Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

9RA type

DC Fan

■ Features
Low Noise and Energy Saving
Compared to our current model,(1) noise level has been more than halved(2) and
power consumption has been reduced by 39%.(3)

Moreover, the models with PWM control, which enables the control of fan speed,
provide further optimized noise level and efficiency.

Long Life
This fan lasts 1.5 times longer than the current model,(1) and is capable of continuous
operation for 60,000 hours (approximately 7 years), improving the maintainability.

Rich Lineup
The product lineup is available in a wide variety in 12/24/48 voltage, cooling
performance, noise level, and PWM control. This allows users to choose the most
suitable one for their applications.

(1) Current model: 120 × 120 × 25 mm San Ace 120 9G type DC Fan (model: 9G1212G401).
(2) A 4 dB(A) decrease in noise level.
(3) For models 9RA1212P4G001 and 9RA1212G4001

120 × 120 × 25 mm
■ Specifications
The models listed below have ribs and pulse sensors with PWM control function. For models without ribs, append "1" to the end of model numbers.
Rated Operating PWM Rated Rated Max. static Operating Expected
voltage Rated speed Max. airflow Noise level
Model no. voltage duty cycle* current input pressure temperature life
range [min-1] [m3/min] [CFM] [dB(A)]
[V] [V] [%] [A] [W] [Pa] [inchH2O] [°C] [h]
100 0.55 6.6 4500 3.68 130 120 0.48 47
9RA1212P4G001 12 10.8 to 13.2
20 0.06 0.72 1250 1.02 36 9.2 0.037 15
100 0.28 6.72 4500 3.68 130 120 0.48 47 60000/60°C
9RA1224P4G001 24 21.6 to 26.4 -20 to +70
20 0.05 1.2 1750 1.43 50.5 18.1 0.073 22 (90000/40°C)
100 0.15 7.2 4500 3.68 130 120 0.48 47
9RA1248P4G001 48 43.2 to 52.8
20 0.03 1.44 1650 1.34 47.3 16.1 0.065 21
* PWM input frequency is 25 kHz; models without specifications at 0% PWM duty cycle have zero fan speed at 0%.

The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers.
Operating
Rated Rated Rated Max. static Operating Expected
voltage Rated speed Max. airflow Noise level
Model no. voltage current input pressure temperature life
range [min-1] [m3/min] [CFM] [dB(A)]
[V] [V] [A] [W] [Pa] [inchH2O] [°C] [h]
9RA1212G4001 0.55 6.6 4500 3.68 130 120 0.48 47
9RA1212E4001 0.41 4.92 4000 3.3 116.5 96 0.386 45
9RA1212A4001 12 7 to 13.8 0.3 3.6 3500 2.86 101.1 73 0.293 42
9RA1212H4001 0.26 3.12 3200 2.62 92.4 61 0.245 39
9RA1212M4001 0.12 1.44 2200 1.8 63.5 29 0.116 28
9RA1224G4001 0.28 6.72 4500 3.68 130 120 0.48 47
60000/60°C
9RA1224E4001 0.22 5.28 4000 3.3 116.5 96 0.386 45 -20 to +70
(90000/40°C)
9RA1224A4001 24 14 to 27.6 0.16 3.84 3500 2.86 101.1 73 0.293 42
9RA1224H4001 0.13 3.12 3200 2.62 92.4 61 0.245 39
9RA1224M4001 0.07 1.68 2200 1.8 63.5 29 0.116 28
9RA1248G4001 0.15 7.2 4500 3.68 130 120 0.48 47
9RA1248E4001 48 36 to 55.2 0.11 5.28 4000 3.3 116.5 96 0.386 45
9RA1248A4001 0.09 4.32 3500 2.86 101.1 73 0.293 42

Models with the following sensor specifications are also available as options:

■ Common Specifications
□ Material Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1)
□ Expected life Refer to specifications
(L10 life: 90% survival rate for continuous operation in free air at 60°C, rated voltage)
Expected life at 40°C is for reference only.
□ Motor protection function Locked rotor burnout protection, Reverse polarity protection
□ Dielectric strength 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
□ Insulation resistance 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
□ Noise level At 1 m away from the air inlet
□ Operating temperature Refer to specifications (Non-condensing)
□ Storage temperature -30 to +70°C (Non-condensing)
□ Lead wire + Red − Black Sensor Yellow Control Brown
□ Mass 210 g
■ Airflow - Static Pressure Characteristics
PWM duty cycle Operating voltage range PWM duty cycle Operating voltage range
(inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa)
12 VDC PWM duty cycle 100% 24 VDC PWM duty cycle 100%
160 160 160 160
0.6 0.6 13.2 V 0.6 0.6 26.4 V
140 PWM duty cycle 140 140 PWM duty cycle 140
100% 100%
0.5 0.5 0.5 0.5
120 120 12 V 120 120 24 V
Static pressure

Static pressure

Static pressure

Static pressure
0.4 100 0.4 100 0.4 100 0.4 100 21.6 V
50% 10.8 V 50%
80 80 80 80
0.3 0.3 0.3 0.3
60 60 60 20% 60
0.2 0.2 0.2 0.2
40 20% 40 40 40
0.1 0.1 0.1 0.1
20 20 20 20

0 0 0 0
0 1 2 3 4 5 (m3/min) 0 1 2 3 4 5 (m3/min) 0 1 2 3 4 5 (m3/min) 0 1 2 3 4 5 (m3/min)
0 20 40 60 80 100 120 140 160 (CFM) 0 20 40 60 80 100 120 140 160 (CFM) 0 20 40 60 80 100 120 140 160 (CFM) 0 20 40 60 80 100 120 140 160 (CFM)
Airflow Airflow Airflow Airflow
9RA1212P4G001 9RA1212P4G001 9RA1224P4G001 9RA1224P4G001

PWM duty cycle Operating voltage range


(inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa)
48 VDC PWM duty cycle 100%
160 160 160 120
0.6 0.6 52.8 V 0.6
13.8 V 13.8 V
140 PWM duty cycle 140 140
100% 0.4 100
0.5 0.5 48 V 0.5
120 120 120
12 V 12 V
80
Static pressure

Static pressure

Static pressure

Static pressure
0.4 100 50% 0.4 100 43.2 V 0.4 100 0.3
7V 7V
80 80 80 60
0.3 0.3 0.3
20% 0.2
60 60 60
0.2 0.2 0.2 40
40 40 40
0.1
0.1 0.1 0.1 20
20 20 20

0 0 0 0
0 1 2 3 4 5 (m3/min) 0 1 2 3 4 5 (m3/min) 0 1 2 3 4 5 (m3/min) 0 1 2 3 4 (m3/min)
0 20 40 60 80 100 120 140 160 (CFM) 0 20 40 60 80 100 120 140 160 (CFM) 0 20 40 60 80 100 120 140 160 (CFM) 0 20 40 60 80 100 120 140 (CFM)
Airflow Airflow Airflow Airflow
9RA1248P4G001 9RA1248P4G001 9RA1212G4001 9RA1212E4001

Operating voltage range


(inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa)
0.4 100 80 40 160
13.8 V 0.30 13.8 V 0.30 13.8 V 0.6 27.6 V
70 140
80 0.25 0.25 0.5
0.3 60 12 V 30 12 V 120 24 V
12 V
Static pressure

Static pressure

Static pressure

Static pressure

60 0.20 50 0.20 0.4 100


7V 7V 7V 14 V
0.2 40 20 80
0.15 0.15 0.3
40 30 60
0.10 0.10 0.2
0.1 20 10 40
20
0.05 0.05 0.1
10 20

0 0 0 0
0 1 2 3 4 (m3/min) 0 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) 0 0.5 1.0 1.5 2.0 (m3/min) 0 1 2 3 4 5 (m3/min)
0 20 40 60 80 100 120 140 (CFM) 0 20 40 60 80 100 (CFM) 0 10 20 30 40 50 60 70 (CFM) 0 20 40 60 80 100 120 140 160 (CFM)
Airflow Airflow Airflow Airflow
9RA1212A4001 9RA1212H4001 9RA1212M4001 9RA1224G4001

(inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa)
120 0.4 100 80 40
27.6 V 27.6 V 0.30 27.6 V 0.30 27.6 V
70
0.4 100
80 0.25 0.25
24 V 0.3 24 V 60 24 V 30 24 V
80
Static pressure

Static pressure

Static pressure

Static pressure

0.3 60 0.20 50 0.20


14 V 14 V 14 V 14 V
60 0.2 40 20
0.15 0.15
0.2 40 30
40 0.10 0.10
0.1 20 10
0.1 20
20 0.05 0.05
10

0 0 0 0
0 1 2 3 4 (m3/min) 0 1 2 3 4 (m3/min) 0 0.5 1.0 1.5 2.0 2.5 3.0 (m3/min) 0 0.5 1.0 1.5 2.0 (m3/min)
0 20 40 60 80 100 120 140 (CFM) 0 20 40 60 80 100 120 140 (CFM) 0 20 40 60 80 100 (CFM) 0 10 20 30 40 50 60 70 (CFM)
Airflow Airflow Airflow Airflow
9RA1224E4001 9RA1224A4001 9RA1224H4001 9RA1224M4001
120 × 120 × 25 mm
■ Airflow - Static Pressure Characteristics
Operating voltage range
(inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa)
160 120 0.4 100
0.6 55.2 V 55.2 V 55.2 V
140
0.4 100
0.5 80
120 48 V 48 V 0.3 48 V
Static pressure

Static pressure

Static pressure
80
0.4 100 0.3 36 V 60 36 V
36 V
80 60 0.2
0.3
0.2 40
60
0.2 40
40 0.1
0.1 20
0.1 20
20

0 0 0
0 1 2 3 4 5 (m3/min) 0 1 2 3 4 (m3/min) 0 1 2 3 4 (m3/min)
0 20 40 60 80 100 120 140 160 (CFM) 0 20 40 60 80 100 120 140 (CFM) 0 20 40 60 80 100 120 140 (CFM)
Airflow Airflow Airflow
9RA1248G4001 9RA1248E4001 9RA1248A4001

■ PWM Duty - Speed Characteristics Example


Voltage: 12 VDC Voltage: 24 VDC Voltage: 48 VDC
(min-1) (min-1) (min-1)
5000 PWM frequency: 25 kHz 5000 PWM frequency: 25 kHz 5000 PWM frequency: 25 kHz

4500 min-1 4500 min-1 4500 min-1


4000 4000 4000

3000 3000 3000


Fan speed

Fan speed

Fan speed

2000 2000 2000

1000 1000 1000

0 100 (%) 0 100 (%) 0 100 (%)


PWM duty cycle PWM duty cycle PWM duty cycle
9RA1212P4G001 9RA1224P4G001 9RA1248P4G001

■ PWM Input Signal Example

Input signal waveform


VIH = 4.75 to 5.25 V VIL = 0 to 0.4 V
VIH T1 1
PWM duty cycle (%) = T ×100 PWM frequency 25 (kHz) =
T
Current source (Isource) = 1.0 mA max. (when control voltage is 0 V)
Current sink (Isink) = 1.0 mA max. (when control voltage is 5.25 V)
VIL
When the PWM control terminal is open,
T1 the fan speed is the same as the speed at 100% PWM duty cycle.
Either a TTL input or open collector/drain input can be used for the PWM input signal.
T
■ Example of Connection Schematic
Rated voltage 12/24 V fan Rated voltage 48 V fan

DC fan input voltage DC fan input voltage



○ Inside of DC fan +
○ Inside of DC fan

5V 5V
Isource Isource
Isink 10 kΩ Isink 30 kΩ

PWM input signal PWM input signal


○ -

■ Specifications for Pulse Sensors


Output circuit: Open collector Output waveform (Need pull-up resistor)
In case of steady running
Inside of DC fan

○ (One revolution)
T0
Sensor Pull-up resistor
Pull-up voltage T1 T2 T3 T4 T1 to 4≒ (1/4) T0
Ic
Rated voltage 12/24 V fan
T1 to 4≒ (1/4) T0=60/4N (s)
VOH
Sensor output VCE = +30 V max. N=Fan speed (min-1)
Ic=5 mA max. [VOL=VCE (SAT)=0.4 V max.]

○ (VCE) VOL
Rated voltage 48 V fan
VCE = +60 V max. 0V
Ic=5 mA max. [VOL=VCE (SAT)=0.4 V max.]

■ Dimensions (unit: mm) (With pulse sensor with PWM control function)
4-ø4.5±0.3
Mounting hole 120±0.8 +1
104.8±0.3 25 0
(5) (5)

Lead wire
AWG 24
UL 1007
104.8±0.3
120±0.8

+50
300 0
(10)

Rotating direction Airflow direction

■ Reference Dimensions of Mounting Holes and Vent Opening (unit: mm)


Inlet side Outlet side
104.8±0.3 .5 104.8±0.3 .5
ø4 ø4
4- 4-

18 3
ø1 ø13
104.8±0.3

104.8±0.3
118

118
Notice
●Please read the "Safety Precautions" on our website before using the product.
●The products shown in this catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited.
●For protecting fan bearings against electrolytic corrosion near strong electromagnetic noise sources,
we provide effective countermeasures such as Electrolytic Corrosion Proof Fans and EMC guards. Contact us for details.

3-33-1 Minami-Otsuka, Toshima-ku, Tokyo 170-8451, Japan TEL: +81 3 5927 1020 https://www.sanyodenki.com/

The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies.
“San Ace” is a trademark of SANYO DENKI CO.,LTD.
Specifications are subject to change without notice. CATALOG No. C1123B003 ‘21.10

You might also like