressor through blowdown valves
SD G-P Gas Process shutdown. Instant closing of fuel valves and closing of
Suction and Discharge valves. If Blowdown Shutdown
depressurization of compressor through blowdown valves
HW Trips Bentley Nevada Shutdowns
Acknowledge Safety I/O Reset of safety I/O
Safety Relay Can be Energized if no shutdowns activated

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


34 (69)
Page

PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


35 (69)
Page

PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


36 (69)
Page

PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


37 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 38 (69)

13 Overview Phase 1 & 2, 3, 4 Display

13.1 General
This view is showing the total gas-process design around the compressor. During the life
time of this compressor station, the suction pressure will drop. To always stay at the same
discharge pressure in the future, the setup of the compressors and the gas process needs to
be changed depending on the pressure drop at the suction side. This is the reason to why
the project is divided in four different phases. There are 3 different displays the first one is
showing phase1 and 2 the other two are showing phase 3 and 4.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


39 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 40 (69)

14 Compressor Control Display

14.1 General
The displays are showing the controllers and limiters for the compressor. For more
information about the compressor controlling and limitations see doc 1CS110859. There
are different HMI-displays depending on the actual activated phase for the project.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


41 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 42 (69)

14.2 Compressor Control Display abbreviations

SPEED CTRL
Speed SP Speed Set Point
Pigging CTRL Pigging controlling

LIMITERS
Compr Train Std Suction Compressor standard Flow Suction Flow Limiter
Flow Limiter
Compr Train Std Suction Compressor standard Flow Suction Flow Limiter Set Point
Flow Limiter SP
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

Compr Train Std Suction Compressor standard Flow Suction Flow Limiter Measured Value
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Flow Limiter MV
Compr Train Suction Compressor Train Suction Pressure Limiter
Pressure Limiter
Compr Train Suction Compressor Train Suction Pressure Limiter Set Point
Pressure Limiter SP
Compr Train Suction Compressor Train Suction Pressure Limiter Measured Value
Pressure Limiter MV
Compr Train Discharge Compressor Train Discharge Pressure Limiter
Pressure Limiter
Compr Train Discharge Compressor Train Discharge Pressure Limiter Set Point
Pressure Limiter SP
Compr Train Discharge Compressor Train Discharge Pressure Limiter Measured Value
Pressure Limiter MV

LOAD SHARING
CONTROLLER
Station Flow Controller Station Flow Controller
Station Flow Controller SP Station Flow Controller Set Point
Station Flow Controller MV Station Flow Controller Measured Value
Station Discharge Pressure Station Discharge Pressure Controller
Controller
Station Discharge Pressure Station Discharge Pressure Controller Set Point
Controller SP
Station Discharge Pressure Station Discharge Pressure Controller Measured Value
Controller MV

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 43 (69)

Station Suction Pressure Station Suction Pressure Controller


Controller
Station Suction Pressure Station Suction Pressure Controller Set Point
Controller SP
Station Suction Pressure Station Suction Pressure Controller Measured Value
Controller MV

OPERATIONAL MODE
Internal Operation from gas turbine control system
External Operation from customer drive control system DCS
Backup Operation from backup panel
Off No operation possible
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

GOVERNING MODE
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Speed Mode Speed Controller


Load Sharing Mode Load sharing Controller

SEQUENCES
Comp Sequence Compressor Sequence
Comp Prep Sequence Compressor Preparation Sequence

GT MAIN DATA
NGG Rotation speed of gas generator shaft.
NPT Rotation speed of power turbine shaft.
T0 Ambient temperature.
T7 Exhaust temperature.
P3 Compressor discharge pressure.

COMPRESSOR MAIN DATA


Suction Flow Suction Flow.
Suction Temp Suction Temperature.
Suction Pressure Suction Pressure.
Dis Flow Discharge Flow.
Dis Temp Discharge Temperature.
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 44 (69)

15 Compressor Bearings Display

15.1 General
This display shows temperature/vibration information for bearings on the compressor.
There are different HMI-displays depending on the actual activated phase for the project.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


45 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 46 (69)

15.2 Compressor Bearings Display abbreviations

GT MAIN DATA
NGG Rotation speed of the Gas Generator shaft
NPT Rotation speed of the Power Turbine shaft
T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

Suction Flow Suction Flow


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Suction Temp Suction Temperature


Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 47 (69)

16 Sealing Gas Compressor Display

16.1 General
The Sealing Gas Compressor display shows the compressor sealing, separation gas system
and the seal gas system. There is one seal gas system for stage 1 on the compressor and
one seal gas system for stage 2 and 3. There are different HMI-displays depending on the
actual activated phase for the project.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


48 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 49 (69)

16.2 Sealing Gas Compressor Display abbreviations

Confirm Ext Seal Gas Valve Confirm External Seal Gas Valve is Opened
Open
Separation Gas FG Separation Gas Function Group
Seal Gas FG Seal Gas Function Group
Comp Pressurized and Ready Compressor Pressurized and Ready to be started
to Start
Confirm Manually Drain Confirm Manually Drain of Compressor
Compressor Preparation Compressor Preparation Sequence
Sequence
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.

GT MAIN DATA
© Siemens Industrial Turbomachinery AB

NGG Rotation speed of the Gas Generator shaft


NPT Rotation speed of the Power Turbine shaft
T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 50 (69)

17 Anti Surge Control display

17.1 General
This display shows the anti surge control system. Depending on the actual phase, the
compressor and gas-process will change; this affects the anti surge amount of anti surge
controllers. There are different HMI-displays depending on the actual activated phase for
the project.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


51 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 52 (69)

17.2 Anti Surge Control display abbreviations

CONTROLLERS
Open Speed SP Open speed set point
Close Speed SP Close speed set point
Man SP Set point for manual operation of anti surge valve
ASC Anti Surge Controller
Ramp Surge controller ramping
Forced Open Surge control valve forced to open position
MAX Maximum selector
We reserve all rights in this document and in the information

Discharge Pressure Limiter


contained therein. Reproduction, use or disclosure to third

Disch Pressure Limit


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Such Pressure Limit Suction Pressure Limiter


Performance CTRL Performance Controller
Pigging CTRL Pigging Controller

ANTI SURGE CONTROLLER


Asc Started Indication anti surge controller active
Surge Margin Surge margin
Forced Open Active Indication anti surge valve forced to open position
Reset Forced Open Manual reset of forced opened anti surge valve

GT MAIN DATA
NGG Rotation speed of the Gas Generator
NPT Rotation speed of the Power Turbine
T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 53 (69)

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 54 (69)

18 Surge Map Phase 1 & 2, 3, 4 display

18.1 General
At this view it is possible to supervise where at the surge map the compressor is operating
and how far from surge the actual operation point is. There are different Surge Maps for
the different compressor stages and depending on the actual operating phase.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


55 (69)
Page

PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


56 (69)
Page

PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


57 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 58 (69)

18.2 Surge Map Phase 1 display abbreviations

Suction Norm Vol Flow Suction Normalized Volume flow


Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Discharge Pressure Discharge Pressure
Discharge Temp Discharge Temperature
ASCV Set Point Anti Surge Controlling Valve Set Point
ASCV Position Anti Surge Controlling Valve Postion
Polytrophic Head Norm Polytrophic Head Normalized
We reserve all rights in this document and in the information

ASC Surge Margin Anti Surge Controlling Marginal


contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.

ASCV Reset Forced Opened Anti Surge Controlling Valve Reset Forced Open
© Siemens Industrial Turbomachinery AB

ASCV SP Man Mode Anti Surge Controlling Valve Manuel Mode


ASCV Opening Speed Anti Surge Controlling Valve Opening Speed
ASCV Closing Speed Anti Surge Controlling Valve Closing Speed

GT MAIN DATA
NGG Rotation speed of the Gas Generator
NPT Rotation speed of the Power Turbine
T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 59 (69)

19 Gas Process display

19.1 General
This view is showing the total gas-process design around the compressor. During the life
time of this compressor station, the suction pressure will drop. To always stay at the same
discharge pressure in the future, the setup of the compressors and the gas process needs to
be changed depending on the pressure drop at the suction side. This is the reason to why
the project is divided in four different phases. There are 3 different displays the first one is
showing phase1 and 2 the other two are showing phase 3 and 4.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


60 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 61 (69)

19.2 Gas Process display abbreviations

GT MAIN DATA
NGG Rotation speed of the Gas Generator
NPT Rotation speed of the Power Turbine
T0 Ambient air temperature
T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

Suction Flow Suction Flow


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Suction Temp Suction Temperature


Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 62 (69)

20 Gas Process Gas Coolers display

20.1 General
Depending on the phase of the project the 12 gas cooler fans will be used in different
blocks. These blocks are showed at these HMI-displays.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


63 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 64 (69)

20.2 Gas Process Gas Coolers display abbreviations

GAS PROCESS GAS


COOLERS
Gas Cooler Fans FG Gas Cooler Fans Function Group
Gas Cooler Louvers FG Gas Cooler Louvers Function Group
Set Point Gas Cooler Fans Set Point Gas Cooler Fans Outlet Temperature
Outlet Temp

GT MAIN DATA
NGG Rotation speed of the Gas Generator
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

NPT Rotation speed of the Power Turbine


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

T0 Ambient air temperature


T7 Total exhaust average temperature
P3 Compressor discharge pressure

COMPRESSOR MAIN DATA


Suction Flow Suction Flow
Suction Temp Suction Temperature
Suction Pressure Suction Pressure
Dis Flow Discharge Flow
Dis Temp Discharge Temperature
Dis Pressure Discharge Pressure

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 65 (69)

21 Overview Load Sharing display

21.1 General
These displays are showing basic views for the total gas-process around the both
compressor trains. Both compressor trains are seen at the same display to easy supervise
the load sharing control. There are different displays depending on the actual phase of the
project.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


66 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 67 (69)

22 Overview Load Page Gas Process display

22.1 General
The Log Page for the Gas Process is showing almost all values for the gas process. There
are different log pages depending on the actual phase of the project.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


Operator Instruction

Display Description
A
Doc. No.

Rev. ind.

E /& FC101
1CS120852

Techn. Area / DCC

Siemens Industrial Turbomachinery AB


68 (69)
Page

PWCP / BD000034
Operator Instruction Doc. No.
1CS120852
Rev. ind.
A
Techn. Area / DCC Page
Display Description
E /& FC101 69 (69)

REVISION
Rev. Page (P) Description Date
ind. Chapt. (C) Dept. / Init.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


PWCP / BD000034

You might also like