X1 X2 X3 X4 X5 X6 X1 X2 X3 X4 X5 X6

3100 4200 4200 5600 3814 3100 4200 4200 5600 3814

SUNKEN FOR FUTURE


EXTENSION
B1* - 3.80m SSL
PB2 PB2 PB2 PB2 PB2 B1* B2 B2 B1* B2
Y1 Y1

-
SK1
4000

4000
B3 B3
PB1 PB1 PB1 PB1 PB1 PB1 B1* B3 B1 B1
SK1 S1 S1 S1
PB1 B3
Y2 Y2
1600

1600
B2
Y3 Y3
PB2 PB2 PB2 PB2 PB2 B1* B2 B2 B2
4500
5300

5300

4000
B1
PB2 PB2 B2 B2
S1

PB1 B1
Y4 Y4
4500

S1
5050

5050

4000
PB2 PB2 B2 B2

B1
PB1 B1
Y5 Y5

PLINTH BEAM FRAMING LAYOUT GF ROOF FRAMING LAYOUT


1 SCALE 1:100
1 SCALE 1:100

X4

SCHEDULE OF TIE BEAM & ROOF FLOOR BEAMS MRA


.LS
IAD
I ALA
ILMANDHARI
REINFORCEMENT
BEAM SECTION BOTTOM TOP STIRRUPS REMARKS
NO. (BXD)
(mm) AL THROUGH CURTAILED AL THROUGH CURTAILED
PB1 200 x 500 2-T16Ø - 2-T16Ø - T8 @ 150mm C/C

PB2 200 x 500 2-T16Ø 1-T16Ø 2-T16Ø 1-T16Ø T8 @ 150mm C/C

B1 200 x 500 3-T16Ø - 3-T16Ø - T8 @ 150mm C/C

B2 200 x 500 2-T16Ø 2-T16Ø 2-T16Ø 2-T16Ø T8 @ 150mm C/C

B3 200 x 650 2-T16Ø 2-T16Ø 2-T16Ø 2-T16Ø T8 @ 150mm C/C

SECTION-3

SECTION-1

SLAB REINFORCEMENT

Fcu = 40 N/mm²
Fy = 460 N/mm²
SCHEDULE OF EXTRA REINFORCEMENT

MARK REINFORCEMENT LENGTH REMARK


NOTE:

SECTION-2