CASE

N-647
CASES OF ASME BOILER AND PRESSURE VESSEL CODE

Approval Date: December 8, 2000


See Numeric Index for expiration
and any reaffirmation dates.

Case N-647 side requiring augmented examination shall be examined


Alternative to Augmented Examination for wall thinning using an ultrasonic thickness measure-
Requirements of IWE-2500 ment method in accordance with Section V, T-544.
Section XI, Division 1 (1) When ultrasonic thickness measurements are
performed, grids not exceeding one foot square shall
Inquiry: What alternative to the requirements of be used. The number and location of the grids shall
IWE-2500 may be used for augmented examination of be determined by the Owner.
Class MC components and metallic liners of Class CC
(2) Ultrasonic thickness measurements shall be
components?
used to determine the minimum wall thickness within
each grid. The location of the minimum wall thickness
Reply: It is the opinion of the Committee that the
within each grid shall be marked or recorded such that
following may be used as an alternative to the require-
periodic reexamination can be performed in accordance
ments of IWE-2500(c) (1989 Edition through the 1995
with the requirements of Table IWE-2500-1, Examina-
Edition with the 1997 Addenda) or IWE-2500(b) and
tion Category E-C (1989 Edition through the 1995
Table IWE-2500-1, Examination Category E-C (1998
Edition through the 1998 Edition with the 2000 Ad- Edition with the 1997 Addenda) or Table 1, Examination
denda). Category E-C (1998 Edition through the 1998 Edition
Augmented examination of surface areas identified with the 2000 Addenda). A sampling plan may be used
in IWE-1242 shall comply with the following criteria: to determine the number and location of ultrasonic
(a) Surface areas requiring augmented examination thickness measurement grids within each contiguous
that are accessible for visual examination shall be examination area, provided
examined using a VT-1 (1989 Edition through the 1995 (a) acceptance of the examination area is based
Edition with the 1997 Addenda) or a detailed (1998 on a statistical confidence level of at least 95% that
Edition with the 2000 Addenda) visual examination 95% of all grids within the examination area meet the
method. acceptance standards of IWE-3500;
(b) Surface areas requiring augmented examination (b) grid locations are selected at random from
that are not accessible for visual examination of the within each examination area.

1131

COPYRIGHT American Society of Mechanical Engineers


Licensed by Information Handling Services
N-647

TABLE 1
CASE (continued)

EXAMINATION CATEGORIES
EXAMINATION CATEGORY E-C, CONTAINMENT SURFACES REQUIRING AUGMENTED EXAMINATION

Extent and Frequency of Examination

Licensed by Information Handling Services


Examination 1st Successive Deferral of
Item Parts Requirements/ Examination Acceptance Inspection Inspection Inspection to
No. Examined Fig. No. Method Standard Interval Interval End of Interval

E4.10 Containment Surface Areas

COPYRIGHT American Society of Mechanical Engineers


[Note (1)]

E4.11 Visible Surfaces IWE-2310(c) Detailed Visual IWE-3511 100% of surface 100% of surface Not Permissible
Reply (a) areas identified areas identified
by IWE-1242 by IWE-1242
[Note (1)] [Note (2)]

1132
E4.12 Surface Area Grid Reply (b) Ultrasonic Thickness IWE-3511 100% of minimum 100% of minimum Not Permissible
Minimum Wall wall thickness wall thickness
Thickness Locations locations during locations during
each inspection each inspection
period, period,
established in established in
accordance with accordance wtih
Reply (b)(1) Reply (b)(1)
[Note (2)] and [Note (2)] and
CASES OF ASME BOILER AND PRESSURE VESSEL CODE

Reply (b)(2) Reply (b)(2)


[Note (2)] [Note (2)]

NOTES:
(1) Containment surface areas requiring augmented examination are those identified in IWE-1240.
(2) The extent of examination shall be 100% for each inspection period until the areas remain essentially unchanged for the next inspection period. Such areas no longer require
augmented examination in accordance with IWE-2420(c).