Professional Documents
Culture Documents
Pr039-Dxc-Noc-U-Ir-Etc-001-Irrigation With Etisalat
Pr039-Dxc-Noc-U-Ir-Etc-001-Irrigation With Etisalat
Pr039-Dxc-Noc-U-Ir-Etc-001-Irrigation With Etisalat
AL WASL STREET
JUMEIRAH ROAD
N
E
W
S
BURJ AL ARAB
JUMEIRAH LIVING
-11)
MADINAT
D (E
UMM SUQEIM ROAD
D ST
ROA
ABDULAZIZ SAUBIN
ED
KING SALMAN
ZAY
IKH
SHE
AL SUFOUH
NOTES
IRRIGATION DUCT No. (05) 2 WAY 1. ALL COORDINATES ARE IN DLTM SYSTEM.
150Ø uPVC & 1 WAY 300Ø uPVC 2. ALL DIMENSIONS ARE IN MILIMETERS UNLESS
A B OTHERWISE STATED.
IRRIGATION DUCT No. (01) 2 WAY E=486099.143 E=486102.330 SPLIT DUCT No.(01) 3. THE EXISTING UTILITY INFORMATION IS SHOWN
150Ø uPVC & 1 WAY 300Ø uPVC N=2780628.566 N=2780619.906 E=486213.262 AS PER INFORMATION NOC#31052020-2166.
A B FL = 4.197 FL = 4.12 N=2780502.976 4. EACH CLUSTER WILL HAVE ONE IRRIGATION SUPPLY
E=485600.812 E=485594.161 PT = 3.02 PT = 3.02 E=486199.851 CONNECTION. THE DISTRIBUTION OF IRRIGATION
N=2781011.946 N=2781004.142 LENGTH=9.3m N=2780484.367 WITHIN CLUSTER SHALL BE AS PER BUILDING DESIGN.
FL = 7.811 FL = 7.980 5. LOCATION OF IRRIGATION SUPPLY CONNECTION ARE
LENGTH=10.00m
PT = 6.711 PT = 6.880 TENTATIVE AND SUBJECT TO BUILDING MEP DESIGN.
6. CONCRETE CLASS 25/20 SURROUND SHALL BE PROVIDED AS
LENGTH=10.24m
ALTERNATIVE TO SAND WHERE "Y" IS LESS THAN 1.00 M
IRRIGATION DUCT No. (08) 2 WAY 7. COVER TO DUCTS SHALL HAVE MINIMUM DEPTH OF Ø900 MM.
150Ø uPVC & 1 WAY 300Ø uPVC SPECIFICATION FROM FINISH ROAD LEVEL AS SHOWN MEASURED
A B AT SITE WITH DRAW CORD.
E=486209.455 E=486199.519
A
B
A
B
N=2780500.951 N=2780486.952
FL = 3.268 FL = 3.31 LEGEND
PT = 2.168 PT = 2.168
LENGTH=15.44m EXISTING
A DM IRRIGATION NETWORK
DM CONDUIT
A BA B
EXISTING LINES TO BE REMOVED AND RELOCATE
A PULL BOX
IRRIGATION DUCT No. (04) 2 WAY
IRRIGATION DUCT No. (03) 2 WAY
IRRIGATION DUCT No. (02) 2 WAY 150Ø uPVC & 1 WAY 300Ø uPVC A
150Ø uPVC & 1 WAY 300Ø uPVC
150Ø uPVC & 1 WAY 300Ø uPVC
A B A
150 mm DIA
A B
A B E=485972.170 E=485982.172
E=485784.882 E=485793.205 B B 50 mm DIA uPVC.
E=485773.439 E=485781.780 N=2780707.055 N=2780710.368
N=2780835.141 N=2780828.695
N=2780844.006 N=2780837.546 FL = 4.730 FL = 4.65 SPLIT DUCT No.(01)
FL = 6.104 FL = 6.109
FL = 6.195 FL = 6.129
PT = 5.004 PT = 5.009
PT = 3.55 PT = 3.55
E=486213.262
ABANDONED SIGN FOR LINE
PT = 5.095 PT = 5.029 LENGTH=10.42m
LENGTH=10.53m N=2780502.976
LENGTH=10.55m PROPOSED
E=486199.851
IRRIGATION DUCT No. (06) 2 WAY IRRIGATION DUCT No. (07) 2 WAY N=2780484.367 PROPOSED LOCATED IRRIGATION MAIN LINE
150Ø uPVC & 1 WAY 300Ø uPVC 150Ø uPVC & 1 WAY 300Ø uPVC LENGTH=22.93m PROPOSED LOCATED IRRIGATION CONDUIT
A B A B
E=486088.571 E=486093.364 E=486102.158 E=486107.830 SPLIT DUCT No.(02) Ø150mm uPVC TSE SUPPLY LINE
N=2780586.798 N=2780577.074 N=2780564.983 N=2780557.017 E=486171.205 Ø200mm uPVC LINE
FL = 4.235 FL = 4.075 FL = 4.060 FL = 3.907 N=2780444.705 Ø150mm uPVC LINE
PT = 2.975 PT = 2.975 PT = 2.807 PT = 2.807 E=486163.514 2x150
LENGTH=11m N=2780434.120
PROPOSED DUCT CROSSING
LENGTH=9.8m 1x300
LENGTH=13.08m PROPOSED DUCT CROSSING
SPLIT DUCT No.(03) CONCRETE SURROUNDING
E=486152.759
SPLIT DUCT AND CONCRETE SURROUND PROTECTION
N=2780419.046
E=486144.818 OPEN CUT AND ROAD REINSTATEMENT
N=2780408.111
LENGTH=13.51m EXISTING IRRIGATION REPLACE WITH GRP PIPE WITH
REINFORCED CONCRETE SURROUND
TIE IN POINT NETWORK WILL BE RELOCATED
EXISTING 150mm E=486138.468 TO PROPOSED CENTER MEDIAN REMOVE AND REPLACE EXISTING PIPE
IRRIGATION N=2780399.071 WITH GRP AND STEEL SLEEVE
DISTRIBUTION TO BE PRO.BEND 11.25° GATE VALVE
RELOCATED TO DM E=486133.354
N=2780394.208 E=486150.055 ENDCAP
SEWER HC CORRIDOR
LENGTH = 121m
PRO. BEND 11.25 ° N=2780380.653 EXISTING LINES TO BE REMOVED
E=486141.760 AND RELOCATE
PROPOSED RELOCATED N=2780367.031
150mm UPVC IRRIGATION PROJECT BOUNDARY
LINE LENGTH = 122m
PROPOSED RELOCATED TIE-IN POINT WITH EXISTING
PULL BOX
PROPOSED SLEEVE AND
CONCRETE SURROUND PROPOSED RELOCATED IC INLET VALVE CHAMBER
TO PROTECT IRRIGATION MAIN LINE =
IRRI LINE L=6M FM FLOW METER CHAMBER
103.50
PULL BOX
6.00
SPLIT DUCT No.(04) PROPOSED RELOCATED
E=486087.731 IRRIGATION CONDUIT =
N=2780330.752 118.50 IFC REFERNCE NO:CI-IR-10-03-002
E=486071.613
PROPOSED RELOCATED IFC REFERNCE NO:CI-IR-00-11-002
N=2780308.294 GATE VALVE CHAMBER - 1
IRRIGATION DUCT No. (11)
(10) 2 WAY
150Ø uPVC & 1 WAY 300Ø uPVC
LENGTH=27.64m
9-2 9-2 FL = 3.297
PT = 2.197
E=486067.950
IFC REFERNCE NO:CI-IR-00-11-004
6.00
FL = 4.065 FL = 4.181 E=485973.909 E=486004.822 GATE VALVE CHAMBER
PT = 2.865 PT = 2.981 N=2780354.753 N=2780330.823
LENGTH=54m FL = 4.197 FL = 4.085
TO BE RELOCATED
TEE 200 x 150 x 150
PT = 2.997 PT = 2.885 FL = 3.314
00 10-02-2024 CONSTRUCTION NOC KR MK MM
LENGTH=39.2m PT = 2.214 REV. DATE DESCRIPTION Drawn Checked Approved
PROPOSED RELOCATED E=486065.237
Client:-
IC
N=2780299.243
8-1 GATE VALVE CHAMBER - 2
FM
FL = 3.415
PT = 2.315 E=486086.386
A B A B PROPOSED TIE IN POINT
E=486059.869 N=2780284.051
N=2780299.802 FL = 3.210
PT = 2.110 E=486082.993
E=486068.285 N=2780286.592
END CAP N=2780297.062
FL = 3.563 CH=0+000.00
Existing 150mm dia uPVC PT = 2.463
pipe PROPOSED TIE IN Existing 150mm dia uPVC E=486052.435
POINT pipe
FL= 3.943 N=2780299.270
PT = 1.656 CH=0+143.02
1x300
2x150
EXISTING 600mmØ IRRIGATION
LINE TO BE REMOVED AND REPLACE
WITH GRP AND STEEL SLEEVE
Existing 150mm dia uPVC LENGTH (m) = 10 Existing 150mm dia uPVC
pipe
8-1 pipe
Supervision:-
Designer:-
EXISTING
ETISALAT NETWORK Contractor:-
EXISTING CHAMBER
PROPOSED DX CONTRACTING L.L.C
P.O.Box 391516,Dubai , United Arab Emirates
6WAY D54 100MM MAIN DUCT Tel +971 4 451 2516 Fax +971 4 451 1381
PR039-DXC-NOC-U-IR-ETC-001 00
KEY PLAN
AL WASL STREET
JUMEIRAH ROAD
N
E
W
S
BURJ AL ARAB
9.60
7.60
JUMEIRAH LIVING
5.80
-11)
MADINAT
D (E
UMM SUQEIM ROAD
3.30
D ST
ROA
ABDULAZIZ SAUBIN
ED
KING SALMAN
ZAY
IKH
SHE
AL SUFOUH
NOTES
1. ALL COORDINATES ARE IN DLTM SYSTEM.
2. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE STATED.
3. THE EXISTING UTILITY INFORMATION IS SHOWN AS PER
INFORMATION NOC#31052020-2166.
4. EACH CLUSTER WILL HAVE ONE IRRIGATION SUPPLY CONNECTION.
THE DISTRIBUTION OF IRRIGATION WITHIN CLUSTER SHALL BE
AS PER BUILDING DESIGN.
5. LOCATION OF IRRIGATION SUPPLY CONNECTION ARE TENTATIVE
AND SUBJECT TO BUILDING MEP DESIGN.
" RTA " TYPICAL SERVICE RESERVATION
LEGEND
CROSS SECTION FOR CORRIDOR WIDTH OF 45.70m
EXISTING
48.24 R.O.W
21.45
EX. ETISALAT
EX. ETISALAT
(200Ø uPVC)
EX. ETISALAT
EX. ETISALAT
EX. ETISALAT
(250Ø uPVC)
(250Ø uPVC)
(150Ø AC)
(150Ø AC)
9-2 EXISTING UTILITY SERVICES RESERVATION CROSS SECTION FOR 48.24m R.O.W
PROPOSED RELOCATED
IRRIGATION CONDUIT 50MM
26.90
21.98 PROPOSED RELOCATED
IRRIGATION LINE
Supervision:-
3.43
2.60 EXISTING MEDIAN
Designer:-
1.75
DETAIL A
PROPOSED PROTECTION FOR EX.ETC Contractor:-
IRRI LINE
OVERALL
EXISTING IRRIGATION LINE Drawing Title:-
TO BE RELOCATED TO
PROPOSED MEDIAN
CROSS SECTION EXISTING RELOCATION
SEWERAGE (H.C)
EX. ETISALAT
PR039-DXC-NOC-U-IR-ETC-002 00
KEY PLAN
AL WASL STREET
JUMEIRAH ROAD
N
E
W
S
BURJ AL ARAB
JUMEIRAH LIVING
-11)
MADINAT
D (E
UMM SUQEIM ROAD
D ST
ROA
ABDULAZIZ SAUBIN
ED
KING SALMAN
ZAY
IKH
SHE
AL SUFOUH
NOTES
1. ALL COORDINATES ARE IN DLTM SYSTEM.
2. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE STATED.
TO BE PROTECTED
PROP. SEWERAGE
EX. SWD MANHOLE
PROP. EITC-Du / ITS
EX.DEWA (132kV)
EX.DEWA (11kV)
EX. DEWA (11kV)
4. EACH CLUSTER WILL HAVE ONE IRRIGATION SUPPLY CONNECTION.
EX. IRRIGATION
PROP. DEWA (LV)
EX. SEWERAGE
PROP. DEWA(HV)
EX.11kV
EX. IRRIGATION
EX. IRRIGATION
EX. IRRIGATION
EX.ETISALAT
(250Ø uPVC)
EX. ETISALAT
(250Ø uPVC)
(100Ø uPVC)
(450Ø GRP)
(315Ø uPVC)
AS PER BUILDING DESIGN.
(200Ø uPVC)
(150Ø uPVC)
(600Ø AC)
5. LOCATION OF IRRIGATION SUPPLY CONNECTION ARE TENTATIVE
AND SUBJECT TO BUILDING MEP DESIGN.
(H.C)
LEGEND
EXISTING
8-1 PROPOSED UTILITY SERVICES RESERVATION CROSS SECTION AS MASTER PLAN
EX. IRRIGATION
EX. IRRIGATION
EX. SEWERAGE
EX. IRRIGATION
EX. ETISALAT
EX. IRRIGATION
EX. IRRIGATION
EX. ETISALAT
(250Ø uPVC)
(150Ø uPVC)
REV. DATE DESCRIPTION Drawn Checked Approved
(250Ø uPVC)
(100Ø uPVC)
(450Ø GRP)
(315Ø uPVC)
(200Ø uPVC)
(150Ø uPVC)
(600Ø AC)
Client:-
8-1 EXISTING UTILITY SERVICES RESERVATION CROSS SECTION FOR 73.77m R.O.W
Supervision:-
Designer:-
Project / Contract:-
OGL=4.312
MADINAT JUMEIRAH LIVING
OVERALL
Drawing Title:-
PIPE TOP
CROSS SECTION EXISTING RELOCATION
PROPOSED INLET CHAMBER LEVEL=1.796 IRRIGATION LINE WITH ETISALAT SECTION 8-1
EX.ETISALAT
EX. IRRIGATION
PR039-DXC-NOC-U-IR-ETC-003 00