TA3551ci Charge Roller Replacement

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

2L6/2N6/2N5/2N4-1

1-5-5 Image formation section


(1) Detaching and refitting the inner unit

Procedure
1. Open the front cover.
2. Remove all toner container each.
3. Remove the waste toner box tray by lift-
ing upwards and from the right side.

Figure 1-5-91

4. Remove the screw and then open the


connector cover.
5. Remove the connector.
*: Remove the seal behind that connector
is recessed.
6. Remove four fixed screws of inner unit.
*: Remove the seal behind that one screw
is recessed.
Replace the seal in position.

Figure 1-5-92

1-5-55
2L6/2N6/2N5/2N4

7. Release the lock by pushing the fixed


levers at the right and left of inner unit.
8. Remove the inner unit.

Figure 1-5-93

1-5-56
2L6/2N6/2N5/2N4

(2) Detaching and refitting the developer unit and drum unit

Detaching example: Developer unit Y and Drum unit Y

Procedure
1. Remove the fuser unit (see page 1-5-
68).
2. Pull the transfer belt unit out a little (see
page 1-5-62).
3. Remove the inner unit (see page 1-5-
55).
4. Close the toner supply shutter.
5. Remove two connectors.

Figure 1-5-94

6. Pull out as one body the developer unit


and the drum unit.
(The developer unit becomes basic and
the drum units are combined.)
7. Detach the developer unit while sup-
porting bottom.

Figure 1-5-95

1-5-57
2L6/2N6/2N5/2N4-4

8. Remove the drum unit from the devel-


oper unit.
9. Check or replace the drum unit and the
developer unit and refit all the removed
parts.
*: When a new development unit is
installed, the developing roller protec-
tive sheet must be removed. Developer roller
*: To install the drum unit onto the devel- protection seat
oper unit, insert the front end first, then
the rear end of the unit.

Figure 1-5-96

10. When replacing the new developer unit,


proceed as follows:
1)Perform maintenance mode U140
(AC calibration) for 45 ppm/55 ppm
model only (see page 1-3-99).
2)Perform maintenance mode U464
(Calibration) (see page 1-3-197).
3)Perform maintenance mode U469
(Auto color registration correction)
(see page 1-3-204).
4)Perform maintenance mode U410
(Adjusting the halftone automatically)
(see page 1-3-172).

Figure 1-5-97

11. When replacing the new drum unit, proceed as follows:


1)Performing LSU cleaning (see the operation guide)
Press [Adjustment/Maintenance] and then [Next] of [Laser Scanner Cleaning].
Press [Execute] to perform LSU cleaning.
2)Perform maintenance mode U119 (drum setup) (see page 1-3-92).
3)Perform maintenance mode U930 (checking/clearing the charger roller count) and checking the
counter value (see page 1-3-229).
4)Perform maintenance mode U140 (AC calibration) for 45 ppm/55 ppm model only (see page 1-3-99).
5)Perform maintenance mode U464 (Calibration) (see page 1-3-197).
6)Perform maintenance mode U469 (Auto color registration correction) (see page 1-3-204).
7)Perform maintenance mode U412 (Adjusting the uneven density) (see page 1-3-182).
8)Perform maintenance mode U464 (Calibration) (see page 1-3-197).
9)Perform maintenance mode U410 (Adjusting the halftone automatically) (see page 1-3-172).

1-5-58
2L6/2N6/2N5/2N4

(3) Detaching and refitting the charger roller unit


Detaching example: Charger roller unit Y

Procedure
1. Remove the inner unit (see page 1-5-
55).
2. Pull out the charger roller unit by pick-
ing and releasing the MC lock lever.
3. Check or replace the charger roller unit
and refit all the removed parts.

*: When refitting the charger roller unit,


that must hook the hook certain by
operating the MC lock lever after insert-
ing the charger roller unit until bumping.

4. When replacing the new charger roller


unit, proceed as follows:
Perform maintenance mode U930
(clearing the charger roller count) (see
page 1-3-229).
Perform maintenance mode U464 (Cali-
bration) (see page 1-3-197).
Perform maintenance mode U410 (Adjust-
ing the halftone automatically) (see page1-
3-172).

Figure 1-5-98

1-5-59