WIND LOADS BASED ON IBC2012(ASCE7-10) (Directional Procedure) [UNIT: kN, m]


__________________________________________________________________________

Design Wind Loads : F = p * Area


Design Wind Pressure : p = qz*G*Cp1 - qh*G*Cp2
Velocity Pressure at Design Height z [psf] : qz = 0.00256*Kz*Kzt*Kd*V^2
Velocity Pressure at Mean Roof Height [psf] : qh = 0.00256*Kh*Kht*Kd*V^2
Calculated Value of qh for X-dir [psf] : qh = 57.92
Calculated Value of qh for Y-dir [psf] : qh = 57.92

Basic Wind Speed [mph] : V = 186.40


Directional Factor for X-dir Wind Loads : Kdx = 0.85
Directional Factor for Y-dir Wind Loads : Kdy = 0.85
Exposure Category : B
Mean Roof Height : H = 41.01
Gradient Height [ft] : Zg = 1200.00
Power Law Exponent : Alpha= 7.00
Kz at Mean Roof Height (Kh) : Kh = 0.77

Structural Rigidity : Rigid Structure

Gust effect Factor for X-dir Wind Loads : Gx = 0.85


Gust effect Factor for Y-dir Wind Loads : Gy = 0.85

Topographic Effects for X-dir Wind Loads : Not Included


Topographic Effects for Y-dir Wind Loads : Not Included
Accidental Eccentricity for X-direction : Wx = None
Accidental Eccentricity for Y-direction : Wy = None
Scale Factor for X-directional Wind Loads : SFx = 1.00
Scale Factor for Y-directional Wind Loads : SFy = 0.00

-----------------------------------------------------------------------------------------------
Wind force of the specific story is calculated as the sum of the forces
of the following two parts.
1. Part I : Lower half part of the specific story
2. Part II : Upper half part of the just below story of the specific story

The reference height for the calculation of the wind pressure related factors are,
therefore, considered separately for the above mentioned two parts as follows.

Reference height for the wind pressure related factors(except topographic related factors)
1. Part I : top level of the specific story
2. Part II : top level of the just below story of the specific story

Reference height for the topographic related factors :


1. Part I : bottom level of the specific story
2. Part II : bottom level of the just below story of the specific story

-----------------------------------------------------------------------------------------------

** External Pressure Coefficients at Windward and Leeward Walls (Cp1, Cp2)

STORY Cp1 Cp2(X-DIR) Cp2(Y-DIR)


NAME (Windward) (Leeward) (Leeward)
---------- ----------- ----------- -----------
Roof 0.800 -0.262 -0.500
4F 0.800 -0.262 -0.500
3F 0.800 -0.262 -0.500
2F 0.800 -0.262 -0.500
1F 0.800 -0.262 -0.500
B1 0.000 0.000 0.000

Modeling, Integrated Design & Analysis Software Print Date/Time : 05/11/2024 23:03
Gen 2021
midas Gen -1/3-
PROJECT TITLE : http://www.MidasUser.com

Company Client
Author File Name final na talaga tangina.wpf

----------------------------------------------

** Velocity Exposure Coefficients at Design Height (Kz)


** Topographic Factors at Windward and Leeward Walls (Kzt)
** Velocity Pressure at Design Height (qz) [Current Unit]
STORY Kz Kzt(X-DIR) Kzt(Y-DIR) Kzt(X-DIR) Kzt(Y-DIR) qz(X-DIR) qz(Y-DIR)
NAME (Windward) (Windward) (Leeward) (Leeward)
---------- ----------- ----------- ----------- ----------- ----------- ----------- -----------
Roof 0.766 1.000 1.000 1.000 1.000 2.773 2.773
4F 0.766 1.000 1.000 1.000 1.000 2.773 2.773
3F 0.708 1.000 1.000 1.000 1.000 2.564 2.564
2F 0.635 1.000 1.000 1.000 1.000 2.300 2.300
1F 0.575 1.000 1.000 1.000 1.000 2.080 2.080
B1 0.000 0.000 0.000 0.000 0.000 0.000 0.000
----------------------------------------------------------------------------------------------

W I N D L O A D G E N E R A T I O N D A T A X - D I R E C T I O N

STORY NAME PRESSURE ELEV.


LOADED LOADED WIND ADDED STORY STORY OVERTURN`G
HEIGHT BREADTH FORCE FORCE FORCE SHEAR MOMENT
---------- -------- ------- ------- ------- ---------- ---------- ---------- ---------- ----------
Roof 2.50286 12.5 1.5 9.05 33.976327 0.0 33.976327 0.0 0.0
4F 2.50286 9.5 3.0 9.05 66.02224 0.0 66.02224 33.976327 101.92898
3F 2.360657 6.5 3.0 9.05 61.659965 0.0 61.659965 99.998568 401.92469
2F 2.181514 3.5 3.25 9.05 61.794366 0.0 61.794366 161.65853 886.90028
G.L. 2.031906 0.0 1.75 9.05 32.180313 0.0 -- 223.4529 1668.9854
--------------------------------------------------------------------------------------------------

W I N D L O A D G E N E R A T I O N D A T A Y - D I R E C T I O N

STORY NAME PRESSURE ELEV.


LOADED LOADED WIND ADDED STORY STORY OVERTURN`G
HEIGHT BREADTH FORCE FORCE FORCE SHEAR MOMENT
---------- -------- ------- ------- ------- ---------- ---------- ---------- ---------- ----------
Roof 3.064116 12.5 1.5 25.0 114.90433 0.0 0.0 0.0 0.0
4F 3.064116 9.5 3.0 25.0 224.47603 0.0 0.0 0.0 0.0
3F 2.921912 6.5 3.0 25.0 212.42555 0.0 0.0 0.0 0.0
2F 2.742769 3.5 3.25 25.0 216.30466 0.0 0.0 0.0 0.0
G.L. 2.593161 0.0 1.75 25.0 113.45081 0.0 -- 0.0 0.0
--------------------------------------------------------------------------------------------------

W I N D L O A D G E N E R A T I O N D A T A RZ - D I R E C T I O N

STORY NAME TORSIONAL ELEV. LOADED LOADED WIND ADDED STORY ACCUMULATED
PRESSURE HEIGHT BREADTH TORSION TORSION TORSION TORSION
---------- --------- ------- ------- ------- ---------- ---------- ---------- -----------
Roof 0.0 12.5 1.5 9.05 0.0 0.0 0.0 0.0
4F 0.0 9.5 3.0 9.05 0.0 0.0 0.0 0.0
3F 0.0 6.5 3.0 9.05 0.0 0.0 0.0 0.0
2F 0.0 3.5 3.25 9.05 0.0 0.0 0.0 0.0
G.L. 0.0 0.0 1.75 9.05 0.0 0.0 -- 0.0
-----------------------------------------------------------------------------------------

===========================
ECCENTRICITY RELATED DATA
===========================

STORY STORY STORY ACCIDENTAL ACCIDENTAL ACCIDENTAL ACCIDENTAL


NAME FORCE(X) FORCE(Y) ECCENT.(X) ECCENT.(Y) TORSION(X) TORSION(Y)
---------- ---------- ---------- ---------- ---------- ---------- ----------

Modeling, Integrated Design & Analysis Software Print Date/Time : 05/11/2024 23:03
Gen 2021
midas Gen -2/3-
PROJECT TITLE : http://www.MidasUser.com

Company Client
Author File Name final na talaga tangina.wpf

Roof 33.976327 0.0 0.0 0.0 0.0 0.0


4F 66.02224 0.0 0.0 0.0 0.0 0.0
3F 61.659965 0.0 0.0 0.0 0.0 0.0
2F 61.794366 0.0 0.0 0.0 0.0 0.0
G.L. -- -- 0.0 0.0 -- --