Technical Specification - Trimoterm PIR

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Technical specification

Trimoterm PIR EN 14509:2013


Trimoterm PIR self-supporting roof, wall and ceiling sandwich panels 1404-CPR-2446

Characteristic Test method Values of individual product thicnesses


Thickness [mm] EN 508-1 50 60 80 100 120 150 200
Weight - wall panels [kg/m2]* EN 14509:2013 10,8 11,4 12,2 13,1 13,9 15,2 17,4
Weight - roof panels [kg/m2]* EN 14509:2013 12,2 12,6 13,5 14,4 15,2 16,5 -
Core density - nominal [kg/m3] EN 1602 43
Use EN 14509:2013 External walls, internal walls, roofs and ceilings
Cover width EN 14509:2013 900-1200 mm (FTPi), 1000 mm (FTPi H, SNPi)
Lenght EN 508-1 Up to 12,3 m
External facing EN 10326 Steel sheet, stainless steel; thicknesses 0.5, 0.55, 0.6, 0.7
Internal facing EN 10326 Steel sheet, stainless steel; thicknesses 0.4, 0.5, 0.55, 0.6, 0.7
Coating EN 10169-1 Standard coating polyester, also PVDF, PUR, FoodSafe available
Thermal transmittance Un,S [W/m2K] - wall FTPi, FTPi H EN 14509:2013 0,45 0,38 0,29 0,23 0,20 0,16 0,12
Thermal transmittance Un,S [W/m2K] - wall SNPi EN 14509:2013 0,44 0,37 0,28 0,23 0,19 0,16 -
Thermal transmittance Un,S [W/m2K] - ceiling FTPi, FTPi H EN 14509:2013 0,46 0,39 0,29 0,23 0,20 0,16 0,12
Thermal transmittance Un,S [W/m2K] - roof, ceiling SNPi EN 14509:2013 0,44 0,38 0,29 0,23 0,19 0,16 -
Thermal influence of the longitudinal joint ΔUj [W/mK] - FTPi EN 14509:2013 0,016 0,010 0,005 0,003 0,002 0,001 0,001
Thermal influence of the longitudinal joint ΔUj [W/mK] - FTPi H EN 14509:2013 0,024 0,015 0,007 0,005 0,003 0,002 0,001
Thermal influence of the longitudinal joint ΔUj [W/mK] - SNPi EN 14509:2013 0,006 0,004 0,003 0,002 0,001 0,001 -
Reaction to fire EN 13501-1 B-s2, d0
Fire resistance FTPi (walls) EN 13501-2 NPD EI60ef EI60ef
Fire resistance FTPi H (walls) EN 13501-2 NPD
Fire resistance (loadbearing roof or ceiling) EN 13501-2 NPD REI30
Fire resistance FTPi (non-loadbearing ceiling) EN 13501-2 NPD
External fire performance SNPi (roof) ENV 1187 BROOF (t1,2,3)
Water permeability EN 12865 NPD
Air permeability (C [m3/Pa*s]; n) - FTPi EN 12114 NPD
Air permeability (C [m3/Pa*s]; n)- FTPi H EN 12114 NPD
Air permeability (C [m3/Pa*s]; n) - SNPi EN 12114 NPD
Water vapour permeability EN 14509:2013 Impermeable
Airborne sound insulation FTPi, FTPi H: Rw (C:Ctr) [dB] EN ISO 10140-3 24 (-2;-4) 26 (-4;-6)
Airborne sound insulation SNPi: Rw (C:Ctr) [dB] EN ISO 10140-3 24 (-1;-3) 25 (-2;-4)
Resistance to point load EN 14509:2013 NPD
Repeated acess load EN 14509:2013 NPD
Durability - all colors EN 14509:2013 Pass
* Panels with standard facings 0,5/0,5 mm
NPD No performance determined May 2015

You might also like