CASE

N-205
CASES OF ASME BOILER AND PRESSURE VESSEL CODE

Approval Date: July 13, 1981


See Numeric Index for expiration
and any reaffirmation dates.

Case N-205 (3) The design shall be in accordance with the


Use of Ductile Iron SA-395, Class 3 requirements of Section III, Division 1, of Subsection
Section III, Division 1 ND. The allowable stress shall not exceed 12,000
Inquiry: Is it permissible in the construction of Class psi. Slip joints with elastomeric gaskets are permitted.
3 pipe and fittings for service water, conforming to Caulked joints and welded joints are prohibited.
the requirements of Section III, Division 1, to use (4) Repair by plugging, peening, welding, impreg-
ductile iron conforming to SA-395 and the additional nation, or stitching is not permitted. Repair by grinding
requirements listed below? is permitted in accordance with ND-2578.
(5) Each pipe and fitting shall be subjected to
Reply: It is the opinion of the Committee that the
material specified in the Inquiry may be used in the hydrostatic test of not less than 500 psi for not less
construction of Class 3 piping systems for service water than 5 min. No leaks are permitted.
under the rules of Section III, Division 1 of the Code (6) The Material Manufacturer shall have a Quality
provided the following additional requirements are met: Assurance Program in accordance with NCA-3800 of
(1) Service shall be confined to water or salt water. Section III, Division 1.
(2) Design Pressure shall not exceed 150 psi, and (7) The material shall be identified by this Case
Design Temperature shall not exceed 200°F. number by the Material Manufacturer.

319

COPYRIGHT American Society of Mechanical Engineers