Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

HH HH

3.5 MPa Hydraulic Cylinder with 3.5 MPa Hydraulic Cylinder with
2 35P-3 Position Detector Position Detector 35P-3 3

Provided with linear Product Lineup


Series Variations Type
Unit: mm

pulse encoder
f32 f40 f50 f63 f80 f100

General purpose type


Standard type
Combination with a computer or an
electronic counter ensures high-accuracy 35P-3
position control and position detection. Double acting
Since a permanent magnet is used for the single rod
length measuring roller for detection of
Switch Set
distance, the length measuring accuracy is
improved. 35P-3R
Resolution : 0.1 mm/pulse
Notes) When using a sensor, use a Switch Set Cylinder.
No sensor can be mounted onto the standard type cylinder.

Standard type Switch Set


Standard Specifications Terminologies

Type Standard type Switch Set


Nominal pressure
Pressure given to a cylinder for
convenience of naming.
It is not always the same as the working
Kind of piston seal U seal Slipper Seal U seal Slipper Seal
pressure (rated pressure) that
guarantees performance under the
Nominal pressure 3.5 MPa specified conditions. 35P-3 35P-3R
Maximum allowable pressure 4.5 MPa Maximum allowable pressure
Maximum allowable pressure generated
Proof test pressure 5 MPa
in a cylinder (surge pressure, etc.). Standard Stroke Range Unit: mm Detector Specifications
Minimum operating pressure 0.2 MPa or less
Proof test pressure Type
Working speed range 8 to 300mm/s 0.1 to 300mm/s 8 to 300mm/s 0.1 to 300mm/s Test pressure against which a cylinder Bore
Standard type Switch Set Standard Semi-standard
can withstand without unreliable
Working temperature range
−10 to +50℃ (no freezing) performance at the return to nominal f32・f40 1000 1000
Power supply
voltage 12 V DC 12 to 24 V DC
(ambient temp. and oil temp.) pressure.
f50・f63 1200 1200 NPN open collector output
Structure of cushioning Metal fitting system Minimum operating pressure 12 V DC voltage output
Phase A & B (90° phase)
1600 1600
Minimum pressure at which cylinder
f80・f100 Output type Phase A & B (90° phase)
Applied voltage : 24 V DC or less
Applicable fluid
Petroleum-based fluid installed horizontally operates under no The above strokes indicate the maximum available strokes
30mA or less
Sink current : 30mA or less
(When using another fluid, refer to the table of fluid adaptability.) load. for the standard type. For the rod buckling, check with the
Notes) buckling chart in the selection materials. Contact us for Resolution 0.1mm/Pulse
The hydraulic pressure
Tolerance for thread JIS 6g/6H longer strokes. Max.
generated in a cylinder due response speed 300mm/s
Tolerance of stroke 0 to 250mm+0.1 251 to 1000mm+1.4 1001 to 1600mm+1.8 to the inertia of load must be
Sensor Mountable Minimum Stroke
Working
0 0 0
Unit: mm −10 to +50℃ (no freezing)
lower than the maximum temperature range
Standard type ……… Carbon steel for machine structural use allowable pressure. Note) Length
0.5mm/m
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


Tube material Item Mounting of 1 sensor Mounting of 2 sensors measuring error
Switch Set ……… Stainless steel For the internal structure,
refer to the sectional Bore AX type SR type AX type SR type Humidity 90%RH (no condensing)
Mounting style LA・LB・FG・FH・CT drawings at the end of this 12V 12V to 24V
catalog. f32

Main circuit

Main circuit
2.2kΩ 100Ω
Boots Standard : Nylon tarpaulin Semi-standard : Chloroprene, Conex Output circuit
Slipper Seal is the registered
Phase A & B
Accessory f40 25 25 diagram Phase A & B
Rod end attachment Rod eye (T-end), rod clevis (Y-end) with pin, floating joint (F-end) trade mark of Nippon Valqua
Industries, Ltd.
GND GND
f50
Conex is the registered 35 35
Metallic receptacle
f63
trademark of Teijin Limited.
Cushion Stroke Length Unit: mm f80 20 20 1 4 (+24V)
Wiring method 1 +12V 3 Phase A
f100 2 3 2 GND 4 Phase B
Cushion stroke
Cylinder bore
(cushion ring length)

f32 to f63 16 Adaptability of Fluid to Seal Material Piston rod advancing direction Piston rod retracting direction
360° 360°
f80 to f100 20 Applicable fluid H H
Seal
35P-3

35P-3
Phase A Phase A
The cushion stroke lengths in case of cylinders used up to material Petroleum- Water- Phosphate Water in Oil in
L L

the stroke end. based fluid glycol fluid ester fluid oil fluid water fluid
Output mode
Phase B
H
Phase B
H

In the case that a cylinder is not used up to the stroke L L


±45° ±45°
end, and it is stopped 5 mm or more before the stroke end, Nitrile rubber ○ ○ × ○ ○ 90° 90°

the cushioning effect will be weakened. In such a case, Phase A advances Phase A delays
consult us. Note) ○ : Applicable × : Inapplicable 90°±45° from phase B. 90°±45° from phase B.

Note) Length measuring error per meter of total moving distance


HH HH
3.5 MPa Hydraulic Cylinder with 3.5 MPa Hydraulic Cylinder with
4 35P-3 Position Detector Position Detector 35P-3 5

● How to order
General Purpose Type The item enclosed by broken line needs not to be entered, if unnecessary. Semi-standard
specification
Sensor List Semi-standard

l❼

t❾
Max. Protective

y
pe

yle

ts
Type Sensor symbol Load voltage range Load current range Indicating lamp Wiring method Cord length Applicable load

en
l

tit
bo
or

ok
ia

in
switching capacity circuit

hm
st

an
Ty

oo
er

m
rb

on

tr

sy
at

qu

ac
g

B
S
de

hi
in

att
1.5m

lm
AF AX101CE

or

or
nt

us
in

ns

ns

nd
a
None

ou

yl
Se

Se

Se
C

de
LED

C
M
AG AX105CE 5m

Ro
DC : 5 to 30V DC : 5 to 40mA (Lights in red 0.3mm², 2-core, outer dia.
Standard type 35P-3 1 LA 40 B 100 − C 0 − T − J AH AX111CE AC : 5 to 120V AC : 5 to 20mA
DC : 1.5W
1.5m
AC : 2VA Provided when sensing) f4mm Rear wiring
AJ AX115CE 5m
Switch Set 35P-3R 1 LA 40 B 100 − AH 2 − T − J

Reed sensor
DC : 30V or less DC : 40mA or less
AE AX125CE AC : 120V or less AC : 20mA or less None None 5m Small relay,
AK AX11ACE AC : 5 to 120V 5 to 20mA 2VA LED 0.5m programmable
Provided (Lights in red 4-pin connector type
AL AX11BCE DC : 5 to 30V 5 to 40mA 1.5W Rear wiring 0.5m controller
when sensing)
1 U seal (nitrile rubber) NJN Nylon tarpaulin LED
0.3mm², 2-core, outer dia.
8 Slipper Seal JN Chloroprene AM AX135CE AC/DC : 90 to 240V 5 to 300mA B contact output Provided (Lights in red
f4mm Rear wiring
5m
when not sensing)
JK Conex
Neon lamp
S SR405 AC : 80 to 220V 2 to 300mA 30VA Provided (Lights when 0.5mm², 2-core, outer 5m
not sensing) dia. f6mm Rear wiring

T T-end (rod eye) BE AX201CE-1 LED 1.5m


Mounting style (Lights in red
Y Y-end (rod clevis) BF AX205CE-1 when sensing) 5m
F F-end (floating joint) CE AX211CE-1 0.3mm², 2-core, outer dia. 1.5m

Solid state sensor


Cylinder bore (mm) CF AX215CE-1 f4mm Rear wiring 5m
f32 to f100 Sensor quantity (1, 2, to n) Small relay,
CT AX211CE-1 1.5m
DC : 5 to 30V 5 to 40mA — Provided LED programmable
CU AX215CE-1 5m
Sensor symbol (two-LED type controller
4-pin connector
Note) Select applicable sensors out of the CV AX21BCE-1 0.5m
B With cushion on both ends in red/green) type Rear wiring
Sensor List. CW AZ211CE-1 1.5m
H With cushion on cap side 0.3mm², 2-core, outer dia.
R With cushion on rod side ●
! Notes on ordering Switch Set CX AZ215CE-1 f4mm Upper wiring 5m

N No cushion When no sensor is required, specify 0 for CY AZ21BCE-1


4-pin connector
type Upper wiring 0.5m
the sensor symbol ❼ and the sensor
quantity ❽. Notes) For the sensors without a protective circuit, be sure to provide a protective circuit (SK-100) with the
Sensors are not mounted on cylinders at load when using any induction load (relay, etc.).
Cylinder stroke (mm)
delivery. The output logic of AX135CE is a B contact. When the piston is detected, the sensor contact turns
off (the lamp turns on).
Standard Stroke Range Sensor Mountable Minimum Stroke For handling of sensors, be sure to see the sensor specifications at the end of this catalog.
Unit: mm Unit: mm
Type Item Mounting of 1 sensor Mounting of 2 sensors Standard type
Standard type Switch Set
Bore Bore AX type SR type AX type SR type AX type sensor SR type sensor
f32・f40 1000 1000 f32
Cord type Connector type
f50・f63 1200 1200 f40 25 25
f80・f100 1600 1600 f50
35 35
The above strokes indicate the maximum available strokes f63
for the standard type. For the rod buckling, check with the
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


20 20
buckling chart in the selection materials. Contact us for
f80
longer strokes. f100

Mounting Style

LA LA style (side lugs) FG FG style (rod flange) CT CT style (cap eye)

LB LB style (end angles) FH FH style (cap flange)


35P-3

35P-3
HH HH
3.5 MPa Hydraulic Cylinder with 3.5 MPa Hydraulic Cylinder with Position Detector
6 35P-3 Position Detector Unit: mm Double Acting Single Rod 35P-3 7

Standard specifications Weight Table Unit: kg


Basic weight Mounting accessory weight Rod end attachment weight
Bore Additional
A Rod clevis Floating
(mm) Standard type, Rod eye weight per
LA style LB style FG style FH style CT style (Y-end) joint mm of stroke
Switch Set (T-end) with pin (F-end)
D B
f32 3.40 0.12 0.19 0.39 0.51 0.12 0.15 0.20 0.19 0.0041
f40 3.72 0.19 0.23 0.40 0.58 0.18 0.16 0.34 0.19 0.0045
C

Both ends cushioned


Semi-standard range f50 5.30 0.28 0.36 0.53 0.86 0.26 0.22 0.35 0.41 0.0078

Port position Ⓐ, cushion valve position Ⓑ Change of detector specifications f63 7.28 0.29 0.46 0.51 1.15 0.40 0.22 0.35 0.41 0.0094

Detector specification supply voltage : 12 V DC (NPN open collector output) f80 11.54 0.66 0.86 1.23 2.27 1.02 0.76 1.01 1.41 0.0122
Output type : 12 V DC, With boots f100 17.03 0.96 1.60 1.47 3.26 1.28 1.30 1.76 2.68 0.0200
AB-phase Change of piston rod end
output (90°phase) Calculation formula : Cylinder weight (kg)=basic weight+mounting accessory weight+additional sensor
Plated cylinder tube
weight+additional weight per mm of stroke×cylinder stroke (mm)
(hard chrome plating thickness 0.02 mm)
Calculation example : Standard type, LB style, bore f63, cylinder stroke 200 mm 7.28+0.46+0.0094×200=9.62kg
Magnetic proximity sensor of SR type
Change of port and cushion valve positions
The standard port position is Ⓐ, and the standard cushion Sensor Additional Weight Unit: kg
valve position is Ⓑ. When modifying the positions, enter End Lock Nut Part Number
the symbol shown in the dimensional drawings. (On the Bore Number Sensor AX type SR type
standard models, the detector is installed on the top.) Bore (mm) Cord length 1.5 m Cord length 5 m With
connector Cord length 1.5 m
f32
(Example) LNA-12F-H f32
f40
35P-3R 1LA40B100− B C AH2−J
f40
f50
Port position (A, B, C, D) LNA-18F-H f50 0.05 0.13 0.04
Cushion valve position (A, B, C, D, or 0)
f63 0.22
f63
f80 LNA-24F-H
In case that the cushion is not equipped, the f80
cushion valve position is“0” . f100 LNA-30F-H
f100 0.07 0.14 0.06

Adaptability of Fluid to Seal Material


Applicable fluid
Seal
material Petroleum- Water- Phosphate Water in Oil in
based fluid glycol fluid ester fluid oil fluid water fluid

○ ○ × ○ ○
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


Nitrile rubber
Note) ○ : Applicable × : Inapplicable
35P-3

35P-3
HH HH
3.5 MPa Hydraulic Cylinder with Position Detector 3.5 MPa Hydraulic Cylinder with Position Detector
8 35P-3 Position Indicator with Multi-point Output Position Indicator with Multi-point Output 35P-3 9

● How to order

PQCPA Series dedicated Position Indicator


Analog input Pulse input
to analog pulse output

s❶

d❷

s❶

d❷


position sensing cylinders

pe

pe
o

o
rie

rie
th

th
Ty

Ty
Se

me

me
Se
ut

ut
Inp

Inp
Environmentally-friendly lead-free indicator PQCPA − CU − A − A PQCPA − CU − P − 12
Analog input and pulse input types are available.
Provided with multi-point output function (5 points) as
a standard function to enable to individually set the A Current input 12 12V open collector input, 12V voltage input
upper and lower limits Note 1)
V Voltage input 24 24V open collector input, 24V voltage input
A 16-bit AD converter is provided to realize high
resolution. (Analog input type) 00 Differential input
Provided with a counter with a response frequency of Note) Cylinders do not come with indicators of 00
200 kHz (Pulse input type) differential input type. (Specification to use the
Provided with a pulse position correcting function Note 2) indicator in stand-alone state)

Note 1) Setting the bank switching enables to use the CN1 connector CN2 connector
multi-output function of up to 15 points. Display (fluorescent display tube) (for input of measuring (for output of measuring
Note 2) Position correction can be made by mounting a sensor signal) sensor signal)
cylinder sensor. Positional error caused by slippage
of the encoder is eliminated.

Standard Specifications
Type Analog Pulse
Model number PQCPA-CU-A PQCPA-CU-P
Applicable input signal Analog voltage/analog current Phase AB
Display ranges ±999999
Status indication lamp block (LED) Operation key block CN3 connector CN4 connector
Resolution Stroke×1/10000 — (for control input/output) (for power supply)
Response frequency 1kHz 200kHz Front face Rear face
Linearity ±0.02%FS —

Voltage input 0 to 10V


Open collector input Dimensional Drawings Supplied connector
Differential input (line driver input)
Signals Voltage input 1 to 5V
Current input 4 to 20mA
12V voltage input CN1 connector
24V voltage input (for input of measuring sensor signal)
Monitor output Voltage output Note) Line driver output CN1 CN2 CN4
Sampling speed 1000times/sec
CN3
Display speed 10times/sec
Panel cutting size
Display method Display by fluorescent display tube
Rear view
Control input No-voltage input (reed sensor/solid state sensor) CN2 connector
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


Open collector Max. rating : 50 V DC, 50mA
(Provided with multi-point output function (5 points) to enable to individually set
120 (for output of measuring sensor signal)
Control output 62
the upper and lower limits and pulse position correcting function)
Power supply voltage 24 V DC ±10% 122
Ambient temperature 0 to 50℃ (no freezing)
Ambient humidity 35 to 85%RH (no condensing)
Note) The monitor output at current input (4 to 20mA) is voltage output of 1 to 5V.
CN3 connector
Function Table List of Applicable Actuators Top view
(for control input/output)
*When fitting the connectors,
Type Analog input Pulse input Series Detection method Signal type 4-φ3.5 keep a space of at least
200 mm at the rear.
PQCPA-CU-A-A PQCPA-CU-P-12 PTN-1B
Model Analog type
number PQCPA-CU-A-V PQCPA-CU-P-24 PTH-1B PQC series control unit PQCPA
Absolute method (4 to 20mA, 0 to 10V)
— PQCPA-CU-P-00 PTT-1B
Display of position Display of position PSR-1A Analog type (1 to 5V) 64 54 60 CN4 connector
HOLD

(for power supply)
POWER ERROR
MODE RST

← →
35P-3

35P-3
Bank switching Bank switching 35P-3
CN5 ↓ HOLD SET

Multi-point output Multi-point output 70P-8 Linear pulse encoder Encoder type
Functions
Positional data hold Positional data hold 140P-8 130 1.5 78.5
140
— 0 setting signal Note) For the details of each cylinder, see the section
Front view Side view
— Correcting function of each series.
HH HH
3.5 MPa Hydraulic Cylinder with Position Detector 3.5 MPa Hydraulic Cylinder with Position Detector
10 35P-3 Position Indicator with Multi-point Output Position Indicator with Multi-point Output 35P-3 11

● How to order
How to order cable between sensor and indicator External Input/Output
CN1 CN3


s❶

r❷

th
de
rie

ng
Description Signals Pin No. Description Signals

lin
Pin No.

Se

cy

le
le
1 Voltage/current input Analog input 1 0 setting signal Input

e
ab

bl
lic

Ca
NC — 2 Positional data hold Input

p
2

Ap
Voltage/current GND Analog input 3 Correcting function Input
PQCPA − CV1 − 01
3
4 Phase A Pulse input 4 Bank switching 0 Input
5 −Phase A Pulse input 5 Bank switching 1 Input
CV1 PTH-1・PTN-1B・PTT-1B 01 1m 6 Phase B Pulse input 6 Bank switching 2 Input
CV2 35P-3・70P-8・140P-8 05 5m 7 −Phase B Pulse input 7 Reserved input Input
+24V Power supply output 8 Reserved input Input
CV3 PSR-1A 10 10m 8
9 +12V Power supply output 9 Input common Input
* When ordering a cable, confirm the series name of the actuator on the sensor side. 10 GND Power supply output/Phase AB GND 10 Input common Input
Some models cannot be connected. 11 Multi-point output signal 0 Output
* After wiring, connect the indicator side connector to the CN1 connector on the indicator. CN2 12 Multi-point output signal 1 Output
Pin No. Description Signals 13 Multi-point output signal 2 Output
PQCPA-CV1- Cable length 1 Pout Analog output 14 Multi-point output signal 3 Output
2 Vss Analog output 15 Multi-point output signal 4 Output
Applicable actuators:PTH-1B/PTN-1B/PTT-1B PQCPA-CU-* A pulse Pulse output 16 Reserved output Output
3
AWG24×2P PQC series control unit PQCPA
4 A pulse GND Pulse output 17 Reserved output Output
POWER ERROR HOLD
↑ MODE RST
5 B pulse Pulse output 18 Reserved output Output
← →
CN5 ↓ HOLD SET 6 B pulse GND Pulse output 19 Output common Output
Cable length (1m, 5m, 10m) 20 Output common Output
CN4 * For details, see the instruction manual.
PQCPA-CV2- Cable length Pin No. Description Signals
1 P24 Power supply
Applicable actuators:35P-3/70P-8/140P-8
PQCPA-CU-* 2 N24 Power supply
AWG24×4C PQC series control unit PQCPA 3 PE Power supply

POWER ERROR HOLD


↑ MODE RST

← →

Example of Product Configuration


CN5 ↓ HOLD SET

Cable length (1m, 5m, 10m)

PQCPA-CV3- Cable length Actuator Cable between sensor and indicator Indicator I/O cable
PQCPA-CU-A-A
Applicable actuators:PSR-1A PQCPA-CU-A-V
2m PQCPA-CU-*
PTH-1B PQCPA-CV1-*
AWG24×2P PQC series control unit PQCPA
PTN-1B
Amplifier PTT-1B
CN1 CN2 CN4


CN3
POWER ERROR HOLD
MODE RST

← →
CN5 ↓ HOLD SET

CN1 connector
PQCPA-IO
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


Cable length (1m, 5m, 10m)

Note) PSR-1A comes with a 2-m cable as a standard accessory. If another cable is required, select
PQCPA-CU-P-12
this cable. (In this case, disconnect the standard cable (2m) of PSR-1A, and connect the selected
PQCPA-CU-P-24
cable directly to the amplifier.)
35P-3 PQCPA-CV2-*
How to order I/O cable
70P-8
CN1 CN2 CN4

140P-8 CN3

PQCPA − IO CN1 connector


External devices
* The I/O cable is 5m long. (programmable External devices
5m controller, etc.) (programmable
PQCPA-CU-*
PQCPA-CU-A-V controller, etc.)
PQC series control unit PQCPA

AWG28 PSR-1A PQCPA-CV3-*


POWER ERROR HOLD
↑ MODE RST
35P-3

35P-3
← →
CN5 ↓ HOLD SET
CN1 CN2 CN4

CN3

Y0, 3-3
CN3 half-pitch connector CN1 connector
Note) Only the CN3 half-pitch connector is supplied as a standard accessory.
If you need the connector with a cable, place an order for the connector.
HH HH
3.5 MPa Hydraulic Cylinder with Position Detector 3.5 MPa Hydraulic Cylinder with Position Detector
12 35P-3 Double Acting Single Rod Unit: mm Unit: mm Double Acting Single Rod 35P-3 13

Dimensional Table
SD Symbol
35P-3 1 SD Bore B Stroke A B B1 BB CS D DD E EE FF
Bore
f 32 24 f 30f9 19 7 6 13 M6×1 □ 44 Rc1/4 15
f 40 24 f 30f9 19 7 6 13 M6×1 □ 50 Rc3/8 15
5 f 50 36 f 34f9 24 7 6 19 M6×1 □ 62 Rc3/8 15
f 63 36 f 34f9 24 9 8 19 M8×1.25 □ 76 Rc3/8 15
D
f 80 48 f 42f9 32 10 10 24 M10×1.25 □ 94 Rc1/2 20
B
f 100 60 f 50f9 41 12 12 30 M12×1.5 □ 114 Rc1/2 20

Symbol
FP GG H HF HK HM HP h J K
Bore
f 32 99 Rc1/8 30 103 22 19 81 7 38 25
WP ZJ+stroke f 40 99 Rc1/8 30 106 25 22 81 7 38 25
0.5□4-core
shielded cable 34 WR WS A W FP P+stroke f 50 99 Rc1/4 30 115 31 31 84 11 38 25
f 63 99 Rc1/4 33 122 38 38 84 11 38 25
2-EE 4-DD
24 f 80 107 Rc1/4 31 134 47 47 87 14 45 32
A h f 100 113 Rc1/4 31 155 57 57 98 17 45 32
HP
HF
D B Symbol
MM KK LF MM P RR W WP WR WS YK ZJ
HK HM Bore
KK
Width across flats f 32 M12×1.25 168 58 □ 33 15 80 55 25 60 183
C B1 of lock nut for rod Cushion valves f16
RR end attachment YK J H+stroke K M12×1.25 □ 37
f 40 168 f16 58 15 80 55 25 60 183
Max. 5 FF LF+stroke
E 3-GG BB
f 50 M18×1.5 168 f22 58 □ 47 15 86 55 31 60 183
drain port CS
f 63 M18×1.5 171 f22 61 □ 56 15 93 55 38 60 186
f 80 M24×2 188 f28 67 □ 70 19 102 55 47 60 207
f 100 M30×2 194 f36 67 □ 89 23 114 57 57 66 217
The tolerance of MM is f8.
There are check valves on two sides out of the four outer sides of the cap and rod covers except Dimension HM indicates the drain port position.
the port and cushion sides. The check valve is concurrently used with air vent.
When mounting a sensor, refer to the“dimensional drawings of Switch Set” . All the contents With Boots
other than“sensor mounting dimensions”are the same. Symbol
WW X
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


Bore
f 32 f 36 50
f 40 f 40 50
f 50 f 45 55
Standard Semi-standard
f 63 f 45 55
WW
Material Nylon tarpaulin Chloroprene Conex f 80 f 60 65
Heat
proof 80℃ 130℃ 200℃ f 100 f 71 65

Notes) When the cylinder is provided with boots,


W the bush is different from that of the
standard type cylinder.
Remember that the heat proof field in the
Nylon tarpaulin f32 to f63 1/3 stroke+X table above shows the allowable tempera-
Chloroprene f80 and f100 1/4 stroke+X
tures for the boots, not for the cylinder.
35P-3

35P-3
Conex f32 to f63 1/2.5 stroke+X Conex is the registered trademark of Teijin
f80 and f100 1/3 stroke+X Limited.
The boots have been mounted at our
factory prior to delivery.
If the calculated value has a fractional part, round it up.
HH HH
3.5 MPa Hydraulic Cylinder with Position Detector 3.5 MPa Hydraulic Cylinder with Position Detector
14 35P-3 Double Acting Single Rod Unit: mm Unit: mm Double Acting Single Rod 35P-3 15

Dimensional Table
LA Symbol
35P-3 1 LA Bore B Stroke A B B1 BB D EE FP GG
Bore
5 f 32 24 f 30f9 19 7 13 Rc1/4 99 Rc1/8
D
f 40 24 f 30f9 19 7 13 Rc3/8 99 Rc1/8
B f 50 36 f 34f9 24 7 19 Rc3/8 99 Rc1/4
f 63 36 f 34f9 24 9 19 Rc3/8 99 Rc1/4
f 80 48 f 42f9 32 10 24 Rc1/2 107 Rc1/4

WP
f 100 60 f 50f9 41 12 30 Rc1/2 113 Rc1/4
ZJ+stroke BB
0.5□4-core
shielded cable 34 WR WS Max. 5 A W FP P+stroke Symbol
HF HK HP h KK MM P SB SS ST
Bore
24 2-EE
f 32 103 22 81 7 M12×1.25 f 16 58 f9 73 8
A h
HP f 40 106 25 81 7 M12×1.25 f 16 58 f 12 73 8
HF
f 50 115 31 84 11 M18×1.5 f 22 58 f 12 73 12
D B
MM
f 63 122 38 84 11 M18×1.5 f 22 61 f 12 76 12
HK
KK
ST f 80 134 47 87 14 M24×2 f 28 67 f 14 82 19
C Width across flats B1
TS of lock nut for rod SY SU Cushion valves SU SY f 100 155 57 98 17 M30×2 f 36 67 f 18 72 24
end attachment
US 4-SB XR SS+stroke
3-GG XW+stroke Symbol
drain port SU SY TS US W WP WR WS XR XW ZJ
Bore
Port position Ⓑ Port position Ⓓ f 32 18 10 69 84 15 80 55 25 100 173 183
f 40 24 10 80 100 15 80 55 25 100 173 183
A A Note) Dimension“a”for port position Ⓑ or Ⓓ.
Bore f 50 24 10 92 112 15 86 55 31 100 173 183
D B a a D B f 32 f 40 f 50 f 63 f 80 f 100 f 63 24 10 108 128 15 93 55 38 100 176 186
Symbol
C C f 80 32 13 128 150 19 102 55 47 112 194 207
a 5 6 6 0 0 0
The same applies to the Switch f 100 27 18 154 182 23 114 57 57 127 199 217
Set Cylinders.
The tolerance of MM is f8.
There are check valves on two sides out of the four outer sides of the cap and rod covers With Boots
except the port and cushion sides. The check valve is concurrently used with air vent. Symbol
When mounting a sensor, refer to the“dimensional drawings of Switch Set” . All the contents WW X
other than“sensor mounting dimensions”are the same. Bore
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


f 32 f 36 50
f 40 f 40 50
f 50 f 45 55
f 63 f 45 55
Standard Semi-standard
f 80 f 60 65
WW
Material Nylon tarpaulin Chloroprene Conex f 100 f 71 65
Heat
proof 80℃ 130℃ 200℃
Notes) When the cylinder is provided with boots,
W the bush is different from that of the
standard type cylinder.
Remember that the heat proof field in the
Nylon tarpaulin f32 to f63 1/3 stroke+X
table above shows the allowable tempera-
Chloroprene f80 and f100 1/4 stroke+X
tures for the boots, not for the cylinder.
35P-3

35P-3
Conex f32 to f63 1/2.5 stroke+X Conex is the registered trademark of Teijin
f80 and f100 1/3 stroke+X Limited.
The boots have been mounted at our
factory prior to delivery.
If the calculated value has a fractional part, round it up.
HH HH
3.5 MPa Hydraulic Cylinder with Position Detector 3.5 MPa Hydraulic Cylinder with Position Detector
16 35P-3 Double Acting Single Rod Unit: mm Unit: mm Double Acting Single Rod 35P-3 17

Dimensional Table
LB Symbol
35P-3 1 LB Bore B Stroke A AB AE AH AL AO AT B B1
Bore
f 32 24 f9 114 33 23 10 5 f 30f9 19
f 40 24 f 12 116 35 25 12 5 f 30f9 19
5
f 50 36 f 12 125 41 26 12 6 f 34f9 24
D
f 63 36 f 12 132 48 28 12 6 f 34f9 24
B
f 80 48 f 14 146 59 34 14 8 f 42f9 32
f 100 60 f 18 168 70 40 18 9 f 50f9 41

Symbol
D EE FP GG HP h KK LF MM
Bore
ZA+stroke f 32 13 Rc1/4 99 Rc1/8 81 7 M12×1.25 168 f 16
WP
XA+stroke f 40 13 Rc3/8 99 Rc1/8 81 7 M12×1.25 168 f 16
0.5□4-core
shielded cable 34 WR WS Max. 5 A W FP P+stroke
f 50 19 Rc3/8 99 Rc1/4 84 11 M18×1.5 168 f 22
2-EE f 63 19 Rc3/8 99 Rc1/4 84 11 M18×1.5 171 f 22
24
f 80 24 Rc1/2 107 Rc1/4 87 14 M24×2 188 f 28
A h
HP f 100 30 Rc1/2 113 Rc1/4 98 17 M30×2 194 f 36
AE
D B
MM Symbol
P R SA UA W WP WR WS XA ZA
AH
KK Bore
AT
Width across flats B1 Cushion valves f 32 58 33 214 54 15 80 55 25 206 216
C of lock nut for rod
R end attachment AL LF+stroke AL
f 40 58 37 218 60 15 80 55 25 208 220
UA 4-AB 3-GG AO SA+stroke AO
drain port f 50 58 47 220 70 15 86 55 31 209 221
f 63 61 56 227 80 15 93 55 38 214 226
f 80 67 70 256 97 19 102 55 47 241 255
f 100 67 89 274 120 23 114 57 57 257 275
The tolerance of MM is f8.
There are check valves on two sides out of the four outer sides of the cap and rod covers except
the port and cushion sides. The check valve is concurrently used with air vent. With Boots
When mounting a sensor, refer to the“dimensional drawings of Switch Set” . All the contents Symbol
other than“sensor mounting dimensions”are the same. WW X
Bore
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


f 32 f 36 50
f 40 f 40 50
f 50 f 45 55
f 63 f 45 55
Standard Semi-standard
f 80 f 60 65
WW
Material Nylon tarpaulin Chloroprene Conex f 100 f 71 65
Heat
proof 80℃ 130℃ 200℃
Notes) When the cylinder is provided with boots,
W
the bush is different from that of the
standard type cylinder.
Remember that the heat proof field in the
Nylon tarpaulin f32 to f63 1/3 stroke+X table above shows the allowable tempera-
Chloroprene f80 and f100 1/4 stroke+X
tures for the boots, not for the cylinder.
35P-3

35P-3
Conex f32 to f63 1/2.5 stroke+X Conex is the registered trademark of Teijin
f80 and f100 1/3 stroke+X Limited.
The boots have been mounted at our
factory prior to delivery.
If the calculated value has a fractional part, round it up.
HH HH
3.5 MPa Hydraulic Cylinder with Position Detector 3.5 MPa Hydraulic Cylinder with Position Detector
18 35P-3 Double Acting Single Rod Unit: mm Unit: mm Double Acting Single Rod 35P-3 19

Dimensional Table
FG Symbol
35P-3 1 FG Bore B Stroke A B B1 BB D EE EF FB FF
Bore
f 32 24 f 30f9 19 7 13 Rc1/4 47 f7 15
f 40 24 f 30f9 19 7 13 Rc3/8 52 f7 15

5 f 50 36 f 34f9 24 7 19 Rc3/8 65 f9 15

D f 63 36 f 34f9 24 9 19 Rc3/8 76 f9 15
f 80 48 f 42f9 32 10 24 Rc1/2 95 f 12 20
B
f 100 60 f 50f9 41 12 30 Rc1/2 115 f 14 20

Symbol
FP GG GP GR HG HH h KK
Bore
f 32 99 Rc1/8 35 65 100 104.5 7 M12×1.25

WP
f 40 99 Rc1/8 35 65 100 107 7 M12×1.25
0.5□4-core f 50 99 Rc1/4 43 67 110 116.5 11 M18×1.5
shielded cable 34 WR WS Max. 5 3-GG A W FP P+stroke
drain port f 63 99 Rc1/4 49 66 115 122 11 M18×1.5
2-EE
f 80 107 Rc1/4 60 68 128 134.5 14 M24×2
24
A h f 100 113 Rc1/4 70 70 140 155.5 17 M30×2

HH Symbol
EF RA D B LF LL MM P RA UG W WP WR WS
B MM
Bore
f 32 168 153 f 16 58 33 114 15 80 55 25
C Cushion valves
KK
4-FB GR GP 5 LL+stroke f 40 168 153 f 16 58 37 114 15 80 55 25
Width across flats B1 of lock
HG FF
nut for rod end attachment LF+stroke BB f 50 168 153 f 22 58 47 128 15 86 55 31
UG f 63 171 156 f 22 61 56 133 15 93 55 38
f 80 188 168 f 28 67 70 152 19 102 55 47
f 100 194 174 f 36 67 84 166 23 114 57 57
The tolerance of MM is f8.
There are check valves on two sides out of the four outer sides of the cap and rod covers except
the port and cushion sides. The check valve is concurrently used with air vent. With Boots
When mounting a sensor, refer to the“dimensional drawings of Switch Set” . All the contents Symbol
other than“sensor mounting dimensions”are the same. WW X
Bore
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


f 32 f 36 50
f 40 f 40 50
f 50 f 45 55
f 63 f 45 55
Standard Semi-standard
f 80 f 60 65
WW
Material Nylon tarpaulin Chloroprene Conex f 100 f 71 65
Heat
proof 80℃ 130℃ 200℃
Notes) When the cylinder is provided with boots,
the bush is different from that of the
W
standard type cylinder.
Remember that the heat proof field in the
Nylon tarpaulin f32 to f63 1/3 stroke+X table above shows the allowable tempera-
Chloroprene f80 and f100 1/4 stroke+X
tures for the boots, not for the cylinder.
35P-3

35P-3
Conex f32 to f63 1/2.5 stroke+X Conex is the registered trademark of Teijin
f80 and f100 1/3 stroke+X Limited.
The boots have been mounted at our
factory prior to delivery.
If the calculated value has a fractional part, round it up.
HH HH
3.5 MPa Hydraulic Cylinder with Position Detector 3.5 MPa Hydraulic Cylinder with Position Detector
20 35P-3 Double Acting Single Rod Unit: mm Unit: mm Double Acting Single Rod 35P-3 21

Dimensional Table
FH Symbol
35P-3 1 FH Bore B Stroke A B B1 D EE EH FB FF
Bore
f 32 24 f 30f9 19 13 Rc1/4 56 f7 15
f 40 24 f 30f9 19 13 Rc3/8 60 f7 15
5 f 50 36 f 34f9 24 19 Rc3/8 70 f9 15

D f 63 36 f 34f9 24 19 Rc3/8 84 f9 15

B f 80 48 f 42f9 32 24 Rc1/2 103 f 12 20


f 100 60 f 50f9 41 30 Rc1/2 125 f 14 20

Symbol
FP GG HE HP HR h KK LF
WP Bore

Max. 5 f 32 99 Rc1/8 109 81 28 7 M12×1.25 168


A W FP P+stroke WS WR 34
f 40 99 Rc1/8 111 81 30 7 M12×1.25 168
2-EE
24 f 50 99 Rc1/4 119 84 35 11 M18×1.5 168
h A f 63 99 Rc1/4 126 84 42 11 M18×1.5 171
HP
HE f 80 107 Rc1/4 138.5 87 51.5 14 M24×2 188
B D RB EH
MM f 100 113 Rc1/4 160.5 98 62.5 17 M30×2 194
HR

KK Cushion valves Symbol


C
Width across flats B1
MM P RB TF UF W WP WR WS ZF
LF+stroke FF TF 4-FB
of lock nut for rod Bore
end attachment ZF+stroke UF f 32 f 16 58 42 64 78 15 80 55 25 198
3-GG
drain port f 40 f 16 58 46 68 82 15 80 55 25 198
f 50 f 22 58 47 86 104 15 86 55 31 198
f 63 f 22 61 56 98 116 15 93 55 38 201
f 80 f 28 67 70 119 143 19 102 55 47 227
f 100 f 36 67 84 140 166 23 114 57 57 237
There are check valves on two sides out of the four outer sides of the cap and rod covers except
the port and cushion sides. The check valve is concurrently used with air vent. The tolerance of MM is f8.
When mounting a sensor, refer to the“dimensional drawings of Switch Set” . All the contents With Boots
other than“sensor mounting dimensions”are the same.
Symbol
WW X
Bore
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


f 32 f 36 50
f 40 f 40 50
f 50 f 45 55
f 63 f 45 55
Standard Semi-standard
f 80 f 60 65
WW
Material Nylon tarpaulin Chloroprene Conex f 100 f 71 65
Heat
proof 80℃ 130℃ 200℃
Notes) When the cylinder is provided with boots,
W
the bush is different from that of the
standard type cylinder.
Remember that the heat proof field in the
Nylon tarpaulin f32 to f63 1/3 stroke+X table above shows the allowable tempera-
Chloroprene f80 and f100 1/4 stroke+X
tures for the boots, not for the cylinder.
35P-3

35P-3
Conex f32 to f63 1/2.5 stroke+X Conex is the registered trademark of Teijin
f80 and f100 1/3 stroke+X Limited.
The boots have been mounted at our
factory prior to delivery.
If the calculated value has a fractional part, round it up.
HH HH
3.5 MPa Hydraulic Cylinder with Position Detector 3.5 MPa Hydraulic Cylinder with Position Detector
22 35P-3 Double Acting Single Rod Unit: mm Unit: mm Double Acting Single Rod 35P-3 23

Dimensional Table
CT D
5

Symbol
35P-3 1 CT Bore B Stroke A B B1 CD D E EE
B Bore
f32 to f80 f 32 24 f 30f9 19 f 12H9 13 □ 44 Rc1/4
WP
f 40 24 f 30f9 19 f 14H9 13 □ 50 Rc3/8
A W FP P+stroke Max. 5 WS WR 34
f 50 36 f 34f9 24 f 14H9 19 □ 62 Rc3/8
2-EE f 63 36 f 34f9 24 f 14H9 19 □ 76 Rc3/8
LR 24
f 80 48 f 42f9 32 f 20H9 24 □ 94 Rc1/2
h CD A
HP f 100 60 f 50f9 41 f 25H9 30 □ 114 Rc1/2
HF
B D
MM Symbol
MR HK EW FP GG HF HK HP h KK
Bore
KK Cushion valves
C 0
Width across flats B1 LF+stroke L EW f 32 16−0.07 99 Rc1/8 103 22 81 7 M12×1.25
of lock nut for rod 0
end attachment XC+stroke E f 40 20−0.084 99 Rc1/8 106 25 81 7 M12×1.25
3-GG ZC+stroke f 50 0
20−0.084 99 Rc1/4 115 31 84 11 M18×1.5
drain port
WP f 63 0
20−0.084 99 Rc1/4 122 38 84 11 M18×1.5
f100
Max. 5 WS WR 34
0
A W FP P+stroke f 80 32−0.1 107 Rc1/4 134 47 87 14 M24×2
0
f 100 40−0.1 113 Rc1/4 155 57 98 17 M30×2
2-EE LR
24
h CD A Symbol
HP L LF LR MM MR P W WP WR WS XC ZC
Bore
HF
MM B D f 32 19 168 R12 f16 R14 58 15 80 55 25 202 216
HK f 40 19 168 R17 f16 R16 58 15 80 55 25 202 216
KK MR f 50 19 168 R19 f22 R16 58 15 86 55 31 202 216
Cushion valves C
Width across flats B1 LF+stroke L EW f 63 19 171 R19 f22 R16 61 15 93 55 38 205 219
of lock nut for rod
end attachment XC+stroke E
f 80 32 188 R26 f28 R22 67 19 102 55 47 239 259
3-GG ZC+stroke
drain port f 100 53 194 R32 f36 R30 67 23 114 57 57 270 295
The tolerance of MM is f8.
There are check valves on two sides out of the four outer sides of the cap and rod covers except
the port and cushion sides. The check valve is concurrently used with air vent.
With Boots
When mounting a sensor, refer to the“dimensional drawings of Switch Set” . All the contents Symbol
other than“sensor mounting dimensions”are the same. WW X
Bore
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


f 32 f 36 50
f 40 f 40 50
f 50 f 45 55
f 63 f 45 55
Standard Semi-standard
f 80 f 60 65
WW
Material Nylon tarpaulin Chloroprene Conex f 100 f 71 65
Heat
proof 80℃ 130℃ 200℃
Notes) When the cylinder is provided with boots,
W the bush is different from that of the
standard type cylinder.
Remember that the heat proof field in the
Nylon tarpaulin f32 to f63 1/3 stroke+X table above shows the allowable tempera-
Chloroprene f80 and f100 1/4 stroke+X
tures for the boots, not for the cylinder.
35P-3

35P-3
Conex f32 to f63 1/2.5 stroke+X Conex is the registered trademark of Teijin
f80 and f100 1/3 stroke+X Limited.
The boots have been mounted at our
factory prior to delivery.
If the calculated value has a fractional part, round it up.
HH HH
3.5 MPa Hydraulic Cylinder with Position Detector 3.5 MPa Hydraulic Cylinder with Position Detector
24 35P-3 Double Acting Single Rod Unit: mm Unit: mm Double Acting Single Rod 35P-3 25

Switch Set Dimensional Table


Symbol RN RV RY UX
35P-3R 1 Mounting style Bore B Stroke − Sensor symbol Sensor quantity
Bore AX type SR type AX type SR type AX type SR type AX type SR type
f 32 7 5 34 37 68 74 5 2

AX1**
(reed sensor)・AX2**
(solid state sensor)
f 40 5 4 36 40 72 80 5 2
f 50 4 4 41 45 82 90 5 2
f 63 3 4 47 51 94 102 6 3
UX 30 7 Sensor UX
f 80 3 3 54 59 108 118 4 2
f 100 4 1 63 68 126 136 4 2
RN
Note) Dimension UX indicates the optimum sensor mounting position for detection of stroke end.

Operating Range and Hysteresis


RV RV Symbol Reed sensor Solid state sensor

RY AX1** SR type AX2**


Bore Operating range Hysteresis Operating range Hysteresis Operating range Hysteresis
f 32

SR type (reed sensor) f 40 3 to 6 7 to 10 5 to 10


f 50
1 or less 3 or less 1 or less
f 63
UX 40 4 Sensor UX 3 to 7 7 to 11
f 80 9 to 12
RN f 100 4 to 7 8 to 12

RV RV

RY

All dimensions of the cylinders are the same as those of the standard type.
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


35P-3

35P-3
HH HH
3.5 MPa Hydraulic Cylinder with 3.5 MPa Hydraulic Cylinder with
26 35P-3 Position Detector Unit: mm Unit: mm Position Detector 35P-3 27

Rod End Attachment Dimensional Table/Rod eye (T-end)


Symbol
Rod eye (T-end) Part number A CA CC CD CF D ER EW KK RA
CC A Bore
0
f 32 RTA-12-1-H 25 55 20 f12H9 f24 24 R12 16 −0.07 M12×1.25 67
0
f 40 RTA-12-H 25 60 20 f14H9 f24 24 R12 20 −0.1 M12×1.25 72
EW D Width across flats
f 50
0
RTA-18-H 37 64 18 f14H9 f28 30 R14 20 −0.1 M18×1.5 78
KK f 63
0
f 80 RTA-24-H 49 100 30 f20H9 f38 41 R19 32 −0.1 M24×2 119
0
f 100 RTA-30-H 61 110 37 f25H9 f48 50 R24 40 −0.1 M30×2 134
ER RA

CF

CD
CA

Dimensional Table/Rod clevis (Y-end) with pin


Rod clevis (Y-end) with pin Symbol
Part number A CA CC CD CF CP CT CW D ER EW KK RA
Bore
CC A f 32 RYA-12-2-H 25 55 20 f12H H9
f8 f24 46 32 8 24 R12 16 +1.5
+0.5 M12×1.25 67
f 40 RYA-12-1-H 25 60 20 f14H
H9
f8
f24 58 44 12 24 R12 20 +1.5
+0.5 M12×1.25 72
CW
f 50
20 +1.5
H9
CP CT EW CF RYA-18-H 37 64 18 f14H f8 f28 58 44 12 30 R14 +0.5 M18×1.5 78
f 63
CW
f 80 RYA-24-H 49 100 28 f20H
H9
f8
f38 78 64 16 41 R19 32 +1.5
+0.5 M24×2 119
f 100 RYA-30-H 61 110 35 f25H H9
f8
f48 94 80 20 50 R24 40 +1.5
+0.5 M30×2 134

ER RA

D Width across flats

CD CA KK
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


Dimensional Table/Floating joint (F-end)
Floating joint (F-end) Symbol
Part number A B1 B2 e FA FC FD FJ FK FM FN FQ FR h KK
Bore
Width across flats B2 FK
f 32
Lock nut width RFH-12 24 19 13 1 33 36.5 11 69.5 13.5 f32 19 7 20.5 7 M12×1.25
across flats B1 f 40
KK
f 50
Rotating angle Notes) The insertion of the floating joint into RFH-18 35 24 19 1.5 46 46 13 92 16 f40 24 8 31 11 M18×1.5
e the socket shall not equal or exceed the
f 63

Eccentricity FM dimension of screw diameter. (Return
e 5° f 80 RFH-24-2 46 32 24 2.5 62 67 18 129 24 f64 36 12 41 14 M24×2
the joint one or two turns after it gets
into contact with the socket bottom, f 100 RFH-30-2 58 41 32 2.5 78 83 21 161 30 f76 46 14 52 17 M30×2
h and fix it with a lock nut.)
Excessive insertion can cause operation
35P-3

35P-3
KK FR
failure.
A FD FN DO NOT use together with CT
accessory.
FQ
FA FC The lock nut is indispensable in using
the floating joint. Please don't miss to
FJ order the lock nut with the floating joint.
HH HH
3.5 MPa Hydraulic Cylinder with 3.5 MPa Hydraulic Cylinder with
28 35P-3 Position Detector Unit: mm Unit: mm Position Detector 35P-3 29

Parallel Pin Dimensional Table


f32 to f100
Symbol
Nominal of
BL CK EB EL
Bore split pin

f 32 46 f12 f3 37 3
2-EB
f 40 58 f14 f3 49 3
f 50 58 f14 f3 49 3
CK
f 63 58 f14 f3 49 3
f 80 78 f20 f3 71 3
EL
f 100 94 f25 f3 87 3
BL
The tolerance of CK is f8.
Hydraulic Cylinders with Position Detector

Hydraulic Cylinders with Position Detector


35P-3

35P-3

You might also like