FusionServer 2288H V6-32DIMM Server Quick Start Guide

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

13 USB 3.

0 ports 14 VGA port


2288H V6 Server Quick Start Guide 2 Front and Rear Panels 15 Serial port 16 Connection status indicator for the
management network port
Document Issue: 05 (2023-11-27) BOM: 31500GSR (2/3) 17 Management network port 18 Data transmission status indicator for the
management network port
19 (Optional) FlexIO card 1 - -
xFusion Digital Technologies Co., Ltd. NOTE
The FlexIO card slot supports OCP
3.0 network adapters.
Copyright © xFusion Digital Technologies Co., Ltd. 2023. All Rights Reserved.
No part of this document may be reproduced or transferred in any form or by any means without prior written consent of xFusion Digital
Technologies Co., Ltd.

and other xFusion trademarks are trademarks of xFusion Digital Technologies Co., Ltd.
All other trademarks or trade names mentioned in this document are the property of their respective holders. 3 Indicators and Buttons
In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding, which
does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as any Indicators and buttons on the front panel
meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technologies Co., Ltd. shall not bear any liability resulting
from the use of "xFusion". No. Indicator/Button Description Remarks
All other trademarks or trade names mentioned in this document are the property of their respective holders.
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to 1 Fault diagnosis ⚫
For details about
---: The device is operating properly.
ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any
kind, either express or implied.
LED error codes, see
xFusion places export control obligations above its commercial interests and refuses to sell or export tangible or intangible products, ⚫ Error code: A component is faulty. FusionServer
technologies, and services for end-users or end-uses prohibited by relevant export control laws and regulations. Rack Server
iBMC Alarm
1 Introduction Handling.
2 Power Power indicator: None
FusionServer 2288H V6 (2288H V6) is a new-generation 2U 2-socket rack server designed for button/indicator
Internet, Internet Data Center (IDC), cloud computing, enterprise, and telecom service applications. ⚫ Off: The device is not powered on.
The 2288H V6 is ideal for IT core services, cloud computing, virtualization, high-performance ⚫ Steady green: The device is powered on.
computing, distributed storage, big data processing, enterprise or telecom service applications, and
other complex workloads. ⚫ Blinking yellow: The iBMC is starting. The
The following table lists the 2288H V6 technical specifications. For details, see FusionServer 2288H power button is locked and cannot be
V6 Server User Guide.
pressed. The iBMC is started in about 1
Item Specification
minute, and then the power indicator is
steady yellow.
Dimensions (H x W x D) 86.1 mm x 447 mm x 790 mm (3.39 in. x 17.60 in. x 31.10 in.) ⚫ Steady yellow: The device is standby.
Power button:
⚫ Operating temperature: 5°C to 45°C (41°F to 113°F) (ASHRAE ⚫ When the device is powered on, you can
Classes A1 to A4 compliant) press this button to gracefully shut down
⚫ Storage temperature (within three months): –30°C to +60°C (– the OS.
22°F to +140°F) NOTE
⚫ Storage temperature (within six months): –15°C to +45°C (5°F to For different OSs, you may need to shut
Temperature
113°F) down the OS as prompted.
⚫ Storage temperature (within one year): –10°C to +35°C (14°F to ⚫ When the device is powered on, you can
95°F) hold down this button for 6 seconds to
⚫ Maximum rate of temperature change: 20°C (36°F) per hour, 5°C forcibly power off the device.
(9°F) per 15 minutes ⚫ When the power indicator is steady yellow,
⚫ 1 Fault diagnosis LED 2 Power button/indicator you can press this button to power on the
Operating humidity: 8% to 90%

3 Health status indicator 4 UID button/indicator device.
Storage humidity (within three months): 8% to 85%
Relative humidity (RH, 5 Presence indicator for FlexIO card 1 6 Presence indicator for FlexIO card 2 3 Health status For details about
⚫ ⚫ Off: The device is powered off or is faulty.
non-condensing) Storage humidity (within six months): 8% to 80% 7 Drives 8 (Optional) Built-in DVD drive (or LCD indicator how to handle
⚫ module) ⚫ Blinking red at 1 Hz: A major alarm has alarms, see
Storage humidity (within one year): 20% to 75%
9 iBMC direct connect management 10 USB 3.0 ports been generated on the system. FusionServer
⚫ Maximum humidity change rate: 20%/h port indicator Rack Server
11 iBMC direct connect management 12 VGA port ⚫ Blinking red at 5 Hz: A critical alarm has iBMC Alarm
⚫ Operating altitude ≤ 3050 m (10006.44 ft) port been generated on the system. Handling.
 When the server configuration complies with ASHRAE 13 Slide-out label plate (with an SN - -
⚫ Steady green: The device is operating
Classes A1 and A2 and the altitude is above 900 m label)
(2952.76 ft), the highest operating temperature decreases properly.
by 1°C (1.8°F) for every increase of 300 m (984.24 ft). 4 UID The UID button/indicator helps identify and None
 When the server configuration complies with ASHRAE
button/indicator locate a device.
Class A3 and the altitude is above 900 m (2952.76 ft), the UID indicator:
Altitude
highest operating temperature decreases by 1°C (1.8°F)
for every increase of 175 m (574.14 ft). ⚫ Off: The device is not being located.
 When the server configuration complies with ASHRAE
⚫ Blinking or steady blue: The device is
Class A4 and the altitude is above 900 m (2952.76 ft), the
highest operating temperature decreases by 1°C (1.8°F) being located.
for every increase of 125 m (410.10 ft). UID button:
⚫ HDDs cannot be used at an altitude of over 3050 m (10006.44 ft). ⚫ You can control the UID indicator status by
pressing the UID button or using the
iBMC.
1 I/O module 1 2 Serial port indicator (reserved)
3 I/O module 2 4 I/O module 3 ⚫ You can press this button to turn on or off
5 Socket for PSU 2 6 Indicator for PSU 2 the UID indicator.
7 PSU 2 8 Socket for PSU 1
⚫ You can press and hold down this button
9 Indicator for PSU 1 10 PSU 1
11 (Optional) FlexIO card 2 12 UID indicator for 4 to 6 seconds to reset the iBMC.
NOTE 5/6 FlexIO card None
The FlexIO card slot supports OCP Indicates whether the FlexIO card is
presence
3.0 network adapters. indicator detected.
No. Indicator/Button Description Remarks No. Indicator Description Remarks Log in to the iBMC CLI, run the ipmcset -d powerstate -v 1 command, and enter y or Y.
 Power on the server using the Remote Virtual Console.
⚫ Off: The FlexIO card is not detected. network port connected properly. Log in to the Remote Virtual Console. On the KVM screen, click or on the
⚫ Blinking green at 0.5 Hz: The FlexIO card 18 Data ⚫
None toolbar, select Power On, and click OK.
Off: No data is being transmitted.
transmission
is detected but is not powered on.
status indicator ⚫ Blinking yellow: Data is being transmitted.
⚫ Blinking green at 2 Hz: The FlexIO card is for the 6 Error Codes
detected and has just been inserted. management
network port Error Code Fault Description Remarks
⚫ Steady green: The FlexIO card is detected -
--- The server is operating normally.
and the power supply is normal.
C0X CPU X is abnormal or faulty. X indicates the CPU number.
9 iBMC direct Indicates the status when the iBMC direct None 4 Installation XXX indicates the DIMM
connect connect management port connects to a XXX DIMM XXX is abnormal or faulty.
management terminal (local PC or Android mobile phone): number.
port indicator The air inlet temperature is out of the -
⚫ A00
Off: No terminal is connected. operating temperature range of the server.
⚫ Blinking green at short intervals for 3
• Before unpacking and installing the server, wear an ESD wrist strap or gloves to avoid The temperature of CPU X exceeds its X indicates the CPU number.
damage to electrostatic-sensitive parts. A0X
normal range.
seconds and then off: The port is disabled.
• At least two people are required to place the server horizontally on the guide rails and P0X PSU X is abnormal or faulty. X indicates the PSU number.
⚫ Steady green: The terminal is connected. push it into the cabinet.
X indicates the fan module
Indicates the status when the iBMC direct F0X Fan module X is abnormal or faulty.
1. Install the server. number.
connect management port connects to a b01 The power supply to the mainboard is -
USB device: (1) Place the server on the guide rails and push it into the cabinet.
abnormal.
(2) Align the mounting ears on both sides of the server with the mounting bars of the
⚫ Blinking red at long intervals: The job fails cabinet, and tighten the captive screws on the mounting ears to secure the server. b02 The RAID controller card is abnormal or -
faulty.
or an error is reported when the job is
L01 The cable is not securely or correctly -
complete. connected.
⚫ Blinking green at short intervals: The job is E01 The CMOS battery is abnormal. -
being executed. HXX The drive in slot XX is abnormal or faulty. XX indicates the drive
⚫ number.
Blinking green at short intervals for 3
In this table, X is an integer.
seconds and then off: The port is disabled.
⚫ Steady green: The server configuration file
is being copied from the USB device or the 7 Follow-up
job is successfully completed. After a server is powered on, configure the server. For details, see FusionServer 2288H V6
Server User Guide.
Indicators on the rear panel Obtain the document from https://www.xfusion.com.
No. Indicator Description Remarks
6/9 PSU indicator ⚫
Replace the PSU
Off: No power is supplied.
if the indicator is
⚫ Blinking green at 1 Hz: in any of the
 The input is normal, and the server following states:
is standby. ⚫ Blinking green 2. Connect cables to service and management network ports.
 The input is overvoltage or
at 1 Hz after
undervoltage.
 The PSU is in deep hibernation the server is
mode. powered on
⚫ Blinking green at 4 Hz: The firmware is ⚫ Steady orange
being upgraded online.
3. Connect the power cables.
⚫ Steady green: The power input and output
are normal.
⚫ Steady orange: The input is normal but
there is no output.
NOTE
The possible causes of no power output are
as follows:
⚫ Power supply overtemperature protection
⚫ Power output overcurrent or short-circuit
⚫ Output overvoltage
⚫ Short-circuit protection
⚫ Device failure (excluding failure of all
devices)
12 UID indicator The UID indicator helps identify and locate a None
device.
⚫ Off: The device is not being located. 5 Power-On
⚫ Blinking or steady blue: The device is being Power on the server using any of the following methods:
⚫ If the PSUs are properly installed but not powered on, connect the power module to the
located. external power supply. The server is powered on along with the PSUs.
NOTE ⚫ If the PSUs are properly installed and connected to the external power supply, and the server is
You can control the UID indicator status by in standby status (the power indicator is steady yellow),
pressing the UID button or using the iBMC.  Press the power button on the front panel to power on the server.
16 Connection ⚫
None  Power on the server using the iBMC WebUI.
Off: The network port is not connected.
status indicator Log in to the iBMC WebUI, choose System > Power > Power Control, click Power
for the ⚫ Steady green: The network port is On, and click OK.
management  Power on the server using the iBMC CLI.

You might also like