Professional Documents
Culture Documents
Titanium Dioxide Nanotubes Addition To Self-Adhesive Resin Cement - Effect On Physical and Biological Properties
Titanium Dioxide Nanotubes Addition To Self-Adhesive Resin Cement - Effect On Physical and Biological Properties
Titanium Dioxide Nanotubes Addition To Self-Adhesive Resin Cement - Effect On Physical and Biological Properties
ScienceDirect
a r t i c l e i n f o a b s t r a c t
Article history: Objectives. This study has investigated the influence of Titanium dioxide nanotubes (TiO2 -
Received 31 January 2017 nt) addition to self-adhesive resin cement on the degree of conversion, water sorption, and
Received in revised form water solubility, mechanical and biological properties.
10 April 2017 Methods. A commercially available auto-adhesive resin cement (RelyX U200TM , 3M ESPE) was
Accepted 28 April 2017 reinforced with varying amounts of nanotubes (0.3, 0.6, 0.9 wt%) and evaluated at different
curing modes (self- and dual cure). The DC in different times (3, 6, 9, 12 and 15 min), water
sorption (Ws) and solubility (Sl), 3-point flexural strength (!f), elastic modulus (E), Knoop
Keywords: microhardness (H) and viability of NIH/3T3 fibroblasts were performed to characterize the
Dental cements resin cement.
Polymerization Results. Reinforced self-adhesive resin cement, regardless of concentration, increased the
Nanotechnology DC for the self- and dual-curing modes at all times studied. The concentration of the TiO2 -
Nanotubes nt and the curing mode did not influence the Ws and Sl. Regarding !f, concentrations of
Titanium both 0.3 and 0.9 wt% for self-curing mode resulted in data similar to that of dual-curing
Physical and chemical properties unreinforced cement. The E increased with the addition of 0.9 wt% for self-cure mode and
Mechanical phenomena H increased with 0.6 and 0.9 wt% for both curing modes. Cytotoxicity assays revealed that
reinforced cements were biocompatible.
Significance. TiO2 -nt reinforced self-adhesive resin cement are promising materials for use
in indirect dental restorations. Taken together, self-adhesive resin cement reinforced with
TiO2 -nt exhibited physicochemical and mechanical properties superior to those of unrein-
forced cements, without compromising their cellular viability.
© 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
∗
Corresponding author at: Bauru School of Dentistry, University of São Paulo, Al. Octávio Pinheiro Brisola, 9-75, Vila Universitária, 17012-901
Bauru, SP, Brazil.
E-mail address: afborges@fob.usp.br (A.F.S. Borges).
http://dx.doi.org/10.1016/j.dental.2017.04.022
0109-5641/© 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
d e n t a l m a t e r i a l s 3 3 ( 2 0 1 7 ) 866–875 867
For cell viability study, the factors were as follows: (1) con-
1. Introduction centration of TiO2 -nt (0.3, 0.6 and 0.9 wt.%) and (2) time (24,
48 and 72 h). Two polymerization conditions were used: self-
Self-adhesive resin cements were developed to clinical time
and dual-cured polymerization. For the self-curing condition,
by simplifying cementation procedures due to the elimination
the cement handling and the specimens’ preparation were
of the acid etching and application of adhesive steps [1–3].
performed in an environment with room light. Thirty min-
Its adhesive properties are attributed to the presence of the
utes after cement handling, specimens were removed from
modified acidic group’s methacrylate monomers that allows
the custom devices used in each test and stored in distilled
the infiltration and demineralization of the substrate, that
water at 37 ◦ C. For the dual-curing condition, the specimens
result in micromechanical retention and chemical bonding
were handled in an environment with room light, embedded
with hydroxyapatite [3].
in custom devices used in each test of the study. Nine min-
However, the presence of these acidic monomers in self-
utes after handling of self-adhesive resin cement, the light
adhesive resin cements may adversely affect the degree
source 780 mW/cm3 DB LED 686 (Dabi Atlante, Ribeirão Preto,
of conversion (DC) because of its interference with the
Brazil) was applied for 20 s in different areas of the specimens
amine coinitiator, which results in changes in the curing [4]
so that the whole specimen was reached by light. The 9 min
and the loss of some physical and mechanical properties
time was used once delay in light activation had shown to
[5–7]. Moreover, being dual-cured, not all cements present
improve properties of resin-based cements [18,19].
the same conversion rates of monomers when self- or/and
The specimens of the self-adhesive resin cement were
light-activated. In general, light-activation promotes higher
randomly assigned into 8 groups: SCT = self-adhesive resin
conversion of monomers [8].
cement in self-cure condition, which has no TiO2 -nt;
To improve certain properties of resin materials, the addi-
S03 = self-adhesive resin cement in self-cure condition with
tion of titanium dioxide nanostructures have demonstrated
the addition of 0.3 wt.% of TiO2 -nt; S06 = self-adhesive resin
positive results in the behavior of polymeric materials such
cement in self-cure condition with the addition of 0.6 wt.%
as resin composites [9,10], flowable resin composites [11],
of TiO2 -nt; S09 = self-adhesive resin cement in self-cure
orthodontic resin cements [12] and glass ionomer cements
condition with the addition of 0.9 wt.% of TiO2 -nt; DCT = self-
[13]. The decrease in size of different oxides at the nanoscale
adhesive resin cement in dual-cure condition, which has no
promotes a wide range of applications in different materials
TiO2 -nt; D03 = self-adhesive resin cement in dual-cure con-
because their behavior changes when compared to the bulk
dition with the addition of 0.3 wt.% of TiO2 -nt, dual cure;
size [14], making it an effective functional material [15]. Nano-
D06 = self-adhesive resin cement in dual-cure condition with
sized oxides such as TiO2 can provide unique physical and
the addition of 0.6 wt.% of TiO2 -nt; D09 = self-adhesive resin
chemical properties due to their small size and high density
cement in dual-cure condition with the addition of 0.9 wt.% of
of surface sites, increasing their reactivity and interaction with
TiO2 -nt.
the environment [16]. In particular, the nanotubes’ shape pro-
vides a large surface area that can give rise to strong internal
and external interactions with the matrix in which they are
embedded, chemical stability and a high refractive index [17].
2.2. Specimen preparation
Whereas oxides at the nanoscale can be easily incor-
porated into the resin-based materials when manipulated,
TiO2 -nt were obtained from a commercial mixture of anatase
adding these to the self-adhesive resin cement can be an
TiO2 powder (Sigma–Aldrich, St. Louis, USA) mixed with an
alternative to improve the overall performance of the indirect
alkaline solution of sodium hydroxide (NaOH; 10 M), which
restoration. Therefore, the aim of the current investigation
remained for 24 h at 120 ◦ C in an atmospheric pressure envi-
was to determine the physical–chemical, mechanical and
ronment Teflon container. Then, the mixture was washed with
biological properties of a self-adhesive resin cement (RelyX
deionized water and hydrochloric acid (HCl; 0.1 M) sequen-
U200TM —Seefeld, Germany) in the presence of TiO2 -nt at three
tially and repeatedly until reaching a pH of 4. After that, the
different concentrations: 0.3%, 0.6% and 0.9% (w/w).
mixture were placed in a furnace at 200 ◦ C for 24 h to eliminate
the liquid phase and to obtain the final powdered material [20].
The nanotubes were measured with open source Image J soft-
2. Materials and methods ware and had an average diameter of 10 nm and were 200 nm
in length, formed by a single sheet of spiral-wound TiO2.
2.1. Experimental design The image was obtained by Transmission Electron Microscopy
(TEM) (CM 200, Phillps, Netherlands) with electrons acceler-
The factor under study was the incorporation of different con- ation of 200 kV [20]. The resin cement that had the same
centrations of TiO2 -nt (w/w) into self-adhesive resin cement portion of base and catalyst paste dispensed by packing clicker
RelyX U200TM . For degree of conversion (DC), the study fac- was dispensed on a mixing pad and weighed on a precision
tors were as follows: (1) concentration of TiO2 -nt (0.3, 0.6 and scale of 0.0001 g (Denver Instrument, São Paulo, Brazil). Then,
0.9 wt.%), (2) curing mode dual- and self-curing and (3) time (3, the nanotubes were weighed with the value corresponding
6, 9, 12 and 15 min). For water sorption (WS) and solubility (SL), to the resin cement weigh. TiO2 -nt was manually added to
flexural strength (!f), modulus of elasticity (E) and hardness the base paste and handled for 10 s. Then, the base paste
(H), the study factors were: (1) concentration of TiO2 -nt (0.3, and TiO2 -nt were mixed with the catalyst paste for another
0.6 and 0.9 wt%) and (2) curing mode (dual- and self-curing). 10 s.
868 d e n t a l m a t e r i a l s 3 3 ( 2 0 1 7 ) 866–875
made in the central area of each specimen, and the arithmeti- enrollment period of 24 h, the culture medium was replaced by
cal average was used for subsequent statistical analysis. DMEM 10% FCS conditioned with the cement specimens. Each
plate was examined at an experimental time of 24, 48 and 72 h
after the addition of conditioned medium. After each exper-
2.6. Biological analyses
imental period, the culture medium was removed, the cells
were washed with phosphate buffered saline solution (PBS)
2.6.1. Preparation of specimens
and then an MTT reduction test.
Four disks (10 mm ø × 2 mm) of resin cement were pre-
pared for each concentration-studied TiO2 -nt. After light
curing, the specimens were autoclaved separately. To evaluate 2.6.3. Analysis of cell metabolism MTT assay
cell viability (n = 8), an MTT (3-(4,5-dimethylthiazol-2-yl)-2,5- During each experimental period (24, 48 and 72 h), the cells
diphenyltetrazolium bromide) assay was performed using were washed with PBS and then incubated in 0.5 mg/ml
only the dual-curing condition. The studied groups were DCT, solution (MTT/DMEM) for an MTT assay. This solution was
D03, D06, D09, positive control (CP) and negative control (CN). prepared at the time of use and filtered through a Millipore
filter (0.22 mM) before being added to the plates. After this
procedure, the plates remained in the greenhouse for 4 h at
2.6.2. Cell culture 37 ◦ C and 5% CO2 ; then, the solution was removed, and the
For cell culture, mouse fibroblasts were used in the NIH3T3 insoluble pigment reduced intracellularly was taken up in
®
line P13 (ATCC , Manassas, USA). The cells were cul- dimethylsulfoxide and left at room temperature for 30 min.
®
tured in DMEM-Dulbecco’s modified Eagle (Aldrich Sigma, The absorbance was measured at 562 nm wavelength reader
St. Louis, USA), supplemented with 1% antibiotics (peni- (Synergy H1 monochromator-based, Biotek, Winooski, USA).
®
cillin/streptomycin from Gibco , Waltham, USA) and 10% FBS
®
(fetal bovine serum from Gibco ) and remained incubated
2.7. Statistical analyses
at 37 ◦ C with 5% carbon dioxide (CO2 ). After reaching a sub-
confluence stage, a subculture was formed using the trypsin
Data were analyzed using the Shapiro–Wilk normality test.
enzyme responsible for dissociating the culture bottle cells
® The DC data were subjected to ANOVA with repeated-
(0.25% trypsin, 1 mM EDTA from Sigma–Aldrich ). After 5 min
measures followed by Tukey’s HSD (˛ = 0.05). WS, SL and each
◦
in an oven at 37 C with 5% (CO2 ), the trypsin was inactivated
mechanical and biological property were submitted to two-
with DMEM culture medium with 10% FCS. The cells were
way ANOVA and Tukey’s HSD (˛ = 0.05).
transferred to a 50-ml falcon tube (Corning, NY, USA) and cen-
trifuged at 1200 rpm for 5 min at 20 ◦ C. After centrifugation,
the supernatant was discarded, and the cells were suspended 3. Results
again in a fresh DMEM medium with 10% FCS. After that, the
cell count was performed using a trypan blue protocol opti- 3.1. Degree of conversion
cal microscope (Olympus, Japan). This dye is responsible for
staining the viable cells as it penetrates the dead cells because The mean values and standard deviations are detailed in
their membranes can no longer eliminate it. Subsequently, the Table 1.
®
cells were plated in 96-well microplates (TPP , Trasadingen, There were significant differences between curing mode
Switzerland) for a colorimetric assay, 8-well microplates for (p = 0.000) and addition of nanotubes (p = 0.0000). The inter-
each group. The resin-cement specimens were placed in con- action was also found to be significant (p = 0.0000). The
tact with the culture medium following the recommendations DC increases with time (p = 0.0000). The addition of TiO2 -
of ISO 10993-5 [23] (1 cm2 /ml). To this end, the total area of nt, regardless of concentration, increased the DC values
the disks was calculated (28.26 cm2 ) to evaluate the amount for both self- and dual-curing conditions at all times stud-
of conditioned media (28.26 ml). The specimens remained in ied. The DC analysis at 3 min showed that the addition
the oven at 37 ◦ C for 24 h. After this, the pH at which the disks of 0.3% (S03 = 26.76%; D03 = 26.11%) and 0.9% (S09 = 25.62%;
were immersed was measured. For the viability assays, cells D09 = 26.05%) of TiO2 -nt in the self-adhesive resin cement
®
were plated 2 × 103/well in 96-well plates (TPP ). After the in both polymerization conditions showed the highest val-
Table 1 – Mean values and standard deviations of the DC (%).Within a column or row, values denoted by similar
superscript letters are not significantly different (p > 0.05).
Groups Time
Table 2 – Average of the sorption (WS) and solubility (SL) values (mg/mm3 ). Within a row, values denoted by similar
superscript letters are not significantly different (p > 0.05).
Groups
ues, similar to the SCT group at 12 min (SCT = 25.89%). At 3.2. WS and SL
6 min, an addition of 0.9% TiO2 -nt (S09 = 40.46%; D09 = 39.89%)
showed higher results when compared to other groups. The There was no significant difference between groups regardless
DCT control group showed an increase in the DC at a mean the concentration of nanotubes added and polymerization
time of 9 min (28.51%) compared to the SCT group (14.62%) condition (p > 0.05). The mean values and standard deviations
that received no light. Regardless of the TiO2 -nt concentration for WS and SL can be observed in Table 2. After a Pearson cor-
added, S03, S06 and S09 showed higher values than the DCT relation analysis, an 80% correlation (r > 0.800) was observed
group at 9 and 12 min. At 15 min, only S06 group was similar to between WS and SL in all groups studied regardless of the
the DCT group. At 15 min, the best result was found in the D03 polymerization condition. Figs. 2 and 3 show the direct rela-
group (48.09%), with statistical differences for S09 (46.51%). tionship between the WS and SL of each group for the self-
S03 (45.76%), D06 (45.77%) and D09 (45.51%) had no difference and dual-curing conditions, respectively.
between each other. The SCT group showed the lowest DC.
Table 3 – Mean values and standard deviation (SD) of flexural strength (!f), elastic modulus (E) and Microhardness (H) for
each group. Within a row, values denoted by similar superscript letters are not significantly different (p > 0.05).
Groups
Fig. 5 – Optical microscopy images for 24, 48 and 72 h (columns) for all groups: CN, CP, DCT, D03, D06 and D09 (lines).
d e n t a l m a t e r i a l s 3 3 ( 2 0 1 7 ) 866–875 873
physical–chemical, mechanical and biological behaviors were at <50 nm, exists a confinement effect of electron pairs that
improved. These improvements, especially in the self-curing results in an increase of energy between the valence band
condition, are important for the longevity and clinical perfor- and the band gap of the material [27]. This energy is expressed
mance of this cement. chemically as a free radical (HO• ) [10] that likely provides addi-
The dual-curing condition proposed in this study simulates tional site links between the monomers.
the use of the self-adhesive resin cement in the cementation The addition of TiO2 -nt and the polymerization condi-
of indirect restorations containing infrastructures that do not tion did not influence the WS and SL of the self-adhesive
allow the passage of light, such as Y-TZP, in which the cement resin cement. According to ISO 4049 [21], the value of clin-
on the restoration margins receives the curing light after a few ically acceptable WS for polymeric materials is limited to
minutes of cementation. 40 !g/mm3 and the SL is less than 7.5 !g/mm3 . The results
The dual-curing protocol performed in this study is based found in this study for WS (from 36.19 to 38.47 !g/mm3 )
on the one employed by Soares et al. [19] in which the light- are in accordance with the ISO’s recommendations, but SL
activation was performed 6 min after the handling of the resin (7.66–8.14 !g/mm3 ) was above the values stipulated as ideal.
cement without impairing its mechanical properties. This This fact was elucidated once the resin-based materials con-
delay in light activation has shown to improve properties of taining acid functional monomers, such as carboxyl groups
resin-based cements [18]. or phosphate, are significantly more hydrophilic than the
Regardless of the percentage added (0.3%, 0.6%, or 0.9%), materials without functional monomers, which contain only
the DC was higher at all time points (3, 6, 9, 12, and 15 min) conventional TEGDMA and BIS-GMA [28,29] and are therefore
compared to the control for both polymerization modes. The more prone to WS and SL [30]. The amount of inorganic parti-
non-reinforced cement did not reach the same DC in SCT cles [31] and the nature of the bonds between the particles and
when compared to the condition in which it was submitted the organic matrix are important [32] because the diffusion of
to light-activation (DCT), which is in agreement with other water between the particles can occur [33]. Furthermore the
studies [6,24,25]. Thus, the chemical reaction alone of the eval- cement in this study did not react with the calcium of dentin
uated dual-cured resin cement without light-activation seems substrate, that promotes additional chemical bond and collab-
therefore not to be sufficient to achieve reasonable levels of orate with the polymerization process [3], since it accelerates
conversion of C C double bonds for polymer formation after the neutralization of the low pH of the cement [34].
15 min of mixing. The photo-initiator system allows a fast Some residual unpolymerized monomers may leach into
reaction and high conversion when the materials are sub- the oral cavity, but most remain trapped in the already
jected to light-activation [6]. polymerized cement [30]. Those that are released into the
The addition of 0.3% to 0.9% of TiO2 -nt in the self-curing environment can cause adverse biological reactions, penetrat-
mode increased the DC to values close to the ones obtained ing the dentin tubules and pulp [35]. Those that are stuck
by the dual-curing condition without TiO2 -nt additive (DCT), in cement reduce the clinical longevity of the material and
which would justify the use of TiO2 -nt additives in clinical sit- undergo oxidation and hydrolytic degradation, as evidenced
uations that rely exclusively on chemical polymerization such by discoloration of the cementation of the margins [36]. This
as the cementation of fiber-reinforced posts in root canals. It condition is directly related to the cytotoxicity of the cement,
should be noted that the results of this study demonstrate that which is another important factor to be analyzed. In the cur-
the relationship between the addition of TiO2 -nt and DC is not rent study, the indirect fibroblast viability was assessed using
straightforward, which means that the increase of the con- a MTT and Crystal Violet assay. The results showed that the
centration of TiO2 -nt do not necessarily promotes greater DC incorporation of TiO2 -nt at 24, 48 and 72 h were the same for
values. This result can be justified by the fact that the addition the CP group, indicating that the addition did not affect cell
of 0.6% promotes an agglomeration of nanotubes [10] resulting viability in vitro during these periods for the dual-curing con-
in links attached to other already polymerized monomer and dition. However, the DCT group at 24 h showed a significant
preventing new connections among them [26]. On the other difference in cell viability when compared to CP. This result
hand, when 0.9% was added, the reaction might have been so can be explained by the relationship between the type of poly-
fast that agglomeration of nanotubes may have been smaller merization employed and the DC obtained with regard to the
and did not affect the link of monomers. cytotoxicity of resin cements [37]. The cements with lower DC
Even with acceptable values of DC in the dual-curing showed a significant decrease in cell survival when compared
mode, with the addition of 0.3% TiO2 -nt the values increased to cements with the highest DC [38].
16%. Most likely, the insertion of this percentage allowed the The !f values obtained in this study showed that the pres-
cement to stay more reactive to new connections between ence of TiO2 -nt influenced the results. The inclusion of 0.3
monomers remaining in equilibrium with the polymer net- and 0.9% of TiO2 -nt increased the !f value in the self-curing
work that was forming. Increasing concentrations (0.6 and condition (S03 and S09) and is similar to the average value of
0.9%) of TiO2 -nt, however, showed an average increase of only DCT. The linear relationship between the increased amount
10%, likely due to the rapid increase in viscosity generated by of inserted nanotubes and an increase in strength was not
the conversion of the monomers. observed. This may be associated with the higher conversion
The increase of the DC with the addition of TiO2 -nt to the of monomers to concentrations of 0.3% and 0.9% in the same
cement shows an inducer potential, with the nanotubes pos- polymerization condition because they are properties which
sibly acting as a reaction coinitiator and contributing to the have a direct relationship [39,40]. For the dual-curing condi-
increase of strong crosslinked points formed in the polymeric tion, the inclusion of 0.6% of TiO2 -nt decreased the !f value
network [10]. This is because at the nanoscale, in particular compared to the control (DCT), as already noted for the DC.
874 d e n t a l m a t e r i a l s 3 3 ( 2 0 1 7 ) 866–875
resins by adding titanium dioxide nanoparticles. Dent Mater [30] Petropoulou A, Vrochari AD, Hellwig E, Stampf S, Polydorou
2011;27(10):972–82. O. Water sorption and water solubility of self-etching and
[11] Dafar MO, Grol MW, Canham PB, Dixon SJ, Rizkalla AS. self-adhesive resin cements. J Prosthet Dent
Reinforcement of flowable dental composites with titanium 2015;114(5):674–9.
dioxide nanotubes. Dent Mater 2016;32(6):817–26. [31] Toledano M, Osorio R, Osorio E, Fuentes V, Prati C,
[12] Poosti M, Ramazanzadeh B, Zebarjad M, Javadzadeh P, Garcia-Godoy F. Sorption and solubility of resin-based
Naderinasab M, Shakeri MT. Shear bond strength and restorative dental materials. J Dent 2003;31(1):43–50.
antibacterial effects of orthodontic composite containing [32] Mese A, Burrow MF, Tyas MJ. Sorption and solubility of luting
TiO2 nanoparticles. Eur J Orthod 2013;35(5):676–9. cements in different solutions. Dent Mater J
[13] Elsaka SE, Hamouda IM, Swain MV. Titanium dioxide 2008;27(5):702–29.
nanoparticles addition to a conventional glass-ionomer [33] Kalachandra S. Influence of fillers on the water sorption of
restorative: influence on physical and antibacterial composites. Dent Mater 1989;5(4):283–8.
properties. J Dent 2011;39(9):589–98. [34] Ferracane JL, Stansbury JW, Burke FJ. Self-adhesive resin
[14] Cheng LC, Jiang X, Wang J, Chen C, Liu RS. Nano-bio effects: cements—chemistry, properties and clinical considerations.
interaction of nanomaterials with cells. Nanoscale J Oral Rehabil 2011;38(4):295–314.
2013;5(9):3547–69. [35] Yiu CKY, King NM, Carrilho MRO, Sauro S, Rueggeberg FA,
[15] Chen X, Mao SS. Titanium dioxide nanomaterials: synthesis, Prati C, et al. Effect of resin hydrophilicity and temperature
properties, modifications, and applications. Chem Rev on water sorption of dental adhesive resins. Biomaterials
2007;107(7):2891–959. 2006;27(9):1695–703.
[16] Roy P, Berger S, Schmuki P. TiO2 nanotubes: synthesis and [36] Tanaka K, Taira M, Shintani H, Wakasa K, Yamaki M.
applications. Angew Chem Int Ed Engl 2011;50(13):2904–39. Residual monomers (TEGDMA and Bis-GMA) of a set
[17] Goto K, Tamura J, Shinzato S, Fujibayashi S, Hashimoto M, visible-light-cured dental composite resin when immersed
Kawashita M, et al. Bioactive bone cements containing in water. J Oral Rehabil 1991;18(4):353–62.
nano-sized titania particles for use as bone substitutes. [37] Monteiro GQM, Souza FB, Pedrosa RF, Sales GCF, Castro
Biomaterials 2005;26(33):6496–505. CMMB, Fraga SN, et al. In vitro biological response to a
[18] Furuse AY, Santana LO, Rizzante FA, Ishikiriama SK, self-adhesive resin cement under different curing strategies.
Bombonatti JF, Correr GM, et al. Delayed light activation J Biomed Mater Res Part B Appl Biomater 2010;92b(2):317–21.
improves color stability of dual-cured resin cements. J [38] Morgan LF, Teixeira KI, Vasconcellos WA, Albuquerque RC,
Prosthodont 2016, http://dx.doi.org/10.1111/jopr.12509. Epub Cortes ME. Correlation between the cytotoxicity of
ahead of print. self-etching resin cements and the degree of conversion.
[19] Soares CJ, Bicalho AA, Verissimo C, Soares P, Tantbirojn D, Indian J Dent Res 2015;26(3):284–8.
Versluis A. Delayed photo-activation effects on mechanical [39] Goncalves F, Boaro LC, Miyazaki CL, Kawano Y, Braga RR.
properties of dual cured resin cements and finite element Influence of polymeric matrix on the physical and chemical
analysis of shrinkage stresses in teeth restored with ceramic properties of experimental composites. Braz Oral Res
inlays. Oper Dent 2016;41(5):491–500. 2015;29:1–7.
[20] Arruda LB, Santos CM, Orlandi MO, Schreiner WH, [40] Ferracane JL, Greener EH. The effect of resin formulation on
Lisboa-Filho PN. Formation and evolution of TiO2 nanotubes the degree of conversion and mechanical properties of
in alkaline synthesis. Ceram Int 2015;41(2):8. dental restorative resins. J Biomed Mater Res
[21] ISO 4049. Dentistry—polymer-based restorative materials. 1986;20(1):121–31.
International Organization for Standardization; 2009. [41] Callister Jr WD, Rethwisch DG. Materials science and
[22] ISO 9917-2. Dentistry—water based cements. International engineering: an introduction. 8th ed. New Jersey, USA: John
Organization for Standardization; 2010. Wiley and Sons; 2009.
[23] ISO 10993-5. Biological evaluation of medical devices. Part 5: [42] Kim KH, Ong JL, Okuno O. The effect of filler loading and
tests for in vitro cytotoxicity. International Organization for morphology on the mechanical properties of contemporary
Standardization; 2009. composites. J Prosthet Dent 2002;87(6):642–9.
[24] Aguiar TR, Di Francescantonio M, Arrais CA, Ambrosano GM, [43] Aguiar TR, Di Francescantonio M, Bedran-Russo AK,
Davanzo C, Giannini M. Influence of curing mode and time Giannini M. Inorganic composition and filler particles
on degree of conversion of one conventional and two morphology of conventional and self-adhesive resin
self-adhesive resin cements. Oper Dent 2010;35(3):295–9. cements by SEM/EDX. Microsc Res Tech 2012;75(10):1348–52.
[25] Di Francescantonio M, Aguiar TR, Arrais CA, Cavalcanti AN, [44] Anusavice KJ. Phillips, materiais dentários. 11th ed. Rio de
Davanzo CU, Giannini M. Influence of viscosity and curing Janeiro: Elsevier Editora Ltda; 2005.
mode on degree of conversion of dual-cured resin cements. [45] Furuichi T, Takamizawa T, Tsujimoto A, Miyazaki M,
Eur J Dent 2013;7(1):81–5. Barkmeier WW, Latta MA. Mechanical properties and
[26] Peutzfeldt A. Resin composites in dentistry: the monomer sliding-impact wear resistance of self-adhesive resin
systems. Eur J Oral Sci 1997;105(2):97–116. cements. Oper Dent 2016;41(3):E83–92.
[27] Rodrigues JA, Fernández-García M. Synthesis, properties, [46] Li ZC, White SN. Mechanical properties of dental luting
and applications of oxide nanomaterials. New Jersey: John cements. J Prosthet Dent 1999;81(5):597–609.
Wiley & Sons, Inc.; 2007. [47] Hofmann N, Papsthart G, Hugo B, Klaiber B. Comparison of
[28] Liu Q, Meng X, Yoshida K, Luo X. Bond degradation behavior photo-activation versus chemical or dual-curing of
of self-adhesive cement and conventional resin cements resin-based luting cements regarding flexural strength,
bonded to silanized ceramic. J Prosthet Dent modulus and surface hardness. J Oral Rehabil
2011;105(3):177–84. 2001;28(11):1022–8.
[29] Malacarne J, Carvalho RM, de Goes MF, Svizero N, Pashley [48] Pegoraro TA, da Silva NR, Carvalho RM. Cements for use in
DH, Tay FR, et al. Water sorption/solubility of dental esthetic dentistry. Dent Clin North Am 2007;51(2):453–71.
adhesive resins. Dent Mater 2006;22(10):973–80.