(2) In case a pressure relief valve is used as torque limitor (upon Company written approval), this value may be equal to (11) With atmospheric pressure in the cavity (for suitable design) and Maximum (Differential) Pressure in the valve path.
110% of the relief valve setting.
(3) This is the maximum admissible pressure in the actuator pressure containing parts. (12) This is the ratio of the actuator output torque over the valve required torque at the valve Maximum Differential
Pressure (or with the Maximum Pressure in the valve path).
(4) This is the ratio of the network delivered pressure over the actuator necessary pressure. Safety factor shall be of a minimum of 1.30 unless larger value is specified in the requisition or in the actuated valve
data sheet.
(5) This is the ratio of the actuator acceptable pressure over the network delivered pressure.
(6) All torque / thrust values are subject to test checks at Manufacturer's premises prior to acceptance of the related
equipment. The values reported at FAT are the average of three measurements performed in the same conditions.
(7) This is the ratio of the valve MAST over the considered actuated torque / thrust.
(8) This value must be justified by appropriate calculations and shall be submitted to Company for approval.
(9) This value corresponds to the actuator output torque/thrust at the Network Maximum Supply Pressure.