FAN FILTER UNIT

www.mayairgroup.com
ABOUT MAYAIR
MayAir Group, a global leading manufacturer, developer and service provider
of air purification equipment and clean air solutions, was established since
2001. The company specializes in air filtration research and development,
design and onstruction, production, distribution, installation and service
maintenance of clean air solutions for industrial, commercial and residential
sectors.

Historically, the group’s core business has been focused in providing HVAC COMPANY SALES
filters, fan filter units (FFUs) and air filtering equipment for the uses in
EMPLOYEES OFFICES
industrial cleanrooms, making it one of the global leading providers in this
field. With a team of a few hundreds world-class engineers, MayAir has
established as one of the pioneers in air filtration product manufacturing,
operating multiple manufacturing plants across the globe. With strong
foundations and successful achievements in the air filtration industry across
Asia, the company is rapidly expanding into the United States, Europe,
Middle East, and other parts of the world.

With over 20 years of experience and continuous breakthroughs, MayAir


has proven itself as a highly reliable air filtration company and developer
of effective air filtration equipment and clean air solutions. It possesses
the capability to offer a full spectrum of clean air solutions to various
business segments, particularly in cleanrooms for the semiconductor, MANUFACTURING R&D
pharmaceutical, data centre, power plant, electrical and electronic and BASES CENTERS
biomedical industries, and others.

1
DIVERSIFIED PRODUCT RANGES & COMPREHENSIVE SOLUTIONS
APPLICATIONS

Semiconductor Pharmaceutical Automobile Residential

Industrial Healthcare Facilities Data Center Commercial Kitchen

Airport Metal Processing Museum Commercial Building

Power Plant Paper Pulp Railway Tunnel

2
IN-HOUSE STATE OF THE ART R&D CAPABILITY
MayAir Testing Centre is a CNAS-accredited test center in accordance with ISO/IEC 17025:2017 General
Requirements for Competence of Testing and Calibration Laboratories. The testing center is well- equipped
with a full range of testing facilities to carry out comprehensive FFU performance tests.

MayAir in-house R&D team utilises Computational Fluid Dynamic (CFD) for its product development to
ensure optimized airflow within FFU housing. With the technology in place, MayAir FFUs able to deliver
maximum output of air with minimal static losses and noise generation, where the average airflow velocity
for the filter is controlled within uniformity of <10%.

Air Velocity Distribution 3D Diagram

ABOUT MAYAIR FAN FILTER UNIT DYNAMICALLY - BALANCEDFAN


Fan Filter Units (FFUs) are meticulously engineered to maintain pristine MOTOR FOR PROLONGED
air quality by effectively filtering and circulating air within a defined space.
FFU is generally comprised of a metal housing with blower within, together SERVICE LIFE
with a high-efficiency particulate air (HEPA) or ultra-low penetration air
MayAir FFU fan motor assembly is tested and dynamically-balanced
in
(ULPA) filter, which efficiently removes airborne contaminants, such as
accordance to the international standard known as ISO1940 - Mechanical
dust, particles and microorganisms.
Vibration, with balancing criteria refined up to class G2.5. Technically, a
statically and dynamically-balanced FFU fan motor assembly can effectively
FFUs play a crucial role in sustaining controlled environments by ensuring
reduce unbalanced force loading on the FFU bearing and increase the
consistent air cleanliness and airflow. MayAir FFU fan systems are
service lifespan of FFU. With this, MayAir’s FFUs boast significant impacts
engineered to deliver a uniform and consistent flow of filtered air, helping
in service and replacement costs reduction.
to create and maintain the required cleanliness standards in the most
demanding and sensitive applications. MayAir FFUs are the go-to choice
for maintaining the highest levels of air quality and cleanliness in critical
workspaces, makingthem an essential component in numerous industries
where air purity is paramount.

3
PROMOTE ENERGY SAVING & HIGH-LEVEL
REDUCE ENVIRONMENTAL OPERATIONAL
IMPACTS CONTROL SYSTEM
MayAir is actively involved in reducing the world's carbon footprint by MayAir FFUs control system can be centralized and synchronized with the
adopting energy-saving technology within its product design. By utilizing Building Management System (BMS). By utilizing Flonet, a unique software
EC motor technology, MayAir achieves significantly higher operational developed by our in-house R&D, a large number of FFUs can be monitored
efficiency when compared to conventional AC systems. MayAir's FFUs and controlled in real-time. The system can be synchronized with the
boast unparalleled energy efficiency, resulting in savings of up to 80% building's other services, such as the fire alarm system. In the event of a fire,
when compared to AC technology, and with an overall FFU fan efficiency the FFUs in the affected zone will shut down without affecting other floors
exceeding 60%. This not only extends the service life but also reduces noise or areas. This could ensure optimal safety during evacuation procedures.
levels, making it the quietest FFU in the industry.

REMARKABLE CRAFTSMANSHIP
MayAir Testing and Calibration Laboratories are fully-equipped with MayAir FFUs offer clients the flexibility to choose the materials and sizes
advanced testing equipment and platforms, complemented with the tailored to their project applications. In addition to the standard sizes,MayAir
integration of cutting-edge R&D technology. Our testing standards are can also design and fabricate custom sizes for clients based ontheir needs.
aligned and accreditated with ISO 5801:1997 (Industrial Fans - Performance The appearance of our FFUs is sleek, ensuring minimal dustaccumulation
Testing Using Standardized Airways). and making them the ideal choice for all cleanroom applications. The FFUs
are user-friendly for both installation and maintenance, with a design
Within our well-equipped and competent laboratories, we conduct focused on prioritizing ease of use for the clients.
comprehensive FFU testing, examining parameters such as airflow, pressure,
motor RPM, efficiency and power. It is within these testing facilities that Through all the unwavering dedication and relentless efforts, MayAir FFUs
exceptional FFU designs are conceived, offering innovative solutions to the meet and exceed most international standards, including but not limited to
market. UL, CE and UKCA.

HASSLE - FREE  AIRBORNE MOLECULAR


INSTALLATION  CONTAMINATION (AMC)
AND MAINTENANCE RISK MANAGEMENT
MayAir's FFU design offers clients an enhanced level of simplicity during In precision environments, the presence of molecular-level air contamination
installation and maintenance. In the life science industry, FFU filters can can compromise the integrity of ongoing operations, leading to equipment
be replaced on the room side without the needs of special tools. In the corrosion and an elevated process failure rate. MayAir FFUs are purpose-
electronics industry, both of MayAir’s filters and FFUs can be replaced
 built to accommodate AMC pre-filters, to filter out target contaminants
and installed either from the bottom or top, depending on the actual before the air is distributed to the room. Coupled with the highly
site conditions. Recognizing the limitations of ceiling space, MayAir has effective HEPA and ULPA filters, this system ensures airborne molecular
developed a slimmer type of similar equipment, known as Equipment Filter contamination (AMC) can be well-managed within manufacturing facilities.
Unit (EFU), to address such scenarios. This provides clients with improved
solutions and hassle-free maintenance options for their applications.

4
MICROELECTRONICS CLEANROOM
MayAir's Fan Filter Unit (FFU) is specially designed for cleanrooms in
the microelectronics industry. The FFU housing can be customized with
materials like galvalume, stainless steel or aluminum, based on the client's
preferences. In microelectronic cleanrooms, MayAir offers several FFU
models, including Bottom-Load, Top-Load, and the Slim Type/ Low Profile
FFU and Equipment Filter Unit, EFU.

MayAir FFUs present optimal solutions for enhancing air quality in the
most demanding cleanroom environments in accordance to the cleanroom
class as per ISO 14644 and/ or Federal Standard FS 209E.

CROSS-SECTIONAL VIEW OF MAYAIR FFU

Bottom Load Expandable Rod

Lightweight Housing

HEPA / ULPA Filter

AC / EC Motpr

ISO 14644 & FS 209E CLEANROOM CLASS TABLE

MayAir FFUs deliver significant cost savings and electrical efficiency, particularly in large cleanrooms. The housing forms a tight seal and supports the anodised
aluminium framed HEPA or ULPA filters to ensure the delivery of clean air to the manufacturing processes.

MAXIMUM PARTICLES PER M3 (PER PARTICLE SIZE SHOWN BELOW)


ISO CLASS FEDERAL STANDARD
ISO 14644 FS 209E ≥ 0.1 μm ≥ 0.2 μm ≥ 0.3 μm ≥ 0.5 μm ≥ 1.0 μm ≥ 5.0 μm

ISO 1 10

ISO 2 100 24 10 4

ISO 3 Class 1 1,000 237 102 35 8

ISO 4 Class 10 10,000 2,370 1,020 352 83

ISO 5 Class 100 100,000 23,700 10,200 3,520 832 29

ISO 6 Class 1,000 1,000,000 237,000 102,00 35,200 8,320 293

ISO 7 Class 10,000 352,000 83,200 2,930

ISO 8 Class 100,000 3,520,000 832,000 29,300

ISO 9 35,200,000 8,320,000 293,000

5
APPLICATIONS DESIGN FEATURES & BENEFITS

- Installation and maintenance from the room/ plenum side


- Reduced manpower requirements
- Simplified maintenance procedures
- Compatible with all MayAir HEPA & ULPA Filters
- Low noise level with enhanced efficiency
- Appropriate for all ISO cleanroom classes
Semiconductor manufacturing Medical device manufacturing
- Optional MayAir in-house centralized control software, Flonet
(Suitable for large scale cleanroom)
- Optional MayAir in-house touchscreen control
- (Suitable for small scale cleanroom)
- Optional MayAir in-house wireless control system
(Suitable for both large & small scale cleanroom)

Other regulated and - Can synchronize with the Building Management System (BMS)
Microelectronic manufacturing
controlled environments

FAN FILTER UNIT STRUCTURE 1 2

The FFUs can be serviced from either the top side or the bottom side,
providing flexibility in application design and access. MayAir FFUs have
high static pressure sufficient to overcome and accommodate pressure
losses contributed by the HEPA/ ULPA filters, return air grilles, raised floor
systems and etc.

The MayAir FFU is primarily comprised of the 1. housing and a durable


2. AC/ EC motor. This FFU collaborates with integrated components such
as 3. M-HII, 4. M-UII and other compatible filters to enhance the uniformity
of airflow and provide clean air to the room.

The following additional accessories are available: 3, 4 6, 7


- 5. Pre-filter for coarse particle filtration.
Side View (with AMC Filter)
- 6. Buffer frame with 7. AMC Filter
- Bottom load extension rod
- Heat exchanger integrated unit
- Pressure gauge 1 5
- Pressure test port
- Heat insulation
- Inlet colar with damper
- Noise insulation

3, 4 2

Side View (with Pre-Filter)


1 2 6, 7

3, 4
Cross-Sectional View (with AMC Filter) Top View

6
PHARMACEUTICAL & LIFE SCIENCE
MayAir's Fan Filter Unit (FFU) is specifically tailored for cleanrooms in the
lifescience industry. The FFU housing can be customized with materials such
aspowder-coated steel, stainless steel or aluminum, catering to the client's
preferences. When employed in life science cleanrooms, MayAir offers FFU

models designed with room-side access.

MayAir FFUs provide ideal solutions for elevating air quality in the most rigorous
cleanroom environments to meet the cGMP Cleanroom Class A, B, C and D.
MayAir FFUs bring substantial cost savings and electrical efficiency, p
 articularly
beneficial in expansive cleanrooms. The housing creates anairtight seal with
HEPA/ ULPA filters to ensure the safe delivery of clean airto the manufacturing
processes specific to life science applications.

CROSS-SECTIONAL VIEW OF MAYAIR FFU

Optional Inlet Collar PAO Injection/ Test Port


HEPA Pressure Port

Lightweight Housing
Gel Sealed HEPA Filter

FFU Housing Knife-Efdge Design

AC/ EC Motor

cGMP CLEANROOM CLASS TABLE

DESCRIPTION AREA CLASSIFICATION

CRITERIA PARTICLE SIZE GRADE A GRADE B GRADE C GRADE D

ISO 8 AT REST
LIMITED TYPE ISO 5 AT REST ISO 5 AT REST ISO 7 AT REST
NO LIMIT IN
N/A N/A / ISO 5 IN / ISO 7 IN / ISO 8 IN
OPERATION BY
OPERATION OPERATION OPERATION
REGULATION

Maximum Number of Particles 0.5 μm 3,520 3,520 352,000 3,520,000


At
Per m3
Airbone Rest
>the Stated Size 5 μm N/A N/A 2,930 29,300
Particulate
Limits Maximum Number of Particles 0.5 μm 3,520 352,000 3,520,000 -
In
Per m3
Operation
>the Stated Size 5 μm N/A 2,930 29,300 -

Maximum Permitted Number of


Viable Organisms cfu/m3 - <1 10 100 200
Micro Air In (EU/Canada)
Limits Operation Maximum Permitted Number of
Viable Organisms cfu/m3 - 1 7 10 100
(USA)

7
APPLICATIONS DESIGN FEATURES & BENEFITS

- Installation and maintenance from the room/ plenum side


- Enhanced efficiency
- Reduced manpower requirements
- Simplified maintenance procedures
- Compatible with all MayAir HEPA & ULPA Filters
- Appropriate for all ISO cleanroom classes
Pharmaceutical processing Sterile compounding pharmacies
- Low noise level
- MayAir in-house centralized control software, Flonet
(Suitable for large scale cleanroom)
- MayAir in-house touchscreen control
(Suitable for small scale cleanroom)
- MayAir in-house wireless control system
Hazardous drug or (Suitable for large & small scale cleanroom)
Hospitals & diagnostic centre
material handling - Synchronized with the Building Management System (BMS)

FAN FILTER UNIT STRUCTURE 1 2 5, 6

In the highly regulated realm of pharmaceutical cleanrooms, ensuring the


utmost air quality stands as a paramount necessity. MayAir's Fan Filter Units
(FFUs) assume a pivotal role in upholding this immaculate environment.
These FFUs are thoughtfully engineered to facilitate easy in-room
replacement, addressing the unique requirements of the pharmaceutical
industry.

Pharmaceutical cleanrooms must adhere to the rigorous standards of


ISO classifications. The inclusion of flush surfaces, characterized bytheir

absence of protrusions, ledges, or recesses, simplifies the tasks ofcleaning, 4 7, 8
decontamination and maintenance within these controlled
environments.
Side View
These smooth surfaces prevent the accumulation of
contaminants, thus
making it more attainable to consistently meet and
uphold the essential
cleanroom standards.

MayAir's FFU is primarily comprised of the 1. Housing and a durable


2. AC/ EC Motor that can be replaced from the room. The FFU features a
3. Flush Perforated grill to comply with cGMP stringent requirements. The
4. Knife-edge feature in the FFU, along with the special integrated gel-
sealed 5. M-HII-GS-PAO and 6. M-UII-GS-PAO filters, creates an airtight seal
that eliminates any air leakage. Additionally, the FFU boasts an 7. Upstream
Test Port and an 8. Injection Dust Port for Poly Alpha Olefin (PAO) testing,
ensuring that the cleanroom adheres to cGMP (current Good Manufacturing
Practices). 9. Self-Suspending brackets are also available for M10 threaded
rod ceiling mount application.

9
The following additional accessories are available: Top View

- Pre-filter for coarse particle airborne before FFU


- Pressure gauge
- Heat insulation
- Inlet collar c/w damper
- Optional swirl diffuser

Bottom View

8
MAYAIR FFU CONTROL SYSTEM
CONFIGURATION FLONET
The MayAir Flonet system is well-suited for efficiently managing a clean
room of any sizes and able to control both AC and EC type of FFUs.

It offers real-time monitoring and can handle up to 50,000 units within


a single system. This system is versatile, allowing control over the entire
building's cleanroom, including separate zones with varying ISO classes.
It utilizes a TCP/IP network for signal transmission at speeds of up to
100Mbps, with the option for fiber optic configuration. The system exhibits
exceptional stability and response times, with synchronous FFU group
scanning taking less than 15 seconds per cycle, and it continues to operate
seamlessly even in the event of a lost connection to the server or PC.

MayAir places a strong emphasis on security and has developed a


multi-level a
 dministration system for control and monitoring. Users receive
a unique registration key for software commissioning. User-friendliness is a
top priority in the software's design, featuring a clear navigation tree and
a display of theactual cleanroom layout. This ensures users have a more
efficient and straight f orward experience when monitoring FFUs within the
cleanroom.

MAYAIR FLONET FFU GROUP CONTROL SYSTEM

BMS/ Third Party System for


High Level Interface

TCP/IP
Ethernet Switches

Gateway Gateway Gateway


I/O Module

Group 1 Group 8 Group 9 Group 16 Group 17 Group N

FFU 1 FFU 1 FFU 1 FFU 1 FFU 1 FFU 1


RS-485

FFU 2 FFU 2 FFU 2 FFU 2 FFU 2 FFU 2

FFU 31 FFU 31 FFU 31 FFU 31 FFU 31 FFU 31

1. CAT5e/ CAT6 cable is utilised for RS-485 signal transmission.


2. Typically, the network cable length between TCP Devices is <100m. For the cases of >100m, optical transmission shall be utilised instead.
3. The network cable length between Serial Server port to Last FFU (RS-485) should be <800m.
4. Each groups of FFU is daisy-chained up to 31 FFUs to gateway-serial device servers. Each gateway can connect up to 8 groups of FFUs.
The serial device servers are properly assigned into FFU control panels according to the project size and layout. The serial device servers are all
connected within the same network via ethernet switches. With special request, IO Module can be added into the system network for fire alarm signal
input and/ or FFU fault alarm signal output.
5. Optional high level interface with third party BMS can be achieved via TCP/Modbus. This allows for the extraction of information such as the FFU's
online/offline status, run/ stop status, normal/ faulty status, and running RPM via FFU control system. This provides greater convenience for the client's
facility team, allowing them to monitor all the services in their FM system more effectively.

9
WIRELESS CONTROL SYSTEM
Wireless (Frequency, Hz)
MayAir offers a cutting-edge wireless control system
for our clients, providing cost savings for FFU setups.
This system utilizes IP addresses and frequency bands
to control and monitor FFUs in the cleanroom. With this
Wireless Gateway
technology, network cabling work is significantly reduced
and this subsequently leads to reduced material, labour
and maintenance cost in a long run.

Wireless Gateway
TCP/IP

Ethernet Switches

Wireless Gateway

OPTIONAL OPEN PROTOCOL MODBUS COMMUNICATION

PLC

TCO/ Modbus
Ethernet Switches

Converter Converter Converter

FFU 1
FFU 1
FFU 1 FFU 1 FFU 1 FFU 1 FFU 1 FFU 1

FFU 2
FFU 2

FFU 2 FFU 2 FFU 2 FFU 2 FFU 2 FFU 2

FFU 31
FFU 31

FFU 31 FFU 31 FFU 31 FFU 31 FFU 31 FFU 31

MayAir also provides optional Open Protocol Modbus communication (TCP Modbus or Modbus-RTU) for third party BMS to perform full control and monitoring
of MayAir FFU directly without MayAir FLONET control system. In this case, the Flonet software is not applicable, and the monitoring and control software will
be done by the third party. All FFU parameters can be controlled and monitored will be shown within this configuration system.

10
OPTIONAL CONTROL SYSTEM TOUCH SCREEN PANEL –
FOR SMALLER SCALE CLEANROOM
In addition to Flonet, MayAir offers optional features for clients, particularly
those with small-scale cleanrooms. The Touchscreen Control Panel is ideal Group 1
for small cleanroom setups, capable of controlling up to 4 groups of FFUs,
totalling 132 units. The FFU layout can be programmed into an HMI for real- FFU 1 FFU 2 FFU 3 FFU 31
time location monitoring. With this standalone control system, clients can
seamlessly integrate it into their existing setup without any additional work.
It's a fast and convenient solution for cleanroom construction.
Group 2
Optional feature for interfacing with BMS Fire Alarm and additional FFU
units quantity to be monitored under single system is available upon request. FFU 1 FFU 2 FFU 3 FFU 31
Touch screen panel for single group or multiple FFUs for local control is
also available.

Group 3

FFU 1 FFU 2 FFU 3 FFU 31

Group 4

FFU 1 FFU 2 FFU 3 FFU 31

MAYAIR FLONET CONTROL SYSTEM INTERFACE HIGHLIGHTS

1. Display of the actual cleanroom layout; 1. Real-time FFU status updates;


2. Support for multiple zoning layouts; 2. Ability to check individual status by hovering the mouse over;
3. User-friendly and straightforward. 3. Monitoring and controlling the status of multiple FFUs or groups.

1. Operation and alarm logs; 1. Navigational tree;


2. Traceability for each command; 2. Additional details for individual FFUs;
3. Summary of all FFUs for user evaluation and performance analysis; 3. Timer functionality.
4. One-click to export into an Excel file.

HANDHELD CONTROLLER
A handheld controller is made available for ease of control of an individual FFU for
isolated control or during maintenance. The handheld controller is capable of control
and monitoring individual and/ or a group of FFU, making it an extremely useful tool
especially during FFU commissioning work.

11
FFU SPECIFICATIONS
(AC MOTOR) TECHNICAL DATA

TOTAL STATIC POWER NOISE VIBRATION


MODEL WxLxH AIR VELOCITY
PRESSURE CONSUMPTION LEVEL LEVEL

mm ft Pa Inch w.g. W m/s fpm db(A) mm/s inch/s

600 x 600 x 250


F-22AL 2' x 2' 250 1.0 80 0.45 88.5 50 0.7 0.0276
575 x 575 x 250

600 x 900 x 250


F-23AL 2' x 3' 220 0.8 110 0.45 88.5 51 0.8 0.0314
575 x 875 x 250

600 x 1200 x 250


F-24AL 2' x 4' 210 0.8 120 0.45 88.5 52 1.0 0.0394
575 x 1175 x 250

600 x 1200 x 275


F-24AM 2' x 4' 310 1.2 155 0.45 88.5 53 1.0 0.0394
575 x 1175 x 250

900 x 1200 x 275


F-34AM 3' x 4' 250 1.0 175 0.45 88.5 53.5 1.2 0.0472
875 x 1175 x 275

900 x 1200 x 275


F-34AM1 3' x 4' 275 1.1 225 0.45 88.5 53 1.2 0.0472
875 x 1175 x 275

1200 x 1200 x 275


F-44AM1 4' x 4' 205 0.8 245 0.45 88.5 55 1.2 0.0472
1175 x 1175 x 275

1200 x 1200 x 275


F-44AH 4' x 4' 285 1.1 305 0.45 88.5 53.5 1.2 0.0472
1175 x 1175 x 275

Remark:
1. Test point of noise level is located at 1.5 m (equivalent to 4.9 ft) below the filter downstream.
2. Test point of air velocity is located at 0.15 m (equivalent to 0.49 ft) below the filter.
3. FFU sizes can be customized upon request.
4. FFU power consumption listed are calculated based on FFU intial performance.

(EC MOTOR) TECHNICAL DATA

TOTAL STATIC POWER NOISE VIBRATION


MODEL WxLxH AIR VELOCITY
PRESSURE CONSUMPTION LEVEL LEVEL

mm ft Pa Inch w.g. W m/s fpm db(A) mm/s inch/s

600 x 600 x 250


F-22EL 2' x 2' 270 1.1 55 0.45 88.5 49 0.6 0.0236
575 x 575 x 250

600 x 900 x 250


F-23EL 2' x 3' 250 1.0 70 0.45 88.5 50.5 0.6 0.0236
575 x 875 x 250

600 x 1200 x 250


F-24EL 2' x 4' 240 0.8 85 0.45 88.5 51.5 0.8 0.0314
575 x 1175 x 250

600 x 1200 x 275


F-24EH 2' x 4' 370 1.5 90 0.45 88.5 51 0.8 0.0314
575 x 1175 x 250

900 x 1200 x 275


F-34EH 3' x 4' 360 1.4 125 0.45 88.5 52.5 0.8 0.0314
875 x 1175 x 275

1200 x 1200 x 275


F-44EH 3' x 4' 360 1.4 180 0.45 88.5 53.5 0.8 0.0314
1175 x 1175 x 275

Remark:
1. Test point of noise level is located at 1.5 m (equivalent to 4.9 ft) below the filter downstream.
2. Test point of air velocity is located at 0.15 m (equivalent to 0.49 ft) below the filter.
3. FFU sizes can be customized upon request.
4. FFU power consumption listed are calculated based on FFU intial performance.

12
FFU PERFORMANCE CURVES

13
FFU PERFORMANCE CURVES

14
GLOBAL CLEANTECH SOLUTIONS PROVIDER

www.mayairgroup.com l www.mayair.com.my

Corporate Headquarters (HQ)


MayAir Manufacturing (M) Sdn. Bhd. Authorized Representative:
No.35, Jalan P4/6, Seksyen 4, Bandar Teknologi Kajang,
43500 Semenyih, Selangor, Malaysia.
Tel : +603-8210 7373
Fax : +603-8210 7337
Email : info@mayair.com.my

MayAir (Thailand) Co. Ltd.


No.368/9, Patio Ramintra, Watcharapon Road Scan here for digital copy:
Tha-raeng, Bangkhen, Bangkok 10220, Thailand
Tel : +66-02 0131 448
Fax : +66-02 0131 449
Email : info@mayair.com.my MayAir reserves the right to make changes in the product
specifications, designs and technical information or
MayAir Singapore Pte. Ltd. discontinue any of the products at any time without prior
No.63, Jalan Pemimpin, notice. Please contact our sales representatives for the latest
product information at your convenience.
#03-02, Singapore 577219, Singapore.
Tel : +65-6275 7068/ +65-8350 1969
Email : info@mayair.com.my 2024 MayAir INTLM-B-FFU-U-E-V1-R1-2403