Function code Name Current Setting Factory default
P0.03 Maximum frequency 50 50. Hz P0.04 Upper frequency limit 50 50. Hz P0.05 Lower frequency limit 0 0 P0.07 Frequency A command source 1 0 P0.08 Frequency B command source 0 0 P0.10 Frequency command selection 0 0 P0.11 Acceleration time 10 sec 5 sec P0.12 Decceleration time 10 sec 5 sec P2.01 Motor rated power 5.5 depend on model P2.02 Motor rated frequency 50 depend on model P2.03 Motor rated speed 1440 depend on model P5.13 Ai1 lower limit corresponding setting 0 0 P5.14 Ai1 upper limit 10 10v P5.15 Ai1 lower limit corresponding setting 100 100 P5.16 Ai1 filter time constant oo.10 S oo.10 S P6.04 A01 function selection 0 0(P0.03) (running frequency)
P5.01 S1 terminal function 1 1 (forward)
MDO 01 & MDO 2
Function code Name MDO 01 MDO 02 P0.03 Maximum frequency 54 62.oo P0.04 Upper frequency limit 54 62.oo P0.05 Lower frequency limit 0 0 P0.07 Frequency A command source 1 1 P0.08 Frequency B command source 0 0 P0.10 Frequency command selection 0 0 P0.11 Acceleration time 5.o 3.o P0.12 Decceleration time 5.o 3.o P2.01 Motor rated power 15.o 22.o P2.02 Motor rated frequency 50.o 50.o P2.03 Motor rated speed 1460 1470 P5.01 S1 terminal function 1 1 P5.13 Ai1 lower limit corresponding setting o.o 0 P5.14 Ai1 upper limit 10.o 10 P5.15 Ai1 lower limit corresponding setting 100.o 100 P5.16 Ai1 filter time constant oo.10 o.10 P6.04 A01 function selection 0 0
TDO & CARRIAGE
Function code Name TDO CARRIAGE P0.03 Maximum frequency 47.5o 54.o P0.04 Upper frequency limit 47.5o 54.o P0.05 Lower frequency limit oo.oo 0 P0.07 Frequency A command source 1 1 P0.08 Frequency B command source 0 0 P0.10 Frequency command selection 0 0 P0.11 Acceleration time 3.o 3.o P0.12 Decceleration time 3.o 3.o P2.01 Motor rated power 45.o 2.2 P2.02 Motor rated frequency 50.o 50.oo P2.03 Motor rated speed 1450 1400 P5.01 S1 terminal function 1 1 P5.13 Ai1 lower limit corresponding setting 0 0 P5.14 Ai1 upper limit 10 10 P5.15 Ai1 lower limit corresponding setting 100 100 P5.16 Ai1 filter time constant o.10 o.10 P6.04 A01 function selection 0 0
TRIM SUCTION BLOWER
Function code Name Current Setting Factory default P0.03 Maximum frequency 50.oo 50.ooHz P0.04 Upper frequency limit 50.oo 50.ooHz P0.05 Lower frequency limit oo.oo oo.oo P0.07 Frequency A command source 1 0 P0.08 Frequency B command source 0 0 P0.10 Frequency command selection 0 0 P0.11 Acceleration time 30.oo depend on model P0.12 Decceleration time 30.oo depend on model P2.01 Motor rated power 30 depend on model P2.02 Motor rated frequency 50 50.ooHz P2.03 Motor rated speed 1470 depend on model P5.01 S1 terminal function 1 1 P5.13 Ai1 lower limit corresponding setting 0 o.o% P5.14 Ai1 upper limit 10 10 P5.15 Ai1 lower limit corresponding setting 100 100 P5.16 Ai1 filter time constant 0.1O o.10 P6.04 A01 function selection 0 0