Product data sheet

System FWE200DH
FWE200DH

DUST MEASURING DEVICES


System FWE200DH | FWE200DH
DUST MEASURING DEVICES

A Ordering information

Type Part no.

B System FWE200DH On request

C Our regional sales organization will help you to select the optimum device configuration.

Other models and accessories www.sick.com/FWE200DH

D
E
15267 14181
certified certified

F Detailed technical data


Technical specifications
Measured values Scattered light intensity, dust concentration (after gravimetric comparison measurement)

Performance-tested measurands Dust concentration

H Measurement principles
Spectral range
Scattered light forward

I
640 nm ... 660 nm
Laser, protection class 2, power < 1 mW
Measuring ranges

J Dust concentration 0 ... 5 mg/m³ / 0 ... 500 mg/m³


Measuring ranges freely selectable
Higher measuring ranges on request

K Certified measuring ranges


Dust concentration 0 ... 7.5 mg/m³ / 0 ... 10 mg/m³ / 0 ... 15 mg/m³ / 0 ... 50 mg/m³ / 0 ... 100 mg/m³ / 0 ...
500 mg/m³

L Response time (t90) 0.1 s ... 600 s


Freely adjustable

M
Accuracy
±2%
Of measuring range full scale

N Process temperature
PVDF gas removal probe: ≤ +120 °C

O
Hastelloy gas removal probe: ≤ +220 °C
Versions for higher temperatures on request
Process pressure

P With SLV7 2BH1100 purge air unit: –20 hPa ... 20 hPa
Other pressure ranges on request
Process gas velocity

Q Process gas humidity


5 m/s ... 30 m/s

R Ambient temperature
Max. 40 g/m³ liquid water without water vapour

–20 °C ... +50 °C

S
T 2 DUST MEASURING DEVICES | SICK Product data sheet | 2024-04-22 21:20:32
Subject to change without notice
System FWE200DH | FWE200DH
DUST MEASURING DEVICES

Intake temperatures for purge air: –20 °C ... +45 °C


Conformities Approved for plants requiring approval
2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
U.S. EPA PS-11 compliant
When options are used, agreement with local authorities may be required
Electrical safety CE

Enclosure rating
Measuring and control unit IP54
Electronics enclosure IP65
Analog outputs 3 outputs:
0/2/4 ... 20 mA, + 750 Ω
Electrically isolated
Analog inputs 6 inputs:
0 ... 20 mA
Not electrically isolated
Digital outputs 5 relay outputs (change-over contacts), potential-free:
48 V, 1 A
Digital inputs 8 inputs

Modbus ✔, ✔
Modbus
Type of fieldbus integration TCP (via optional interface module, only one module possible per MCU)
RTU RS-485 (via optional interface module, only one module possible per MCU)
PROFIBUS DP ✔
Type of fieldbus integration Via optional interface module (only one module possible per MCU)
Ethernet ✔
Type of fieldbus integration Via optional interface module (only one module possible per MCU)
Function Connection to SOPAS ET software or OPC server
Serial ✔
Type of fieldbus integration RS-232
Function Proprietary service interface
Indication
LC display and status LEDs on control and remote unit
Input Functional keys

Operation Menu-driven operation via control unit or software SOPAS ET

Dimensions (W x H x D)
FWE200DH measuring and control unit 813 mm x 722 mm x 286 mm (for details see dimensional drawings)
Weight
FWE200DH measuring and control unit: 65 kg
Sampling probe: ≤ 15 kg
Material in contact with media PVDF, Hastelloy

Energy supply
Voltage 115 V AC
230 V AC

2024-04-22 21:20:32 | Product data sheet DUST MEASURING DEVICES | SICK 3



Subject to change without notice
System FWE200DH | FWE200DH
DUST MEASURING DEVICES

A Frequency 50 Hz / 60 Hz
Power consumption FWE200DH measuring and control unit: 800 VA ... 1,700 VA
Air heater: ≤ 1,000 VA

B
Sample gas line, heated: ≤ 300 VA
Test functions Automated self-test (zero point, contamination, drift)
Contamination limit values: Warning at 30%; fault at 40%

C
Manual linearity test with reference filter
Options FWE200DH mounting rack
Air backwash
Water backwash

D Sample gas line, heated


Air heater

E
Classifications
ECLASS 5.0 27150306

F
ECLASS 5.1.4 27150306

ECLASS 6.0 27150306

ECLASS 6.2 27150306

ECLASS 7.0 27150306

ECLASS 8.0 27150306

H ECLASS 8.1
ECLASS 9.0
27150306

27150306

I ECLASS 10.0
ECLASS 11.0
27150306

27150306

ECLASS 12.0 27150306

J ETIM 5.0 EC001190

ETIM 6.0 EC001190

K ETIM 7.0
ETIM 8.0
EC001190

EC001190

L UNSPSC 16.0901 41115406

M
N
O
P
Q
R
S
T 4 DUST MEASURING DEVICES | SICK Product data sheet | 2024-04-22 21:20:32
Subject to change without notice
System FWE200DH | FWE200DH
DUST MEASURING DEVICES

Dimensional drawing (Dimensions in mm (inch))


FWE200DH measuring and control unit

813 (32.01)
783 (30.83)
78 (3.07) 650 (25.59) 85 (3.35) 286 (11.26)

42 (1.65)
722 (28.43)
650 (25.59)
30 (1.18)

Ø 14 (0.55)

Sampling probe

600/1.200 (23.62/47.24)
250/850
140 (9.84/33.46)
(5.51)
.8 0
(7 2 0
7)
Ø
Ø 32 (1.26)

Ø 14/18/23
Ø 50 (1.97)

(.55/.71/.91)
Ø
24 5)
(9

0
. 4

2024-04-22 21:20:32 | Product data sheet DUST MEASURING DEVICES | SICK 5



Subject to change without notice
System FWE200DH | FWE200DH
DUST MEASURING DEVICES

A FWE200DH remote control unit

210 (8.27)

B
160 (6.30) 120 (4.72)

C
340 (13.39)
320 (12.60)
300 (11.81)

D
Meas

E
F Ø 8 (.31)

SLV7-1 purge air unit, 2BH1100, 1-ph

H Ø 14
(0.55)

I
585 (23.03)
470 (18.50)

J
K
L
M 470 (18.50)
550 (21.65)
250 (9.84)

N
O
P
Q
R
S
T 6 DUST MEASURING DEVICES | SICK Product data sheet | 2024-04-22 21:20:32
Subject to change without notice
System FWE200DH | FWE200DH
DUST MEASURING DEVICES

FWE200DH mounting rack


650 (25.59)

1.970 (77.56)

1.855 (73.03)
650 (25.59)

470 (18.50)
1.180 (46.46)

92
0(
470 (18.50)

36
.22
)
(6.30)
160

1.000 (39.37)

Ø 15 (0.59)
500 (19.69)

450 (17.72)

800 (31.50)

2024-04-22 21:20:32 | Product data sheet DUST MEASURING DEVICES | SICK 7



Subject to change without notice
SICK at a glance
Online data sheet

SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica-
tions. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.

We have extensive experience in a wide range of industries and understand their processes and require-
ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.

Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the ma-
chine life cycle and ensure safety and productivity.

For us, that is “Sensor Intelligence.”

Worldwide presence:
Contacts and other locations – www.sick.com

SICK AG | Waldkirch | Germany | www.sick.com

You might also like