gsd [Administrator (2000)] General Overview 14/03/2016 11:03

FROM NATURAL
GAS PIPELINE

Cyclones and Coalescer Filters Flow Metering Gas Preheating Pressure Reduction

ESD Conditions

2oo3 inlet pressure transmitter low/high


12.52 52.97 12.59 52.94
Digital input DCS ESD dropped °C bar g °C bar g
0.0
0.39 Sm³/h TT PT TT PT 14.42 52.94 52.98 13.91 33.38 17.72
Filter or cyclone level highhigh GC
mbar °C bar g bar g °C bar g °C
ESD

Fire alarm 98.37 8.42


DP TT PT PT TT % % PT TT

RCV

RCV
ESD ACTIVE

PT
52.98 0.17
bar g mbar 52.94 14.05 33.38 17.57
LCV TT 13.91 TT 10.94 bar g °C bar g °C
DP
PT
52.91 °C °C 100.00 -0.91 TO GAS
bar g PT TT % % PT TT TURBINES

PT 52.94
bar g
LCV

TT 19.51 0.17 53.05 15.69 33.38 17.95


°C mbar bar g °C bar g °C
-0.19 0.61
DP PT TT % % PT TT

52.98 16.16 33.38 18.56


LCV bar g °C bar g °C
General Alarm General Alarm 0.61 -0.08
Condensate Installation Stopped Installation Stopped PT TT % % PT TT
Water level low/low Water level low/low
Water level low Water level low
Gas Fault Gas Fault

DCS Permissive
Flowrate too low

Home Network Filters Metering Pressure Reduction Alarm Summary Trending Reports Help
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
gsd [Administrator (2000)] Network 14/03/2016 11:03

Launch Explorer

Supervisory computer

LAN A
LAN B

FIBER DCS Link A

FIBER DCS Link B

PLC A

PLC B
Flow computer

FT00EKD30CF001

Home Network Filters Metering Pressure Reduction Alarm Summary Trending Reports Help
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
gsd [Administrator (2000)] Cyclones and Coalescer Filters 14/03/2016 11:03

ESD Conditions Reset ESD

FROM NATURAL 2oo3 inlet pressure transmitter low/high


GAS PIPELINE
Digital input DCS ESD dropped

Filter or cyclone level highhigh


FILTER
Fire alarm 00EKA21CP001
0.39
Flow Metering
ESD ACTIVE mbar 00EKA21AA004
00EKA10AA001
DP

00EKA10AA002 CYCLONE

00EKA11AA004 00EKA21AA001 00EKA21CL001


00EKA11CP001 0.46
00EKA10AA201 00EKA10AA010 0.17 %
ESD

mbar
00EKA12AA004 00EKA21AA201
DP A
LCV
00EKA10AA003
00EKA11CL001
6.00
%
00EKA11AA001
00EKA11AA201
00EKA10CP001 00EKA10CP002 00EKA10CP003 00EKA10CT001 A
LCV
52.98 52.91 52.94 19.51
bar g bar g bar g °C

PT PT PT TT
00EKA12AA001 FILTER
00EKA22CP001
0.17
mbar 00EKA22AA004

DP

00EKA22AA001 00EKA22CL001
15.26
%

00EKA22AA201
A
LCV

Condensate

00EKR10AP001

00EKR10CL001
100.00
%

Home Network Filters Metering Pressure Reduction Alarm Summary Trending Reports Help
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
gsd [Administrator (2000)] Flow Metering 14/03/2016 11:03

00EKD30CT001 00EKD30CP001
12.52 52.97
00EKD30CF001 °C bar g
0.0
Sm³/h TT PT Gas Preheating
Cyclones and Coalescer Filters 00EKD30AA001 00EKD30AA004 And Pressure Reduction

GC

Current Values 00EKD30CQ001


N2 % 1.11657
Current Values 00EKD30CF001
00EKD31AA001 CO2 % 1.39856
Gross Volume m³/h 0.0 H2S % 0.00000
Standard Volume Sm³/h 0.0 H2O % 0.00000
Mass t/h 0.0 He % 0.00000
Energy GJ/h 0.0 C1 % 88.53772
C2 % 7.72679
Pressure bar g 52.97 C3 % 1.00405
Temperature °C 12.52 nC4 % 0.09142
Heating value MJ/Sm³ 39.78 iC4 % 0.07885
nC5 % 0.01021
iC5 % 0.01956
Current Hour 00EKD30CF001
neoC5 % 0.00000
Gross Volume m³ 0 nC6 % 0.00000
Standard Volume Sm³ 0 00EKD32AA001 00EKD32AA004 nC7 % 0.00000
Mass t 0 nC8 % 0.00000
FutureFM 0.00000
Energy GJ 0 nC9 %
nC10 % 0.00000
O2 % 0.00000
Previous Hour 00EKD30CF001
CO % 0.00000
Gross Volume m³ 0 Hydrogen % 0.00000
Standard Volume Sm³ 0 Benzene % 0.00000
Mass t 0 Toluene % 0.00000
Energy GJ 0 Argon % 0.00000
C6plus % 0.01627
Cxplus % 0.00000
Current Day 00EKD30CF001
Gross Volume m³ 0 Heating value MJ/Sm³ 39.782
Standard Volume Sm³ 3
Mass t 0
Energy GJ 0
Status 00EKD30CQ001
0 Communication status
Previous Day 00EKD30CF001
1 Normal condition
Gross Volume m³ 2598 0 Response factor error
Standard Volume Sm³ 165274 0 Total raw concentration out of limits
Mass t 126 0 RAM error
Energy GJ 6579 0 Retention time error
0 CPU communication error
0 Timer error
Cumulative 00EKD30CF001
0 Battery exchange needed
Gross Volume m³ 50677 0 HGC no response
Standard Volume Sm³ 550032 0 HGC overhaul time
Mass t 410 0 Chromatograph peak height over the measurement range
Energy GJ 21587 0 Carrier gas pressure out of control
0 Oven temperature error
0 Chromatograph baseline error
0 Carrier gas pressure error
0 Oven temperature extremely high
0 HGC data bad

Home Network Filters Metering Pressure Reduction Alarm Summary Trending Reports Help
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
gsd [Administrator (2000)] Gas Preheating And Pressure Reduction 14/03/2016 11:03

Gas Preheating Pressure Reduction

00EKD34CT001 00EKD34CP001
12.59 52.94
0.0 °C bar g
Sm³/h
TT PT
Flow Metering
00EKD40CT001 00EKD40CP001 00EKD41CP001 00EKD41CT001 00EKD41CP002 00EKD41CT002
14.42 52.94 52.98 13.91 00EKD41AA202 00EKD41AA203 33.38 17.72
°C bar g bar g °C 98.37 8.42 bar g °C
00EKD35AA001 00EKD33AA001 00EKD34AA001 00EKD41AA201 % %
RCV

RCV
A A
TT PT PT TT 00EKD41AA001 00EKD41AA004 PT TT

00EKD33AA004 00EKD34AA004

00EKD42CP001 00EKD42CT001 00EKD42CP002 00EKD42CT002


52.94 14.05 00EKD42AA20200EKD42AA203 33.38 17.57
TT TT bar g °C 100.00 -0.91 bar g °C
00EKD42AA201 % % TO GAS
00EKD33CT001 00EKD34CT002 PT TT 00EKD42AA001 00EKD42AA004 PT TT TURBINES
13.91 10.94
°C °C

00EKD43CP001 00EKD43CT001 00EKD43CP002 00EKD43CT002


53.05 15.69 00EKD43AA20200EKD43AA203 33.38 17.95
bar g °C -0.19 0.61 bar g °C
00EKD43AA201 % %
PT TT 00EKD43AA001 00EKD43AA004 PT TT

A A

D S

General Alarm General Alarm 00EKD44CP001 00EKD44CT001 00EKD44CP002 00EKD44CT002


Installation Stopped Installation Stopped 52.98 16.16 00EKD44AA20200EKD44AA203 33.38 18.56
Water level low/low Water level low/low bar g °C 0.61 -0.08 bar g °C
Water level low Water level low 00EKD44AA201 % %
Gas Fault Gas Fault PT TT 00EKD44AA001 00EKD44AA004 PT TT

DCS Permissive
Flowrate too low

Home Network Filters Metering Pressure Reduction Alarm Summary Trending Reports Help
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
gsd [Administrator (2000)] Alarms and Events 14/03/2016 11:03

Alarms Summary Alarm and event history


1
05/02/2016 0:00 ▼ 06/02/2016 0:00 ▼

Home Network Filters Metering Pressure Reduction Alarm Summary Trending Reports Help
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
gsd [Administrator (2000)] Trending 14/03/2016 11:03

1 1

Home Network Filters Metering Pressure Reduction Alarm Summary Trending Reports Help
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
gsd [Administrator (2000)] Help and legend 14/03/2016 11:03

status indication that application is running

Valve symbols Alarm colors Comments

ALARM Unacknowledged active alarm dd/mm/yyyy hh:mm User Comment


Remote controlled valve ALARM Acknowledged active alarm
ALARM Unacknowledged inactive alarm

Hand operated valve Pipelines

Pipeline without flow


Pressure control valve
Pipeline with condensate flow

Pipeline with gas flow

Valve positions Transmitter status

Open Error No communication

Closed Healthy
No feedback
Travelling FC offline Alarm

Transmitter failure 0
M Manual operation mode
Override active
A Automatic operatıon mode

Transmitter description

PT Pressure transmitter
TT Temperature transmitter
FT Flow transmitter

Flow meter types

Ultrasonic meter