Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

RecoverPoint: WARNING: RPA fan failure detected. Contact EMC Customer Service. |... https://www.dell.com/support/kbdoc/zh-cn/article/lkbprint?ArticleNumber=00007879...

文章编号: 000078797

� 打印

RecoverPoint: WARNING: RPA fan failure detected. Contact EMC Customer Service.

受众级别: 内部

文章内容

症状

Error msg (CLI log):

WARNING: RPA fan failure detected. Contact EMC Customer Service.

Error msg (OMSA log):

Event : Power Supply Critical


Console Alert : Selected
Broadcast Message : Not selected
Execute Application : Not selected
Absolute path to the application : Not selected
Severity : Ok
ID : 1102
Date and Time : Fri Jan 31 02:29:11 2014
Category : Instrumentation Service
Description : Fan sensor returned to a normal value Sensor location: System
Fan 6B Chassis location: Main System Chassis Previous state was: Critical
(Failed) Fan sensor value (in RPM): 15120
Severity : Critical
ID : 1104
Date and Time : Fri Jan 31 02:28:48 2014
Category : Instrumentation Service
Description : Fan sensor detected a failure value Sensor location: System Fan
6B Chassis location: Main System Chassis Previous state was: OK (Normal) Fan
sensor value (in RPM): 360
...
Severity : Critical
ID : 1306
Date and Time : Wed Jan 22 03:16:19 2014
Category : Instrumentation Service
Description : Redundancy lost Redundancy unit: Pwr Unit Redund Chassis
location: Main System Chassis Previous redundancy state was: Lost Number of
devices required for full redundancy: 2

Severity : Critical
ID : 1354
Date and Time : Wed May 8 13:23:36 2013
Category : Instrumentation Service
Description : Power supply detected a failure Sensor location: PS 2 Status
Chassis location: Main System Chassis Previous state was: Unknown Power Supply
type: AC Power Supply state: Presence detected, AC lost

第1页 共3页 2023/2/13 15:01


RecoverPoint: WARNING: RPA fan failure detected. Contact EMC Customer Service. |... https://www.dell.com/support/kbdoc/zh-cn/article/lkbprint?ArticleNumber=00007879...

Severity : Critical
ID : 1306
Date and Time : Thu Feb 21 16:24:04 2013
Category : Instrumentation Service
Description : Redundancy lost Redundancy unit: System Board PS Redundancy
Chassis location: Main System Chassis Previous redundancy state was: Unknown

Error msg (extracted.TTA_RPA_CLUSTER.KBox1.2014.03.05.07.06.10/processes/usr/bin$ lessipmitoolselelist):

Power Unit Pwr Unit Redund | Redundancy Lost


2e8 | 12/20/2013 | 03:57:19 | Power Unit Pwr Unit Redund | Non-Redundant:
Sufficient from Redundant
2e9 | 12/20/2013 | 03:57:20 | Fan System Fan 2A | Lower Non-critical going low
| Reading 1426 < Threshold 1922 RPM
2ea | 12/20/2013 | 03:57:20 | Fan System Fan 2A | Lower Critical going low |
Reading 1426 < Threshold 1674 RPM
2eb | 12/20/2013 | 03:57:21 | Fan Fan Redundancy | Fully Redundant
2ec | 12/20/2013 | 03:57:21 | Fan Fan Redundancy | Redundancy Lost
2ed | 12/20/2013 | 03:57:21 | Fan Fan Redundancy | Non-Redundant: Sufficient
from Redundant
2ee | 12/20/2013 | 03:57:26 | Fan System Fan 2A | Lower Critical going low |
Reading 2728 < Threshold 1674 RPM
2ef | 12/20/2013 | 03:57:26 | Fan System Fan 2A | Lower Non-critical going low
| Reading 2728 < Threshold 1922 RPM
2f0 | 12/20/2013 | 03:59:23 | Power Supply PS1 Status | Predictive failure |
Asserted
...
39d | 01/31/2014 | 02:28:32 | Fan System Fan 6B | Lower Non-critical going low
| Reading 1800 < Threshold 1980 RPM
39e | 01/31/2014 | 02:28:33 | Fan System Fan 6B | Lower Critical going low |
Reading 0 < Threshold 1680 RPM
39f | 01/31/2014 | 02:28:34 | Fan Fan Redundancy | Non-Redundant: Sufficient
from Redundant
3a0 | 01/31/2014 | 02:28:34 | Fan Fan Redundancy | Non-Redundant: Insufficient
Resources
3a1 | 01/31/2014 | 02:28:49 | Fan System Fan 6B | Lower Critical going low |
Reading 2220 < Threshold 1680 RPM
3a2 | 01/31/2014 | 02:28:49 | Fan System Fan 6B | Lower Non-critical going low
| Reading 2220 < Threshold 1980 RPM

BIOS Version (kbox1/processes/usr/sbin/dmidecode):

Version: SE5C600.86B.01.06.0002.110120121539
原因

Fan failure warnings may be caused by power supply issues. However, since a power cycle clears them, RecoverPoint Engineering believe
that in these events are benign (although they cannot state that these warnings are false 100% of the time). See Resolution.

解决方案

W
Woorrkkaarroouunndd::

1. Reboot the RPA.


2. If step one did not help, do the following:
1. Shut down the RPA
2. Remove the power cord from the power supply unit of the affected RPA (disconnect the cord from the PSU or unplug it from the
wall)
3. Wait for 10 seconds and reinsert the power cord and boot the RPA.
4. Monitor the environment (RPA and site power).
3. A solution exists for this issue but intervention from EMC Technical Support personnel is required. Support can change parameters to
�lter these events. Contact the EMC Customer Support Center or your service representative for technical assistance and quote this

第2页 共3页 2023/2/13 15:01


RecoverPoint: WARNING: RPA fan failure detected. Contact EMC Customer Service. |... https://www.dell.com/support/kbdoc/zh-cn/article/lkbprint?ArticleNumber=00007879...

article number.

内部注意事项

SSuuppppoorrtt C
Ceenntteerr::

By changing a tweak the customer can choose to ignore the messages.

This will only clear these warnings from the GUI so they do not bother them.

In case both Resolution step one, and two did not help, there might be an ongoing H/W issue, OR electricity supply issue (usually all RPA's
on the site are experiencing the problem), you can do the following:

• Disable fan monitoring by changing the tt__hhw


wEEvveennttssM
MoonniittoorrFFaann tweak to ffaallssee on tweak.params.san_diag (can be done via
boxmgmt or someone with root access) and reboot the RPA.
• To change the tweak under boxmgmt account:

1. SSH to each RPA using boxmgmt account


2. Navigate to [2] Setup -> [5] System internal operations -> [3] Appliance con�g params -> [3] Change appliance con�g
param value then enter tt__hhw
wEEvveennttssM
MoonniittoorrFFaann and enter value ffaallssee.

For example:

Enter tweak_param name: tt__hhw


wEEvveennttssM
MoonniittoorrFFaann
Enter tweak_param value (Default 'true'): ffaallssee
Enter your name:
Tweak parameters modi�ed successfully.

For more information, consult Bugzilla defect number 38273, 38452, 38974, and 39131.

Bugzilla access is only available to authorized Customer Service Representatives.

文章属性

受影响的产品

RecoverPoint

产品

RecoverPoint, RecoverPoint Gen5 Server

上次发布日期

20 11月 2020

版本

文章类型
Solution

第3页 共3页 2023/2/13 15:01