AMS 2140 Overview

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 38

CSI 2140 FEATURE CSI 2140 CSI 2130

vs. 2130 Simultaneous Channels + Phase 4 2

4-chRoute Yes No
4-ch Simultaneous Display Yes No
4-chTransient Yes No
4ch ODS/Modal Yes No
4-ch Volts/Displacement Yes No
Weight ~10% Lighter (3.95lbs) 4.5lbs
Thickness 20% Thinner (1.5”) 1.88”
Volume 23% Less (119”) 154”
Diagonal Screen Size 6% Larger (7.5”) 7.1”
Touch screen Yes No
Screen brightness 13x Brighter 13x Dimmer
Battery life 2x longer (10+ hrs) 5 hrs
Li-ION battery Yes No
Wi-Fi Yes No
Bluetooth wireless Headphones Yes No (wired)
Backlit Keypad Yes No
Data Collection Speed ~30% Faster ~30% Slower
Triax collection Simultaneous Muxed
Auto light sensor Yes No
Built-in Stand Yes No
External Battery Charger Yes No
Cinco entradas = Cuatro Canales + Tacho

Five Inputs:
 Channel 1
 Channel 2
 Channel 3
 Channel 4
+
 Tachometer
Cuatro Canales de Voltage + Tach

Dual Orbits!
Cuatro Canales de Voltage + Tach

4 Channel Accel+ Tach


Multiples Pantallas en Vivo
Patentado Emerson Triax = Fácil y Rápido!

 4x faster than CSI 2120


 2x faster than CSI 2130
Modo Visualización en Vivo
 39 Machines in the Field, Same Location
 Some Had Two Bearings
(only motor)
 Some Had Four Bearings
(motor-fan)
 Same Analyzer Configuration
 Same Database

39 machines 2130 2140 2140/3

Time in minutes 60 39 31
Extrapolar a un medio día de trabajo (4 horas)

2130 2140 2140/Triax

Number of Machines
in 4 Hours 156 240 302
39 machines 2130/1 2140/1 2140/3
Time in minutes 60 39 31

Machines in 4 hours 156 240 302


Machines in 1 month (17.5 days) 2730 4200 5284
Machines in 1 year (12 months) 32760 50400 63406
Or another way is to think of it is 156
machines takes 2 hours and 5 minutes with a
2140/triax versus 4 hours with a 2130/1
Display de Gran Tamaño
Iluminación Automatica
Teclado Retroalimentado
Pantalla Tactil

Even with a glove!


Modos de Comunicación

Ethernet Bluetooth to
USB 2.0 Wi-Fi to AMS
Load Ethernet Manager
Machinery accessories
Routes Secure
Communications
via USB Digital (SD)
Port
Memory Wi-Fi Memory
Stick Card Slot
Bateria Litio

8 Hr
24 Hr

External Charger
Thin Profile

5
6 1 mm
3 0
4 2
3
4
5
6
7
8
9
Soporte Incorporado
Memoria

1 GB

Internal
External
Familiar, Interfaz Facil
Ruta via Email

@
Herramientas de Analisis de Campo

Parameter Trend
Alarms

Fault Frequencies
PeakVue™ es Facil
 Only offered by Emerson
– Common to all CSI brand vibration products
– 10+ patents… and counting
 Zero Principle: Close to zero G’s Interpretation
on a good machine
 Rule of 10’s 0 Good machine
– Typical alert levels at 10 Some Issue
• 10 – something’s happening
20 Serious problem
• 20 – something serious happening
• 40 – time to take action 40 Action Point

 Much earlier warning than normal vibration –


or the competition!
PeakVue™ Es Universal
 Addresses key customer problem issues
– rolling element bearings, gear boxes, lubrication, and cavitation
 Simple to interpret
– “Rule of 10’s” applies to 95%+ of all plant equipment
 Earlier warning, more universal than any other method
– more time to plan = less surprises, less expense

Machine Health analogy:


Not possible to run detailed tests on everyone. Doctor
needs a way to screen patients who have potential
problems. Needs to be simple and conclusive, so that
a nurse or med tech can administer it and interpret it.
New Accessories
 CSI 2140 4-Channel Input
Adapter (Accel & Volts)

 Splitter Cables for 4-Channel

 Car Charger

 Bluetooth Wireless Headphones

 External Battery Charger


Pruebas de Campo

Mining
“The 4-ch input adapter is great.
We will use the 4-channels for
impact testing and transient
measurements”

Power Generation
“The CSI 2140 is noticeably faster.
The 4-channels will make the ODS
measurements easier and faster”
Pruebas de Campo
Chemical
“bright screen, 4-channel capability,
small size and a lot more portable…
This is the most comfortable strap I
have used in the last 15 years.”

Refining
“The CSI 2140 data collection speed is
definitely a high selling point!!!!! Lighter weight
is also a big improvement. New color screen
display is excellent.
Even in direct sun light I had no issues with
clearly seeing and or navigating through the
vibration data on the field.”
Customer Testing
Pulp & Paper
“The touchscreen makes it easy to navigate. The screens are much faster.
I am going to use the Triaxial accelerometer to keep me from having to climb on
the machine to get to the measurement points
El Nuevo CSI 2140
Donde utilizar Triax o 4 canales?
 Everywhere in Route Mode
– Faster
– Easier
 Paper Plants (dryer section)
 Turbines Start-up (need to see phase info at both
planes, so 4 Channels+Phase)
 All Advanced Applications Where Cross Channel Data is
Needed
Resonancia
 Natural frequencies are directional
 So, you need to measure in Horizontal, Vertical and
Axial direction.
 With CSI 2140, all directions can be measured
simultaneously
 For hammer impact tests, your hammer is channel 4
Modo Orbitas
 True Orbit Plot
– Measure displacement
– Twice two prox probes
at 90E

 Casing Vibration
– Twice two accel
sensors at 90E
– Double integrate
Fase Canales Cruzados
 Check for Misalignment
– Measure across a coupling
– Check phase at running speed
Structural Analysis Options
 Operating Deflection Shape
– Performed while machine in operation
– Single frequency measurement
– Can be performed with any CSI machinery analyzer
– But four channel or more is recommended
– Measures actual amplitude of deflection
– Shows how machine deflects in normal operation
 Modal Analysis
– Requires machine to be shut down
– Analysis across all frequencies
– Requires dual of four channel 2140 for measurements
– The 4 channels option. 1 channel is reference + triax
– Determines ratio of response to input, no absolute
amplitudes
– Detailed model of machine stiffness, resonances, etc.
ODS: Algunos Ejemplos

Click on the images to start the movies.


ODS on Cañerias
 Triax sensor + ODS
offers more
locations to collect
data
 In the past, this was
compensated in the
software with data
interpolation
 But triax
measurements
solve this
Aplicación del Test de Impacto
 Structural Analysis
– Identify resonances
– Measure stiffness
– Determine system response
– Modal analysis
 Use One Hammer and Three Accelerometers
 Use One Hammer and One Triax Sensor

You might also like