Professional Documents
Culture Documents
H0FL-11000P、11000N User's Manual V1.7
H0FL-11000P、11000N User's Manual V1.7
H0FL-11000P、11000N User's Manual V1.7
User‟s Manual
E - m a i l : support@huahuan.com
Contents
1. OVERVIEW ........................................................................... 1
7. TROUBLESHOOTING ........................................................ 48
1. Overview
H0FL-11000P/H0FL-11000N is a gigabit media converter produced by
Beijing Huahuan Electronics Co., Ltd, realizing optical-electrical medium transfer
of gigabit Ethernet. H0FL-11000P is a dual fiber port 1:1 protective
10/100/1000M adaptive Ethernet manageable gigabit media converter; H0FL-
11000N is an ordinary 10/100/1000M adaptive Ethernet manageable gigabit
media converter. H0FL-11000P/H0FL-11000N gigabit media converter supports
IEEE 802.3ah OAM management, supporting Active, Passive, and Auto operation
modes when working with local terminal H0FL-P.V2 with card 11000P/11000N.
It locally supports Web Server NMS, MSDH NMS, and setting and query
functions of local network element through Console port command line.
Supports IEEE 802.1q VLAN and IEEE 802.1ad VLAN, and at most 15
VLAN entries are supported;
Supports IEEE 802.3ah OAM function, and supports Active, Passive and
Auto operation modes;
Note: Only the embedded software V3.1 cannot support online upgrade
function.
Functional
Products types Description
distinction
2. Typical Application
Gigabit Ethernet media converter H0FL-11000P/H0FL-11000N can form
basic transmission structure of point to point, and also can be connected to CO
equipment H0FL-P.V2 with corresponding card to realize point to multipoint
application. Typical application diagrams are shown in Figure 2-1 and Figure 2-2.
Remote side
H0FL - 11000P 10/100/ 1000 Base -Tx
H0FL - 1101S2
10/100Base -Tx
H0FL - H01100
10/100Base -Tx
E1
H0 FL - 04100
NMS 10 /100 Base -Tx
4 × E1
1000Base-Fx 1 H0FL - 08100
N × 10/100Base - Fx
8×E 10/100Base -Tx
The Active mode can initiate query and configuration frame, e.g. OAM
discovery, OAM loopback, and remote Dying Gasp according to 802.3ah protocol.
It can also extend custom OAM remote management, to realize management of
remote equipment; The Passive mode cannot initiate query and configuration
frame, but it can perform passive response, e.g. OAM discovery, MIB variable
response, OAM loopback, and Dying Gasp; Auto mode is adaptive mode of
Active and Passive; When OAM is disabled, the product will neither initiate
OAM frame, nor respond to it.
IEEE 802.1q VLAN and IEEE 802.1ad VLAN Functions: Set Through
NMS
When VLAN is disabled, the electrical port and optical port of equipment
will become switching ports.
Note: When the optical port is in force 100M full-duplex mode, flow
control will not be supported.
H0FL- 11000P
GE CONSOLE
85-265VAC/36-72VDC PRI SEC
OAM L/A L/A
GE CONSOLE
AC 220V PRI SEC
OAM L/A L/A
DC 48V
GE CONSOLE
I + OAM L/A PRI L/A
SEC
0
- SYS L/A SPD OLOS OLOS
100/1000M LX
DC 24V
GE CONSOLE
I + OAM L/A PRI L/A
SEC
0
- SYS L/A SPD OLOS OLOS
100/1000M LX
H0FL- 11000N
85-265VAC/36-72VDC
H0FL-11000N L/A SPD
OAM L/A
0 1
- SYS GE OLOS 100/1000M LX CONSOLE
0 1
- SYS GE OLOS 100/1000M LX CONSOLE
The LED functional descriptions of the rear panel are shown in Table 3-1.
Table 3-1 H0FL-11000P/H0FL-11000N LED functional descriptions
1
8
Pin 1 2 3 4 5 6 7 8
Definition tip ring tip ring tip ring tip ring
Line pair paired paired paired paired paired
with 6 with 3
Tip:
1. 10Base-T and 100Base-T only require 2 pairs of lines, i.e. pin 1 and 2
(sending signals), pin 3 and 6 (receiving signals); but 1000Base-T
standard requires 4 pairs of lines, i.e. all the 8 lines, and 5e or 6
twisted line must be used, and RJ-45 plug must possess high quality
and operation must be standard, or the path will be blocked or
H0FL-11000P/H0FL-11000N Gigabit Media Converter User‟s Manual V1.7 13
Beijing Huahuan Electronics Co., Ltd
unstable.
2. The Ethernet electrical port of H0FL-11000P/H0FL-11000N can
automatically detect the transceiver line order and perform adaptions,
so Ethernet interfaces MDI and MDI-X, and cross and parallel lines
can be used.
3. Local Web Server management can be performed after Ethernet
electrical port is connected to switch.
4. Ethernet electrical port can be directly connected to PC machine, to
run MSDH NMS.
When the plug is inserted into media converter module, the locating pin on
the plug should be put into the corresponding locating notch on the socket and
make sure the pin is in place. Pay attention to the sending and receiving
correspondence with the remote equipment. The bending radius of pigtail should
not be less than 50mm. When plugging or unplugging optical fiber connector,
please do not directly pull the optical fiber. The protection plug on the optical port
seat should be preserved. When no optical fiber is plugged, the protection plug
must be inserted to prevent dust from entering.
Note: When dual optical protection mode is used, the Ethernet optical
Console Port:
Pin 1 2 3 4 5 6 7 8
Definition - - TXD GND GND RXD - -
Console port is RS232 serial port. The protocol used is: Baud rate: 57600 bps,
data bit: 8, parity bit: none, stop bit: 1, data stream control: none.
The equipment‟s power supply input port is on the left side of the rear panel.
The supply types include +24V DC, -48V DC, ~220V AC, -48V DC or ~220V
AC. When +24V DC or -48V DC is used, the equipment is provided with DC
window-shaped socket. When ~220V AC, -48V DC or ~220V AC is used, the
equipment is provided with ~220V standard AC socket. The User can select
power supply type according to their needs. For detailed description of power
supply connection, see 5.5 Power Cable Connection.
1. For DC-Only version, use the color-coded wires on the open end of the
power cord for power connection. Red is for high potential, i.e. GND for -
48V (or +24V); Blue is for low potential, i.e. -48V (or GND for +24V).
When inserting power plug, pay attention to direction of locking lever.
The electrode on the bottom left of DC socket is protection ground
connected to the yellow-green wire.
2. For Unified-AC/DC version, only an AC power cord is supplied, which
should be used directly for AC power supply. In case of DC power supply,
cut off the wall plug on the cord, connect the brown wire to high potential,
i.e. GND for -48V; connect the light blue wire to low potential, i.e. -48V;
connect yellow-green wire to protection ground.
3. For user’s safety, please make sure the protection ground is connected
well when installing the device.
1 2 3 4 5 6 7 8 9 10
H/S
K1 OAM LFP PORT GE PORT LX
SEL
KEY 1 2、3 4 5 6 7 8
↑/↓ PASSIVE
↓/↑ ACTIVE
↓ H/W EN MAN 10M MAN 100M
↓/↓ DIS
manual mode of
Ethernet electrical
port (Dip 1: ↓ and
Dip 5: ↓)
Ethernet optical port
Needs effective
operation mode:
7 Dip setting (Dip ↑
↑: auto negotiation mode
1: ↓)
↓: manual mode
Tip:
2. When the dips are set to software effective, remote monitoring can be
realized through local equipment H0FL-P.V2 with corresponding card
11000P/11000N.
4. Cable Introductions
4.1 RS232-RJ45 Interface Adapter Cable (BH4.851.105A)
Application
RS232-RJ45 interface adapter cable is used to connect Console port of
device with RS-232 serial port of PC machine, transfer device configuration data
signal and implement local debugging and maintenance of equipment. Connectors
on both ends of the cable are as below:
Appearance
Appearance diagram of RS232-RJ45 interface adapter cable is shown in
Figure 4-1.
Cable Connection
Pin number is shown in Figure 4-2, cable connection is shown in Table 4-1.
PIN5 PIN1
PIN8
PIN9 PIN6 PIN1
RS-232(DB9-F) RJ45
RS-232
RJ-45 Signal Color Twisted pair
(DB9-F)
1 - - - -
4 GND Blue
5 Twisted pair 3
5 GND Blue white
9 - - - -
Technical Parameters
Technical parameters of RS232-RJ45 interface adapter cable is shown in
Table 4-2.
Item Description
Item Description
4.2 Fiber
Application
Fiber is used to connect optical port with uplink device.
Appearance
Appearance diagram of LC/PC fiber connector is shown in Figure 4-3.
When plugging fiber: align the head of the fiber jumper with the optical
interface and insert the optical fiber into the interface with moderate force.
When removing the fiber: press the latch on the connector and push the
fiber head inwards, and then pull the fiber out.
Appearance
Appearance diagram of Ethernet cable is shown in Figure 4-4.
Connector 1 Connector 2
Cable Connection
Ethernet cables are classified into straight through cable and crossover cable:
Straight through cable: the line orders of twisted pair crimped by both
ends RJ45 connectors are EIA/TIA 568B standard line orders.
Crossover cable: the line order of twisted pair crimped by one end RJ45
connector is EIA/TIA 568A standard line order, the line order of the other
end is EIA/TIA 568B standard line order.
Line orders of EIA/TIA 568A and EIA/TIA 568B standards are shown in
Table 4-3.
Table 4-3 Line orders of EIA/TIA 568A and EIA/TIA 568B standards
Both two RJ45 connectors of the straight through cable follow EIA/TIA568B
standard line order. Diagram of cable connection is shown in Figure 4-5.
The line order of the 100 Mbit/s crossover cable is different from that of the
1000 Mbit/s crossover cable. Diagrams of cable connection are shown in Figure
4-6 and Figure 4-7.
H0FL-11000P/H0FL-11000N Gigabit Media Converter User‟s Manual V1.7 23
Beijing Huahuan Electronics Co., Ltd
Tip: 1000Mbit/s crossover cable uses all 8 pins. On the both sides of cable,
the crossover is PIN1 to PIN3, PIN2 to PIN6, PIN4 to PIN7, and PIN5 to PIN8.
Technical Parameters
Technical parameters of Ethernet cable are shown in Table 4-4.
Table 4-4 Technical parameters of Ethernet cable
Item Description
Quantity of cores 8
Appearance
AC power supply cable of H0FL-11000P/H0FL-11000N depends on local
standards, while different regions have different standards, as shown in Table 4-5.
Table 4-5 The corresponding table of AC power cable used in different regions
Technical Parameters
Table 4-6 lists technical parameters of AC power cable.
Item Description
Color Black
Length 1.5m
Appearance
DC power cable is composed of 2X2 socket and power cable, as shown in
Figure 4-14.
-48V -48VGND
1m
CGND
3
-48V GND
1
2
-48V
2m
Cable Connection
Table 4-7 lists -48V DC power cable connection relations.
2 Yellow-green CGND
3 Red -48V GND
4 - -
1 2 3 4
Number Name
1 Wire
3 Insulating sheath
4 OT terminal
Technical Parameters
Table 4-9 lists technical parameters of the protection ground cable.
Item Description
Length 0.4m
Connector OT/OT
CONSOL
E
Step2 Insert DB9-F connector of RS232-RJ45 port adapter cable into RS-
232 serial port of NM PC.
Tx Rx
Step2 Respectively remove the dust caps on the optical module and the fiber,
aim the head of the fiber at the optical module port and insert it into
the port with moderate force.
Note:
Step2 Aim RJ45 connector on one end of Ethernet cable at the device‟s
Ethernet port; insert it into the port with moderate force, as shown in
Figure 5-5.
Step3 Aim RJ45 connector on the other end of Ethernet cable at the device‟s
Ethernet port; insert it into the port with moderate force.
AC 220V
85-265VAC/36-72VDC
L /+ PG N /-
Step3 When using -48V (or +24V) DC power supply. Aim 2×2 connector of
DC power cable at the 2×2 socket of device, and then insert it into the
socket with moderate force, as shown in Figure 5-8.
1
0
-
5.6 Power on
About 4 seconds after powering on the device, if equipment operation
indicator light SYS keeps flashing, equipment operation will be normal. If L/A
light at Ethernet socket is on, the Ethernet port will be connected correctly.
Through Ethernet port, Web server management, MSDH NMS and local network
element setting by command line of Console port can be performed. The Ethernet
operation mode and functions supported of equipment of two ends should be set
consistently. When packets are pinged by devices on two ends, L/A light should
keep flashing.
6. Equipment Monitoring
Gigabit Ethernet media converter H0FL-11000P/H0FL-11000N supports
Console port command line management, Web Server management, and EzView
NMS concentrated management.
Step2 Type in a name beneath “Name”, e.g. “1”, as shown in Figure 6-2.
Step3 Click OK, Connect To dialog will pop out. Select COM1 in the drop-
down list box on the right side of “Connect using”, as shown in Figure
6-3.
Step4 Click OK, the Port Settings dialog will pop out, as shown in Figure
6-4. The parameters are set as follows:
Step5 Click OK, entering hyper terminal interface. Press ENTER to enter
command line, and type in user name and password, both of which are
“admin” by default, as shown in Figure 6-5.
help
Example:
get_info
Example:
ip_nm
Example:
# ip_nm
set_addr
Set equipment‟s IP address. Note that only when IP is enabled, may IP,
MASK and GATEWAY addresses be set, or “IP is disable, you can not
set IP, MASK and GATEWAY!” will be prompted.
42 H0FL-11000P/H0FL-11000N Gigabit Media Converter User‟s Manual V1.7
Beijing Huahuan Electronics Co., Ltd
Example:
# set_addr
#192.192.4.6
#255.255.0.0
#192.192.4.100
#y
Config successfully !
disvlan
VLAN is disabled.
Example:
#disvlan
H0FL-11000P/H0FL-11000N Gigabit Media Converter User‟s Manual V1.7 43
Beijing Huahuan Electronics Co., Ltd
#get_snmp_info
set_snmp_com -r
Used for setting SNMP read community. First show current read
community, and then prompt the new read community to be typed in.
Example:
#set_snmp_com –r
#hello
set_snmp_com –w
Used for setting SNMP write community. First show current write
community, and then prompt new write community to be typed in.
Example:
#set_snmp_com -w
#good
reboot
Reboot.
Example:
#reboot
restore
Example:
# restore
set_uartpwd
Example:
#set_uartpwd
*****
****
****
User logout.
set_webpwd
Example:
#set_webpwd
****
****
****
oam_relb
Used for setting OAM remote loopback. When oam_relb is typed in,
command formats and parameters will be prompted.
Example:
# oam_relb
Before oam_relb –e is typed in, ensure that local OAM mode is Active,
remote OAM mode is Active or Passive, and OAM indicator light is on,
or “# OAM is passive, you can not set remote loopback” or “OAM state
is not SEND_ANY, you can not set remote loopback” will be prompted.
exit
Log out.
Example:
#exit
User logout.
7. Troubleshooting
When failure occurs, first locate the alarm position through indicator lights
on the panel. Find out whether it is equipment failure or transmission line failure
and then deal with the failure accordingly. Common failures and solutions are as
follows.
Table 7-1 Common failures and solutions
If problems occur during installation and usage, please try to solve them by
the recommended solutions above. If problems persist, please contact Beijing
Huahuan Electronics, Co., Ltd. for technical support.
8. Technical Specifications
10/100/1000Base-GE Interface:
100/1000Base-LX Interface:
H0FL-11000N: ≤ 3W
H0FL-11000N: ≤0.7kg
9.1 Terms
Term Explanation
S
H0FL-11000P/H0FL-11000N Gigabit Media Converter User‟s Manual V1.7 53
Beijing Huahuan Electronics Co., Ltd
Single Mode Fiber Only a single mode can be transmitted in one fiber.
9.2 Abbreviations
Abbreviations Explanation
AC Alternating Current
DC Direct Current
GE Gigabit Ethernet
IP Internet Protocol
RH Relative Humidity