Professional Documents
Culture Documents
Feed Pump (96516667 - CR - 327 - AFGJAEHQQE)
Feed Pump (96516667 - CR - 327 - AFGJAEHQQE)
Created by:
Phone:
Date: 23/06/2024
H CR 3-27, 3*380 V, 50Hz eta
Description Value [m] [%]
General information:
Product name: CR 3-27 180 90
A-FGJ-A-E-HQQE
160 80
Product No: 96516667
EAN number: 5700396747576 140 70
Technical: 120 60
Pump speed on which pump data are 2899 rpm
based: 100 50
Impellers: 27 20 10
Number of reduced-diameter impellers: 0
0 0
Low NPSH: N 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [m³/h]
Pump orientation: Vertical Q = 3.038 m³/h H = 134.4 m
Pumped liquid = Water Density = 998.2 kg/m³
Shaft seal arrangement: Single
Eta pump = 57.7 % Eta pump+motor = 50.5 %
Code for shaft seal: HQQE Liquid temperature during operation = 20 °C
Approvals: CE,EAC,UKCA,SEPRO P NPSH
[kW] [m]
Approvals for drinking water: WRAS,ACS P1
Curve tolerance: ISO9906:2012 3B 2.0 8
P2
Pump version: A
1.5 6
Model: A
Materials: 1.0 4
Base: Cast iron 0.5 2
Base: EN 1561 EN-GJL-200
0.0 0
Base: ASTM A48-25B
P1 = 2.2 kW
Impeller: Stainless steel P2 = 1.923 kW
Impeller: EN 1.4301 NPSH = 1.46 m
100
20
75
89
35
100
1
4
x 3.5 141
733
1 X G 1/2
24.5
4
1
x 9
G 1/2 135
321
110
178
Bearing: SIC
Installation:
321
1 X G 1/2
Type of connection: DIN / ANSI / JIS
Size of inlet connection: DN 25/32
100
140
20
100 35
Pressure rating for connection: PN 25 141 89
4 x 13.5
250 180
Flange rating inlet: 250 lb 220
Date: 23/06/2024
Description Value
Rated current: 8.00/4.60 A
Starting current: 840-920 %
Cos phi - power factor: 0.86-0.80
Rated speed: 2890-2910 rpm
IE Efficiency class: IE3
Motor efficiency at full load: 85.9 %
Motor efficiency at 3/4 load: 88.2-87.2 %
Motor efficiency at 1/2 load: 88.0-85.5 %
Number of poles: 2
Enclosure class (IEC 34-5): 55 Dust/Jetting
Insulation class (IEC 85): F
Built-in motor protection: NONE
Motor No: 85U01908
Controls:
Frequency converter: None
Others:
Terminal box position: 6
Minimum efficiency index, MEI ≥: 0.70
Net weight: 47.7 kg
Gross weight: 50.6 kg
Shipping volume: 0.13 m³
Danish VVS No.: 385901027
Swedish RSK No.: 5824840
Norwegian NRF no.: 9040234
Date: 23/06/2024
cos phi
eta
0.8 8
I
0.6 6
0.4 4
0.2 2
0.0 0
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 P2 [kW]
n P1
[rpm] [kW]
3000
2800 4.0
P1
2600 3.0
2400 2.0
2200 1.0
2000 0.0
Date: 23/06/2024
13.5
x
140
4
100
180
220
35
89
24.5
x
20
19
4x
G 1/2
100
178
141
250
110
1 X G 1/2
G 1/2
135
75
321 733
Date: 23/06/2024
LOW VOLTAGE
DIRECTION OF ROTATION
L1 L2 L3
HIGH VOLTAGE
DIRECTION OF ROTATION
L1 L2 L3
Date: 23/06/2024
1 2 3 4 5 H eta
CR 3-27, 3*380 V, 50Hz
[m] [%]
Flow (%) 18 46 66 83 101
Q = 3.038 m³/h
100
Flow (m³/h) 0.53 1.38 1.98 2.48 3.04 H = 134.4 m
Pumped liquid = Water
Head (%) 135 128 122 114 103 Liquid temperature during operation = 20 °C
180 90
Head (m) 176.5 167.9 159.5 149.4 134.4 Density = 998.2 kg/m³
100 50
80 40
60 30
40 20
20 10
Eta pump = 57.7 %
Eta pump+motor = 50.5 %
0 0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [m³/h]
P NPSH
[kW] [m]
P1
2 10
P2
1 5
P1 = 2.2 kW
P2 = 1.923 kW
NPSH = 1.46 m
0 0