Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Hill-Rom®

VersaCare® Integrated Bed System


with P500 Surface

Safe Skin

No Falls

Surface Protection

No Injuries

Connectivity

Born CMS Ready.


Your patient’s protection and healing are important. Now, with the new CMS guidelines,
providing safe and effective care is critical. The VersaCare® bed was designed to help
deliver better care.
The VersaCare® bed with P500 surface can help manage the mobility, skin care and comfort needs of Med-Surg
patients. The VersaCare® bed with P500 surface can create a safer environment for both you and your patients,
and can be an integral part of Hill-Rom’s Safe Skin™, No Falls™ and No Injuries programs.
Hill-Rom®
VersaCare® Integrated Bed System
with P500 Surface

The P500 surface integrated with the VersaCare® Bed System is designed
to enhance patient and caregiver safety with its unique features:
• Lowest bed height of any acute care bed on the market • Advanced Bed Exit System customizable to patient
• LowChair® position with one-button activation position, alert volume and alert sound
maintains low bed height while in chair position • Obstruction detection both stops and raises the bed if
• Automatic surface adjustments based on patient’s an object is detected
unique body features and position in bed • Battery backup for all bed articulations
• FlexAFoot™ feature decreases need to pull patient up in bed • Zero gaps for easier patient transfers
• One step CPR level flattens frame and max inflates surface • Accurate, integrated bed scales

Connectivity NaviCare® Platform … to the nurse station

When combining the Connect …


Hospital Network Enhance
VersaCare® bed with the At the bedside Outcomes
NaviCare® Patient Safety* … directly to the caregiver
module, Hill-Rom
makes it easy for caregivers
to be better informed.
* Available with Hill-Rom NurseCall … directly to HIS/EMR
Module NCM (3.4 or 4.0) or Patient
• ADT information
Safety systems. Contact your Hill-Rom
• Risk Assessments
representative for details. • Head of bed angle
• Patient Weight, etc.

Surface Protection
The VersaCare® P500 surface • Superior, patented technology that provides surface
Clean
features nano Ag+® technology protection
embedded in the surface ticking • Kills >99.9% of stain and odor-causing bacteria that
that kills stain and odor-causing can affect the surface
bacteria on the surface.
• No known toxicity or allergic reactions
Safe
• No known disposal or handling concerns

Long-lasting • Lasts for the expected life of the product

Cost-effective • Protects the surface for less than a quarter a day


The VersaCare® Bed System with the P500 Surface can help create
a safer environment for you and your patients by supporting
Hill-Rom’s SafeSkin™, No Falls™, and No Injuries Programs.

Safe Skin™ Advanced Microclimate™ technology


The VersaCare P500 surface supports the
Safe Skin™ program by helping to prevent
and treat Stage I-IV pressure ulcers through
a combination of:

• Weight-based pressure redistribution


• Shear and friction management
• Advanced Microclimate™ technology —
the next generation low air loss

A precise flow rate moves air horizontally under the surface


and exits at the head end to prevent heat build up.

No Injuries
The VersaCare® bed System
integrated with the P500 surface
helps take the burden of moving
patients with:

• Rapid Turn Assist


• Boost® feature
• X-ray cassette sleeve

Boost® feature X-ray cassette sleeve

No Falls™
The VersaCare® bed integrated
with the P500 surface features
new SafeView™ local alert, so,
at a glance, you can see if your
safety protocols are set.

SafeView™ alerts
Hill-Rom®
VersaCare® Integrated Bed System
with P500 Surface

Technical Specifications
Bed height Caster and braking system
Low position – surface edge to floor...................................................................... 18" (45.7 cm) Optional IntelliDrive® power transport.....................................................................................Yes
with optional IntelliDrive® power transport ...................................................... 22" (55.9 cm) Caster diameter.......................................................................................................... 5" (12.7 cm)
Maintains low height when placed in chair.............................................................................Yes with IntelliDrive® power transport........................................................................ 6" (15.2 cm)
High position – surface center to floor................................................................... 37" (94.0 cm) Four-wheel braking...................................................................................................................Yes
Headboard/push handles maintain same height regardless of patient surface height..........Yes Brakes lock both rolling and swiveling.....................................................................................Yes
Sleep surface Optional light alerts
Surface thickness....................................................................................................... 8" (20.3 cm) Feature indicators............Low low bed/chair, siderails down, brake not set, bed exit not armed
Width.................................................................................................................... 35.5" (90.2 cm) Optional bed exit alarm system
Length, fully extended........................................................................................... 86" (218.0 cm) Sensitivity levels........................................................................................................................... 3
Length, fully retracted........................................................................................... 75" (191.0 cm) Modes......................................................................................... Positioning, Exiting, Out-of-Bed
Radiolucent sleep deck...............................................................................................................No Optional scale system
Overall width Accuracy....................................................................................................... 1% of patient weight
Siderails stowed....................................................................................................... 37" (94.0 cm) Weigh in any position (except Trend/Rev Trend)......................................................................Yes
Siderails up............................................................................................................. 40" (102.0 cm) Scale weight capacity.......................................................................................... 500 lbs (227 kg)
Overall length Patient controls
Fully extended....................................................................................................94.5" (240.0 cm) Siderail patient bed controls.............................................................................................Standard
Fully retracted.....................................................................................................82.5" (210.0 cm) Docking pendant.............................................................................................................. Optional
Bed angles SideCom® patient communication controls
Head section........................................................................................................................ 0°-65° (Nurse call, universal TV/radio, and lighting) ................................................................. Optional
Knee gatch........................................................................................................................... 0°-16° Electrical characteristics
Foot section.......................................................................................................................... 0°-27° Backup battery power......................................................................................................Standard
Max Trend/reverse Trend.................................................................................................. 15° / 10° Safety listings............................................................................................ UL2601 & IBC 60601-1
Head and Trend angle indicators...............................................................................................Yes

VersaCare A.I.R.® Surface Upgrade


VersaCare
VersaCare A.I.R.®
VersaCare® Rental Capital
to VC900 Series
A.I.R.® to
VC800 Series
P500 Options: VCP500 VC800 Series VC900 Series P3218A P3219A P3220A
(rev A-E) (rev G,H)
SafeSkin™ Advanced Not available Not available
Program Microclimate™ 3 3 3 3
technology
(AMT)
No Falls™ SafeView™ alerts Option Option Separate Separate Separate
Program 3 upgrade upgrade upgrade
Patient helper & Option Option Separate Separate Separate
traction adaptor 3 upgrade upgrade upgrade
No Injuries X-Ray cassette Not available Not available
Program sleeve 3 3 3 3
Surface nano Ag+®
Protection technology 3 3 3 3 3 3
Connectivity NaviCare® Patient Option Option Separate Separate Separate
Safety ready 3 upgrade upgrade upgrade

Hill-Rom reserves the right to make changes without


notice in design, specifications and models. The only
warranty Hill-Rom makes is the express written warranty
extended on the sale or rental of its products.

© 2009 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. USA 800-638-2546


Canada 800-267-2337
158303 rev 1 4/24/09 www.hill-rom.com

You might also like