8103 M-36 6u2232351 Er Vent Fans
8103 M-36 6u2232351 Er Vent Fans
P-2
1. PLAN HISTORY
P-3
2. PAINTING SPECIFICATION
HI AIR KOREA Co., Ltd.
P-5
HI AIR KOREA Co., Ltd.
P-6
P-7
4. FAN SPECIFICATION
℃
DESIGN 2011-09-16 A4
CHECKED 2011-09-16 CATEGORY PART NO. SEET
MGR APPR - 1/1
P-32
HI AIR KOREA Co., Ltd.
P-33
HI AIR KOREA Co., Ltd.
P-34
P-35
DETAIL "A"
PANEL
P-41
P-42
P-43
P-44
P-45
P-46
P-47
P-48
P-49
CH0
CH1
CH2
CH3
CH0
CH4
CH1
CH5
CH2
CH6
CH3
CH7
P-50
P-51
P-52
P-53
P-54
P-55
P-56
P-57
P-58
P-59
P-60
P-61
P-62
P-63
P-64
P-65
P-66
P-67
P-68
P-69
P-70
P-71
P-72
P-73
KEY POINTS
- Ranges from -100/+100 Pa to -10000/+10000 Pa (according to models)
- Configurable intermediary ranges
- 0-10 V or 4-20 mA output, active, power supply 24 Vac/Vdc (3-4 wires) or 4-20 mA
output, passive loop, power supply from 16 to 30 Vdc (2 wires)
- ABS V0 housing, IP65, with or without display
- “¼ turn” system mounting with wall-mount plate
- Housing with simplified mounting system
- Solenoid valve for auto-calibration (only on CP111 model)
Weight : 143 g
TECHNICAL FEATURES
Measurement units Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
Accuracy* CP111 : ±1% of reading ±2 Pa ; CP112 : ±1.5% of reading ±3 Pa ; CP113 : ±1.5% of reading ±3 mmH2O
Autozero Manual with push-button ; Automatic by solenoid valve (only on CP111 model)
Type of fluid Air and neutral gases
Overpressure tolerated CP111/112 : 21 000 Pa – CP113 : 69 000 Pa
Operating temperature From 0 to +50 °C
Storage temperature From -10 to +70 °C
*All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation.
PART NUMBER
To order, just add the codes to complete the part number : Example : CP 113 – AO
Pressure transmitter measuring range -10 000/+10 000 Pa,
CP 11 0-10 V or 4-20 mA active, with display
Display
Measuring range O : with display
1 : -100/+100 Pa N : without display
2 : -1000/+1000 Pa
3 : -10 000/+10 000 Pa Power supply / Output
A : Active – 24 Vac/Vdc – 0-10 V or 4-20 mA
P : Passive – 16/30 Vdc – 4-20 mA
P-76
TECHNICAL SPECIFICATIONS
Output / Supply - active sensor 0-10 V or 4-20 mA (alim. 24 Vac/Vdc ± 10%), 3-4 wires
- passive loop 4-20 mA (power supply 16/30 Vdc), 2 wires
- maximum load : 500 Ohms (4-20 mA)
- minimum load : 1 K Ohms (0-10 V)
Consumption 2 VA (0-10 V) or max. 22 mA (4-20 mA)
Electromagnetical compatibility EN61326
Electrical connection Screw terminal block for cables Ø0.05 to 2.5 mm2
Communication to PC Kimo USB-mini Din cable
Environment Air and neutral gases
CONNECTIONS
Inside the front housing Fixed back housing
Removable front face
This connection must be made by a qualified technician. To make the connection, the transmitter must not be energized.
For CP111/112/113 – AO models and CP111/112/113 – AN To make a 3-wire connection, before powering up the
models with 0-10 V or 4-20 mA output – active, 4 wires : transmitter, please connect the output ground to the
input ground. See drawing below.
VP GND IP
+ - + - +
1 2 3 4 5 6 7 VP GND IP
+ - + - +
1 2 3 4 5 6 7
GND IP
- + N L
4
wires 4 5 6 7
3 wires
+ -
V - + + -
Regulator display or
Power supply + L
PLC/BMS V - Power supply or N Power supply
passive type 24 Vdc
0-10 V output Regulator display or 24 Vdc 24 Vac
or
PLC/BMS passive type class II
or - + N L 0-10 V output
6 7 or -
A +
Regulator display or
A
PLC/BMS active type
Regulator display or PLC/BMS
4-20 mA output active type
N L
4-20 mA output
Power supply
24 Vac
4 wires class II 3 wires
P-77
For CP112/113 – PO models and CP112/113 – PN models with 4-20 mA output – passive :
7
Vdc + Display/regulator/PLC
7
A passive type or
2 wires IP - 2 wires A 16-30 Vdc
6
IP - -
6
5
5
2 wires
...
...
...
...
To configure the transmitter, it must not be energized. Then, you can make the settings required, with the DIP switches (as shown on the
drawing below). When the transmitter is configured, you can power it up.
On-off switch
To configure the transmitter, unscrew the 4 1 Measuring
1 Output setting
screws from the housing then open it. DIP 2 ranges setting 2
switches allowing the different settings are
3 3 Units setting
then accessible.
4 Standard range or 4
central 0 setting
Left DIP switch Right DIP switch
➢ Measuring range settings – left DIP switch
To set a measuring range, put the 1, 2 and 3 on-off switches as indicated in the table below.
1 1 1 1 1
2 2 2 2 2
3 3 3 3 3
4 4 4 4 4
Combination 1 Combination 2 Combination 3 Combination 4 Combination 5
Type of
CP111 CP112 CP113 CP111 CP112 CP113 CP111 CP112 CP113 CP111 CP112 CP113 CP111 CP112 CP113
transmitter
Pa 20 100 1000 30 250 2500 40 500 5000 50 750 7500 100 1000 10000
mmH2O 2.0 10.0 100.0 3.0 25.0 250.0 4.0 50.0 500 5.0 75.0 750.0 10.0 100.0 1000.0
mbar 0.2 1 10.00 0.3 2.5 25.00 0.4 5.0 50.00 0.5 7.5 75.00 1.00 10.00 100.00
inWG 0.08 0.40 4.00 0.12 1.00 10.00 0.16 2.00 20.00 0.20 3.00 30.00 0.40 4.00 40.00
mmHg 0.20 0.80 8.00 0.22 2.00 20.00 0.30 4.00 40.00 0.40 6.00 60.00 0.80 8.00 80.00
daPa 2.0 10.0 100 3.0 25.0 250.0 4.0 50.0 500.0 5.0 75.0 750.0 10.0 100.0 1000.0
kPa 0.020 0.100 1.00 0.030 0.250 2.50 0.040 0.500 5.00 0.050 0.750 7.50 0.100 1.000 10.00
hPa 0.20 1.00 10.00 0.30 2.50 25.00 0.40 5.00 50.00 0.50 7.50 75.00 1.00 10.00 100.00
●
Measuring ranges of the CP111 transmitter on the ±100 Pa range according to the measurement unit
●
Measuring ranges of the CP112 transmitter on the ±1000 Pa range according to the measurement unit
●
Measuring ranges of the CP113 transmitter on the ±10 000 Pa range according the the measurement unit.
Example :
● From 0 to 750 mmH O, measuring range is 750 mmH O.
2 2
●
From -500 Pa to +500 Pa, measuring range is 1000 Pa.
P-78
➢ Standard range / central zero setting – left DIP switch
Configurations Full scale Central zero
To set the type of measuring range, put the on-off switch 4 as indicated beside :
Example 0-100 Pa : Full scale / 0 (0 / 100 Pa)
Central zero (-50 Pa / 0 / +50 Pa) Combinations
Please follow carefully the combinations beside with the DIP switch. If the combination is wrongly done, the following message will appear
on the display of the transmitter “CONF ERROR”. In that case, you will have to unplug the transmitter, place the DIP switches correctly, and
then power the transmitter up.
➢ Output setting – right DIP switch (CP111/112/113 – AO and CP111/112/113 – AN models)
To set the type of analogue output, please put the on-off switch of the output as shown Configurations 4-20 mA 0-10 V
FTang – transmitter_CP111-112-113 – 14/06/13 – RCS (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
beside. 1 1
2 2
Combinations
3 3
4 4
➢ Units setting – right DIP switch
To set a measurement unit, put the on-off switches 2, 3 and 4 of the units as shown in the table below .
Insert the transmitter on the fixing plate (see A on the drawing beside). Rotate the housing in
clockwise direction until you hear a “click” which confirms that the transmitter is correctly installed. 8 mm
A
50 mm
Once the transmitter is installed and powered up, please make an autozero to
68 mm
7.5 mm
MAINTENANCE
Please avoid any aggressive solvent. Please protect the transmitter and its probes from any cleaning product containing formalin, that may be used for cleaning
rooms or ducts.
OPTIONS AND ACCESSORIES
●
KIAL-100A : Power supply class 2 , 230 Vac input, 24 ●
Connection tube ●
Straight connections
Vac output ●
Connection fittings ●
Spherical coupling nut
●
LCC-S : configuration software with USB cable ●
Through-connections
P-79
TEMPERATURE SENSOR
NP1
NP2
DETAIL
Temperature transmitter
TM 110
KEY POINTS
- Range from 0 to 50 °C (ambient model), from -20 to +80 °C (duct and air tight models) and from
-100 to 400 °C (model with Pt100 terminal block)
- 0-10 V output, active, power supply 24 Vac/Vdc (3-4 wires) or 4-20 mA output, passive loop,
power supply from 16 to 30 Vdc (2 wires)
- ABS V0 housing, IP65 (remote, air tight and duct models) or IP20 (ambient model), with or without
display
- “¼ turn” system mounting with wall-mount plate
- Housing with simplified mounting system
Ambient model Duct model, stainless steel probe* Material : ABS V0 as per UL94
41 mm 90 mm 46 mm 150 mm 90 mm
Protection :
- duct and air tight models and model
80 mm
109 mm
Ø6 mm
- ambient model : IP20
109 mm
Weight : 162 g
Air tight model Cable of remote probes : length 2 m and
46 mm 90 mm
Ø 4.8 mm in PVC
109 mm
PART NUMBER
To order, just add the codes to complete the part number :
TM110
TECHNICAL FEATURES
Unit of measurement °C, °F
Measuring range From 0 to 50 °C (ambient model), form -20 to +80 °C (duct and air tight models) and from -100 to +400 °C
(model with terminal block)
Accuracy* Pt100 : ±0.5 % of reading ±0.5 °C
NTC : ±0.3°C (from -40°C to 70°C) ; ±0.5°C (outside the -40 to +70°C temperature range)
Type of sensor Pt100 (model with terminal block and stainless steel duct and air tight models)
NTC (ambient model and duct model)
Response time 1/e (63%) 5 sec. (ambient)
1/e (63%) 20 sec. (airtight)
Resolution 0.1 °C
Type of fluid Air and neutral gases
Operating temperature From 0 to +50 °C
Storage temperature From -10 to +70 °C
*
All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation.
TECHNICAL SPECIFICATIONS
Output / Power supply - active sensor 0-10 V (power supply 24 Vac/Vdc ± 10%), 3-4 wires
- passive loop sensor 4-20 mA (power supply 16/30 Vdc), 2 wires
- maximum load : 500 Ohms (4-20 mA)
- minimum load : 1 K Ohms (0-10 V)
Consumption 2 VA (0-10 V) or max. 22 mA (4-20 mA)
Electromagnetical compatibility EN61326
Electrical connection Screw terminal block for cables Ø0.05 to 2.5 mm 2
PC communication Kimo USB-mini Din cable
Environment Air and neutral gases
CONNECTIONS
1 2 2'
P-83
ELECTRICAL CONNECTIONS – as per NFC15-100 standard
This connection must be made by a qualified technician. To make the connection, the transmitter must not be energized.
For TM110 – AO and TM110 – AN models with 0-10 V output – active, 4 wires :
To make a 3-wire connection, before powering up the transmitter,
please connect the output ground to the input ground. See
drawing below.
GND VT
- + - +
1 2 3 4 5 6 7 GND VT
- + - +
1 2 3 4 5 6 7
GND
4 - N L
wires 4 5 6 7
3 wires
- +
V - + - +
Display/regulator/PLC Power supply + L
passive type 24 Vdc
V
Power supply or N Power supply
0-10 V output - 24 Vdc 24 Vac
or
class II
N L Display/regulator/PLC
6 7 passive type
0-10 V output
N L
4 wires 3 wires
Power supply
24 Vac
class II
- + 2 wires A
16-30 Vdc
IT - 2 wires Display/regulator/
or IT - -
6
6
-
4
2 wires
To configure the transmitter, it must not be energized. Then, you can make the settings required, with the DIP switches (as shown on the
drawing below). When the transmitter is configured, you can power it up.
On-off switch
1
2 Measuring range
setting
3
Unit of measurement
4 setting
➢ Measuring range setting
To set a measuring range, put the on-switches 1, 2 and 3 of the measuring ranges as shown below.
Configurations From 0 to 50 °C From -20 to +80 °C From -50 to +50 °C From 0 to 100 °C From 0 to 200 °C From 0 to 400 °C
1 1 1 1 1 1
2 2 2 2 2 2
Combinations
3 3 3 3 3 3
4 4 4 4 4 4
P-84
➢ Unit of measurement setting Configurations °C °F
To set the unit of measurement, put the on-off switch 4 as show beside. 1 1
2 2
Combinations
3 3
4 4
Caution : the minimum difference between the high range and the low range is 20.
FTang – transmitter_TM110 – 23/07/13 – RCS (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Example : for a 0-100°C transmitter, the minimum delta of the range is 20°C. It is then possible to 1
configure the transmitter from 0 to +100°C, or from 0 to +20°C... 2
• To access the configuration via software : 3
- Set the DIP switches as shown beside. 4
- Connect the cable of the LCC-S to the connection of the transmitter. Switch
• Please refer to the user manual of the LCC 100 to make the configuration.
The configuration of the parameters can be done either with the DIP switch or via software (you can not combine both
solutions).
75 mm
MOUNTING 37.5 mm
40 mm
To install the transmitter, mount the ABS plate on the wall (drilling : Ø6 mm,
23.75 mm
50 mm
68 mm
14 mm 4.5 mm
Ambient model does not have any mounting plate.
4 fixing holes are present inside the back housing. Use them to install A
the transmitter on the required location.
7.5 mm
MAINTENANCE
Please avoid any aggressive solvent. Please protect the transmitter and its probes from any cleaning product containing formalin, that may be
used for cleaning rooms or ducts.
Caution : the minimum difference between the high range and the low range is 20.
FTang – transmitter_TM110 – 23/07/13 – RCS (24) Périgueux 349 282 095 Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
Example : for a 0-100°C transmitter, the minimum delta of the range is 20°C. It is then possible to 1
configure the transmitter from 0 to +100°C, or from 0 to +20°C... 2
• To access the configuration via software : 3
- Set the DIP switches as shown beside. 4
- Connect the cable of the LCC-S to the connection of the transmitter. Switch
• Please refer to the user manual of the LCC 100 to make the configuration.
The configuration of the parameters can be done either with the DIP switch or via software (you can not combine both
solutions).
75 mm
MOUNTING 37.5 mm
40 mm
To install the transmitter, mount the ABS plate on the wall (drilling : Ø6 mm,
23.75 mm
50 mm
68 mm
14 mm 4.5 mm
Ambient model does not have any mounting plate.
4 fixing holes are present inside the back housing. Use them to install A
the transmitter on the required location.
7.5 mm
MAINTENANCE
Please avoid any aggressive solvent. Please protect the transmitter and its probes from any cleaning product containing formalin, that may be
used for cleaning rooms or ducts.
Performance Curve
Version : 4.4.0.2
Performance Curve
Version : 4.4.0.2
Performance Curve
Version : 4.3.4.23
Total Pressure(mmAq)
26
24
22
20
18
16
14
12
10
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34
Air Volume(CMM)
Shaft Power(kW)
0.200
0.180
0.160
0.140
0.120
0.100
0.080
0.060
0.040
0.020
0.000
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34
Air Volume(CMM)
P-92
P-93
P-94
P-95
8. TEST REPORT
P-96
FAN
Type HWA-2000/800 Sys. No. S101
Ps 55 mmAq Q'ty 1 st
Fan served No.1 ENGINE ROOM SUP. (NON-REVERSIBLE)
MOTOR
Maker HHI Type 280S-8
Output 55.0 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. F0178272L10005001 IP 56
* TEST RESULT
SPEC. ACT'
Velocity (m/s) 15.9 16.2
Air volume (㎥/min) 3,000 3,054
Rating Current (A) 98.9 72.4
R.P.M. 885 896
S.P.L dB(A) 103.0 99.8
Megger (MΩ) 10 ↑ 2,000
Vibration (mm/s) Below 2.8 1.5
Remarks
* Test Duct Dia. : 2,000 mm
* Air volume = Velocity × Duct area
*Tolerance of S.P.L +4 dB(A)
- According to DIN 24166
*Vibration : ~3.7kW , 3.5mm/s(RMS)
3.7kW~ , 2.8mm/s(RMS) According to ISO 14694
FAN
Type HWA-2000/800 Sys. No. S102
Ps 55 mmAq Q'ty 1 st
Fan served No.2 ENGINE ROOM SUP. (REVERSIBLE)
MOTOR
Maker HHI Type 280S-8
Output 55.0 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. F0178272L10005002 IP 56
* TEST RESULT
SPEC. ACT'
Velocity (m/s) 15.9 16.5
Air volume (㎥/min) 3,000 3,110
Rating Current (A) 98.9 71.6
R.P.M. 885 893
S.P.L dB(A) 103.0 98.4
Megger (MΩ) 10 ↑ 2,000
Vibration (mm/s) Below 2.8 1.5
Remarks
* Test Duct Dia. : 2,000 mm
* Air volume = Velocity × Duct area
*Tolerance of S.P.L +4 dB(A)
- According to DIN 24166
*Vibration : ~3.7kW , 3.5mm/s(RMS)
3.7kW~ , 2.8mm/s(RMS) According to ISO 14694
FAN
Type HWA-2000/800 Sys. No. S103
Ps 55 mmAq Q'ty 1 st
Fan served No.3 ENGINE ROOM SUP. (NON-REVERSIBLE)
MOTOR
Maker HHI Type 280S-8
Output 55.0 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. F0178272L10005003 IP 56
* TEST RESULT
SPEC. ACT'
Velocity (m/s) 15.9 16.5
Air volume (㎥/min) 3,000 3,110
Rating Current (A) 98.9 71.3
R.P.M. 885 894
S.P.L dB(A) 103.0 99.6
Megger (MΩ) 10 ↑ 2,000
Vibration (mm/s) Below 2.8 1.7
Remarks
* Test Duct Dia. : 2,000 mm
* Air volume = Velocity × Duct area
*Tolerance of S.P.L +4 dB(A)
- According to DIN 24166
*Vibration : ~3.7kW , 3.5mm/s(RMS)
3.7kW~ , 2.8mm/s(RMS) According to ISO 14694
FAN
Type HWA-2000/800 Sys. No. S104
Ps 55 mmAq Q'ty 1 st
Fan served No.4 ENGINE ROOM SUP. (REVERSIBLE)
MOTOR
Maker HHI Type 280S-8
Output 55.0 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. F0178272L10005004 IP 56
* TEST RESULT
SPEC. ACT'
Velocity (m/s) 15.9 16.2
Air volume (㎥/min) 3,000 3,054
Rating Current (A) 98.9 72.4
R.P.M. 885 895
S.P.L dB(A) 103.0 99.0
Megger (MΩ) 10 ↑ 2,000
Vibration (mm/s) Below 2.8 1.8
Remarks
* Test Duct Dia. : 2,000 mm
* Air volume = Velocity × Duct area
*Tolerance of S.P.L +4 dB(A)
- According to DIN 24166
*Vibration : ~3.7kW , 3.5mm/s(RMS)
3.7kW~ , 2.8mm/s(RMS) According to ISO 14694
FAN
Type AKA-710/350 Sys. No. E105
Ps 45 ㎜Aq Q'ty 1 st
Fan served PURIFIER ROOM EXH. FAN (NON-REV.)
MOTOR
Maker HYUNDAI Type 132M-4
Output 7.5 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. F0221654L10008001 IP 54
* TEST RESULT
SPEC. ACT
Velocity (m/s) 15.8 16.1
Air volume (㎥/min) 375 382
Rating Current (A) 14.6 11.4
R.P.M. 1,740 1,776
S.P.L dB(A) 87.0 86.2
Megger (MΩ) 10 ↑ 2,000
Remarks
FAN
Type PVA-12C4 Sys. No. E106
Ps 10 ㎜Aq Q'ty 1 st
Fan served WELDING SPACE EXH. FAN
MOTOR
Maker HHI Type 71M-4
Output 0.4 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. F0221655L10004001 IP 54
* TEST RESULT
SPEC. ACT
Velocity (m/s) 2.0 2.1
Air volume (㎥/min) 15 16
Rating Current (A) 1.2 0.8
Megger (MΩ) 10 ↑ 2,000
Remarks
9. INSTRUCTION MANUAL
P-103
P-104
P-105
P-106
P-107
P-108
P-109
P-110
P-111
P-112
P-113
P-114
P-115
P-116
P-117
P-118
P-119
P-120
P-121
P-122
P-123
P-124
P-125
P-126
P-127
P-128
P-129
P-130
P-131
P-132
P-133
P-134
P-135
P-136
P-137
P-138
P-139
P-140
P-141
P-142
P-143
P-144
P-145
P-146
P-147
P-148
P-149
P-150
P-151
P-152
P-153
P-154
P-155
P-156
P-157
P-158
P-159
P-160
P-161
P-162
P-163
P-164
P-165
P-166
P-167
P-168