Maa Santoshi NDT Services: Magnetic Particle Test Report

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

MAA SANTOSHI NDT SERVICES

Deals in : UT, MPT, PT, SR


OFFICE- IDC, KALUNGA. P.O. JHARTARANG. Dist- Sundargarh, OdishaMob : 9776071075, 7978489251. Email : nagsk.2011@gmail.com

MAGNETIC PARTICLE TEST REPORT


CLIENT : M/S. M.R. ENGINEERS PVT. LTD LOCATION : RAJGANGPUR

DATE OF TESTING: 20.10.2023 REPORT DATE : 21.10.2023

STAGE : AFTER FINAL MACHINING REPORT NO : RKL-MPT/MREPL/010/2023

JOB DESCRIPTION : 52" TO 56" BEARING OUTER END PLATE DRG NO : 4.596904.K

SURFACE PREPARATION : MACHINED & AS CAST SURFACE TEMP. : AMBIENT TEM.

ACCEPTION CRITERIA : DAN. STD. 2.8.121 CLASS C PROCEDURE: DAN. STD. 2.8.121

TECHNIQUE USSED : NONFLUORESCENT WET METHOD MACHINE MAKE & NDTE YOKE CT-30K2. (SL. NO- 16510)
WITH YOKE MACHINE MODEL :

PARTICLE MANUFACTURE : PMC FLAW CHECK MATERIAL GRADE : GE 300

WHITE CONTRAST : SNOW ITE CONTRAST COAT - MSL-61B LIGHTING : VISUAL-SUN LIGHT.

MAGNETIC INK : MAGNETIC INK- ML-72 B P.O.NO 24944034 OA

CURRENT : AC YOKE HEAD DISTANCE : 4" TO 6" DIRECTION OF MAGNETISM : LONGITUDINAL

JOB DETAILS DRG NO SIZE QTY OBSERVATION REMARKS

WC1C6403001 No Unacceptable Indication


P.O. Line No - 1 4.596904.K 935X285X285 4 According To Acceptable
Sl No - 1 to 4 Specification Detected

WC1C6403002 No Unacceptable Indication


P.O. Line No - 2 4.596904.K 935X285X285 4 According To Acceptable
Sl No - 5 to 8 Specification Detected

WC1C6403003 No Unacceptable Indication


P.O. Line No - 3 4.596904.K 935X285X285 4 According To Acceptable
Sl No - 9 to 12 Specification Detected

TOTAL TESTED QTY- : 12Nos

SIGN. OF TECHNICIAN SIGN. OF MREPL SIGN. OF INSPECTOR

You might also like