Professional Documents
Culture Documents
AMS 2140 Overview
AMS 2140 Overview
AMS 2140 Overview
4-chRoute Yes No
4-ch Simultaneous Display Yes No
4-chTransient Yes No
4ch ODS/Modal Yes No
4-ch Volts/Displacement Yes No
Weight ~10% Lighter (3.95lbs) 4.5lbs
Thickness 20% Thinner (1.5”) 1.88”
Volume 23% Less (119”) 154”
Diagonal Screen Size 6% Larger (7.5”) 7.1”
Touch screen Yes No
Screen brightness 13x Brighter 13x Dimmer
Battery life 2x longer (10+ hrs) 5 hrs
Li-ION battery Yes No
Wi-Fi Yes No
Bluetooth wireless Headphones Yes No (wired)
Backlit Keypad Yes No
Data Collection Speed ~30% Faster ~30% Slower
Triax collection Simultaneous Muxed
Auto light sensor Yes No
Built-in Stand Yes No
External Battery Charger Yes No
Cinco entradas = Cuatro Canales + Tacho
Five Inputs:
Channel 1
Channel 2
Channel 3
Channel 4
+
Tachometer
Cuatro Canales de Voltage + Tach
Dual Orbits!
Cuatro Canales de Voltage + Tach
Time in minutes 60 39 31
Extrapolar a un medio día de trabajo (4 horas)
Number of Machines
in 4 Hours 156 240 302
39 machines 2130/1 2140/1 2140/3
Time in minutes 60 39 31
Ethernet Bluetooth to
USB 2.0 Wi-Fi to AMS
Load Ethernet Manager
Machinery accessories
Routes Secure
Communications
via USB Digital (SD)
Port
Memory Wi-Fi Memory
Stick Card Slot
Bateria Litio
8 Hr
24 Hr
External Charger
Thin Profile
5
6 1 mm
3 0
4 2
3
4
5
6
7
8
9
Soporte Incorporado
Memoria
1 GB
Internal
External
Familiar, Interfaz Facil
Ruta via Email
@
Herramientas de Analisis de Campo
Parameter Trend
Alarms
Fault Frequencies
PeakVue™ es Facil
Only offered by Emerson
– Common to all CSI brand vibration products
– 10+ patents… and counting
Zero Principle: Close to zero G’s Interpretation
on a good machine
Rule of 10’s 0 Good machine
– Typical alert levels at 10 Some Issue
• 10 – something’s happening
20 Serious problem
• 20 – something serious happening
• 40 – time to take action 40 Action Point
Car Charger
Mining
“The 4-ch input adapter is great.
We will use the 4-channels for
impact testing and transient
measurements”
Power Generation
“The CSI 2140 is noticeably faster.
The 4-channels will make the ODS
measurements easier and faster”
Pruebas de Campo
Chemical
“bright screen, 4-channel capability,
small size and a lot more portable…
This is the most comfortable strap I
have used in the last 15 years.”
Refining
“The CSI 2140 data collection speed is
definitely a high selling point!!!!! Lighter weight
is also a big improvement. New color screen
display is excellent.
Even in direct sun light I had no issues with
clearly seeing and or navigating through the
vibration data on the field.”
Customer Testing
Pulp & Paper
“The touchscreen makes it easy to navigate. The screens are much faster.
I am going to use the Triaxial accelerometer to keep me from having to climb on
the machine to get to the measurement points
El Nuevo CSI 2140
Donde utilizar Triax o 4 canales?
Everywhere in Route Mode
– Faster
– Easier
Paper Plants (dryer section)
Turbines Start-up (need to see phase info at both
planes, so 4 Channels+Phase)
All Advanced Applications Where Cross Channel Data is
Needed
Resonancia
Natural frequencies are directional
So, you need to measure in Horizontal, Vertical and
Axial direction.
With CSI 2140, all directions can be measured
simultaneously
For hammer impact tests, your hammer is channel 4
Modo Orbitas
True Orbit Plot
– Measure displacement
– Twice two prox probes
at 90E
Casing Vibration
– Twice two accel
sensors at 90E
– Double integrate
Fase Canales Cruzados
Check for Misalignment
– Measure across a coupling
– Check phase at running speed
Structural Analysis Options
Operating Deflection Shape
– Performed while machine in operation
– Single frequency measurement
– Can be performed with any CSI machinery analyzer
– But four channel or more is recommended
– Measures actual amplitude of deflection
– Shows how machine deflects in normal operation
Modal Analysis
– Requires machine to be shut down
– Analysis across all frequencies
– Requires dual of four channel 2140 for measurements
– The 4 channels option. 1 channel is reference + triax
– Determines ratio of response to input, no absolute
amplitudes
– Detailed model of machine stiffness, resonances, etc.
ODS: Algunos Ejemplos