MAIN EQUIPMENT PIPING / VALVES / FITTING DETAILS OF SAMPLE CONNECTION NOTES:

1 - FOR INJECTION QUILL REFER TO PIPING STANDARD AND GS EP PVV 102


VESSELS PIPING HOOK-UP STANDARDS.
2 - PIPING CLASS IS IN THE SAME MATERIAL AS CHEMICAL LINE AND MUST
CONNECTION LINE BETWEEN TWO PID GRAVITY LINE
WITHOUT POCKET
TYPE T1 01
01 KEEP PROCESS LINE DESIGN PRESSURE AND TEMPERATURE.
HORIZONTAL VESSEL 3 - SLOPE PERCENTAGE INDICATED IS PROCESS MINIMUM REQUIREMENT.
AZOTE BOTTLE FLUID DESCRIPTION 4 - MINIMIZE DISTANCE FROM PROCESS TAKE-OFF TO SAMPLE STATION.
SLOPE LINE WITH X%
PULSATION DAMPENER 01 TO/FROM MAIN EQUIPMENT 5 - SAMPLE POSITION TO BE EASY TO ACCESS.
NOTE 3 SP
PID NUMBER - 6 - USE DOBLE BLOCK WHEN NECESSARY.
PIG TRAP 7 - SELF SEAL QUICK COUPLING.
VESSEL INSULATION SAMPLE CONNEXION 8 - ALL COMPONENTS OF SAMPLING LOOP SHALL BE FULLY RATED TO 240
TANKS 01
BARG.
9 - TO BE INSTALLED IN 3 OR 9 O'CLOCK POSITION. INTRUSIVE QUILL FACING
CHECK VALVE
WELDING CONNECTION FLOW DIRECTION SAMPLING MINIMUM 75% OF FLOWLINE DIAMETER.

FREE STANDING TANK SPEC BREAK


GATE VALVE
01
01
BALL VALVE TIE IN No.
BASIN 01
01

PIPING
PG
GLOBE VALVE PIPING SPECIAL ITEM
PUMPING 01 A
SEQUENCE No.

INSTRUMENT
DOSING PUMP (CHEMICALS)
01 INSTRUMENTS PIPING
01
NEEDLE VALVE REMOVABLE SPOOL 01
WELLS
01 PG 01
3-WAY INSTRUMENT VALVE HOOK TYPE VENT B
01

CHOKE VALVE (REMOTE OPERATED)


WELL HEAD 01
01
01
COMPACT DOUBLE BLOCK
AND BLEED VALVE

COMPACT SINGLE BLOCK


AND BLEED VALVE
WELLS

BIRD SCREEN
CALIBRATION POT 01 TYPICAL A
Y STRAINER
CHEMICAL INJECTION
01 T STRAINER REMOVABLE ELBOW
FLAME ARRESTOR WITH VENT
IF REQUIRED 1", 3/4" OR 1/2"
CHEMICAL
01 MINI
LINE
1", 3/4" OR 1/2"
CORROSION COUPON

FB 3/4"
FLARE SONIC TP 2"
D
CORROSION PROBE 01 CHEMICAL
NOTE 1 PIPING
FLOW
CLASS
DRIP PAN
SPECTACLE BLIND NOTE 2
(OPEN)

DRIVERS SPECTACLE BLIND


(CLOSED) PID DRAWING :

TYPICAL A
CHEMICAL LINE
SPACER
DM ELECTRIC MOTOR
PAN TAIL (SPADE) PROCESS LINE

HUB CONNECTORS
SAFETY EQUIPMENT
REDUCER

RELIEF OR SAFETY VALVE


EXPANDER

WELDED CAP
PILOT OPERATED RELIEF VALVE 01 10/03/2023 IFA ISSUED FOR ACCEPTANCE NBu MCB PV
01
PLUG 00 08/12/2022 IFR ISSUED FOR REVIEW JMP MCB PV
01 Rev. Date Status Revision Description Iss. Check. Appr.
THREADED PLUG
PIPING / VALVES / FITTING
UBETA MAIN
01
QUICK COUPLING DEVELOPMENT PROJECT
CONTRACTOR/EQUIPMENT 01
CONTRACTOR BOUNDARY This document is the property of the TotalEnergies and it shall not be disclosed to third parties or reproduced without the express
written permission of the TotalEnergies.
MAIN PIPE OR NEW LINES ON TIE-IN PID'S INSULATING JOINT This document has been generated by an Electronic Document Management System. When printed it shall be considered as "for
information only". The controlled copy is the EDMS version and it is document holder's responsibility to make sure that latest version is
AUXILIARY SECONDARY PIPE in use.

UNDERGROUND PIPE Affiliate: TotalEnergies E&P Nigeria Ltd Site: UBM Project Phase: OV
FLEXIBLE HOSE
AIR RELEASE/ UBETA PC
VACUUM BREAKER
MH MANHOLE UBETA MAIN - P&ID STANDARD LEGENDS
ELECTRICAL TRACING
WITH INSULATION
VORTEX BREAKER Discipline: PRO Doc. Type: DRW Sector: 00 System: NN
A: ACOUSTIC
INSULATION F: FIRE Company Doc. N°: NG-UBM-00-NETD-032300 Class: 1 Scale: N/A
P: PERSONNEL PROTECTION
Contractor Doc. N°: Format: A1 Folio: 1 of 6
NOTES:
LINE NUMBER IDENTIFICATION LETTERS EQUIPMENT NUMBERING EQUIPMENT CLASSIFICATION 1 - FOR DETAILS ON PIPING MATERIAL CLASSES REFER TO "UBETA MAIN -
NOTE 2 NOTE 2 PIPING MATERIAL CLASSES", REF. NG-UBM-00-NETD-036002.
2 - REFER TO "OML 58 UPGRADE PHASE 1 - EQUIPMENT & PIPING LINES
NUMBERING PROCEDURE" REF. NG22-280-PJM-SPD-003006, REV. 00.
KEY: NNN" XX NN NN NNN XNN NN - XX - N - NN - X
D- PRESSURE VESSELS-REACTORS-SEPARATORS-SCRUBBERS

- DS Separators, scrubbers including internal or


external equipment.

PIPE SIZE SITE CODE


F- FURNACES-HEATERS-FLUES-BURNERS
FLUID TYPE EQUIPMENT TYPE
- FA Flame arrestors.

SITE CODE SECTION NUMBER


G- PUMPS-EJECTORS
EQUIPMENT CODE EQUIPMENT CHRONO
- GX pumps.

PIPING CHRONO SERIES (IF APPLICABLE)

PIPING CLASS

REF. NG22-280-PJM-SPD-003006 T- STORAGE EQUIPMENT


- TA Flat-bottomed storage tanks, gasometers (atmospheric
pressure,box) , concrete sump.
01 PRESSURE RATING SITE CODE
NOTE 1
U- COMPACT UNITS (Packages)
B FOR 150 LBS
84 UBETA PC
D FOR 300 LBS - UA Large preassembled units, mounted on skids or metal
82 OBITE TC
F FOR 600 LBS frames such as: separator/dryers/absorber units,
G FOR 900 LBS sundry modules, etc.
H FOR 1500 LBS - UB Small units of standard construction such as air and
J FOR 2500 LBS tank compressors, air dryers, cooling units, corrosion
K FOR 5000 LBS inhibitors, gas dryers, flare tip, etc.
- UN Metering Systems.

V- VP PIG TRAP

INSULATION CLASS FLUID DESIGNATION W- WELLHEAD


NOTE 2
- WH Wellhead.
- WHCP Wellhead control panel.
N NO INSULATION
P PERSONNEL PROTECTION IA INSTRUMENT AIR
CD CLOSED DRAIN
X- DRIVING MACHINES (Electric motors)
CI CORROSION INHIBITOR
ME METHANOL
FH HIGH PRESSURE FLARE - XA Asynchronous motors.
OD OPEN DRAIN - XB Synchronous motors.
NG NITROGEN - XC Other motors.
HG HYDROCARBON GAS
HC HYDROCARBON G/L
HL HYDROCARBON LIQUID
HH HYDRAULIC FLUID

PIPING ABBREVIATIONS SECTION NUMBER


NOTE 2

AG ABOVE GROUND 0 MANIFOLD.


AMB AMBIENT 1 WELL HEAD
ATM ATMOSPHERE
2 FLARE SECTION
CA CORROSION ALLOWANCE
CC CORROSION COUPON 3 SEPARATION SECTION
CP CORROSION PROBE 4 WATER TREATMENT, INJECTION.
CPY COMPANY 5 COMPRESSION SECTION.
D DRAIN POINT 6 GAS TREATMENT AND EXPORT.
EL ELEVATION
01
7 IPP-GSU.
ENG ENGINEER 01 10/03/2023 IFA ISSUED FOR ACCEPTANCE NBu MCB PV
8 UTILITY, FIREFIGHTING EQUIPMENT,
FB FULL BORE MOBILE HANDLING EQUIPMENT. 00 08/12/2022 IFR ISSUED FOR REVIEW JMP MCB PV
FC FAIL CLOSED
FCW FULL CONTROL OF WELLS 9 API, OPEN/CLOSED DRAIN, HOT WATER LOOP,
SAND JETTING, FIREWATER. Rev. Date Status Revision Description Iss. Check. Appr.
FO FAIL OPEN
HP HIGH PRESSURE
LC LOCKED CLOSED
UBETA MAIN
LO LOCKED OPEN
LP LOW PRESSURE DEVELOPMENT PROJECT
LPT LOW POINT This document is the property of the TotalEnergies and it shall not be disclosed to third parties or reproduced without the express
MP MEDIUM PRESSURE written permission of the TotalEnergies.
This document has been generated by an Electronic Document Management System. When printed it shall be considered as "for
MW MANWAY information only". The controlled copy is the EDMS version and it is document holder's responsibility to make sure that latest version is
NNF NORMALLY NO FLOW in use.

NC NORMALLY CLOSED Affiliate: TotalEnergies E&P Nigeria Ltd Site: UBM Project Phase: OV
NO NORMALLY OPEN
RS REMOVABLE SPOOL UBETA PC
SC SAMPLE CONNEXION
01
TL TANGENT LINE UBETA MAIN - P&ID STANDARD LEGENDS
TSO TIGHT SHUT OFF
UC UTILITY CONNECTION
UG UNDER GROUND
V VENT POINT Discipline: PRO Doc. Type: DRW Sector: 00 System: NN
Company Doc. N°: NG-UBM-00-NETD-032200 Class: 1 Scale: N/A
Contractor Doc. N°: Format: A1 Folio: 2 of 6
INSTRUMENTS INSTRUMENT IDENTIFICATION LETTERS GENERAL NOTES:
NOTE 1 , 2
A - INSTRUMENTS IN PACKAGED UNITS HAVE BEEN IDENTIFIED AS TYPE
P1, P2 OR P3.
LOCAL MOUNTED ON/OFF VALVE (GENERAL) POSITION OF FUNCTION LETTER IN SECOND FIELD
INSTRUMENT NOTES:
1st LETTER SUBSEQUENT 1 - REFER TO NG-UMB-00-NETD-039403 SPECIFICATION FOR INSTRUMENTATION
2-WAY SOLENOID VALVE 2nd LETTER 3rd LETTER
MAIN-PANEL MOUNTED 01 LETTER INITIATING FUNCTION FUNCTION LETTERS 01 IDENTIFICATION - ADDENDUM TO GS EP INS 102.
INSTRUMENT VARIABLE FUNCTION 2 - DELETED
HAND-RESET 3 - USER CHOICE IS INTENDED COVER UNLISTED MEANINGS THAT WILL BE
BACK OF MAIN-PANEL A ANALYSER ALARM ALARM
SOLENOID VALVE USED SEPARATELY.
MOUNTED INSTRUMENT
4 - "UNCLASSIFIED" IS INTENDED COVER UNLISTED MEANINGS THAT WILL BE
OF TECHNICAL ROOM OR
B BURNER, COMBUSTION DETECTOR USED ONLY ONCE.
MCC IN ELECTRIC ROOM
3-WAY SOLENOID VALVE 5 - THE LETTER 'S' IN THE SECOND POSITION (OR SUBSEQUENT POSITIONS).
LOCAL MAIN-PANEL C CAMERA OR USER'S CHOICE (NOTE 3) SHALL INDICATE SAFETY FUNCTION.
CONTROL
MOUNTED INSTRUMENT SELF-CONTAINED 6 - CONTROL VALVE BODY (GLOBE, BALL) IS 300# MINIMUM DESIGN
PRESSURE REDUCING (EXCEPTION WILL BE INDICATED ON PID).
REGULATOR SPECIFIC GRAVITY OR USER'S CHOICE DIFFERENTIAL, INTERFACE, RATIO
D (NOTE 3)
PROCESS CONTROL SYSTEM (PCS)
SELF-CONTAINED
BACK-PRESSURE
PROCESS COMPUTING MODULE REGULATOR E VOLTAGE PRIMARY ELEMENT
(NOT ACCESSIBLE BY OPERATOR)
F FLOW RATE
POSITIVE DISPLACEMENT HOLD :
SAFETY LOGIC SYSTEM METER INSTRUMENT WITH LOCAL INDICATION
GAS DETECTION 1 - DELETED.
* = ESD OR PSS G (EXPLOSIVITY OR TOXICITY) AND NO OTHER FUNCTION

01
HIGH SELECTING ULTRA SONIC H HAND RUN, HIGH, OPEN RUN, HIGH, OPEN
* INITIATING VARIABLE TYPE FLOWMETER
I CURRENT (ELECTRICAL) INDICATION

LOW SELECTING J POWER


* INITIATING VARIABLE ROTAMETER
K TIME CONTROL STATION
LOGIC INPUT L LEVEL LIGHT STOP, LOW, CLOSED STOP, LOW, CLOSED
DIAPHRAGM SEAL
* = ESD1, SD2 OR SD3
ELECTRICAL CONSUMER
LOGIC OUTPUT RESTRICTION ORIFICE M (AS PREFIX TO INITIATING VARIABLE)
* = ESD1, SD2 OR SD3
N FIRE DETECTION
01
O USER'S CHOICE (NOTE 3) ORIFICE
RESTRICTION ORIFICE

PUSH BUTTON P PRESSURE, VACUUM TEST POINT

CONTROL FUNCTION CARRIED Q QUANTITY TOTALIZE, INTEGRATED LEGEND:


OUT IN PACKAGE UNIT
R RADIATION RECORD REMOTE ON / OFF VALVES
CONTROL PANEL
* = UCP (TCP) - * EV : SOLENOID VALVE.
S SPEED, FREQUENCY SAFETY (NOTE 5)
- * HKH/L : OPEN OR CLOSE HAND CONTROL.
- * ZH/L : OPEN / CLOSED STATUS.
INDEFINED INTERLOCK LOGIC (PCS) T TEMPERATURE TRANSMITTER
- * ZA : OPEN / CLOSED DISCREPANCY ALARM.
U MULTIVARIABLE
PCS OUTPUT SELECTOR 01
MECHANICAL QUANTITY, -* : CORRESPONDS TO FIRST LETTER OF VALVE (S,B...).
V VALVE
VIBRATION, MOVEMENT
CONTROL VALVE WITH
W WEIGHT, FORCE THERMOWELL
DIAPHRAGM ACTUATOR
(GENERAL) (NOTE 6)
01 UNCLASSIFIED, SEQUENCE (NOTE 4) AUTOMATIC CONTROL FUNCTION
X
Y STATE, EVENT, PRESENCE COMPUTE, CONVERT

SOFTWARE SIGNAL Z POSITION POSITION

ELECTRICAL/ELECTRONICAL SIGNAL
INSTRUMENTATION ABBREVIATIONS INSTRUMENT SIGNAL LINES
MOTOR CONTROL CENTER INSTRUMENT LINE
BDV BLOWDOWN VALVE RO RESTRICTION ORIFICE
CCR CENTRAL CONTROL ROOM ROCV REMOTE OPERATED VALVE
PNEUMATIC SIGNAL
CSS CONTROL & SAFETY SYSTEM SCSSV SURFACE CONTROLLED
DCS DISTRIBUTION CONTROL SYSTEM SUB-SURFACE SAFETY VALVE
ELECTRICAL OR
ESD EMERGENCY SHUT DOWN SD2/3 SHUTDOWN (LEVEL 2/3)
ELECTRONIC SIGNAL
REPRESENTATION ON PID ESDV EMERGENCY SHUT DOWN VALVE SDV SHUTDOWN VALVE
HYDRAULIC SIGNAL
FGS FIRE & GAS SYSTEM SSV SURFACE SAFETY VALVE
CAPILLARY TUBING
WHFP WELLHEAD FLOWING PRESSURE
SAFETY FUNCTION IN CSS FC FAIL CLOSED WITH LIQUID OR
FO FAIL OPEN WHFT WELLHEAD FLOWING TEMPERATURE GAS EXPANSION

CONVENTIONAL DRAWING PID DRAWING FL FAIL LOCKED WHSIP WELLHEAD SHUT-IN PRESSURE SOFTWARE LINK
01 10/03/2023 IFA ISSUED FOR ACCEPTANCE NBu MCB PV
H/R HYDRAULIC RETURN XV ACTUATED ON/OFF VALVE
TELETRANSMISSION 00 08/12/2022 IFR ISSUED FOR REVIEW JMP MCB PV
H/S HYDRAULIC SUPPLY SIGNAL.
Rev. Date Status Revision Description Iss. Check. Appr.
OPPS OVERPRESSURE PROTECTION SYSTEM
PB PUSH BUTTON 01 TYPICAL FOR PSV UBETA MAIN
PCS PROCESS CONTROL SYSTEM
DEVELOPMENT PROJECT
PSS PROCESS SAFETY SYSTEM
This document is the property of the TotalEnergies and it shall not be disclosed to third parties or reproduced without the express
PSV PRESSURE SAFETY VALVE written permission of the TotalEnergies.
This document has been generated by an Electronic Document Management System. When printed it shall be considered as "for
PV PRESSURE VALVE information only". The controlled copy is the EDMS version and it is document holder's responsibility to make sure that latest version is
INDICATION AND ALARM SET PRESSURE BARG in use.
THRESHOLD (H/L) ARE Affiliate: TotalEnergies E&P Nigeria Ltd Site: UBM Project Phase: OV
IMPLICITE IN PCS.
PSV SIZE UBETA PC
CONTROLLER WITH HIGH / LOW ALARM
ALARM
TAG NUMBER UBETA MAIN - P&ID STANDARD LEGENDS

Discipline: PRO Doc. Type: DRW Sector: 00 System: NN


Company Doc. N°: NG-UBM-00-NETD-032300 Class: 1 Scale: N/A
Contractor Doc. N°: Format: A1 Folio: 3 of 6
GENERAL NOTES:
SYMBOLS INSTRUMENTS A - TYPE OF VALVE IS IN ACCORDANCE WITH PIPING CLASS.
B - THIS DRAWING IS USED AS A TYPICAL OF INSTRUMENTATION PID,
CONVENTIONAL PID DRAWING CONVENTIONAL PID DRAWING CONVENTIONAL PID DRAWING BUT NOT AS A TYPICAL OF INSTRUMENT MOUNTING.
DRAWING DRAWING DRAWING C - INSTRUMENT MOUNTING IS IN ACCORDANCE WITH INSTRUMENT HOOK-UP
PRESSURE GAUGE DRAWING : NG-UBM-00-NETD-039417 INSTRUMENT HOOK-UP
LEVEL GAUGE LEVEL GAUGE WITH RECOVERED DRAIN
WITH TRACE DIAGRAMS - ADDENDUM TO GS EP INS 900.
(ASSEMBLY ON VESSELS) FOR HYDROCARBONS 01
HEATING D - WHERE INDICATED ON PID, DOUBLE BLOCK AND BLEED VALVE WERE USED
NOTE 1
1 FOR PIPING CLASS < 600# 1 FOR PIPING CLASS < 600#
FOR PIPING CLASS RATING OF 600# AND ABOVE (OPERATING PRESSURE
INST.
N INST. 1/2" >70 BARG).
1/2"
N E PIPING E - ALL THE DOUBLE BLOCK AND BLEED VALVES TYPE SHALL BE SUBMITIED TO
COMPANY FOR APPROVAL PRIOR TO PURCHASE.
PIPING

ATM
E

ATM
01 PIPING INST. INST. PIPING

01
3/4"
01 1/2"
ATM
3/4" ATM
1" 1/2" ATM
1"
2"
1 2 2"

FOR PIPING CLASS < 600# FOR PIPING CLASS ≥ 600# NOTE 3

NOTES:
PRESSURE TRANSMITTER
ATM 1 - LIMIT OF ELECTRICAL TRACING AND HEAT INSULATION IF REQUIRED.
1"
WITH TRACE
1"
ATM
01 2 - DELETED.
HEATING
3 - MINIMUM FLANGE RATING : 300#.

INST.
2" 1/2"
NOTE 1
2" 4 - QUICK COUPLING CONNECTION TO MOBILE DRAIN SYSTEM.

NOTE 1
1/2"

E
5 - FOR NO RECOVERED PRODUCTS AND CHEMICAL PRODUCTS THE LEVEL
INST.

INST. 1/2"

PIPING
E N

N
3/4"X1/2" NOTE 4
PIPING INSTRUMENT DRAIN OR VENT ARE EQUIPPED WITH A 1/2" VALVE FITTED
N

1/2" NOTES 3,5


WITH A THREADED PLUG.
PIPING

ATM ATM
E

NOTE 4 6 - SHUTDOWN FUNCTION BY ESD OR PSS.


3/4" 01
3/4"
01
2 FOR PIPING CLASS ≥ 600#
1 FOR PIPING CLASS < 600# TEMPERATURE AND PRESSURE TEMPERATURE AND PRESSURE
01 (ASSEMBLY ON VESSELS) (ASSEMBLY ON VESSELS)
1 2 PG
FOR PIPING CLASS < 600# FOR PIPING CLASS ≥ 600# PG PT

INST.
PT

INST.
PG TW 1/2" PG TW
DIFFERENCIAL PRESSURE GAUGE 1/2" PT TG PT TG

PIPING
FOR PIPING CLASS < 600# TT TT
ATM ATM

PIPING

INST.
INST.
WITH TRACE
HEATING 01 2"
INST.

3/4"
2" 2"

SUPPLIER
2" 2"

SUPPLIER
N

1/2"
NOTE 3 NOTE 3
PIPING
E

ATM ATM
01
3/4"

2 FOR PIPING CLASS ≥ 600#

NOTE 1
INST.

1/2" 1/2"
01
E N

PIPING

ATM ATM

01 TYPICAL DUTY / STAND-BY MOTORS - P < 110 KW


3/4" 3/4"
WITH MANUAL START/STOP COMMAND
TYPE M04
TEMPERATURE PIPE Ø ≥ 4" TEMPERATURE PIPE Ø < 4" P&ID 01
REPRESENTATION START/STOP START/STOP
A DUTY/STAND-BY B

LEGEND:
MCC
M : MOTOR
MCC : MOTOR CONTROL CENTER
TW MHKDS : DUTY/STAND-BYSELECTION
TW
TG MHKHL : ON/OFF HAND CONTROL
TT
TG MXK : ON/OFF COMMAND
INST.

TW TUY. Ø ≤ 3" TW
TT
TG
2" MXS : STOP SAFETY FUNCTION
TG
INST.

MXF : MOTOR UNAVAILABLE / ELECTRICAL FAULT


2"
2"
TT
01
PIPING

TYPE M04 ESD ESD MZHL : ON/OFF MOTOR STATUS 01


2"
PIPING

4" 4"

TUY. Ø ≥ 4"

NOTE 6
01 01

PIG SIGNALLER
ON/OFF MOTOR

ON/OFF MOTOR

UNAVAILABLE /
UNAVAILABLE /

SHUTDOWN

SHUTDOWN
COMMAND

COMMAND
STATUS

STATUS
ON/OFF

ON/OFF

FAULT
FAULT

01 10/03/2023 IFA ISSUED FOR ACCEPTANCE PP MCB PV


00 08/12/2022 IFR ISSUED FOR REVIEW JMP MCB PV
01 Rev. Date Status Revision Description Iss. Check. Appr.

UBETA MAIN
ZS MCC MCC
ZS MOTOR STARTER B DEVELOPMENT PROJECT
MOTOR STARTER A
INST.

2" This document is the property of the TotalEnergies and it shall not be disclosed to third parties or reproduced without the express
written permission of the TotalEnergies.
This document has been generated by an Electronic Document Management System. When printed it shall be considered as "for
information only". The controlled copy is the EDMS version and it is document holder's responsibility to make sure that latest version is
2"
PIPING

in use.

Affiliate: TotalEnergies E&P Nigeria Ltd Site: UBM Project Phase: OV

START, START, UBETA PC


EMERGENCY/NORMAL STOP EMERGENCY/NORMAL STOP UBETA MAIN - P&ID STANDARD LEGENDS

01 LOCAL CONTROL STATION LOCAL CONTROL STATION


Discipline: PRO Doc. Type: DRW Sector: 00 System: NN
= NUMERIC CODE IN THE SERIAL NUMBER IS
REPLACED BY THE IDENTIFIER OF THE EQUIPMENT Company Doc. N°: NG-UBM-00-NETD-032300 Class: 1 Scale: N/A
Contractor Doc. N°: Format: A1 Folio: 4 of 6
VANNES TYPICALS
TYPE 1 : ESDV SINGLE ACTING WITH LOCAL RESET, SOLENOID VALVE TEST AND TYPE 2A : SDV SINGLE ACTING WITH OPPS/PSS CONTROL, SOLENOID VALVE
PARTIAL STROKE TEST (PNEUMATIC) TEST AND PARTIAL STROKE TEST (PNEUMATIC)
PID PID
REPRESENTATION REPRESENTATION

OPPS
SD

SD
~ ESDV ~ SDV
- -
VALVE VALVE
TAG TAG
~

~
NUMBER NUMBER
FB
FB
FC FC
TYPE 1 TYPE 2A
ESD SIGNAL PSS SIGNAL OPPS SIGNAL
SOV OVERRIDE SOV OVERRIDE SOV OVERRIDE

ESD PSS OPPS

LOCAL CONTROL LOCAL CONTROL


PANEL PANEL

SOV SOV SOV


ESPSL OVERRIDE SPSL2 OVERRIDE SPSL1 OVERRIDE
- KEY - KEY - KEY

EEV EPBC2 SEV2 SPBC2-2 SEV1 SPBC2-1


- - - - - -

ESD OPPS PSS


LOCAL LOCAL
OPEN COMMAND OPEN COMMAND
(KEY PROTECTED) (KEY PROTECTED)

EPBC SPBC
- -

ESZH ESZL SZH1 SZL1 SZH2 SZL2


- - - - - -

ESZH ESZL SZH1 SZL1 SZH2 SZL2


- - - - - -
EPBC3 SPBC3
- -

ESDV SDV
- -
~

~
TYPE 11 : ESDV SINGLE ACTING WITH LOCAL RESET, SOLENOID VALVE TEST AND TYPE 12A : SDV SINGLE ACTING WITH SOLENOID VALVE TEST AND PARTIAL STROKE
PARTIAL STROKE TEST (HYDRAULIC) TEST (HYDRAULIC)
PID PID
REPRESENTATION REPRESENTATION
OPPS
SD

~ BDV SD ~ BDV
- -

VALVE VALVE
TAG TAG
~

~
FB NUMBER FB NUMBER
FO FO
TYPE 11 TYPE 12A
NEW FOLIO AT REVISION 01
ESD SIGNAL PSS SIGNAL
SOV OVERRIDE SOV OVERRIDE
01
ESD PSS

LOCAL CONTROL LOCAL CONTROL


PANEL PANEL

SOV SOV
ESPSL OVERRIDE SPSL OVERRIDE
- KEY - KEY

EEV EPBC2 SEV SPBC2


- - - -

01 10/03/2023 IFA ISSUED FOR ACCEPTANCE PP MCB PV


00 08/12/2022 IFR ISSUED FOR REVIEW JMP MCB PV
Rev. Date Status Revision Description Iss. Check. Appr.
ESD OPPS
LOCAL LOCAL
UBETA MAIN
OPEN COMMAND OPEN COMMAND
(KEY PROTECTED) (KEY PROTECTED) DEVELOPMENT PROJECT
EPBC SPBC This document is the property of the TotalEnergies and it shall not be disclosed to third parties or reproduced without the express
- - written permission of the TotalEnergies.
This document has been generated by an Electronic Document Management System. When printed it shall be considered as "for
information only". The controlled copy is the EDMS version and it is document holder's responsibility to make sure that latest version is
ESZH ESZL SZH SZL in use.
- - - -
Affiliate: TotalEnergies E&P Nigeria Ltd Site: UBM Project Phase: OV

UBETA PC
ESZH ESZL SZH SZL
- - - -
EPBC3
-
SPBC3
-
UBETA MAIN - P&ID STANDARD LEGENDS
ESDV SDV
- -
Discipline: PRO Doc. Type: DRW Sector: 00 System: NN
~

~
Company Doc. N°: NG-UBM-00-NETD-032200 Class: 1 Scale: N/A
Contractor Doc. N°: Format: A1 Folio: 5 of 6
VANNES TYPICALS
TYPE 2B : SDV SINGLE ACTING (PNEUMATIC) TYPE 12B : SDV SINGLE ACTING (HYDRAULIC) TYPE 3 : BDV SINGLE ACTING WITH LOCAL RESET AND SOLENOID VALVE
TEST (PNEUMATIC)
PID PID PID
REPRESENTATION REPRESENTATION REPRESENTATION

EDP
SD

SD
~
~ SDV SDV ~ BDV
- - -

VALVE VALVE VALVE


TAG TAG TAG
~

~
NUMBER NUMBER NUMBER
FB/RB FB/RB FB
FC FC FO
TYPE 2B TYPE 12B TYPE 3

PSS PSS ESD SOV OVERRIDE ESD RESET


SIGNAL SIGNAL
ESD ESD

LOCAL CONTROL LOCAL CONTROL LOCAL CONTROL


PANEL PANEL PANEL
ESD BPBR
RESET -

SOV
BPSL OVERRIDE
- KEY

SEV SEV BPBO2


BEV -
- -
-

PSS
PSS ESD

LOCAL LOCAL LOCAL


CLOSE SZH SZL CLOSE OPEN COMMAND
COMMAND - - COMMAND (KEY PROTECTED)
SZH SZL BZH BZL

SPBC SPBC
- - BPBO
- -
- - -

SZH SZL
- -
SZH SZL BZH BZL
- - - -

SDV BDV
- -
SDV
-
~

~
~

~
NEW FOLIO AT REVISION 01

01

01 10/03/2023 IFA ISSUED FOR ACCEPTANCE PP MCB PV


00 08/12/2022 IFR ISSUED FOR REVIEW JMP MCB PV
Rev. Date Status Revision Description Iss. Check. Appr.

UBETA MAIN
DEVELOPMENT PROJECT
This document is the property of the TotalEnergies and it shall not be disclosed to third parties or reproduced without the express
written permission of the TotalEnergies.
This document has been generated by an Electronic Document Management System. When printed it shall be considered as "for
information only". The controlled copy is the EDMS version and it is document holder's responsibility to make sure that latest version is
in use.

Affiliate: TotalEnergies E&P Nigeria Ltd Site: UBM Project Phase: OV

UBETA PC
UBETA MAIN - P&ID STANDARD LEGENDS

Discipline: PRO Doc. Type: DRW Sector: 00 System: NN


Company Doc. N°: NG-UBM-00-NETD-032200 Class: 1 Scale: N/A
Contractor Doc. N°: Format: A1 Folio: 6 of 6