Punching Shear Checking

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Punching Shear Checking

Design Conc Strength = 45 N/mm2


Effective Loading Area = 800 mm x 800 mm in plan view
Slab Thcinkess = 165 mm
Effective Depth = 165 - 25 - 12 - 16/2
= 120 mm
Perimeter = 3200 mm
Effective Shear Area = 3200 mm x 120 mm
2
= 384000 mm
1.5d Effective Shear Area = 4520 mm x 120 mm
2
= 542400 mm

Design Gravity Load = 170 kN (Unfactored) = 238 kN (x1.4 Factored)

Checking at Loading Face


Shear Stress = 238 kN
2
384000 mm = 0.62 N/mm2
< 5.37 N/mm2 OK

0.5 2
Allowable Shear Stress = 0.8 fcu or 7.0 N/mm whichever is the lesser
2
= 5.37 N/mm

Checking at 1.5d offset from the Loading Face


Shear Stress = 238 kN
2
= 542400 mm = 0.44 N/mm2
< 0.79 N/mm2 OK

(1/3) (1/4)
Allowable Shear Stress = 0.75 (100As/bd) (400/d) / 1.25
2
= 0.79 N/mm

Provide As = T12 - 100mm c/c (100As/bd)(1/3) = 0.980


2
= 1130.97 mm /1m (400/d)(1/4) = 1.351