NG Ubm 00 Netd 032300 - 01 - Ifa1 - 20230310
NG Ubm 00 Netd 032300 - 01 - Ifa1 - 20230310
PIPING
PG
GLOBE VALVE PIPING SPECIAL ITEM
PUMPING 01 A
SEQUENCE No.
INSTRUMENT
DOSING PUMP (CHEMICALS)
01 INSTRUMENTS PIPING
01
NEEDLE VALVE REMOVABLE SPOOL 01
WELLS
01 PG 01
3-WAY INSTRUMENT VALVE HOOK TYPE VENT B
01
BIRD SCREEN
CALIBRATION POT 01 TYPICAL A
Y STRAINER
CHEMICAL INJECTION
01 T STRAINER REMOVABLE ELBOW
FLAME ARRESTOR WITH VENT
IF REQUIRED 1", 3/4" OR 1/2"
CHEMICAL
01 MINI
LINE
1", 3/4" OR 1/2"
CORROSION COUPON
FB 3/4"
FLARE SONIC TP 2"
D
CORROSION PROBE 01 CHEMICAL
NOTE 1 PIPING
FLOW
CLASS
DRIP PAN
SPECTACLE BLIND NOTE 2
(OPEN)
TYPICAL A
CHEMICAL LINE
SPACER
DM ELECTRIC MOTOR
PAN TAIL (SPADE) PROCESS LINE
HUB CONNECTORS
SAFETY EQUIPMENT
REDUCER
WELDED CAP
PILOT OPERATED RELIEF VALVE 01 10/03/2023 IFA ISSUED FOR ACCEPTANCE NBu MCB PV
01
PLUG 00 08/12/2022 IFR ISSUED FOR REVIEW JMP MCB PV
01 Rev. Date Status Revision Description Iss. Check. Appr.
THREADED PLUG
PIPING / VALVES / FITTING
UBETA MAIN
01
QUICK COUPLING DEVELOPMENT PROJECT
CONTRACTOR/EQUIPMENT 01
CONTRACTOR BOUNDARY This document is the property of the TotalEnergies and it shall not be disclosed to third parties or reproduced without the express
written permission of the TotalEnergies.
MAIN PIPE OR NEW LINES ON TIE-IN PID'S INSULATING JOINT This document has been generated by an Electronic Document Management System. When printed it shall be considered as "for
information only". The controlled copy is the EDMS version and it is document holder's responsibility to make sure that latest version is
AUXILIARY SECONDARY PIPE in use.
UNDERGROUND PIPE Affiliate: TotalEnergies E&P Nigeria Ltd Site: UBM Project Phase: OV
FLEXIBLE HOSE
AIR RELEASE/ UBETA PC
VACUUM BREAKER
MH MANHOLE UBETA MAIN - P&ID STANDARD LEGENDS
ELECTRICAL TRACING
WITH INSULATION
VORTEX BREAKER Discipline: PRO Doc. Type: DRW Sector: 00 System: NN
A: ACOUSTIC
INSULATION F: FIRE Company Doc. N°: NG-UBM-00-NETD-032300 Class: 1 Scale: N/A
P: PERSONNEL PROTECTION
Contractor Doc. N°: Format: A1 Folio: 1 of 6
NOTES:
LINE NUMBER IDENTIFICATION LETTERS EQUIPMENT NUMBERING EQUIPMENT CLASSIFICATION 1 - FOR DETAILS ON PIPING MATERIAL CLASSES REFER TO "UBETA MAIN -
NOTE 2 NOTE 2 PIPING MATERIAL CLASSES", REF. NG-UBM-00-NETD-036002.
2 - REFER TO "OML 58 UPGRADE PHASE 1 - EQUIPMENT & PIPING LINES
NUMBERING PROCEDURE" REF. NG22-280-PJM-SPD-003006, REV. 00.
KEY: NNN" XX NN NN NNN XNN NN - XX - N - NN - X
D- PRESSURE VESSELS-REACTORS-SEPARATORS-SCRUBBERS
PIPING CLASS
V- VP PIG TRAP
NC NORMALLY CLOSED Affiliate: TotalEnergies E&P Nigeria Ltd Site: UBM Project Phase: OV
NO NORMALLY OPEN
RS REMOVABLE SPOOL UBETA PC
SC SAMPLE CONNEXION
01
TL TANGENT LINE UBETA MAIN - P&ID STANDARD LEGENDS
TSO TIGHT SHUT OFF
UC UTILITY CONNECTION
UG UNDER GROUND
V VENT POINT Discipline: PRO Doc. Type: DRW Sector: 00 System: NN
Company Doc. N°: NG-UBM-00-NETD-032200 Class: 1 Scale: N/A
Contractor Doc. N°: Format: A1 Folio: 2 of 6
INSTRUMENTS INSTRUMENT IDENTIFICATION LETTERS GENERAL NOTES:
NOTE 1 , 2
A - INSTRUMENTS IN PACKAGED UNITS HAVE BEEN IDENTIFIED AS TYPE
P1, P2 OR P3.
LOCAL MOUNTED ON/OFF VALVE (GENERAL) POSITION OF FUNCTION LETTER IN SECOND FIELD
INSTRUMENT NOTES:
1st LETTER SUBSEQUENT 1 - REFER TO NG-UMB-00-NETD-039403 SPECIFICATION FOR INSTRUMENTATION
2-WAY SOLENOID VALVE 2nd LETTER 3rd LETTER
MAIN-PANEL MOUNTED 01 LETTER INITIATING FUNCTION FUNCTION LETTERS 01 IDENTIFICATION - ADDENDUM TO GS EP INS 102.
INSTRUMENT VARIABLE FUNCTION 2 - DELETED
HAND-RESET 3 - USER CHOICE IS INTENDED COVER UNLISTED MEANINGS THAT WILL BE
BACK OF MAIN-PANEL A ANALYSER ALARM ALARM
SOLENOID VALVE USED SEPARATELY.
MOUNTED INSTRUMENT
4 - "UNCLASSIFIED" IS INTENDED COVER UNLISTED MEANINGS THAT WILL BE
OF TECHNICAL ROOM OR
B BURNER, COMBUSTION DETECTOR USED ONLY ONCE.
MCC IN ELECTRIC ROOM
3-WAY SOLENOID VALVE 5 - THE LETTER 'S' IN THE SECOND POSITION (OR SUBSEQUENT POSITIONS).
LOCAL MAIN-PANEL C CAMERA OR USER'S CHOICE (NOTE 3) SHALL INDICATE SAFETY FUNCTION.
CONTROL
MOUNTED INSTRUMENT SELF-CONTAINED 6 - CONTROL VALVE BODY (GLOBE, BALL) IS 300# MINIMUM DESIGN
PRESSURE REDUCING (EXCEPTION WILL BE INDICATED ON PID).
REGULATOR SPECIFIC GRAVITY OR USER'S CHOICE DIFFERENTIAL, INTERFACE, RATIO
D (NOTE 3)
PROCESS CONTROL SYSTEM (PCS)
SELF-CONTAINED
BACK-PRESSURE
PROCESS COMPUTING MODULE REGULATOR E VOLTAGE PRIMARY ELEMENT
(NOT ACCESSIBLE BY OPERATOR)
F FLOW RATE
POSITIVE DISPLACEMENT HOLD :
SAFETY LOGIC SYSTEM METER INSTRUMENT WITH LOCAL INDICATION
GAS DETECTION 1 - DELETED.
* = ESD OR PSS G (EXPLOSIVITY OR TOXICITY) AND NO OTHER FUNCTION
01
HIGH SELECTING ULTRA SONIC H HAND RUN, HIGH, OPEN RUN, HIGH, OPEN
* INITIATING VARIABLE TYPE FLOWMETER
I CURRENT (ELECTRICAL) INDICATION
ELECTRICAL/ELECTRONICAL SIGNAL
INSTRUMENTATION ABBREVIATIONS INSTRUMENT SIGNAL LINES
MOTOR CONTROL CENTER INSTRUMENT LINE
BDV BLOWDOWN VALVE RO RESTRICTION ORIFICE
CCR CENTRAL CONTROL ROOM ROCV REMOTE OPERATED VALVE
PNEUMATIC SIGNAL
CSS CONTROL & SAFETY SYSTEM SCSSV SURFACE CONTROLLED
DCS DISTRIBUTION CONTROL SYSTEM SUB-SURFACE SAFETY VALVE
ELECTRICAL OR
ESD EMERGENCY SHUT DOWN SD2/3 SHUTDOWN (LEVEL 2/3)
ELECTRONIC SIGNAL
REPRESENTATION ON PID ESDV EMERGENCY SHUT DOWN VALVE SDV SHUTDOWN VALVE
HYDRAULIC SIGNAL
FGS FIRE & GAS SYSTEM SSV SURFACE SAFETY VALVE
CAPILLARY TUBING
WHFP WELLHEAD FLOWING PRESSURE
SAFETY FUNCTION IN CSS FC FAIL CLOSED WITH LIQUID OR
FO FAIL OPEN WHFT WELLHEAD FLOWING TEMPERATURE GAS EXPANSION
CONVENTIONAL DRAWING PID DRAWING FL FAIL LOCKED WHSIP WELLHEAD SHUT-IN PRESSURE SOFTWARE LINK
01 10/03/2023 IFA ISSUED FOR ACCEPTANCE NBu MCB PV
H/R HYDRAULIC RETURN XV ACTUATED ON/OFF VALVE
TELETRANSMISSION 00 08/12/2022 IFR ISSUED FOR REVIEW JMP MCB PV
H/S HYDRAULIC SUPPLY SIGNAL.
Rev. Date Status Revision Description Iss. Check. Appr.
OPPS OVERPRESSURE PROTECTION SYSTEM
PB PUSH BUTTON 01 TYPICAL FOR PSV UBETA MAIN
PCS PROCESS CONTROL SYSTEM
DEVELOPMENT PROJECT
PSS PROCESS SAFETY SYSTEM
This document is the property of the TotalEnergies and it shall not be disclosed to third parties or reproduced without the express
PSV PRESSURE SAFETY VALVE written permission of the TotalEnergies.
This document has been generated by an Electronic Document Management System. When printed it shall be considered as "for
PV PRESSURE VALVE information only". The controlled copy is the EDMS version and it is document holder's responsibility to make sure that latest version is
INDICATION AND ALARM SET PRESSURE BARG in use.
THRESHOLD (H/L) ARE Affiliate: TotalEnergies E&P Nigeria Ltd Site: UBM Project Phase: OV
IMPLICITE IN PCS.
PSV SIZE UBETA PC
CONTROLLER WITH HIGH / LOW ALARM
ALARM
TAG NUMBER UBETA MAIN - P&ID STANDARD LEGENDS
ATM
E
ATM
01 PIPING INST. INST. PIPING
01
3/4"
01 1/2"
ATM
3/4" ATM
1" 1/2" ATM
1"
2"
1 2 2"
FOR PIPING CLASS < 600# FOR PIPING CLASS ≥ 600# NOTE 3
NOTES:
PRESSURE TRANSMITTER
ATM 1 - LIMIT OF ELECTRICAL TRACING AND HEAT INSULATION IF REQUIRED.
1"
WITH TRACE
1"
ATM
01 2 - DELETED.
HEATING
3 - MINIMUM FLANGE RATING : 300#.
INST.
2" 1/2"
NOTE 1
2" 4 - QUICK COUPLING CONNECTION TO MOBILE DRAIN SYSTEM.
NOTE 1
1/2"
E
5 - FOR NO RECOVERED PRODUCTS AND CHEMICAL PRODUCTS THE LEVEL
INST.
INST. 1/2"
PIPING
E N
N
3/4"X1/2" NOTE 4
PIPING INSTRUMENT DRAIN OR VENT ARE EQUIPPED WITH A 1/2" VALVE FITTED
N
ATM ATM
E
INST.
PT
INST.
PG TW 1/2" PG TW
DIFFERENCIAL PRESSURE GAUGE 1/2" PT TG PT TG
PIPING
FOR PIPING CLASS < 600# TT TT
ATM ATM
PIPING
INST.
INST.
WITH TRACE
HEATING 01 2"
INST.
3/4"
2" 2"
SUPPLIER
2" 2"
SUPPLIER
N
1/2"
NOTE 3 NOTE 3
PIPING
E
ATM ATM
01
3/4"
NOTE 1
INST.
1/2" 1/2"
01
E N
PIPING
ATM ATM
LEGEND:
MCC
M : MOTOR
MCC : MOTOR CONTROL CENTER
TW MHKDS : DUTY/STAND-BYSELECTION
TW
TG MHKHL : ON/OFF HAND CONTROL
TT
TG MXK : ON/OFF COMMAND
INST.
TW TUY. Ø ≤ 3" TW
TT
TG
2" MXS : STOP SAFETY FUNCTION
TG
INST.
4" 4"
TUY. Ø ≥ 4"
NOTE 6
01 01
PIG SIGNALLER
ON/OFF MOTOR
ON/OFF MOTOR
UNAVAILABLE /
UNAVAILABLE /
SHUTDOWN
SHUTDOWN
COMMAND
COMMAND
STATUS
STATUS
ON/OFF
ON/OFF
FAULT
FAULT
UBETA MAIN
ZS MCC MCC
ZS MOTOR STARTER B DEVELOPMENT PROJECT
MOTOR STARTER A
INST.
2" This document is the property of the TotalEnergies and it shall not be disclosed to third parties or reproduced without the express
written permission of the TotalEnergies.
This document has been generated by an Electronic Document Management System. When printed it shall be considered as "for
information only". The controlled copy is the EDMS version and it is document holder's responsibility to make sure that latest version is
2"
PIPING
in use.
OPPS
SD
SD
~ ESDV ~ SDV
- -
VALVE VALVE
TAG TAG
~
~
NUMBER NUMBER
FB
FB
FC FC
TYPE 1 TYPE 2A
ESD SIGNAL PSS SIGNAL OPPS SIGNAL
SOV OVERRIDE SOV OVERRIDE SOV OVERRIDE
EPBC SPBC
- -
ESDV SDV
- -
~
~
TYPE 11 : ESDV SINGLE ACTING WITH LOCAL RESET, SOLENOID VALVE TEST AND TYPE 12A : SDV SINGLE ACTING WITH SOLENOID VALVE TEST AND PARTIAL STROKE
PARTIAL STROKE TEST (HYDRAULIC) TEST (HYDRAULIC)
PID PID
REPRESENTATION REPRESENTATION
OPPS
SD
~ BDV SD ~ BDV
- -
VALVE VALVE
TAG TAG
~
~
FB NUMBER FB NUMBER
FO FO
TYPE 11 TYPE 12A
NEW FOLIO AT REVISION 01
ESD SIGNAL PSS SIGNAL
SOV OVERRIDE SOV OVERRIDE
01
ESD PSS
SOV SOV
ESPSL OVERRIDE SPSL OVERRIDE
- KEY - KEY
UBETA PC
ESZH ESZL SZH SZL
- - - -
EPBC3
-
SPBC3
-
UBETA MAIN - P&ID STANDARD LEGENDS
ESDV SDV
- -
Discipline: PRO Doc. Type: DRW Sector: 00 System: NN
~
~
Company Doc. N°: NG-UBM-00-NETD-032200 Class: 1 Scale: N/A
Contractor Doc. N°: Format: A1 Folio: 5 of 6
VANNES TYPICALS
TYPE 2B : SDV SINGLE ACTING (PNEUMATIC) TYPE 12B : SDV SINGLE ACTING (HYDRAULIC) TYPE 3 : BDV SINGLE ACTING WITH LOCAL RESET AND SOLENOID VALVE
TEST (PNEUMATIC)
PID PID PID
REPRESENTATION REPRESENTATION REPRESENTATION
EDP
SD
SD
~
~ SDV SDV ~ BDV
- - -
~
NUMBER NUMBER NUMBER
FB/RB FB/RB FB
FC FC FO
TYPE 2B TYPE 12B TYPE 3
SOV
BPSL OVERRIDE
- KEY
PSS
PSS ESD
SPBC SPBC
- - BPBO
- -
- - -
SZH SZL
- -
SZH SZL BZH BZL
- - - -
SDV BDV
- -
SDV
-
~
~
~
~
NEW FOLIO AT REVISION 01
01
UBETA MAIN
DEVELOPMENT PROJECT
This document is the property of the TotalEnergies and it shall not be disclosed to third parties or reproduced without the express
written permission of the TotalEnergies.
This document has been generated by an Electronic Document Management System. When printed it shall be considered as "for
information only". The controlled copy is the EDMS version and it is document holder's responsibility to make sure that latest version is
in use.
UBETA PC
UBETA MAIN - P&ID STANDARD LEGENDS