Technical Service Bulletin TSB-2013-01-VE-013

Manufacturer Product Line Engine Model Page


Volvo Excavator D7D EDE2 1 of 1
Component Group Model Series Date
Engine EC210BLC 16-------- 31.01.2013
Subject
To share knowledge about engine hunting in electrical problem.

Failure/Problem

Engine hunting.

Symptom

Error code 128 PID 102 4 was appeared, after key switch ON position. And the engine RPM was dropped
1100 while relief operation at H mode. No smoke emitted and the above case problem sometime.

History

Nothing special case.

Cause & analysis

The error code 128 PID 102 4 concerned with boost pressure sensor.
The error code set, when the - Sensor is defected
- Supply volt short circuit to frame ground
- Socket loosen

Action

Thus we changed the sensor, but nothing changes. We also checked the cable near its socket but the all
cable is abnormal, so we checked the wiring diagram SCH-17 and found the engine oil pressure sensor and
boost pressure sensor were contacted to each other. So we checked the cable on engine oil pressure
sensor and all of cables were worn out. Repaired it and tested the machine, no error code was set and
engine hunting problem was OK.

Part number responsible Part number replaced


Parts no. Description Qty Parts no. Description Qty

Picture

Remark

Prepared by: Yan Myo Paing Title: Junior Mechanic


Acknowledged by: U Aung Toe Title: Section Head
Company: UMG Myanmar (PHK)

Disclaimer:
This Technical Service Bulletin cannot guarantee the accuracy of all information.
Please confirm the information with an appropriate manual.

You might also like