2024+Blazemaster+Brochure Compressed

You might also like

Download as pdf
Download as pdf
You are on page 1of 12
ATLANTA INDUSTRIES <@ BlazeMaster ~w FIRE PROTECTION SYSTEMS PRE PROTECTION SYSTEMS 1984-2014 THE SCIENCE OF SAFETY Blazemaster® is the registered trademark of The Lubrizol Corp. The Lubrizol Corporation is a Berkshire Hathaway Company. ‘Atianta Industries, Inc. is a Exclusive Distributor of Blazemaster® — ,@ BlazeMaster FIRE PROTECTION SYSTEMS Blazemaster’ pipes and fittings are designed specifically for fire sprinkler systems. They are made from a specialty thermoplastic known as chlorinated polyvinyl chloride (CPVC). Blazemaster' pipe and fittings provide unique advantages in sprinkler installations including superior hydraulics in comparison to traditional metal systems, ease of joining, increased hanger spacing and ease of assembly. Additionally itis base on a technology with a continuous and proven service history of more than 30 years. Ws el alae eee ello le) Pipe Blazemaster’ CPVC Sprinkler pipe in SDR 135 conforms to the requirements of ASTM F442. Fittings Blazemaster’ CPVC Sprinkler fittings conform to the requirement of ASTM F438 (Schedule 40) & ASTM F439 (Schedule 80). Female threaded adapters for sprinkler head connections with brass inserts. Solvent Cement Blazemaster’ CPVC socket connections should be joined with Weld-On’ Blazemaster’ Cement which meets ASTM F493, No other cements are recommended for use with Blazemaster’ products and use of such non-proved welding agents will invalidate the manufacturers warranty. Wilt eh a evs Sea oR a cee Applications ‘+ NFPA 13 -Light Hazard occupanies as defined in the Standard for Installation of Sprinkler Systems, such as Churches, Schools, Hotels, Condominiums, Hospital, Offices & High Rises. + NFPA 13D - Residential occupancies as defined in the Standard for Sprinker Systems in One and Two Family Dwellings and Manufactured Homes. + NFPA 13R- Residential and Multi-family + NFPA 90- Air plenums, as defined by the Installation of Air Conditioning and Ventilating Systems |“ NFPA 24- Underground water pressure service, ADVANTAGES + PROVEN PERFORMANCE Resistant to corrosion and sealing and-—_—foreign contaminant build even in salt air environments Reduced installation time Eliminates need for torches or complicated —_heat-fusion techniques. ‘Simple joining method. Ensure optimal flow rate and excellent hydraulic capabilites (GFactor of 150) that will not diminish overtime. Allows for pipe downsizing & Pump rate reduction eA NEC Flammability Blazemaster is suitable for wet, automatic fire sprinkler systems because of I excellent corrosion resistance, low friction loss, and easy installation. Itis uniqui smoke generation. Burning Resistance ceve BlazeMaster — FIRE PROTECTION SYSTEMS Greater resistance to seismic activity than copper or steel systems Easily repaired or modified on site Designed to 50 year expectancy Lightweight. Allows greater ease of installation Little to mo maintenance required excellent balance of properties such as lightweight, that it offers outstanding resistance to fire and low ill not sustain burning, It must be forced to burn due to I's very high Limiting Oxygen Index (LOI) of 60. LOI is the percentage of oxygen needed in an atmosphere to support combustion, Since earth’s atmpasphere is only 21% oxygen, CPVC will not burn unless a flame is constantly applied and stops burning when the ignition source is removed. ‘Smoke Generation ‘The smoke toxicity of CPVC pipe is low compared with the common building and finish materials present in homes. a reallo Po ala A great advantage that Blazemaster’ pipe enjoys over its metallic competitors is a smooth inner surface which is resistant to scaling and fouling. This means that friction pressure losses the beginning and do not significantly increase as the systems ages, as can be the case with metal pipes. The values in the following fluid flow tables are based on the Hazen Williams formula and a surface roughness constant of C=150 for Blazemaster’ Pipe, providing a maximum water flow coverage. BlazeMaster FIRE PROTECTION SYSTEMS Surface roughness constant for other piping material are given below: _ 100 8° _g 1.852_ #0.2083 (—E d 4.8655 Where f= friction head in feet of water per 100 feet of pipe diameter of pipe in inches iow rate in gallons per minute pipe surface roughness constant ‘Constant (C) Type of Pipe 150 CPVC Pipe, new-40 Years: 130-140 Steel/Cast Iron Pipe, New 125. Steel Pipe, old 120. Cast ron, 4-12 years old 110 Galvanized Steel/Cast Iron 13-20 Years 60-80 Cast Iron, Worn/Pitted Blazemaster’ Pipe Dimensions (SDR 13.5) - Inches (Millimeters) Wall Thickness (7) Nominal Si ‘Outside Diameter (OD) ‘Alowable Water Won-UL UL Average Tolerance | Minimum [Tolerance —_| Pressure Rating = [em > m= pam) om [om | om | mm pom [mm | om | mm | atraerszazc wz | 1s oso | 213 | 20008 | oxo | 0062 | 157 | +002 | 051 sa | 20 | 34 | 20 | 1.050] 267 | 20008 | o10 | 0078 | 198 | +002 | o51 wv | as |v | 25 | ais] aa | 20005 | 013 | 0097 | 246 | +002 | ost rie | 32 | vue | 32 | 1660 | 422 | +0005 | 013 | ors} 312 | +002 | osr | 315 Ps! (2222 kg/cm’) aaa | ao | vv | ao | 1900] 42 | so00s | 015 | ora | 358 | 002 | ost x | 50 | 2 | so | 2375] 603 | 20006 | ors | 0176 | 447 | +0021 | oss aux | os | ave | 6s | 2075] 730 | sa007 | 018 | 0213] 541 | +0025 | 086 x | a | x | a | 3500] eas | 0008 | 020 | 0259 | 658 | +0031 | 079 « | 10 4500 | 1143 | so009 | 023 } 0333 | 846 | +004 | 102 Note: SDR 1315 (Standard Dimensional Ratio 13.5) means the rato of ouside Gameter to wal ticknass (ASTM F#A2) Etre a Etre —— =| 12 15 1. 15 34 | 20 34 | 20 L_| 1 25 1 25 L viva | 32 via | 32 - wa | 2 ua | 4 via | 4 LI wa | 4 2 50 2 50 2 50 ain | 65 an | 65 ne | 65 3 80 3 80 4 100 4 100 ea oR ale ro 12 15 7 12 15 sa | 0 3a | 0 1 5 1 25 wa | 32 4a | 32 1a | 32 ve | 4 vin | 4 - 112 | 4 2 50 2 50 2 50 ain | 65 ain | 65 an | 65 3 8 3 20 3 80 4 100 4 100 4 100 <@ BlazeMaster — FIRE PROTECTION SYSTEMS PIN prerens) wee} a aaa | 6s [| ee | waa | 40 tan | 40 2 | © 2 | 30 2 | 2 212 | 65 aia | 6 3 | % 2 | » 4 | 100 4 | 1 REDUCING COUPLING REDUCING BUSHING BARU | 20x15 |12x1-14) 40x32 tia | 25x15 | 2x12 | soxis 1x3 | 25x20 | 2x3/4 | 50x20 34x12 | 20x15) 2x34 | 50x20 axa |25x15) 2x1 | 50x25 1x34 | 25x20) 2x1-v4| 50x32 teva} szx1s | 2x1 | 50x25 tvax ie [32x15 | 2x1-12| 50x40 V-v/4 3/4) 32x20 | 2x 1-1/4 | 50x32 tevaxaya | 32x20 | 21/2x2| 65x50 tv4xt | 32x25 | 2x1-172 | 50x40 traxr [32x25 | 3x2 | a0x50 vv2xv2| 4x15 | 2-1/2x2 | 65x50 vvaxve [40x15 | 3x2-12| 80x65 1-123/4 40x20 | 3x2 | 80x50 tevax3i4 | 40x20) 4x2 | 100x50 rvaxt | 4oxas | 3x2-v2_| 90x65 varaxr [40x25 | 4x2-V2) 10x65 Text) 40x32 | 4x3 | 100%80 2x1a_| 50x15 yaxsianiia | 20%20%15 | 22x34 | SdxS0x20 | 4xaxr | t00x100x32 | taixva | 2sxaseis|—axax1 | soxsoxas | 4x4xt2 | 100x 00x40 L] 1x 1K 3/4 (25x25x20 2x2x 1-14 50x 50x32 4Ax4x2 100 x 100 50 [— vaaxtvaxin [3203215 | 2xaxta2 | soxsoxao | 4x4x242 | 100x100%65 | fitters |s2es2020 | avaxzime | ebnesxas | axe | toxi0nc80 devia tetrad | 32x32x25 | 24/2x21/2«1-172 | 656540 Tvaxiaxi2 | 40x40x15 | 21/2x2-1/2%2 | 65%65%50 taex1ax34 | 40x40x20 3x3x1 80x 80x25 waxiax1 | 40x40x25 3x3x142 | Boxe0x40 Tevaxte12x 1-1/4 | 40% 40%32 3x3x2 80x80%50 2x2xU2 | Soxsox1s | 3x3x212 | 80x80x65 aera Parse SI Peers Heo) ADAPTER (SOCKET) De aucerecaa) i Wax12 | 15x15 1 25 1 7 ai4xv2 | 20x15 BAX 12 | 20x18 rua | 32 rxw2 | 25x15 1x2 | 25x15 win | 40 1x4 | 25x20 yi raya | 25x20 2 50 * avaiable in B5PT or NPT “avaiable in SPT or NPT. * avalablen BSPTor NET Ears Pray ADAPTER TEE (BRAS: CS) 314x172 | 20x15 I 1 cd txwa | 25x15 — MWe] @ Vax 2 | 32x15 tam || 25 12x12 | 40x15 2 50 2x2 | sox15 pail in BSPT orNPT pale B5PTorNPT TW v4s UT UL FITTING = rll «| » uw] » |} 28 fil) * 3 ‘|e |} EL 1] _\ vva | 32 wa | 2 =H uw | 2» —— a 40. IL. wan a LJ 1 25 “|S | -® aw} a sa] = nan | “| aes ica Size cre 6 = = Size — az | u |» "| 3 14 32 a 2 ve | me 2 = 2A 6 : | ie fostenerentatd fates txaa | 25x20| 202x2 | 65x50 vvaxt [32x25] 3x2 | 80x50 svat varnxt [40x25 | 3x2-12 | 80x65 jax 14ax 1-1/4 | 40x32 2x1 | 50x25 2x1 axtw | S0x32 ae 2xtaa | soxa0 3a BlazeMaster — FIRE PROTECTION SYSTEMS Many epttal eS Cease eC GCoy reread | 25x25x20) 2xax1 | Soxs0x25 | wvaxrvaxaia | 32x32420 | 2x2<1-14 | 50x50"32 tT vaax and | 32x32K25 | 2x2K1-41/2 50x50x40 sia eineser|z0Ns| I 14x Td 32x25K25 | 21/2x21/2«1 65x65x25 1X 1/2BSPT | 20x15 ! waa rvenr | 40032025 |21ax212x1-14 | 65x65x32 sian [asx V-U2K1-1/23/4 | 40X40K20 2-1/2K2-1/2KI-1/2 | 65x65x40 TX V2NPT | 25x15, raaxtvaxr | 4ox40xas | 242xzaax2 | 65x65%50 rare rvae vila | 40x4ox32 | 3x3x2—_ | 808050 2xtiiext | 50x40x25 | 3x3x2472 | 8OxBDKES 2xax34 | Soxs0x20 "lB WOT SFR PEST Er Poruintcecan in i oi ie txt | asxas aaxve | 20x15 : waar | 32x32 rea | 25x15 "sain in BST or NPT * alain BST orn PST 3 PES ADAPTER SOCKET) in i a Ea fe rx1 | 25x25 4 a rant | 30x32 * aalable in PT or NPT ACCESSORIES oes ware Ens *avalalein BSPT or NPT Poe 1 Pint (16.02) «e@ BlazeMaster FIRE PROTECTION SYSTEMS 1.) Cutting 2.) Deburring 3,)Jointing Preparation Cut pipe squarely using a ratchet Use a chamfering tool or other tool to. Using a clean, dry rag, wipe loose dirt cutter, a wheeltype plastic tubing remove burrs and fittings from the and moisture from the fitting socket cutter, a power saw, or afine toothed _inside and outside ofthe pipe. and pipe end. saw. 4.) Application of Cement ‘Apply solvent cement inside the fitting _§,) Assembling Apply solvent cement outside the socket. Do not puddle the cement in Immediately insert the pipe into the Spigot of pipe using a brush ordauber. fitting, fitting socket while rotating the pipe 1/Atum and hold for 30 seconds. 6.) Completed Assembly A bead of solvent cement should be evident around the pipe and fitting juncture <@ BlazeMaster — ~ FIRE PROTECTION SYSTEMS PROJECT: [Residential ‘Oceanaire Century Commonwealth The Royalton Viridian Pasay iy 17 Ses ‘enon chy 22 Soy Paugcty-o¢ Storey Sniuan Cy S35t0—36 D University Place iPacfc Residences The Imperium Solano Hills Manis hy 33 Storey Manila cy 28 Srey ai Cy “62 on Paranaque Cy 5 Sorys ik Tower escent Park Blue Sapphire Residence The Grand Hamptonsi ‘ueron UI. Commercial & Hospital Bohol Hennan Resort Tambuli Beach Cub anal Boho Mactan isn eb Mandarin Plaza Hotel Manila Doctor's Hospital UST General Hospital, bu ani lnicy Waterfront Marriott, |. Office and School Marina Bay Club Shangri-La Hotel, Vancouver Renaissance Hotel IV. Hospital Santa FeHosptal Baptist Memorial " spn «@ BlazeMaster — FIRE PROTECTION SYSTEMS OUR LATEST BUREAU OF FIRE PROTECTION MEMORANDUM fm Fpubic ott Prigeines Department ofthe interior and Local Government Bureau of Fire Protection NATIONAL HEADQUARTERS. ‘nan Reed. ra Baperg Pap ae, QuEzon Cty MEMORANDUM 10 Regional Drectors, BFP Regions 112, ARMM, CAR CARAGA and NCR: Director, FNT: and Heads of Occ, BEP National Headauartere ‘sueect Use of Chornaned Potyiny Chere (CPUC) Pipes and Fittings for Fire Sprimier Systems ote 21 March 2082 ‘A amber of quaes have reached ti Ofice cegerng the applesblly of Chonates Petnny Choe (CPC) Per ara Pings. and ke Sein! or eerie syterts, “he BFP acinowledpes at new ipa mats ad te development of new mao fo Ineaing and jneng pve forte spies sytem hove reine Coun. ‘Crtfonton Goard CPOE), and oer Rleratonoy-ecxeyled slated, 88 wel #8 suppomentat rar carpleerty sarc ated eran For CPvC Ppos and Fins, and ts Selon. NFPA 13 saree pers se. proved et ‘hoy ae ined in secoréuncn win thd sig umtatons, cate tation icons On he taker hand. the GFP may eles 1o NFPA 20-on tne CFVC Watecbaced Pie Sprites Syaer ‘rapecton. esa and attnance. |S per NEPA 13 (Stancors or te latalon ot Spier Sys) Nght hazard cxaipances case oecopances havng vies and condone sb to rel sheer. ches ibs ecicabonal hosplas (reucing ateralMoapals and vary fees). neon emt Eevats (nce lage stack roms), museums swing s conabteen home. ts Uncaing ela processing estonia, vetawartSeaung stews, theatre 240, aura lewcacing staged an proseenms) and used alse Al Nohtae baglervcure appears {1athwabie sj iaNFPA TS bai hand Secupancy imntons ‘As per NFPA 4 (Fi Prmvanion Cod), Kght hazard occupancies may ince sore bulenge o rooms acanod ee ofos, assur, crurches sembly hal, cust" aeae of etsamelels, te Ths Casareaton antopae Matte many ef const ems ae ore orcorsbuse 30 aanged thal a fr a helo sea apy. nti regard and eonsgoing he above, advise your Otters and Parserne mat basta Utne Chose Pel Chlonde(CPVC) Ppt ana Fangs ards Sealant fr Fe Spore ‘hata ore ppzale oc hgh hazaré occupancies ae deindin NFPA 12 Actors appcaoes, ug, bu et rede a ponum. Systm srs, underground, auc and garage ies isvone. sale refered ne GPUE mardacure’ ano denn sete 8 Pestmeatowed by NEPA or oer mernatonay-acepld Standards endo” Isengs, peer Soe \ = Forges serinaon and coniance jesuer Offoern- charge Depuy Sel or Acris 0p ee + Sector, O86 — <@ BlazeMaster FIRE PROTECTION SYSTEMS OUR LATEST BUREAU OF FIRE PROTECTION MEMORANDUM sumsect) Linn nt Anaya Pts Cie (CPR ge Sir ATLANTA INDUSTRIES Unit 35th Atlanta Centre, #31 Annapolis St,, Greenhills, San Juan City Tel. nos.: 8723.0781 to 88 | 874.4700 Fax no. 8722.8705 | 8723.9576 Website: http//wwwatlanta.ph Email: marketing@atlanta.ph Subscribe to our Youtube Channel Atlanta Industries Official Like us on Facebook atlantaindustriesine

You might also like