Professional Documents
Culture Documents
Kyenjojo - Kihuura Secondary School
Kyenjojo - Kihuura Secondary School
xlsx
MAIN SUMMARY
SUB-TOTAL 1
TOTAL AMOUNT
767670138.xlsx
BILL NO 1
PRELIMINARIES
767670138.xlsx
Contract Particulars
A. General
B. Time Control
C. Quality Control
D. Cost Control
General matters
L General foreman
Page 116of 2
767670138.xlsx
D Occupation Certificate
Temporary Works
H General scaffolding
COLLECTION
Page 1 of 2 -
Page 2 of 2 -
Page 117of 2
767670138.xlsx
BILL NO 1A
The Contractor shall prepare and submit in ample time for approval before
execution of the Works detail drawings, specifications and calculations of all
temporary Works they may wish to use, which shall also show the location of
such temporary Works and their order of execution
SITE CLEARANCE
Clear site of all anti hills, bushes, shrubs and under growth and cutting down trees
A not exceeding 1500mm girth, including grubbing up roots and removing away SM 2,300
from site
EXCAVATIONS
Mass excavation to reduce levels commencing from stripped level not exceeding
B CM 4,650
1.5m deep; deposit in temporary spoil heaps on site.
C Load from spoil heaps and cart away surplus material from site as guided by client CM 280
1A/1
767670138.xlsx
ELEMENT NO.1
EARTH WORKS
SUMMARY
1A/S
767670138.xlsx
BILL NO.2
2-CLASSROOM BLOCK
COLLECTION
Total brought forward from Page 2/1/1
Total brought forward from Page 2/1/2
BLOCK WORK
Solid Concrete blockwork jointed and pointed in cement sand (1:3)
mortar with and including hoop iron wall ties every alternative course
: in
B 200mm Thick walls 154 SM
C 150mm Thick walls 2 SM
D Labour and material eaves filling: 200mm walls average 225mm 61 LM
150mm HARD BURNT CLAY VENT BRICKS to BS 3921
(3.5N/mm2 compressive strength) bedded, jointed and pointed in
cement and sand (1:4) mortar and painted in coloured cement
E Vent bricks 12 SM
DAMP PROOF COURSE OF BITUMEN FELT TO B.S 743 Type A
with 150mm laps including cement and sand (1:3) levelling bed
F 200mm Wide 55 LM
G 150mm wide 2 LM
A Filler blocks 20 LM
RAIN WATER DISPOSAL
COLLECTION
2/4/2
D Steel windows 43 SM
E Burglar proof 43 SM
2-CLASSROOM BLOCK
ELEMENT NO.8
FLOOR FINISHES
D 200mm thick walling to sides of splash Apron with and including 450 x 26 LM
150mm foundation concrete; finished with steel float to exposed
surfaces; necessary excavation and disposal of surplus soil.
2/8/1
A Open Shelving overall 5700mm Long x 400mm Wide x 2100mm high; 2 No.
to Architect's detailed drawing
B Students' bench and desk overall size 1500mm long x 920mm wide x 40 NO
770mm high
TEACHER'S TABLES
SUPPLY TEACHER'S TABLES COMPRISING OF: 25mm thick
sanded and vanished hardwood timber screwed to 25x25x2mm thick
steel frame complete with 25x25x2mm bearing; 25x25x2mm thick
steel bracing; 25x25mm approved rubber /plastic shoe at the bottom;
25mm thick hard wood drawers with 6mm thick plyboard base in the
frame complete with runners including all necessary ironmongery
and accessories, painting and decorations as per Architect's detailed
drawing FDet - 05
COLLECTION
Total Carried Forward From Page 2/9/1
Total Carried Forward From Page 2/9/2
All power supply cables measured under this Bills of Quantities have
provisional route length stated. Actual measurements will be done on
site during evaluation.
The rate for the underground cables shall cover excavation, sand-
bedding, backfilling, trenching, enclosing in PVC ducts, where
necessary, and all associated builders' works. Actual measurements
shall be based on the site conditions.
All indoor cables are to recessed within the cable ducts, ceiling voids,
wall fabric enclosed in suitably sized PVC conduits neatly installed
and to further Instructions from the Electrical Engineer and/or
Drawings.
TO COLLECTION
Distribution boards
B Metalcased and Lockable 100A, 6-Way Low Voltage (240) SPN MCB- 1 NO
type Consumer Unit for power supply c/w 100A DP Mains isolator, SP
MCBs, Busbars, and all other accessories as per drawings to Memshield
manufacture. The rate includes accurate labelling of all loads connected
accordingly to the Board.
TO COLLECTION
2/10/2
LIGHTNING PROTECTION
All items are to be supplied and installed complete with all the
required mounting, fixing, clipping, testing including connecting
accessories. All to be tested and commissioned to the satisfaction of
the Electrical Engineer.
Supply, install, connect and set to work the following, all as described
in the specifications and drawings
B All items are to be supplied and installed complete with all the required
mounting, fixing, clipping, testing, connecting accessories, connected,
tested and commissioned to the satisfaction of the Electrical Engineer.
TO COLLECTION
COLLECTION
Total Carried Forward From Page 2/10/1
Total Carried Forward From Page 2/10/2
Total Carried Forward From Page 2/10/3
TO SUMMARY
2/10/3
AMOUNT
ELEMENT DESCRIPTION PAGE NO (USHS)
BILL NO.2
2-CLASSROOM BLOCK
SUMMARY
1 SUBSTRUCTURES 2/1/2
3 WALLING 2/3/1
5 DOORS 2/5/2
6 WINDOWS 2/6/1
2/S
BILL NO.3
Q Column bases 3 CM
R Stub Columns 1 CM
S Ground Beam 5 CM
T Ditto; but in Ramp size 6000 x 1500 x 250mm Thick (average) 5 CM
U 125mm thick ground floor slab 231 SM
V 200mm x 250mm x 75mm thick Concrete downstand for storm water channel 75 LM
COLLECTION
Total brought forward from Page 3/1/1
Total brought forward from Page 3/1/2
A Ring beams 4 CM
B Beams 2 CM
C Columns 2 CM
D Lintel 1 CM
E Ditto : But 75mm thick Gas cage Suspended slab 2 SM
STEEL REINFORCEMENT as described including cutting to length, bending,
hoisting and fixing and including all necessary tying wire and spacing blocks
FORMWORK TO:
I Sides and Soffittes of horizontal suspended solid slabs 2 SM
J Sides and soffittes of ring beams 44 SM
K Sides and soffittes of beams 16 SM
L Sides of columns 45 SM
M Edges of suspended slab 5 LM
SUNDRIES
N 20 SWG Hoop Iron wall tie 25mm wide x 450mm long cast 75mm into concrete and 300 NO
built into joint of blockwalling.
GALVANISED STEEL PIPES
O 75mm diameter x 2mm thick Round Hollow Section: Height 2800mm long including 10 NO
700mm length bedded in concrete in ground : top welded with 2mm thick U-shaped
mild steel cleat supporing a 60x40x3mm RHS wall plate 22000mm long: bottom
welded with fixing lugs: primed with one coat red oxide primer before fixing: includes
excavation, backfill, complete
A Filler blocks 23 LM
RAIN WATER DISPOSAL
COLLECTION
3/4/2
A Door D03 overall Size 900 x 2400mm high with and including 4mm thick clear sheet 5 NO
glass and fixed glazing panel 300mm high above transom
F General surfaces 19 SM
G Surfaces 100 - 300mm girth 31 LM
H Surfaces not exceeding 100mm girth 72 LM
I Prime back of surfaces of frames before fixing 31 LM
Supply and fix the following ironmongery : locks and furniture where applicable are
to be equal to those manufactured by "UNION" and approved by the Architect
J 100mm long stainless steel 2Ball Bearing Butt hinges complete with screws 7.5 PRS
K Stainless steel Lever handles with and including 1 pair of CB escutcheons 5 PRS
3/5/1
COLLECTION
Total Carried Forward From Page 3/5/1
Total Carried Forward From Page 3/5/2
F Steel windows 49 SM
G Burglar proof 49 SM
B Ceiling 24 SM
C 150 x 150mm Coved Cornice 28 LM
D Extra over ceiling for trap door 1 NO
ELEMENT NO.9
FLOOR FINISHES
A Floors 231 SM
CEMENT AND SAND (1:3)
B 150 x 25mm Skirting : square top and coved junction at bottom 87 LM
SPLASH APRON
C 125mm thick concrete class 20/20mm aggregate splash reinforced with and including 39 SM
fabric mesh reinforcement ref A98 as before described; including Gauge 1000 DPM
and 200mm Thick Hardcore Blinded with Stone dust and all necessary formwork.
D 200mm thick walling to sides of splash Apron with and including 450 x 150mm 70 LM
foundation concrete; finished with steel float to exposed surfaces; necessary excavation
and disposal of surplus soil.
3/9/1
G Apply one coat undercoat and two finishing coats of matt emulsion paint on concrete 14 LM
chalk rail surfaces not exceeding 100mm girth.
Portable Fire Extinguisher
H Supply and install 9kg Carbon Dioxide Fire extinguisher cylinder mounted on 4 NO
hangers/brackets secured into 230mm wall: Top of Fire Extinguisher not exceeding
1.20m above floor surface
A Low level Worktop unit overall size 600mm wide x 900mm high 48 LM
B Ditto; Low Level Worktop Unit overall size 800mm Wide x 900mm high 4 LM
FUME CUPBOARDS
FUME CUPBOARDS COMPRISING OF: 100x75mm hardwood frame; with 13mm
wide sliding glove; 25mm thick hardwood shutters with concealed hinges
comprising of 5mm thick clear sheet glass in 25x25mm hardwood glazing beads; 50
x 50mm hardwood timber bearers, 25mm blockboard on top complete with 200mm
dia gauge 24 galavanised iron pipe fume cupboard vent; complete with and
including all iron mongery, and all necessary accessories to "Union Manufacture or
approved equal"; as per Architect's Drawings LAB/DET/12 & 13
C Fume cupboard unit overall size 1500mm long x 700mm Wide x 1400mm high; to 2 NO
Architect's detailed drawing
OPEN SHELVES
300mm Wide open shelves Comprising 25mm thick sanded and vanished handwood;
supported on the 38 x 50mm hardwood backing complete with 200 x 200mm mild
steel brackets screwed onto the 38x50mm hardwood runner, including all necessary
accessories, painting and decorations per Architect's detailed drawing LAB/DET/18
E Shelving overall 3300mm Long x 300mm Wide x 1100mm high; to Architect's detailed 2 NO
drawing
D Aloow a Provisional Sum Uganda Shillings 1,000,000 (One Million Uganda Shillings) 1 Item
Furniture Engraving
COLLECTION
Total Carried Forward From Page 3/10/1
Total Carried Forward From Page 3/10/2
Total Carried Forward From Page 3/10/3
All underground reticulation and distribution cables are to be supplied and installed
c/w all necessary fixing / clipping / supporting / glanding and termination
accessories as per general specification and type approved by the supervising
Electrical Engineer
The rate for the underground cables shall cover excavation, sand-bedding,
backfilling, trenching, enclosing in PVC ducts, where necessary, and all associated
builders' works. Actual measurements shall be based on the site conditions.
All indoor cables are to recessed within the cable ducts, ceiling voids, wall fabric
enclosed in suitably sized PVC conduits neatly installed and to further Instructions
from the Electrical Engineer and/or Drawings.
All lighting fittings shall be as per Specifications and Drawings with control gear
compartible with 240V/50Hz. All lighting fittings are to be approved by the Electrical
Engineer prior to installation.
All Fire Detection and Alarm System elements are to be to fully addressable to Gent
Vigilon System Architecture, or otherwise approved.
All wiring accessories shall be as per original Legrand Specifications and Drawings
(or otherwise specificied and approved) complete with all attachments and
accessories. All samples to be approved prior to installation by the Engineer.
The entire electrical installation shall be tested for compliance in accordance to the
16th Edition of the IEE Wiring Regulations and witnessed / approved by the
Engineer
TO COLLECTION
3/11/1
Distribution boards
B Metalcased and Lockable 100A, 6-Way Low Voltage (240) SPN MCB-type Consumer 1 NO
Unit for power supply c/w 100A DP Mains isolator, SP MCBs, Busbars, and all other
accessories as per drawings to Memshield manufacture. The rate includes accurate
labelling of all loads connected accordingly to the Board.
I Outdoor Hard-Wired Post Eye Light Control Electric Resistor Photocell Light Sensor, 1 NO
as to LEGRAND or equivalent.
WIRING and CONDUITING:
Lighting points:
J All wiring of lighting points are to be connected complete and ready from 10A SP 18 NO
miniature circuit breakers, using 3x2.5mm sq. PVC-Insulated single core copper cables
drawn in a 25mm PVC concealed conduits, through switches, and as per drawings.
TO COLLECTION
3/11/2
LIGHTNING PROTECTION
All items are to be supplied and installed complete with all the required mounting,
fixing, clipping, testing including connecting accessories. All to be tested and
commissioned to the satisfaction of the Electrical Engineer.
Supply, install, connect and set to work the following, all as described in the
specifications and drawings
B 25mm x 3mm copper tape as to FURSE manufacture, or approved equivalent. 40 L/m
C 25mm x 3mm copper square test clamp, as to FURSE Cat.No. CT 105, or approved 2 No.
equivalent.
D 2000mm x 15mm air rod, as to FURSE Cat. No. RA 240 c/w multiple point, as to 1 No.
FURSE Cat. No. RA 600, air terminal base, as to FURSE Cat. No. SD 105, and ridge
saddle, as to FURSE Cat. No. SD 115, or approved equivalent.
TO COLLECTION
COLLECTION
Total Carried Forward From Page 3/11/1
Total Carried Forward From Page 3/11/2
Total Carried Forward From Page 3/11/3
TO SUMMARY
3/11/3
M Fabricate and erect a metallic stand 3.0m high: Steel sections as indicated on 1 ITEM
Architectural drawings to mount 3000L Plastic water tank with ladder including
reinforced concrete foundation; excavation etc,painting with primer coat of lead oxide
and two coats of Aluminium Paint. Details to match Architectural Drawings.
N Supply and install Semi Rotary Hand Pump series K-5 Suction/Discharge of 1-1/2'', 1 ITEM
Capacity 85L per minute, maximum head 15m, maximum suction lift, 5m and
reciprocations of 72 per minute.
3/12/1
E Provide for the safety of harvested water: Approved sieve at the top 1 ITEM
TANK BASE
K Platform in concrete 3000mm diameter, 400mm high for mounting above tank. 1 NO
3/12/2
The Tenderers must allow in their prices for all couplings,connectors as required in
the running lengths of pipes
All Cold and Hot Water piping shall be PPR pipe PN25.Complete with
Tees,Sockets,Elbows,Threaded adapters,Threaded elbows,Reducers and all
associated fittings.
Laboratory sink
K Lightweight and superior in chemical resistance Lab sink as Lab Sink MS 505 Method 26 NO
make External dimensions (L x D x H): 552mm x 400mm x 235mm or equal approved
L 1 Way Water Lab Tap with PP Nozzle unit as SKU: PN 104 Method 26 NO
M Soap dish as Vado Elements ELE-182A-C/P 26 NO
3/12/3
C Allow a fee amount for paying to NWSC for connection to meter 1 ITEM
D 3,000litres PVC water tanks c/w tank stand 1 NO
EXTERNAL DRAINAGE SYSTEM- PIPES AND FITTINGS
E Excavation trench of size 600 wide by 600mm deep to lay drainage pipes 30 LM
H 300 x 300mm gulley trap with gulley piece, concrete surround, grating and 300mm x 4 NO
300mm cast iron cover
I Soak pit to structural engineer's detail 1 NO
CONCRETE DRAIN CHANNEL
J Concrete channel including 50mm thick pre-cast concrete cover; average depth 80 LM
150mm; in 150mm thick x 200mm wide base to a slope 1:50; sides in 150mm thick
class 20; all reinforced with BRC mesh on and including 50mm thick concrete blinding
inluding all necessary excavation and formwork
TO COLLECTION
COLLECTION
Total Carried Forward From Page 3/12/1
Total Carried Forward From Page 3/12/2
Total Carried Forward From Page 3/12/3
Total Carried Forward From Page 3/12/4
3/12/4
BILL No. 3
SUMMARY
1 SUBSTRUCTURES 3/1/2
3 WALLING 3/3/1
5 DOORS 3/5/2
6 WINDOWS 3/6/1
3/S
BILL NO.4
ADMINISTRATION BLOCK
COLLECTION
Total brought forward from Page 4/1/1
Total brought forward from Page 4/1/2
A Filler blocks 20 LM
RAIN WATER DISPOSAL
COLLECTION
4/4/2
A Door D02 overall Size 900 x 2400mm high with and including 4mm 3 NO
thick clear sheet glass and fixed glazing panel 300mm high above
transom
B Door D03 overall Size 800 x 2400mm high with and including timber 1 NO
4mm thick clear sheet glass and fixed glazing panel 300mm high
above transom
G General surfaces 15 SM
H Surfaces 100 - 300mm girth 30 LM
I Surfaces not exceeding 100mm girth 54 LM
J Prime back of surfaces of frames before fixing 23 LM
Supply and fix the following ironmongery : locks and furniture
where applicable are to be equal to those manufactured by
"UNION" and approved by the Architect
K 100mm long stainless steel 2Ball Bearing Butt hinges complete with 6.0 PRS
screws
L Stainless steel Lever handles with and including 1 pair of CB 4 PRS
escutcheons
M Double Profile cylinder 4 NO
N Polished aluminium (Anodised Silver Finished) Euro profile cylinder 8 NO
Escutcheon rings with concealed fixing
O Floor mounted Rubber door stop 4 NO
TOTAL CARRIED TO COLLECTION
COLLECTION
Total Carried Forward From Page 4/5/1
Total Carried Forward From Page 4/5/2
4/5/2
D Steel windows 51 SM
E Burglar proof 51 SM
A Ceiling 120 SM
B 150 x 150mm Coved Cornice 102 LM
C Extra over ceiling for trap door 1 NO
PREPARE AND APPLY THREE COATS first matt emulsion paint
D Metal Lath Plaster Ceiling 120 SM
E Surfaces not exceeding 100mm girth 102 LM
ADMINISTRATION BLOCK
ELEMENT NO.9
FLOOR FINISHES
D 200mm thick walling to sides of splash Apron with and including 450 26 LM
x 150mm foundation concrete; finished with steel float to exposed
surfaces; necessary excavation and disposal of surplus soil.
4/9/1
D Lockable shelves 15 NO
TEACHER'S CHAIR
SUPPLY TEACHER'S CHAIR COMPRISING OF: 25X25X2mm
think steel frame; 25x25x2mm steel bracing; 25x25mm approved
rubber /plastic shoe at the bottom; Complete with 450mm long x
180mm wide x25mm thick hardwood timber and 450mm long x
400mm wide x25mm think hardwood timber screwed to the steel
frame; including all necessary necessary accessories, painting and
decorations as per Architect's detailed drawing FDet - 03
COLLECTION
Total Carried Forward From Page 4/10/1
Total Carried Forward From Page 4/10/2
The rate for the underground cables shall cover excavation, sand-
bedding, backfilling, trenching, enclosing in PVC ducts, where
necessary, and all associated builders' works. Actual measurements
shall be based on the site conditions.
All indoor cables are to recessed within the cable ducts, ceiling
voids, wall fabric enclosed in suitably sized PVC conduits neatly
installed and to further Instructions from the Electrical Engineer
and/or Drawings.
TO COLLECTION
4/11/1
Distribution boards
B Metalcased and Lockable 100A, 6-Way Low Voltage (240) SPN 1 NO
MCB-type Consumer Unit for power supply c/w 100A DP Mains
isolator, SP MCBs, Busbars, and all other accessories as per drawings
to Memshield manufacture. The rate includes accurate labelling of all
loads connected accordingly to the Board.
TO COLLECTION
4/11/2
LIGHTNING PROTECTION
All items are to be supplied and installed complete with all the
required mounting, fixing, clipping, testing including connecting
accessories. All to be tested and commissioned to the satisfaction of
the Electrical Engineer.
TO COLLECTION
COLLECTION
Total Carried Forward From Page 4/11/1
Total Carried Forward From Page 4/11/2
Total Carried Forward From Page 4/11/3
TO SUMMARY
4/11/3
BILL NO.4
ADMINISTRATION BLOCK
SUMMARY
1 SUBSTRUCTURES 4/1/2
3 WALLING 4/3/1
5 DOORS 4/5/2
6 WINDOWS 4/6/1
8 CEILING 4/8/1
4/S
BILL NO.5
2-UNIT TEACHERS' HOUSE
A Allow for maintaining and upholding sides of excavation: clear off all fallen material, rubbish 1 ITEM
B Allow for keeping the whole of the excavation free from general water 1 ITEM
C Excavate top vegetable soil average 150mm deep and cart to spoil 0 SM
D Excavate to reduce levels not exceeding 1.50 metres deep and remove from site. 0 CM
Q Column bases 2 CM
R Stub Columns 1 CM
S Ground Beam 6 CM
U 125mm thick ground floor slab 99 SM
V 200mm x 250mm x 75mm thick Concrete downstand for storm water channel 46 LM
M 12mm to walls. 25 SM
TWO COATS BLACK BITUMASTIC paint on:
N Rendered walls to plinth walls 25 SM
COLLECTION
Total brought forward from Page 5/1/1
Total brought forward from Page 5/1/2
A Ring beams 3 CM
B Beams 4 CM
C Columns 2 CM
STEEL REINFORCEMENT as described including cutting to length, bending, hoisting and
fixing and including all necessary tying wire and spacing blocks
BLOCK WORK
Solid Concrete blockwork jointed and pointed in cement sand (1:3) mortar with and
including hoop iron wall ties every alternative course : in
D Vent bricks 6 SM
DAMP PROOF COURSE OF BITUMEN FELT TO B.S 743 Type A with 150mm laps
including cement and sand (1:3) levelling bed
E 200mm Wide 61 LM
150mm Wide 25 LM
A Filler blocks 15 LM
COLLECTION
5/4/2
A Door D04 overall Size 900 x 2400mm high with and including 5mm thick clear sheet glass and 2 NO
fixed glazing panel 300mm high above transom: Complete with Aluminium kick plates (814 x
220mm)
B Door D03 overall Size 900 x 2400mm high with and including framing complete with 4 NO
APPROVED COFFEE TRAY WIRE and mosquito proof guaze 300mm high above transom.
G General surfaces 19 SM
H Surfaces 100 - 300mm girth 58 LM
I Surfaces not exceeding 100mm girth 134 LM
J Prime back of surfaces of frames before fixing 58 LM
Supply and fix the following ironmongery : locks and furniture where applicable are to be
equal to those manufactured by "UNION" and approved by the Architect
K 100mm long stainless steel 2Ball Bearing Butt hinges complete with screws 15.0 PRS
L Stainless steel Lever handles with and including 1 pair of CB escutcheons 10 PRS
5/5/1
COLLECTION
Total Carried Forward From Page 5/5/1
Total Carried Forward From Page 5/5/2
F Steel windows 31 SM
G Burglar proof 31 SM
CURTAIN RODS
H 25mm diameter spray painted galvanised iron curtain rail on and including 100mm diameter x 12 LM
25mm thick timber end brackets thrice plugged into wall
K Wall surfaces 14 SM
L Extra over tiles for boarder tiles. 8 LM
M Extra over for rounded top edge. 8 LM
N Extra over for PVC corner strip 14 LM
A Ceiling 81 SM
B 150 x 150mm Coved Cornice 142 LM
C Extra over ceiling for trap door 1 NO
PREPARE AND APPLY THREE COATS first matt emulsion paint
D Metal Lath Plaster Ceiling 81 SM
E Surfaces not exceeding 100mm girth 142 LM
ELEMENT NO.9
FLOOR FINISHES
D Floors 2 SM
SPLASH APRON
E 100mm thick concrete class 20/20mm aggregate splash reinforced with and including fabric 28 SM
mesh reinforcement ref A98 as before described; including Gauge 1000 DPM and 200mm
Thick Hardcore Blinded with Stone dust and all necessary formwork.
F 200mm thick walling to sides of splash Apron with and including 450 x 150mm foundation 46 LM
concrete; finished with steel float to exposed surfaces; necessary excavation and disposal of
surplus soil.
5/9/1
WARDROBES
WARDROBES AND CLOSETS COMPRISING OF: 25mm THICK HARD WOOD
SHUTTERS; 25mm MDF SHELVES AND PARTITONS; 25mm diameter chrome plated
hanger rail: iron mongery and accessories: painting and decorations; in: -
A Wardrobe overall size 600mm deep x 2400mm high; to Architect's detailed drawing 5 LM
VANITY TOP
Worktop comprising of: 20mm thick polished Terrazo worktop with 100mm high terrazo
fascia on and including 100mm thick brick wall support 1050mm high; plaster and paint to
sides of wall; to Architect's detailed drawings
B Low level Kitchen unit overall size 600mm wide x 900mm high 6 LM
HIGH LEVEL CABINET COMPRISING OF: 32 x 6mm thick mahogany veneered
blockboard louvred shutters with concealed hinges, bases and partitions; 6mm thick plywood
backing; 50 x 25mm softwood timber bearers, insect gauge in 10 x 6mm softwood decorative
beading and 100 x 25mm softwood fascia; all iron mongery and accessories: all painting and
decorations; to Architects detailed drawing; in
C High level Kitchen unit overall size 300mm wide x 600mm high 6 NO
TOTAL TO SUMMARY
5/10/1
All underground reticulation and distribution cables are to be supplied and installed c/w all
necessary fixing / clipping / supporting / glanding and termination accessories as per general
specification and type approved by the supervising Electrical Engineer
The rate for the underground cables shall cover excavation, sand-bedding, backfilling,
trenching, enclosing in PVC ducts, where necessary, and all associated builders' works.
Actual measurements shall be based on the site conditions.
All indoor cables are to recessed within the cable ducts, ceiling voids, wall fabric enclosed in
suitably sized PVC conduits neatly installed and to further Instructions from the Electrical
Engineer and/or Drawings.
All lighting fittings shall be as per Specifications and Drawings with control gear
compartible with 240V/50Hz. All lighting fittings are to be approved by the Electrical
Engineer prior to installation.
All Fire Detection and Alarm System elements are to be to fully addressable to Gent Vigilon
System Architecture, or otherwise approved.
All wiring accessories shall be as per original Legrand Specifications and Drawings (or
otherwise specificied and approved) complete with all attachments and accessories. All
samples to be approved prior to installation by the Engineer.
The entire electrical installation shall be tested for compliance in accordance to the 16th
Edition of the IEE Wiring Regulations and witnessed / approved by the Engineer
TO COLLECTION
5/11/1
C 16mm sq.3-Core SC XLPE-SWA-PVC Copper cables for Power Supply connection from the 60 LM
source to the consumer unit.
LIGHTING FITTINGS:
D LED surface downlights 20W as Philips or equal 16 NO
E LED Outdoor wall mounted security lights, c/w louvred and all accessories as Radiant 6 NO
Lighting or equal approved
WIRING ACCESSORIES:
F 10A/250V SP 1-Gang 1-Way white flush moulded plate switch c/w flush mounting box, and 8 NO
accessories to Legrand Synergy Modern manufacture Cat. 7310 00.
I Outdoor Hard-Wired Post Eye Light Control Electric Resistor Photocell Light Sensor, as to 1 NO
LEGRAND or equivalent.
WIRING and CONDUITING:
Lighting points:
J All wiring of lighting points are to be connected complete and ready from 10A SP miniature 22 NO
circuit breakers, using 3x2.5mm sq. PVC-Insulated single core copper cables drawn in a 25mm
PVC concealed conduits, through switches, and as per drawings.
TO COLLECTION
5/11/2
LIGHTNING PROTECTION
All items are to be supplied and installed complete with all the required mounting, fixing,
clipping, testing including connecting accessories. All to be tested and commissioned to the
satisfaction of the Electrical Engineer.
Supply, install, connect and set to work the following, all as described in the specifications
and drawings
B 25mm x 3mm copper tape as to FURSE manufacture, or approved equivalent. 40 LM
C 25mm x 3mm copper square test clamp, as to FURSE Cat.No. CT 105, or approved equivalent. 2 NO
D 2000mm x 15mm air rod, as to FURSE Cat. No. RA 240 c/w multiple point, as to FURSE Cat. 1 NO
No. RA 600, air terminal base, as to FURSE Cat. No. SD 105, and ridge saddle, as to FURSE
Cat. No. SD 115, or approved equivalent.
TO COLLECTION
COLLECTION
Total Carried Forward From Page 5/11/1
Total Carried Forward From Page 5/11/2
Total Carried Forward From Page 5/11/3
TO SUMMARY
5/11/3
B 25mm PPR pipe PN 25 complete with tees, elbows, reducers and all associted fittings. 20 LM
E 700mm x 700mm low profile Vitreous China Shower Tray complete with waste and trap and 2 NO
all other accessories to a working condition
F 450 x 350mm wash hand basin complete with built-in angle valve , bottle trap , 1/2" bib tap a, 2 NO
pop-up waste and flexible supply hose.
G Overhead shower head complete with mixer and all accessories 2 NO
H 1/2" Bib tap complete with all acessories 2 NO
I Wall mounted soap dish holder complete with all fixing accessories 2 NO
J Stainless steel Single Towel Rail 600mm Long 2 NO
BILL NO.5
SUMMARY
1 SUBSTRUCTURES 5/1/2
3 WALLING 5/3/1
5 DOORS 5/5/2
6 WINDOWS 5/6/1
5/S
767670138.xlsx
BILL NO.6
2-UNIT STAFF KITCHEN
P Column bases 1 CM
Q Stub Columns 1 CM
R Ground Beam 1 CM
S 125mm thick ground floor slab 20 SM
T 200mm x 250mm x 75mm thick Concrete downstand for storm water channel 23 LM
COLLECTION
Total brought forward from Page 6/1/1
Total brought forward from Page 6/1/2
A Ring beams 2 CM
B Columns 1 CM
STEEL REINFORCEMENT as described including cutting to length, bending,
hoisting and fixing and including all necessary tying wire and spacing blocks
BLOCK WORK
Solid Concrete blockwork jointed and pointed in cement sand (1:3) mortar with and
including hoop iron wall ties every alternative course : in
F Plastered surfaces 71 SM
G Plastered surfaces of reveals 75 - 150mm girth : internal 11 LM
ELEMENT NO.7
FLOOR FINISHES
A Floors 15 SM
CEMENT AND SAND (1:3)
B 150 x 25mm Skirting : square top and coved junction at bottom 24 LM
SPLASH APRON
C 100mm thick concrete class 20/20mm aggregate splash reinforced with and including 12 SM
fabric mesh reinforcement ref A98 as before described; including Gauge 1000 DPM
and 200mm Thick Hardcore Blinded with Stone dust and all necessary formwork.
D 200mm thick walling to sides of splash Apron with and including 450 x 150mm 23 LM
foundation concrete; finished with steel float to exposed surfaces; necessary
excavation and disposal of surplus soil.
6/7/1
CONCRETE WORKTOP
Worktop comprising of: 20mm thick polished Terrazo worktop with 100mm high
terrazo fascia on and including 100mm thick brick wall support 1050mm high;
plaster and paint to sides of wall; to Architect's detailed drawings
TOTAL TO SUMMARY
6/8/1
Supply, install, connect and set to work the following, all as described in the
specifications and drawings
A Concrete Inspection chamber : size 300mm x 300mm internal dimension : as to 1 NO
FURSE Cat. No. PT005, or approved equivalent.complete with heavy duty manhole
cover, charcoal and salt solution.
B Copper earth rod 16mm diameter, 1200mm long; complete with tower earth clamps, 1 NO
nuts and bolts for fastening to copper down conductors.
C 25mm x 3mm PVC-Insulated copper down conductor complete with Gutter clamps, 10 LM
roof conductor holders/ clips to FURSE Cat.No. TC 115, or approved equivalent.Fixed
through a conduit and embedded into the wall.
D 25mm X 3mm Copper test clamp with flush inspection tape (test Link), as FURSE 1 NO
Cat. No. CT 105, or equal approved.
E 2000mm x 15mm air rod, Type A ;as to FURSE Cat. No. RA 240 c/w multiple point, 1 NO
as to FURSE Cat. No. RA 600, or approved equivalent.
F Air terminals base as to FURSE Cat. No. SD 105, or approved equivalent complete 1 NO
with tape adapter and all accessories.
G Equipotential bonding to indoor and outdoor metallic parts consisting of bi-metallic 1 LM
connectors and clips made of 8mm copper round conductors.
H Surge Protective Devices (SPD’s) SPD’s shall provide protection against lightning and ITEM
transient over voltages on phase/neutral, phase/earth and neutral/earth modes.
I Allow for testing and commissioning of the installation 1 ITEM
B Lighting points wired by 3 x 1.5 mm2 SC PVC copper cables in 25 mm heavy guage 6 NO
PVC surface conduit with drops to switch positions complete with MK steel boxes
complete with all accessories.
C Power points wired by 3 x 2.5 mm2 SC PVC copper cables in 25 mm heavy guage 2 NO
PVC surface conduit with drops to switch positions complete with MK steel boxes
complete with all accessories.
COLLECTION
Total Carried Forward From Page 6/9/1
Total Carried Forward From Page 6/9/2
6/10/2
E Single bowl single drain Kitchen Stainless Steel Sinks c/w with Sink Mixer Mounted 2 NO
on Wall with regular Spout and all necessary accessories
BILL NO.6
SUMMARY
1 SUBSTRUCTURES 6/1/2
3 WALLING 6/3/1
5 DOORS 6/5/2
6/S
767670138.xlsx
BILL NO.7
2-STANCE LINED VIP LATRINE FOR
ADMINISTRATION BLOCK
C Excavate top vegetable soil average 150mm deep and cart to spoil 44 SM
D Mass excavation to reduce levels commencing from stripped level; deposit in 22 CM
temporary spoil heaps on site.
E Excavate for pits commencing at reduced level but not exceeding 1.5 meters deep. 9 CM
P Pit bases 1 CM
Q Beams 1 CM
R Ground beams 1 CM
S 100mm Thick suspended solid slab 4 SM
T 100mm Thick ground slab 4 SM
WALLING
Solid concrete blockwork jointed and pointed in cement sand (1:3) mortar : with
and including hoop iron wall ties every alternative course : in
TO COLLECTION
COLLECTION
Total Carried Forward From Page 7/1/1
Total Carried Forward From Page 7/1/2
Total Carried Forward From Page 7/1/3
A Ring beams 1 CM
STEEL REINFORCEMENT as described including cutting to length, bending,
hoisting and fixing and including all necessary tying wire and spacing blocks
D Vent bricks 3 SM
DAMP PROOF COURSE OF BITUMEN FELT TO B.S 743 Type A with
150mm laps including cement and sand (1:3) levelling bed
E 150mm wide 19 LM
7/4/1
H Plastered surfaces 23 SM
I Plastered surfaces of reveals 75 - 150mm girth : internal 12 LM
ELEMENT NO.7
FLOOR FINISHES
CEMENT AND SAND (1:3) SCREED, including 25 x 3mm pvc dividing strips
at 1200mm centres : in
A Floors 8 SM
B 150 x 25mm Skirting : square top and coved junction at bottom 18 LM
SPLASH APRON
C 100mm thick concrete class 20/20mm aggregate splash reinforced with and 9 SM
including fabric mesh reinforcement ref A98 as before described; including Gauge
1000 DPM and 200mm Thick Hardcore Blinded with Stone dust and all necessary
formwork.
D 200mm thick walling to sides of splash Apron with and including 450 x 150mm 20 LM
foundation concrete; finished with steel float to exposed surfaces; necessary
excavation and disposal of surplus soil.
7/7/1
D Soak Pit Size approx. 2500mm on top tapering to 1500mm and depth of 1500mm 1 NO
complete with hardcore and all accessories.
BILL NO.7
SUMMARY
1 SUBSTRUCTURES 7/1/3
3 WALLING 7/3/1
5 DOORS 7/5/1
7/S
BILL NO.8
2-STANCE LINED VIP LATRINE FOR
TEACHERS'
C Excavate top vegetable soil average 150mm deep and cart to spoil 44 SM
D Mass excavation to reduce levels commencing from stripped level; 22 CM
deposit in temporary spoil heaps on site.
E Excavate for pits commencing at reduced level but not exceeding 1.5 9 CM
meters deep.
F Ditto but 1.5 to 3.0m deep 9 CM
G Excavate for trenches commencing at reduced level but not exceeding 21 CM
1.5 meters deep.
H Extra over excavations for excavating in rock. 5 SM
I Return fill and ram selected excavated material around foundations. 16 SM
J Load and cart away surplus excavated material from site. 9 SM
K 150mm thick bed of hand packed stone base, well rolled and 12 SM
compacted.
L 50mm Thick sand blinding over surfaces of hardcore 12 SM
M Insecticide treatment to surfaces of hardcore, top of foundation walling, 52 SM
sides and bottom of excavation.
CONCRETE WORK
PLAIN CONCRETE CLASS 10 MIX 1:4:8 (20MM AGGREGATE)
N 50mm Thick blinding layer under pit base 4 SM
MASS CONCRETE CLASS 20; 20mm AGGREGATE : in
O Strip foundations 3 CM
VIBRATED REINFORCED CONCRETE CLASS 20; 20mm
AGGREGATE : in
P Pit bases 1 CM
Q Beams 1 CM
R Ground beams 1 CM
S 100mm Thick suspended solid slab 4 SM
T 100mm Thick ground slab 12 SM
WALLING
Solid concrete blockwork jointed and pointed in cement sand (1:3)
mortar : with and including hoop iron wall ties every alternative
course : in
K 200mm Thick walls 51 SM
SUNDRIES
L 20 SWG Hoop Iron wall tie 25mm wide x 450mm long cast 75mm into 19 NO
concrete and built into joint of block walling
TO COLLECTION
COLLECTION
Total Carried Forward From Page 8/1/1
Total Carried Forward From Page 8/1/2
Total Carried Forward From Page 8/1/3
8/4/1
H Plastered surfaces 23 SM
I Plastered surfaces of reveals 75 - 150mm girth : internal 12 LM
ELEMENT NO.7
FLOOR FINISHES
D 200mm thick walling to sides of splash Apron with and including 450 x 25 LM
150mm foundation concrete; finished with steel float to exposed
surfaces; necessary excavation and disposal of surplus soil.
8/7/1
D Soak Pit Size approx. 2500mm on top tapering to 1500mm and depth of 1 NO
1500mm complete with hardcore and all accessories.
BILL NO.8
SUMMARY
1 SUBSTRUCTURES 8/1/3
3 WALLING 8/3/1
5 DOORS 8/5/1
8/S
BILL NO.9
5-STANCE LINED VIP LATRINE FOR BOYS
767670138.xlsx
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE (USHS) (USHS)
BILL NO.9
5-STANCE LINED VIP LATRINE - BOYS
ELEMENT NO. 1
SUBSTRUCTURES
The work in this element includes all works up to and including the ground floor slab
A Allow for maintaining and upholding sides of excavation: clear off all fallen material, rubbish 1 ITEM
B Allow for keeping the whole of the excavation free from general water 1 ITEM
C Excavate top vegetable soil average 150mm deep and cart to spoil 60 SM
Mass excavation to reduce levels commencing from stripped level; deposit in temporary spoil
D heaps on site. 24 CM
E Excavate for pits commencing at reduced level but not exceeding 1.5 meters deep. 45 CM
G Excavate for trenches commencing at reduced level but not exceeding 1.5 meters deep. 4 CM
K 150mm thick bed of hand packed stone base, well rolled and compacted. 16 SM
Insecticide treatment to surfaces of hardcore, top of foundation walling, sides and bottom of
M excavation. 65 SM
CONCRETE WORK
PLAIN CONCRETE CLASS 10 MIX 1:4:8 (20MM AGGREGATE)
Q Beams 2 CM
R Ground beams 2 CM
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE (USHS) (USHS)
STEEL REINFORCEMENT as described including cutting to length, bending, hoisting
and fixing and including all necessary tying wire and spacing blocks
MILD STEEL ROUND BARS TO BS 4449
A 8mm Diameter bars 51 KG
FORMWORK TO
D Vertical Sides of pit bases 4 SM
WALLING
Solid concrete blockwork jointed and pointed in cement sand (1:3) mortar : with and
including hoop iron wall ties every alternative course : in
SUNDRIES
20 SWG Hoop Iron wall tie 25mm wide x 450mm long cast 75mm into concrete and built
L into joint of block walling 42 NO
DAMP PROOF COURSE OF BITUMEN FELT TO B.S 743 Type A with 150mm laps
including cement and sand (1:3) levelling bed
M 200mm Wide under the walls 23 LM
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE (USHS) (USHS)
TWO COATS EXTERNAL CEMENT RENDER (1:4) finished with wood float to plinth
walls
A 12mm to walls. 121 SM
TWO COATS BLACK BITUMASTIC paint on:
B Rendered walls to plinth walls 121 SM
TO COLLECTION
COLLECTION
Total Carried Forward From Page 8/1/1
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE (USHS) (USHS)
BILL NO.9
ELEMENT NO.2
R.C. FRAME
CONCRETE WORK
FORMWORK TO:
D Sides and Soffittes of horizontal suspended solid slabs 11 SM
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE (USHS) (USHS)
BILL NO.9
ELEMENT NO.3
WALLING
PRECAST CONCRETE CLASS 20; finished fair on all exposed surfaces including
bedding and jointing in cement sand (1:3) mortar
A 200 x 60mm Weathered and throated coping 22 LM
BLOCK WORK
Solid Concrete blockwork jointed and pointed in cement sand (1:3) mortar with and
including hoop iron wall ties every alternative course : in
DAMP PROOF COURSE OF BITUMEN FELT TO B.S 743 Type A with 150mm laps
including cement and sand (1:3) levelling bed
E 150mm wide 23 LM
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE (USHS) (USHS)
BILL NO.9
ELEMENT NO.4
ROOF COVERING
26 Gauge pre-coated corrugated galvanised iron roofing sheets : lapped 1 1/2 corrugations
on sides : fixed to timber purlins (m/s) with galvanised iron drive screws with washers.
D Sheet laid sloping not exceeding 45 degrees from horizontal. 24 SM
PREPARE AND APPLY THREE Coats gloss oil paint in accordance with manufacture's
instructions; on wood : to
L Surfaces 200 - 300mm girth 60 LM
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE (USHS) (USHS)
BILL NO.9
ELEMENT NO. 5
DOORS
STEEL DOORS
PREPARE SURFACE AND APPLY ETCHING PRIMER; apply one coat primer, one
undercoat and two Gloss finishing coats; on metal work : to
C General door surfaces 23 SM
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE (USHS) (USHS)
BILL NO.9
ELEMENT NO.6
WALL FINISHES
EXTERNAL FINISHES
INTERNAL LIME PLASTER First coat of cement lime and sand (1:2:9) second coat of
cement, lime putty and sand (1:1.6) Steel trowelled smooth
H Plastered surfaces 52 SM
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE (USHS) (USHS)
BILL NO.9
ELEMENT NO.7
FLOOR FINISHES
CEMENT AND SAND (1:3) SCREED, including 25 x 3mm pvc dividing strips at 1200mm
centres : in
A Floors 8 SM
SPLASH APRON
100mm thick concrete class 20/20mm aggregate splash reinforced with and including fabric
mesh reinforcement ref A98 as before described; including Gauge 1000 DPM and 200mm
C Thick Hardcore Blinded with Stone dust and all necessary formwork. 11 SM
200mm thick walling to sides of splash Apron with and including 450 x 150mm foundation
concrete; finished with steel float to exposed surfaces; necessary excavation and disposal of
D surplus soil. 25 LM
AMOUNT
ITEM DESCRIPTION QTY UNIT RATE (USHS) (USHS)
BILL NO.9
ELEMENT NO.8
MECHANICAL INSTALLATION
110mm PVC heavy gauge pipework buried in the ground to a fall of 1:60 complete with
C excavations, bedding, backfilling and all accessories. 10 LM
Soak Pit Size approx. 2500mm on top tapering to 1500mm and depth of 1500mm complete
D with hardcore and all accessories. 1 NO
Construct an inspection chamber 450 x 500mm including: 50mm thick pre-cast concrete
E cover with 2NO. Mild steel Lifting rings 8mm diameter bar 1 NO
100mm diameter uPVC soil and vent pipe 3500mm high with and including wire balloon
F grating. 5 NO
BILL NO. 9
SUMMARY
1 SUBSTRUCTURES 9/1/3
3 WALLING 9/3/1
5 DOORS 9/5/1
9/S
767670138.xlsx
BILL NO.10
5-STANCE LINED VIP LATRINE FOR GIRLS
767670138.xlsx
RATE AMOUNT
ITEM DESCRIPTION QTY UNIT (USHS) (USHS)
BILL NO.10
ELEMENT NO. 1
SUBSTRUCTURES
The work in this element includes all works up to and including the ground floor slab
A Allow for maintaining and upholding sides of excavation: clear off all fallen material, rubbish 1 ITEM
B Allow for keeping the whole of the excavation free from general water 1 ITEM
C Excavate top vegetable soil average 150mm deep and cart to spoil 60 SM
Mass excavation to reduce levels commencing from stripped level; deposit in temporary spoil
D heaps on site. 24 CM
E Excavate for pits commencing at reduced level but not exceeding 1.5 meters deep. 45 CM
K 150mm thick bed of hand packed stone base, well rolled and compacted. 16 SM
Insecticide treatment to surfaces of hardcore, top of foundation walling, sides and bottom of
M excavation. 65 SM
CONCRETE WORK
PLAIN CONCRETE CLASS 10 MIX 1:4:8 (20MM AGGREGATE)
N 50mm Thick blinding layer under pit base 22 SM
P Pit bases 2 CM
Q Beams 2 CM
R Ground beams 2 CM
RATE AMOUNT
ITEM DESCRIPTION QTY UNIT (USHS) (USHS)
STEEL REINFORCEMENT as described including cutting to length, bending, hoisting and
fixing and including all necessary tying wire and spacing blocks
MILD STEEL ROUND BARS TO BS 4449
FORMWORK TO
WALLING
Solid concrete blockwork jointed and pointed in cement sand (1:3) mortar : with and including
hoop iron wall ties every alternative course : in
K 200mm Thick walls 101 SM
SUNDRIES
20 SWG Hoop Iron wall tie 25mm wide x 450mm long cast 75mm into concrete and built into
L joint of block walling 42 NO
DAMP PROOF COURSE OF BITUMEN FELT TO B.S 743 Type A with 150mm laps
including cement and sand (1:3) levelling bed
M 200mm Wide under the walls 23 LM
RATE AMOUNT
ITEM DESCRIPTION QTY UNIT (USHS) (USHS)
TWO COATS EXTERNAL CEMENT RENDER (1:4) finished with wood float to plinth walls
A 12mm to walls. 121 SM
TO COLLECTION
COLLECTION
10/1/3
767670138.xlsx
RATE AMOUNT
ITEM DESCRIPTION QTY UNIT (USHS) (USHS)
BILL NO.10
ELEMENT NO.2
R.C. FRAME
CONCRETE WORK
A Ring beams 2 CM
FORMWORK TO:
D Sides and Soffittes of horizontal suspended solid slabs 11 SM
RATE AMOUNT
ITEM DESCRIPTION QTY UNIT (USHS) (USHS)
BILL NO.10
ELEMENT NO.3
WALLING
PRECAST CONCRETE CLASS 20; finished fair on all exposed surfaces including bedding
and jointing in cement sand (1:3) mortar
BLOCK WORK
Solid Concrete blockwork jointed and pointed in cement sand (1:3) mortar with and including
hoop iron wall ties every alternative course : in
150mm HARD BURNT CLAY VENT BRICKS to BS 3921 (3.5N/mm2 compressive strength)
bedded, jointed and pointed in cement and sand (1:4) mortar and painted in coloured cement
D Vent bricks 5 SM
DAMP PROOF COURSE OF BITUMEN FELT TO B.S 743 Type A with 150mm laps
including cement and sand (1:3) levelling bed
E 150mm wide 23 LM
10/3/1
767670138.xlsx
RATE AMOUNT
ITEM DESCRIPTION QTY UNIT (USHS) (USHS)
BILL NO.10
ELEMENT NO.4
ROOF COVERING
26 Gauge pre-coated corrugated galvanised iron roofing sheets : lapped 1 1/2 corrugations on
sides : fixed to timber purlins (m/s) with galvanised iron drive screws with washers.
PREPARE AND APPLY THREE Coats gloss oil paint in accordance with manufacture's
instructions; on wood : to
10/4/1
767670138.xlsx
RATE AMOUNT
ITEM DESCRIPTION QTY UNIT (USHS) (USHS)
BILL NO.10
ELEMENT NO. 5
DOORS
STEEL DOORS
PREPARE SURFACE AND APPLY ETCHING PRIMER; apply one coat primer, one
undercoat and two Gloss finishing coats; on metal work : to
10/5/1
767670138.xlsx
RATE AMOUNT
ITEM DESCRIPTION QTY UNIT (USHS) (USHS)
BILL NO.10
ELEMENT NO.6
WALL FINISHES
EXTERNAL FINISHES
H Plastered surfaces 52 SM
10/6/1
767670138.xlsx
RATE AMOUNT
ITEM DESCRIPTION QTY UNIT (USHS) (USHS)
BILL NO.10
ELEMENT NO.7
FLOOR FINISHES
CEMENT AND SAND (1:3) SCREED, including 25 x 3mm pvc dividing strips at 1200mm
centres : in
A Floors 8 SM
SPLASH APRON
100mm thick concrete class 20/20mm aggregate splash reinforced with and including fabric
mesh reinforcement ref A98 as before described; including Gauge 1000 DPM and 200mm Thick
C Hardcore Blinded with Stone dust and all necessary formwork. 11 SM
200mm thick walling to sides of splash Apron with and including 450 x 150mm foundation
concrete; finished with steel float to exposed surfaces; necessary excavation and disposal of
D surplus soil. 25 LM
RATE AMOUNT
ITEM DESCRIPTION QTY UNIT (USHS) (USHS)
BILL NO.10
ELEMENT NO.8
MECHANICAL INSTALLATION
110mm PVC heavy gauge pipework buried in the ground to a fall of 1:60 complete with
C excavations, bedding, backfilling and all accessories. 10 LM
Soak Pit Size approx. 2500mm on top tapering to 1500mm and depth of 1500mm complete with
D hardcore and all accessories. 1 NO
Construct an inspection chamber 450 x 500mm including: 50mm thick pre-cast concrete cover
E with 2NO. Mild steel Lifting rings 8mm diameter bar 1 NO
F 100mm diameter uPVC soil and vent pipe 3500mm high with and including wire balloon grating. 5 NO
10/8/1
767670138.xlsx
BILL NO. 10
SUMMARY
1 SUBSTRUCTURES 10/1/3
3 WALLING 10/3/1
5 DOORS 10/5/1
10/S
767670138.xlsx
BILL NO.11
EXTERNAL WORKS
767670138.xlsx
TREE STAMPS
D Grub up roots and chop-up tree stamps and remove all arising from 5 NO
site : stamps 1500mm girth.
MASS EXCAVATION
E Mass excavation to reduce levels commencing from stripped level; 2,400 CM
deposit in temporary spoil heaps on site.
F Load and cart away surplus excavated material from site. 1,200 CM
FILL TO MAKE UP LEVELS
G Load from spoil heaps, spread and level selected excavated material 1,200 CM
where directed on site including compacting in layers not exceeding
150mm thick using 15 ton vibrating roller to 95% MDD ASHTO to
Engineer's approval.
TO SUMMARY
11/1/1
TO SUMMARY
11/2/1
TO SUMMARY
11/3/1
BILL NO.11
EXTERNAL WORKS
SUMMARY
3 LANDSCAPING 11/3/1
11/S
BILL NO.12
5000L WATER TANK
767670138.xlsx
TO SUMMARY
12/1/1
Tank
D 5000 Litre HDPE water tank 1 NO
E 300mm x 12mm Diameter overflow pipe 1 NO
F 1700mm x 12mm Diameter pipe : Wash out complete with stop valves. 1 NO
TO SUMMARY
12/2/1
BILL NO.12
SUMMARY
BILL NO.13
ICT - LIBRARY BLOCK
A Allow for maintaining and upholding sides of excavation: clear off all fallen material, 1 ITEM
rubbish
B Allow for keeping the whole of the excavation free from general water 1 ITEM
C Excavate top vegetable soil average 150mm deep and cart to spoil 0 SM
D Excavate to reduce levels not exceeding 1.50 metres deep and remove from site. 0 CM
Q Column bases 7 CM
R Stub Columns 2 CM
S Ground Beam 8 CM
U 125mm thick ground floor slab 314 SM
V 200mm x 250mm x 75mm thick Concrete downstand for storm water channel 100 LM
COLLECTION
Total brought forward from Page 13/1/1
Total brought forward from Page 13/1/2
A Ring beams 6 CM
B Beams 7 CM
C Columns 3 CM
STEEL REINFORCEMENT as described including cutting to length, bending, hoisting
and fixing and including all necessary tying wire and spacing blocks
D Vent bricks 10 SM
DAMP PROOF COURSE OF BITUMEN FELT TO B.S 743 Type A with 150mm laps
including cement and sand (1:3) levelling bed
E 200mm Wide 125 LM
COLLECTION
13/4/2
A Door D02 overall Size 900 x 2400mm high with and including 4mm thick clear sheet glass 4 NO
and fixed glazing panel 300mm high above transom
B Door D03 overall Size 1200 x 2400mm high with and including timber louvered panel 2 NO
300mm high above transom
K 100mm long stainless steel 2Ball Bearing Butt hinges complete with screws 12.0 PRS
L Stainless steel Lever handles with and including 1 pair of CB escutcheons 6 PRS
COLLECTION
Total Carried Forward From Page 13/5/1
Total Carried Forward From Page 13/5/2
A Ceiling 97 SM
B 150 x 150mm Coved Cornice 109 LM
C Extra over ceiling for trap door 2 NO
PREPARE AND APPLY THREE COATS first matt emulsion paint
A Floors 278 SM
CEMENT AND SAND (1:3)
B 150 x 25mm Skirting : square top and coved junction at bottom 255 LM
SPLASH APRON
C 100mm thick concrete class 20/20mm aggregate splash reinforced with and including fabric 56 SM
mesh reinforcement ref A98 as before described; including Gauge 1000 DPM and 200mm
Thick Hardcore Blinded with Stone dust and all necessary formwork.
D 200mm thick walling to sides of splash Apron with and including 450 x 150mm foundation 100 LM
concrete; finished with steel float to exposed surfaces; necessary excavation and disposal of
surplus soil.
Seat/ Backrest: 25 mm thick well seasoned Mahogany hard wood sanded and polished:
finished with three coats of clear varnish, Dimensions 440mm x 450mm Seat: 180mm x
450mm Backrest.
D Chairs 112 NO
BOOK SHELVES
BOOK SHELVES COMPRISING OF: 25x25x2mm SHS steel frame ; with 25x25x2mm
steel bracing; 25mm thick hardwood timber board provided on each shelve at an interval
of 317mm; 25mm thick hardwood timber on both sides of the shelve; a 5mm thick back
cover plywood board screwed on the steel frame; complete with approved ribber shoes at
the bottom of the steel frame; including all necessary accessories, painting and
decorations per Architect's detailed drawing ICT-LIB-11,12,13&14
E Book shelve unit overall size 800mm long x 600mm Wide x 2100mm high; to Architect's 10 NO
detailed drawing
F Book shelve unit overall size 2000mm long x 600mm Wide x 2100mm high; to Architect's 2 NO
detailed drawing
G Book shelve unit overall size 2270mm long x 600mm Wide x 2100mm high; to Architect's 1 NO
detailed drawing
H Book shelve unit overall size 1280mm long x 600mm Wide x 2100mm high; to Architect's 2 NO
detailed drawing
I Book shelve unit overall size 1000mm long x 600mm Wide x 2100mm high; to Architect's 1 NO
detailed drawing
J Book shelve unit overall size 4260mm long x 600mm Wide x 2100mm high; to Architect's 1 NO
detailed drawing
K Book shelve unit overall size 1500mm long x 600mm Wide x 2100mm high; to Architect's 1 NO
detailed drawing
L Book shelve unit overall size 560mm long x 600mm Wide x 2100mm high; to Architect's 1 NO
detailed drawing
C Shelving overall 1185mm Long x 300mm Wide x 1100mm high; to Architect's detailed 2 NO
drawing
D Aloow a Provisional Sum Uganda Shillings 1,000,000 (One Million Uganda Shillings) 1 SUM
Furniture Engraving
COLLECTION
Total Carried Forward From Page 13/10/1
Total Carried Forward From Page 13/10/2
Total Carried Forward From Page 13/10/3
All underground reticulation and distribution cables are to be supplied and installed c/w
all necessary fixing / clipping / supporting / glanding and termination accessories as per
general specification and type approved by the supervising Electrical Engineer
The rate for the underground cables shall cover excavation, sand-bedding, backfilling,
trenching, enclosing in PVC ducts, where necessary, and all associated builders' works.
Actual measurements shall be based on the site conditions.
All indoor cables are to recessed within the cable ducts, ceiling voids, wall fabric enclosed
in suitably sized PVC conduits neatly installed and to further Instructions from the
Electrical Engineer and/or Drawings.
All lighting fittings shall be as per Specifications and Drawings with control gear
compartible with 240V/50Hz. All lighting fittings are to be approved by the Electrical
Engineer prior to installation.
All Fire Detection and Alarm System elements are to be to fully addressable to Gent
Vigilon System Architecture, or otherwise approved.
All wiring accessories shall be as per original Legrand Specifications and Drawings (or
otherwise specificied and approved) complete with all attachments and accessories. All
samples to be approved prior to installation by the Engineer.
The entire electrical installation shall be tested for compliance in accordance to the 16th
Edition of the IEE Wiring Regulations and witnessed / approved by the Engineer
TO COLLECTION
13/11/1
C 16mm sq.3-Core SC XLPE-SWA-PVC Copper cables for Power Supply connection from 40 LM
the source to the consumer unit.
LIGHTING FITTINGS:
LED T5 1x28W, 1200mm flourescent batten light fitting with an electronic control gear as 32 NO
Thorn or equal approved
D LED surface downlights 20W as Philips or equal 2 NO
E LED Outdoor wall mounted security lights, c/w louvred and all accessories as Radiant 8 NO
Lighting or equal approved
WIRING ACCESSORIES:
F 10A/250V SP 1-Gang 1-Way white flush moulded plate switch c/w flush mounting box, and 4 NO
accessories to Legrand Synergy Modern manufacture Cat. 7310 00.
I Outdoor Hard-Wired Post Eye Light Control Electric Resistor Photocell Light Sensor, as to 1 NO
LEGRAND or equivalent.
WIRING and CONDUITING:
Lighting points:
J All wiring of lighting points are to be connected complete and ready from 10A SP 42 NO
miniature circuit breakers, using 3x2.5mm sq. PVC-Insulated single core copper cables
drawn in a 25mm PVC concealed conduits, through switches, and as per drawings.
TO COLLECTION
13/11/2
DATA POINTS
B Conduiting from the ICT rack to each data outlet using 25mm diameter PVC conduit 15 NO
installed as per the Drawings c/w with MK box
ICT INSTALLATIONS
C Allow a PC sum of Ushs. 30,000,000 for ICT installations to include bur not limited to, Data 1 SUM
face plates, rack, CAT6 cables, switch, patch panels & patch codes for the computer lab
LIGHTNING PROTECTION
All items are to be supplied and installed complete with all the required mounting, fixing,
clipping, testing including connecting accessories. All to be tested and commissioned to
the satisfaction of the Electrical Engineer.
Supply, install, connect and set to work the following, all as described in the specifications
and drawings
D 25mm x 3mm copper tape as to FURSE manufacture, or approved equivalent. 40 LM
E 25mm x 3mm copper square test clamp, as to FURSE Cat.No. CT 105, or approved 2 NO
equivalent.
F 2000mm x 15mm air rod, as to FURSE Cat. No. RA 240 c/w multiple point, as to FURSE 3 NO
Cat. No. RA 600, air terminal base, as to FURSE Cat. No. SD 105, and ridge saddle, as to
FURSE Cat. No. SD 115, or approved equivalent.
COLLECTION
Total Carried Forward From Page 13/11/1
TO SUMMARY
13/11/3
BILL NO.13
SUMMARY
1 SUBSTRUCTURES 13/1/2
3 WALLING 13/3/1
6 DOORS 13/5/2
7 WINDOWS 13/6/1
13/S
767670138.xlsx
BILL NO.14
MULTIPURPOSE HALL
A Allow for maintaining and upholding sides of excavation: clear off all fallen material, rubbish 1 ITEM
B Allow for keeping the whole of the excavation free from general water 1 ITEM
C Excavate top vegetable soil average 150mm deep and cart to spoil 0 SM
D Excavate to reduce levels not exceeding 1.50 metres deep and remove from site. 0 CM
F Excavate for foundation trench not exceeding 1.5 meters deep from reduced level. 105 CM
K 200mm Thick bed of hand packed stone base, well rolled and compacted under floor bed 218 SM
N Insecticide treatment to surfaces of hardcore, top of foundation walling, sides and bottom of 650 SM
excavation.
CONCRETE WORK
P Strip foundations 17 CM
Q Column bases 3 CM
R Stub Columns 1 CM
S Ground Beam 7 CM
V 200mm x 250mm x 75mm thick Concrete downstand for storm water channel 79 LM
FORMWORK TO
E Sides of columns 19 SM
I 1000 Gauge polythene sheet damp proof membrane : in one layer with 300mm end laps: laid on 245 SM
blinded hardcore (m/s)
WALLING
Solid concrete blockwork jointed and pointed in cement sand (1:3) mortar : with and including
hoop iron wall ties every alternative course : in
DAMP PROOF COURSE OF BITUMEN FELT TO B.S 743 Type A with 150mm laps including
cement and sand (1:3) levelling bed
TWO COATS EXTERNAL CEMENT RENDER (1:4) finished with wood float to plinth walls
COLLECTION
Total brought forward from Page 14/1/1
Total brought forward from Page 14/1/2
MULTIPURPOSE HALL
ELEMENT NO.2
R.C. FRAME
CONCRETE WORK
VIBRATED REINFORCED CONCRETE CLASS 25; 20mm AGGREGATE : in
A Ring beams 3 CM
B Beams 3 CM
C Columns 3 CM
STEEL REINFORCEMENT as described including cutting to length, bending, hoisting and
fixing and including all necessary tying wire and spacing blocks
MILD STEEL ROUND BARS TO BS 4449
FORMWORK TO:
H Sides of columns 50 SM
SUNDRIES
I 20 SWG Hoop Iron wall tie 25mm wide x 450mm long cast 75mm into concrete and built into joint 525 NO
of blockwalling.
J 75mm diameter x 2mm thick Round Hollow Section: Height 2800mm long including 700mm length 13 NO
bedded in concrete in ground : top welded with 2mm thick U-shaped mild steel cleat supporing a
60x40x3mm RHS wall plate 22000mm long: bottom welded with fixing lugs: primed with one coat
red oxide primer before fixing: includes excavation, backfill, complete
MULTIPURPOSE HALL
ELEMENT NO.3
WALLING
PRECAST CONCRETE CLASS 20; finished fair on all exposed surfaces including bedding and
jointing in cement sand (1:3) mortar
BLOCK WORK
Solid Concrete blockwork jointed and pointed in cement sand (1:3) mortar with and including
hoop iron wall ties every alternative course : in
150mm HARD BURNT CLAY VENT BRICKS to BS 3921 (3.5N/mm2 compressive strength)
bedded, jointed and pointed in cement and sand (1:4) mortar and painted in coloured cement
D Vent bricks 7 SM
DAMP PROOF COURSE OF BITUMEN FELT TO B.S 743 Type A with 150mm laps including
cement and sand (1:3) levelling bed
E 200mm Wide 61 LM
MULTIPURPOSE HALL
ELEMENT NO.4
STRUCTURAL STEELWORK
THE RATES FOR STRUCTURAL STEEL WORK SHOULD INCLUDE ALL PLATES,
STIFFENERS, BOLTS, WELDED JOINTS, ALL CONNECTIONS AND ACCESSORIES;
PAINTING AND DECORATIONS; AS PER THE ARCHITECT’S AND STRUCTURAL
ENGINEERS DRAWINGS; THE CONTRACTOR MUST STUDY THE DRAWINGS AND
ENSURE THAT HIS PRICE INCLUDES ALL ITEMS AS SHOWN ON THE DRAWINGS
SUNDRIES
G 200 x 200 x 6mm Plate: 4 No holes for 16mm diameter Anchor bolts 20 NO
I 16mm Diameter black Anchor bolts grade 4.6, 200mm Long: fixed into concrete; head, nut and 80 NO
washers
ROOF COVERING
26 Gauge pre-painted IT4 roofing sheets : fixed to Z-purlins with J-bolts : in
L 225 x 2mm thick mild steel plate fascia and barge board; welded onto structural steel; one coat red 79 LM
oxide primer
M 225 x 225 x 200 x 2mm thick galvanised steel gutter complete with and including 3mm thick angle 57 LM
brackets; one coat primer and 3 coated gloss paint
O Extra over gutter for outlet to suit 75mm diameter pipe complete with holder bars 6 NO
A Filler blocks 29 LM
COLLECTION
14/4/2
MULTIPURPOSE HALL
ELEMENT NO. 5
DOORS
TIMBER DOORS
45mm THICK SOLID CORED FOLDING TIMBER FLUSH DOOR COMPRISING of 8No.
720mm wide higed panesl (faced both sides with 6mm plywood veneer: complete with all
necessary accessories and approved door hardware set, ALL IRON MONGERY AND
ACCESSORIES to "ASSA ABLOY Manufacture or approved equal"; as per Architect's
drawings MH/SCH./07
A Folding Door D03 overall Size 5770 x 2900mm high with 8No. 720mm wide higed panels. 2 NO
D 25mm Quadrant 24 LM
E General surfaces 67 SM
STEEL DOORS
PURPOSE MADE STEEL CASEMENT DOORS : COMPRISING OF 60x40x2mm RHS frame;
40x40x2mm SHS top, bottom, intermediate and vertical rails; covered both sides with 2mm pre-
formed mild steel plates; including 300mm high vents at the top comprising 1.5mm thick mild
steel sheet cranked louvers with insect screen on coffee tray, 120mm wide bent to shape all welded
to door frame complete with and INCLUDING ALL IRON-MONGERY AND ACCESSORIES;
one coat red oxide primer; to Architect's detailed drawing MH/SCH./07
Mahogany Partition foldable door: 175 x 50mm thick Timber door framing: Complete with 50 x
25mm architraves: 45mm thick foldable/hinged: 750 x 2900mm high shutters varnished to
Architect's detailed drawing MH/SCH/07
PREPARE SURFACE AND APPLY ETCHING PRIMER; apply one coat primer, one undercoat
and two Gloss finishing coats; on metal work : to
COLLECTION
Total Carried Forward From Page 14/5/1
Total Carried Forward From Page 14/5/2
MULTIPURPOSE HALL
ELEMENT NO.6
WINDOWS
METAL WORK
PURPOSE MADE WINDOW STANDARD Steel Section for glazing with putty, permanent
ventilation comprising T-bar hood and gauze, standard transomes and mullions, stays and
fasteners, one coat red oxide etching primer : complete with and INCLUDING ALL IRON-
MONGERY AND ACCESSORIES as per Architect's detailed drawing MH/SCH./07
PURPOSE MADE STANDARD Steel burglar proofing made from 20 x 20 x 2mm SHS and 40 x
3mm flats : one coat red oxide primer as per Architect's detailed drawing
PREPARE SURFACE AND APPLY ETCHING PRIMER; apply one coat primer, one undercoat
and two Gloss finishing coats; on metal work : to
D Steel windows 65 SM
E Burglar proof 65 SM
CURTAIN RODS
F 25mm diameter spray painted galvanised iron curtain rail on and including 100mm diameter x 25 LM
25mm thick timber end brackets thrice plugged into wall
MULTIPURPOSE HALL
ELEMENT NO.7
WALL FINISHES
EXTERNAL FINISHES
PREPARE AND APPLY THREE COATS first grade weatherguard emulsion paint : externally;
on
D Rendered walls and concrete surfaces 203 SM
INTERNAL LIME PLASTER First coat of cement lime and sand (1:2:9) second coat of cement,
lime putty and sand (1:1.6) Steel trowelled smooth
PREPARE AND APPLY ONE MIST COAT AND THREE COATS silk vinyl emulsion paint
internally on:
MULTIPURPOSE HALL
ELEMENT NO.8
FLOOR FINISHES
A Floors 294 SM
CEMENT AND SAND (1:3)
B 150 x 25mm Skirting : square top and coved junction at bottom 103 LM
SPLASH APRON
C 100mm thick concrete class 20/20mm aggregate splash reinforced with and including fabric mesh 26 SM
reinforcement ref A98 as before described; including Gauge 1000 DPM and 200mm Thick
Hardcore Blinded with Stone dust and all necessary formwork.
D 200mm thick walling to sides of splash Apron with and including 450 x 150mm foundation 45 LM
concrete; finished with steel float to exposed surfaces; necessary excavation and disposal of surplus
soil.
MULTIPURPOSE HALL
ELEMENT NO.9
JOINERY FITTINGS
RATES FOR ALL JOINERY WORKS MUST INCLUDE ALL ACCESSORIES AND
FITTINGS; PAINTING AND DECORATIONS; IRONMONGERY; AS PER ARCHITECT'S
DETAILED DRAWINGS; THE CONTRACTOR MUST STUDY THE DRAWINGS AND
ENSURE THAT HIS PRICE INCLUDES ALL ITEMS REQUIRED ON THE FITTINGS
Softwood pin boards comprising of approved soft board fabric mounted onto face of walling with
and including 50 x 38mm wrot softwood timber frame all round, chamfered edges on and
including 20x 20mm hardwood bead; to Architect's detailed drawing MH/PB/08
Prepare surface and apply three coats polyurethane clear varnish in accordance with
manufacturer's instructions: on wood work: to
E 100 x 100mm in-situ concrete (mix 1:2:4) chalk rail; set into walls with 30x25mm chalk rest groove 7 LM
F Prepare and apply three coats of black bitumastic paint to blackboard surfaces 12 SM
G Apply one coat undercoat and two finishing coats of matt emulsion paint on concrete chalk rail 7 LM
surfaces not exceeding 100mm girth.
I Chairs 120 NO
TOTAL TO SUMMARY
14/9/1
MULTIPURPOSE HALL
ELEMENT NO.10
ELECTRICAL INSTALLATIONS
To be supplied, delivered to Site, installed, connected complete and commissioned in full working
condition including all the necessary fixing/mounting/terminating accessories as per
Specification and Drawings, tested and commissioned to the satisfaction of the Electrical
Engineer.
All electrical items to be suitable for 11000/415/240V power system.
All power supply cables measured under this Bills of Quantities have provisional route length
stated. Actual measurements will be done on site during evaluation.
All underground reticulation and distribution cables are to be supplied and installed c/w all
necessary fixing / clipping / supporting / glanding and termination accessories as per general
specification and type approved by the supervising Electrical Engineer
The rate for the underground cables shall cover excavation, sand-bedding, backfilling, trenching,
enclosing in PVC ducts, where necessary, and all associated builders' works. Actual
measurements shall be based on the site conditions.
All indoor cables are to recessed within the cable ducts, ceiling voids, wall fabric enclosed in
suitably sized PVC conduits neatly installed and to further Instructions from the Electrical
Engineer and/or Drawings.
All lighting fittings shall be as per Specifications and Drawings with control gear compartible
with 240V/50Hz. All lighting fittings are to be approved by the Electrical Engineer prior to
installation.
All Fire Detection and Alarm System elements are to be to fully addressable to Gent Vigilon
System Architecture, or otherwise approved.
All wiring accessories shall be as per original Legrand Specifications and Drawings (or otherwise
specificied and approved) complete with all attachments and accessories. All samples to be
approved prior to installation by the Engineer.
The entire electrical installation shall be tested for compliance in accordance to the 16th Edition
of the IEE Wiring Regulations and witnessed / approved by the Engineer
TO COLLECTION
14/10/1
A Allow a PC Sum of USHS. 3,000,000/= for Power Supply and Connection to include but not limited 1 SUM 3,000,000 3,000,000
to the following.
Power extension to the site
Earthing of the Low Voltage Systems
All associated civil works and connection costs
Meter box, Feeder pillar,Supply cables, Umeme connections, account opening & any other charges
for power connections
Making good and Builders' Works to the Satisfaction of the Engineer.
Distribution boards
B Metalcased and Lockable 100A, 6-Way Low Voltage (240) SPN MCB-type Consumer Unit for 1 NO
power supply c/w 100A DP Mains isolator, SP MCBs, Busbars, and all other accessories as per
drawings to Memshield manufacture. The rate includes accurate labelling of all loads connected
accordingly to the Board.
C 16mm sq.3-Core SC XLPE-SWA-PVC Copper cables for Power Supply connection from the 40 LM
source to the consumer unit.
LIGHTING FITTINGS:
D LED T5 1x28W, 1200mm flourescent batten light fitting with an electronic control gear as Thorn or 12 NO
equal approved
E LED Outdoor wall mounted security lights, c/w louvred and all accessories as Radiant Lighting or 2 NO
equal approved
WIRING ACCESSORIES:
F 10A/250V SP 1-Gang 1-Way white flush moulded plate switch c/w flush mounting box, and 4 NO
accessories to Legrand Synergy Modern manufacture Cat. 7310 00.
H 13A SP 2-Gang white moulded plate switched socket outlets c/w flush mounting box , as to 12 NO
CRABTREE List No. 4306/3, or approved equivalent.
I Outdoor Hard-Wired Post Eye Light Control Electric Resistor Photocell Light Sensor, as to 1 NO
LEGRAND or equivalent.
WIRING and CONDUITING:
Lighting points:
J All wiring of lighting points are to be connected complete and ready from 10A SP miniature circuit 14 NO
breakers, using 3x2.5mm sq. PVC-Insulated single core copper cables drawn in a 25mm PVC
concealed conduits, through switches, and as per drawings.
TO COLLECTION
14/10/2
A All wiring of all power points are to be connected complete and ready from 32A SP miniature 12 NO
circuit breakers, using 3x2.5mm sq. PVC-Insulated single core copper cables in ring circuit, drawn
in 25mm conduits, as per drawings.
B Conduiting from the ICT rack to each data outlet using 25mm diameter PVC conduit installed as per 4 NO
the Drawings c/w with MK box
LIGHTNING PROTECTION
All items are to be supplied and installed complete with all the required mounting, fixing,
clipping, testing including connecting accessories. All to be tested and commissioned to the
satisfaction of the Electrical Engineer.
Supply, install, connect and set to work the following, all as described in the specifications and
drawings
E 25mm x 3mm copper square test clamp, as to FURSE Cat.No. CT 105, or approved equivalent. 2 NO
F 2000mm x 15mm air rod, as to FURSE Cat. No. RA 240 c/w multiple point, as to FURSE Cat. No. 2 NO
RA 600, air terminal base, as to FURSE Cat. No. SD 105, and ridge saddle, as to FURSE Cat. No.
SD 115, or approved equivalent.
H 1200mm x 20mm solid copper earth rod, as to FURSE Cat.No. RC 015, complete with driving stud 2 NO
and coupler, and accessories.
COLLECTION
Total Carried Forward From Page 14/10/1
Total Carried Forward From Page 14/10/2
Total Carried Forward From Page 14/10/3
TO SUMMARY
14/10/3
BILL NO.14
MULTIPURPOSE HALL
SUMMARY
1 SUBSTRUCTURES 14/1/2
3 WALLING 14/3/1
5 DOORS 14/5/2
6 WINDOWS 14/6/1
14/S
767670138.xlsx
BILL NO.15
SPORTS FIELD
BILL NO.15
SPORTS FIELD
SUMMARY
15/S