Professional Documents
Culture Documents
TDS Cams 007
TDS Cams 007
APPLICATION NOTES
CAMS 007 is applied at concentrations between 5 and 20 mg/L into the recirculating electrolyte as a function of the
total electrolyte volume in the system. Actual dosage is dependent on the surface tension, the plating rate, temperature,
losses through bleeding and spillage, and losses in other in-line processes. It is best optimized by on-site monitoring of
actual acid-mist levels over time (direct determination using OSHA 113 or NIOSH 7908 methods) or by indirect
methods such as monitoring surface tension or air particulates.
It is integral to the supply and service of this product by ChemQuest Africa to provide a qualified engineer and
appropriate equipment during the initial use to optimize the dosage and correct application.
TYPICAL PROPERTIES
Appearance: Clear, odourless liquid
Density at 20°C: Approx. 1.01 g/cm³
Kinematic Viscosity at 20°C: 1.35 x 10-6 m2/sec
Water solubility at 20 °C: Fully miscible / soluble
Organic solubility at 20 °C: Less than 0.1 ppm by volume