TABLE OF CONTENTS SAVE THESE INSTRUCTIONS
SAVE THESE INSTRUCTIONS 2 This manual contains important instructions that should
SAFETY3 be followed during installation and maintenance of the
ANSI SAFETY DEFINITIONS generator. Read and understand all instructions in the
manual before starting and operating the generator.
SPECIFICATIONS4
GENERATOR USING THIS MANUAL
ENGINE Congratulations on your choice of a WINCO generator.
INTRODUCTION5 You have selected a high-quality, precision-engineered
generator designed and tested to give you years of
TESTING POLICY
satisfactory service.
INTENDED USES
RESTRICTED USES To get the best performance from your new generator, it is
UNIT CAPABILITIES 6 important that you carefully read and follow the operating
GENERATOR CONNECTIONS instructions in this manual.
STARTING ELECTRIC MOTORS Should you experience a problem please follow the
Load Types “Troubleshooting Tables” near the end of this manual.
PREPARING THE UNIT 7 The warranty listed in the manual describes what you can
UNPACKING expect from WINCO should you need service assistance in
the future.
LUBRICATION
OIL RECOMMENDATIONS
DIESEL FUEL
BATTERY INSTALLATION
LIFTING EYE INSTALLATION
OPTIONAL DOLLY KIT
INITIAL START UP 10
BASIC OPERATION
STARTING HINTS
STOPPING
CONNECTING THE LOADS 11
APPLYING THE LOADS
GROUNDING
WIRING
YOURGEN 13
ENGINE CARE 15
MAINTENANCE SCHEDULE
CHANGING THE OIL
CHECKING THE OIL LEVEL
AIR FILTER
GENERATOR CARE 17
EXERCISING THE GENERATOR
GENERATOR MAINTENANCE
CLEANING
TROUBLESHOOTING18
WIRING DIAGRAM 19
CA EVAP EMISSION CONTROL 20
LIMITED WARRANTY 20
OPM-133/E 2
SAFETY
This engine generator set has been designed and D. Keep a fire extinguisher nearby and know its proper
manufactured to allow safe, reliable performance. Poor use. Fire extinguishers rated ABC by NFPA are
maintenance, improper or careless use can result in appropriate.
potentially deadly hazards; from electrical shock, exhaust E. Store fuel only in an approved container, and only in
gas asphyxiation, or fire. Please read all safety instructions a well ventilated area.
carefully before installation or use. Keep these instructions F. Follow local codes for closeness to combustible
handy for future reference. Take special note and follow all material.
warnings on the unit labels and in the manuals.
3. DEADLY EXHAUST GAS -
CALIFORNIA PROPOSITION 65
WARNING: This product contains crude oil, Exhaust fumes from any gasoline engine contain carbon
gasoline, diesel fuel and other petroleum monoxide, an invisible, odorless and deadly gas that must
be mixed with fresh air.
products, Antifreeze to which can expose
you to chemicals including toluene and A. Operate only in well ventilated areas.
benzene, Ethylene glycol (ingested) B. Never operate indoors including attached garages
which are known to the State of California to cause C. Never operate the unit in such a way as to allow
cancer, birth defects or other reproductive harm and exhaust gases to seep back into closed rooms (i.e.
developmental issues. through windows, walls, floors).
For more information go to www.P65Warning.ca.gov.
4. NOISE HAZARD -
ANSI SAFETY DEFINITIONS Excessive noise is not only tiring, but continual exposure
can lead to loss of hearing.
DANGER
Indicates an imminently hazardous situation which, if A. Use hearing protection when working around this
not avoided, will result in death or serious injury. equipment for long periods of time.
B. Keep your neighbors in mind when using this
equipment.
WARNING
Indicates a potentially hazardous situation which, if 5. CLEANLINESS -
not avoided, could result in death or serious injury.
Keep the generator and surrounding area clean.
CAUTION A. Remove all grease, ice, snow or materials that create
Indicates a potentially hazardous situation which, if slippery conditions around the unit.
not avoided, may result in minor or moderate injury. It B. Remove any rags or other materials that could create
may also be used to alert against unsafe practices. a potential fire hazard.
C. Carefully clean up any gas or oil spills before starting
the unit.
1. ELECTRICAL SHOCK -
6. SERVICING EQUIPMENT -
The output voltage present in this equipment can cause
fatal electric shock. This equipment must be operated by a All service, including the installation or replacement of
responsible person. service parts, should be performed only by a qualified
technician.
A. Do not allow anyone to operate the generator
without proper instruction. A. Use only factory approved repair parts.
B. Guard against electric shock. B. Do not work on this equipment when fatigued.
C. Avoid contact with live terminals or receptacles. C. Never remove the protective guards, covers, or
D. Use extreme care if operating this unit in rain or receptacle panels while the engine is running.
snow. D. Use extreme caution when working on electrical
E. Use only three-pronged grounded receptacles and components. High output voltage from this
extension cords. equipment can cause serious injury or death.
F. Be sure the unit is properly grounded to an external E. Always avoid hot mufflers, exhaust manifolds, and
ground rod driven into the earth. engine parts. They can cause severe burns instantly.
F. The use of the engine-generator set must comply
2. FIRE HAZARD - with all national, state, and local codes.
Gasoline and other fuels present a hazard of possible
explosion and/or fire.
GENERATOR
Generator Manufacturer Mecc Alte Spa
Generator Model Number S16W-130/A
Part Number 16346-006
Rotor Resistance 3.95 Ohms
Stator Resistance 0.360 Ohms
Cap Winding Resistance 0.60 Ohms
Capacitor 25 mF
Capacitor Part Number 16346-612
ENGINE
Engine Manufacturer Kohler
Engine Model Number KD440
Fuel Type Diesel
Oil Capacity 41.6 oz. (1.3 qts)
OPM-133/E 4
INTRODUCTION
TESTING POLICY
Before any generator is shipped from the factory, it is fully
checked for performance. The generator is loaded to its
full capacity, and the voltage, current, and frequency are
carefully checked.
INTENDED USES
This engine generator set has been designed primarily for
portable heavy duty commercial use. Both 120 volt and 240
volt receptacles are provided in the control panel to plug
in your loads (lights, portable tools, and small appliances).
These units are dual wound generators, therefore the
120 volt loads must be equally split with 1/2 of the rated
capacity available on each of the two 120 volt circuits.
RESTRICTED USES
DO NOT operate generator where it could get wet or have
pooling water near it. This generator is NOT weatherproof.
Failing to keep generator in a dry area may cause an
electrical shock, resulting in injury or death.
5 OPM-133/E
UNIT CAPABILITIES
Self-exciting generators respond to severe overloading
GENERATOR CONNECTIONS differently than utility power. When overloaded, the engine
is not able to supply enough power to bring the electric
W6010: 120 Volt and 240 Volt receptacles are provided motor up to operating speed. The generator responds with
for connection to various loads. The following diagram high initial starting current, but the engine speed drops
represents this 5,160 watt (rated output) generator. A & sharply. The overload may stall the engine. If allowed to
B represent the 120 volt output legs of this generator. Up operate at very low speeds, the electric motor starting
to 2,580 watts at 120 volts (43 Amps) can be drawn from winding will burn out in a short time. The generator
the receptacles attached to either A or B output legs. This winding may also be damaged.
generator is capable of producing 21.5 Amps of 240 volt
current at C. Check the appliance or tool nameplates for the CAUTION: EQUIPMENT DAMAGE
current and voltage to insure compatibility. Remember that
power taken from C reduces the power available equally at Running the generator set under these conditions may
both A and B and vice versa. result in damage to the generator stator as well as the
motor winding.
OPM-133/E 6
PREPARING THE UNIT
UNPACKING OIL RECOMMENDATIONS
CAUTION: EQUIPMENT DAMAGE Outdoor temperatures determine the proper oil viscosity for
the engines. Winco recommends our 5W-30 fully synthetic
Always check oil level prior to use. Failure to maintain oil to give you excellent protection in cold temperatures
the engine oil at the proper level will result in serious while maintaining excellent performance in warmer
engine damage. weather.
LUBRICATION
CAUTION: EQUIPMENT DAMAGE
Failure to maintain the engine oil at the proper level DIESEL FUEL
will result in serious engine damage.
Always use a good grade of # 2 diesel fuel. For cold
weather, blended #1 fuel may be used. Fuel cetane number
Before starting the engine, verify the crankcase is filled to should be 45 or higher and the fuel MUST be low sulfur
the proper level with a good quality oil. The recommended or ultra low sulfur fuel. See engine operators manual for
grade oil and quantity of oil required is listed in the engine additional fuel recommendations including Bio-Diesel fuel.
operator’s manual and under the service tab in this manual. Never use gasoline or gasohol. Always ensure that the fuel
This unit was shipped with oil in it. The engine normally is clean and free of all impurities. Always be sure to keep the
holds 1.3 quarts (41.6 oz.) of oil. Use the dipstick to ensure strainer in place when filling the fuel tank.
that you have the proper oil level in the crankcase. The full
oil level mark on the dipstick is depicted in the following WARNING: FIRE DANGER
image.
Diesel fuel is flammable and can be ignited, causing or
enlarging fires when proper precautions are not taken.
Never use fuel that has been stored for an extended period
of time. Fuel will lose its volatile properties and you will
be left with a ‘gum’ or varnish residue. This varnish-like
substance will clog the filters, fuel lines, and injectors. Old,
contaminated, stale fuel will not burn properly. The use of a
fuel additive, such as Sta-Bil, or an equivalent will minimize
the formation of fuel gum deposits. If a unit has been out of
operation for an extended period of time, it is best to drain
old fuel from the engine and replace with fresh fuel before
attempting to start.
Oil is added to the engine by removing the oil cap and
adding oil at this point. After filling the crankcase to the
proper level, be sure you properly tighten the oil fill cap.
NOTE: This engine generator must be on a level surface
before you check or add oil to the system.
This engine generator set is shipped with a battery tie down Do NOT open or mutilate the battery. Released
for customer installation. electrolyte is known to be harmful to the skin and eyes
and to be very toxic.
Never fill the battery above the fill line. Overfilling above
the upper level line may cause the electrolyte to overflow,
resulting in corrosion to the engine or nearby parts.
Immediately wash off any spilled electrolyte following the
procedure above.
OPM-133/E 8
Note: always make sure that a new battery is fully charged
before installing it on a generator set.
BATTERY CHARGING
Units have a small flywheel charger built into the engine
flywheel assembly for recharging the starting battery. This
flywheel charger generates a small AC current that passes
through a diode assembly to produce DC charging current
of about 1 to 3 Amps. This circuit is not designed to be used
as a battery charging circuit to recharge dead batteries.
In the bag of parts for the lifting eye, ensure all of the
required materials are included: 2 qty - 5/16-18 x 2.25
button head socket screws (#1); 2 qty - washers (#2); 2 qty -
.3125-18 flange (#3); 1 qty - lifting eye (#4).
1. Place the bottom of the lifting eye (#4) under the cross
bar (#5).
9 OPM-133/E
INITIAL START UP
The throttle control on these generators is preset and 5. Return key to 1st position when engine is running (Ref A).
locked to operate at 3600 RPM (nominal) with no load
speed set at 3690 RPM. Only a trained service technician A
should be allowed to adjust this speed setting.
STARTING HINTS
BASIC OPERATION
1. COLD WEATHER
If the engine is cold and stiff or if the battery is not fully Use the proper oil for the temperature expected.
charged, starting can be made easier by slowly hand
cranking the engine through the compression stroke before CAUTION: EQUIPMENT DAMAGE
pushing the starter switch. This permits the starter to gain
Never use ether or any other starting aides. Serious
momentum before the heavy load of the compression
stroke occurs. This minimizes the drain on the battery and engine damage or personal injury may result from
improves the possibility of starting under such adverse ignoring this simple warning.
conditions. Always keep the battery charged, especially
during cold weather operation. 2. HOT WEATHER
Use the proper oil for the temperature expected.
1. Check oil level, refill as needed.
2. Make sure the fuel solenoid valve lever is in the down STOPPING
position. This lever should never be put in the up position.
The lever is located under the key switch as pictured. 1. Move the key to the “OFF” position.
A. While the engine is warm, drain the oil and refill with
fresh oil.
B. Clean dirt and chaff from cylinder, cylinder head fins,
blower housing, screen, and muffler areas.
C. Store in a clean and dry area.
OPM-133/E 10
CONNECTING THE LOADS
The engine-generator covered in this manual was designed Proper utilization of the receptacles located on the control
for portable use. Do NOT operate indoors. The unit should panel is necessary to prevent damage to either the
be stored in a warm, dry location. Move the unit outdoors receptacles or the generator. The generator is a limited
to a flat, dry location for use. source of electrical power, therefore, pay special attention
to the receptacle and generator ratings. The nameplate
WARNING: PERSONAL DANGER: rating can be obtained through a single receptacle as long
as the receptacles amperage rating is not exceeded.
Operating any engine driven generator without
proper air flow can result in personal injury or death.
DO NOT operate this unit inside a home or garage, GROUNDING
near vents or windows, or anywhere carbon monoxide
gas could accumulate. Proper grounding of your generator is application
dependent. Carefully evaluate your planned use of your
generator to understand which grounding you require.
If you are not sure what to do, contact a competent
professional to assist you. The NFPA 70 250:34-35 are good
technical references.
VEHICLE-MOUNTED GENERATOR
APPLYING THE LOADS
Your WINCO portable generator ships with a bonded
Allow the engine to warm up for two or three minutes neutral. When mounted to a vehicle to safely distribute
before applying any load. This will allow the engine to power it is necessary that the generator frame is bonded
reach normal operating temperature and oil to circulate to the vehicle frame. The generator should only supply
throughout the engine. A short warm-up time will permit equipment that is cord and plug connected through
the engine to work more efficiently when the load is receptacles mounted on the generator or the vehicle.
applied and will reduce the wear in the engine, extending
its life. Receptacles have been provided to allow loads to be PERMANENTLY INSTALLED GENERATORS
connected to the generator.
This WINCO portable generator ships with a bonded
The loads should be added one at a time. If a large motor neutral and overcurrent protection. NFPA 70 refers to this
is being started: or multiple motors are being started, they as a “separately derived system.” When connecting it to a
should be started individually and the largest should be building a transfer switch specifically designed for GFCI and
started first. bonded neutral generators is required.
OPM-133/E 12
YOURGEN
The WINCO YourGen meter allows you to see useful The speed of the engine was carefully adjusted at the
information about your generator from the front panel factory so that the generator produces the proper voltage
by displaying RPMs, Voltage, frequency, load, hours, and and frequency. For normal usage, the speed setting should
maintenance reminders. It also has the ability to display not be changed. If the generator is being run continuously
warnings if any parameter gets outside of normal operation on a very light load, it is often advisable to lower the
range. operating speed slightly.
OPERATING SPEED V2 -
All engines have a tendency to slow down when a load Output voltage of Line 2 (L2 on panel) to neutral. See the
is applied. When the electrical load is connected to the Load vs. Output table for an explanation of voltage and
generator, the engine is more heavily loaded, and as a frequency ranges under load.
result, the speed drops slightly. This slight decrease in
speed, together with the voltage drop within the generator V1-V2 -
itself, results in a slightly lower voltage when the generator Output voltage of Line 1 (L1) and Line 2 (L2). See the
is loaded to its full capacity than when running no load. Load vs. Output table for an explanation of voltage and
The slight variation in speed also affects the frequency frequency ranges under load.
of the output current. This frequency variation has no
appreciable effect in the operation of motors, lights, and Hours -
most appliances. However, electronic equipment and clocks This displays the total running hours of the generator set.
will be affected if correct RPM is not maintained. See Load When the generator is turned off, the hours will remain
vs. Output chart. displayed. The display is run on a CR2032, ten-year battery.
Once the unit is running, the battery connected to the unit
will then supply the power to the YourGen meter.
Although individual units and models vary slightly, the
normal voltage and frequency of the engine-generator
Load Bars -
described in this manual are approximately as follows,
These bars indicate how much load is being used on Line 1
under varying loads:
(L1) and Line 2 (L2).
LOAD vs. OUTPUT
= 1-25% = 25-50% = 50-75% = 75-100%
Voltage
Generator Speed Frequency
Load (RPM) (Hz) 120V 240V
Recpt Recpt
None 3690 61.5 125V 258V
Half 3600 60.0 120V 240V
Full 3510 58.5 115V 230V
13 OPM-133/E
It is good practice to monitor the YourGen Meter when The battery has a 10 year lifetime, in the event you need to
applying load. This will ensure the generator is balanced. change the battery, follow these instructions:
Alarms -
The display will start blinking and toggle to the first
parameter that is out of specification. The panel will remain
flashing until the fault condition returns to within the
acceptable range, see following table.
Acceptable Range
Frequency 57-63 Hz
Voltage 110VAC-130VAC
VAC1-VAC2 220VAC-260VAC
Battery -
When the unit is off, the YourGen meter will display the
hours continuously using a coin cell back-up battery inside
the meter. Once the unit is running, the meter will get
power from the main unit battery.
Voltage 3.0V DC
Battery Type CR2032
Lifetime 10 Years
OPM-133/E 14
ENGINE CARE
MAINTENANCE SCHEDULE C. Replace oil drain plug.
D. Remove oil fill cap.
Daily or Every Every
Every 10 250* hrs 500** hrs
hrs
Check Oil ü
Check oil filter ü
Check dry air cleaner ü
Fuel tank cleaning ü
Clean cooling fins ü
Replace engine oil ü
E. Fill to correct level with oil. Reinstall cap.
Replace oil filter ü F. Remove the oil filter and dispose of it properly.
Replace fuel filter ü
Set and clean ü
injectors
Rocker arm ü
adjustment
* If engine use is infrequent; every year
** If engine use is infrequent; every 2 years
NOTE: This engine requires 41.6 oz. (1.3 qts) of oil if it is
If you are using oil of a quality lower than the completely drained. Use caution when refilling the engine
recommended one then you will have to replace it every as some residual oil may have remained in the engine.
150 hours Always use the dipstick when filling the engine with oil to
prevent overfilling.
If major engine service or repair is required, contact an
authorized engine service center. The manufacturer of H. Replace oil filter and filter plug.
these engines has established an excellent world-wide I. Start the engine and warm it up.
engine service organization. Engine service is very likely J . After warming up the engine, recheck the oil level and
available from a nearby authorized dealer or distributor. refill as necessary to bring it to the proper level.
Drain Bolt
15 OPM-133/E
B. Remove the wing nut.
OPM-133/E 16
GENERATOR CARE
Proper care and maintenance of the generator is necessary
to ensure a long trouble free life.
GENERATOR MAINTENANCE
Any major generator service, including the installation
or replacement of parts, should be performed only by
a qualified electrical service technician. USE ONLY
FACTORY APPROVED REPAIR PARTS.
CLEANING
Remove dirt and debris with a cloth or brush. DO NOT
use high pressure spray to clean either the engine or the
generator. The high pressure spray could contaminate the
fuel system and the generator components.
17 OPM-133/E
TROUBLESHOOTING
Problem Possible Causes
Won’t start Low oil level
Out of fuel
Start switch in OFF position
Fuel Valve turned off
Plugged fuel filter
Blown fuse in key switch
Battery required to open solenoid
Voltage too low Engine speed is too low
Generator overloaded
Defective stator
Defective rotor (field)
Defective capacitor
Circuit breaker trips Defective load
Defective receptacle
Excessive load
GFCI type of load i.e. a building with
bonded neutral
Voltage too high Engine speed is too high
Generator overheating Overloaded
Insufficient ventilation
No output voltage Short in load (disconnect)
Tripped or defective circuit breaker
Broken or loose wire
Defective receptacle
No residual magnetism (in
generator)
Defective stator
Defective rotor (field)
Shorted capacitor
Shorted diodes on rotor
GFCI receptacle tripped
Will not shutdown Fuel solenoid valve lever is in up
position
OPM-133/E 18
G1
GND
G2 N
G1 GND
N
G1 G1 N
19
G2
G1 N
GND
WIRING DIAGRAM
G1
N
N
G2
G2
G2
G1
GND GND
OPM-133/E
ENGINE GENERATOR SET
36 MONTH
LIMITED WARRANTY
WINCO warrants to the original purchaser for 36 months or 1000 hours, whichever occurs first, that goods manufactured
or supplied by it will be free from defects in workmanship and material, provided such goods are installed, operated and
maintained in accordance with WINCO written instructions and applicable codes.
WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the
product. At WINCO’s option, material found to be defective in material or workmanship under normal use and service
will be repaired or replaced. For warranty service, return the product within the warranty period, to your nearest WINCO
Authorized Service Center or to WINCO in Le Center Minnesota.
EXCLUSIONS:
THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN. THERE ARE NO OTHER
WARRANTIES, EXPRESSED OR IMPLIED, OR OTHERWISE CREATED, INCLUDING BUT NOT LIMITED TO WARRANTIES OF
MERCHANTABILITY, OR WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE.
WINCO is liable for the repair or replacement of the product only and is not liable for incidental or consequential damages
as permitted by your state. This warranty gives you specific legal rights which may vary from state to state.
Your evaporative emission control system may include parts such as: carburetor, fuel tank, fuel cap, fuel lines (for liquid fuel
and fuel vapors), fuel line fittings, fuel line clamps, carbon canisters, and carbon canister mounting brackets.