UNCONFINED COMPRESSION TEST


(ASTM D-2166-06 : 2012)

Tabel III.4 Unconfined compression test of undisturb


No. Water Content Testing
1 Weight of Cup (W1) 6,16 gram
2 Weight of cup + dry soil (W2) 9,23 gram
3 Weight of cup + wet soil (W3) 12,142 gram
4 Weight of water 2,912 gram
5 Weight of dry soil 3,07 gram
6 Water Content 94,85 %

UNDISTURB Calibration = 0,347860 kg/div


Strain Cross-Sectional Beban Teg.
ΔL = ε= Area Pembc. Beban
P/A
No Reads. (a) x 10-3 ( ΔL / L0) x 100% A= Arloji P
(cm) (%) A0 / (1 - ε ) (div) (kg) (kg/cm²)
(a) (b) (c) (d) (e) (f) (g)
1 15,00 0,02 0,22 9,09 2,00 0,70 0,08
2 18,00 0,02 0,27 9,10 5,00 1,74 0,19
3 21,00 0,02 0,31 9,10 9,00 3,13 0,34
4 55,00 0,06 0,82 9,15 14,00 4,87 0,53
5 85,00 0,09 1,27 9,19 16,00 5,57 0,61
6 118,00 0,12 1,76 9,24 20,00 6,96 0,75
7 151,00 0,15 2,25 9,28 23,00 8,00 0,86
8 181,00 0,18 2,70 9,33 26,00 9,04 0,97
9 213,00 0,21 3,18 9,37 28,00 9,74 1,04
10 252,00 0,25 3,76 9,43 28,00 9,74 1,03
11 277,00 0,28 4,13 9,47 29,00 10,09 1,07
12 314,00 0,31 4,69 9,52 29,00 10,09 1,06
13 335,00 0,34 5,00 9,55 28,00 9,74 1,02
14 354,00 0,35 5,28 9,58 27,00 9,39 0,98