TOP RAIL CAPS SHALL BE STEEL LOOP CAPS

PERMANENTLY FASTENED TO ALL LINE AND


CORNER POST WITH MINIMUM OF THREE
(3)-1/4" x 1" LONG HEX HEAD SELF- TAPPING
SCREWS EVENLY SPACED AROUND POST.

TOP RAIL SHALL BE MINIMUM OF 1 5/8"


O.D. (NOM. DIA.) PIPE WITH MINIMUM 9
GAUGE CLIPS MINIMUM OF 24" O.C.

2" CHAIN-LINK FENCE WITH FULL


SCREEN MESH (WOVEN FABRIC) NO.
CORNER POSTS: 3" O.D. 9 GAUGE OR HEAVIER GALVANIZED CONNECT FABRIC TO LINE POSTS
GALVANIZED PIPE TUBING AFTER WEAVING BY THE HOT DIP WITH 9 GAUGE CLIPS @ 14" O.C.
@ 5.79 # PER LIN. FT. PROCESS (ASTM-A392)
LINE POSTS SHALL BE SPACED NOT
6'-0"

TO EXCEED (10) TEN FT. AND SHALL


BE MINIMUM OF 2-3/8" O.D.
GALVANIZED PIPE @ 2.72# PER LIN. FT.
CONNECT FABRIC TO TENSION
WIRE WITH 11 GAUGE HOG
BOTTOM TENSION WIRE SHALL BE
CONNECT FABRIC TO CORNER, RINGS @ 24" O.C.
7 GAUGE CLASS III.
TERMINAL AND GATE POSTS
USING 1/4" x 3/4" TENSION BARS
TIED TO POSTS 14" O.C. WITH 11
30" MIN.

GAUGE 7/8" STEEL BANDS AND


5/16" DIA. NUTS AND BOLTS

CORNER ALL POSTS SHALL BE EMBEDDED IN LINE


POST GROUND OR ASPHALT SURFACES (NOT POST
ANCHOR PLATES/BOLTS MOUNTED TO
GROUND SURFACE) UNLESS DIRECTED
OTHERWISE BY OWNER'S REPRESENTATIVE.

NOTES:
1. WHERE BREAKS IN PROFILE OF FENCE TOP ARE NECESSARY IN ROUGH
TERRAIN THEY SHALL BE MADE IN THE LEAST NUMBER OF INTERVALS
PRACTICAL. BREAKS SHALL BE SPREAD OVER VERTICAL CURVES OF
SUFFICIENT LENGTHS TO ENSURE A PLEASING APPEARANCE.
2. FENCE SHALL BE SCREENED AS NOTED IF REQUIRED BY OWNER

DETAIL - TYPICAL
TEMPORARY CONSTRUCTION FENCE
1 SCALE: NO SCALE

Revised Date:
CONSTRUCTION ADMINISTRATION:
03/24/2023
DESIGN GUIDELINES Scale:

Drawing Title: NONE


413 Cahaba Circle TYPICAL TEMPORARY Drawing Number:
Tuscaloosa, Alabama 35404
Phone: (205) 348-5950 CONSTRUCTION FENCE DETAIL
Web: constructionadministration.ua.edu 01 56 26