Professional Documents
Culture Documents
PUHY P400TKA - BS - 208 220 230V - Submittal en
PUHY P400TKA - BS - 208 220 230V - Submittal en
FEATURES
• INVERTER-driven compressor
• Air-source, heat pump system
• Long line lengths - for details see Engineering Manual
• Connects to CITY MULTI® indoor units
• Controlled via CITY MULTI® Controls Network
UNIT OPTION
ACCESSORIES
□ Low Ambient Kit (for details see Low Ambient Kit Submittal)
□ Base Pan Heater Kit (for details see Base Pan Heater Kit Submittal)
Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC
SPECIFICATIONS: PUHY-P400TKA (-BS)
Cooling Capacity
*1 kW 45
(Nominal) kcal/h 40,000
*1 Btu/h 153,500
Heating Capacity
*2 kW 45
(Nominal) kcal/h 40,000
*2 Btu/h 153,500
MCA A 59.2
Max. Refrigerant Line Length (Between ODU & IDU Ft. 541
Case heater kW -
Lubricant MEL32
Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC
SPECIFICATIONS: PUHY-P400TKA (-BS)
External finish Pre-coated galvanized steel sheets (+powder coating for -BS type)<MUNSELL 5Y
8/1 or similar>
High pressure protection High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Fan motor -
Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC
DIMENSIONS: PUHY-P400TKA (-BS)
<Accessories> Unit: mm
●Connecting pipe
<Gas> ·Elbow (ID28.58×OD28.58)····P350,P400,P450 1pc.
600=150×4
<Liquid> ·Pipe (ID15.88×OD15.88)····P350,P400,P450 1pc.
·Pipe reducer (ID15.88×OD12.7)····P350,P400 1pc.
740
Note1.Please refer to the next page for information
regarding necessary spacing around the
150
4×5-ø4.6 Hole unit and foundation work.
(Make hole at the plastic fan guard 2.At brazing of pipes,wrap the refrigerant service valve
for snow hood attachment) with wet cloth and keep the temperature of
<Snow hood attachment hole> 19.5 1181 19.5 refrigerant service valve under 120°C.
70
1220 Connecting pipe specifications
Discharge air Top view Diameter
Model Refrigerant pipe *1 Service valve
303
Liquid Gas Liquid Gas
Control box PUHY-P350TKA(-BS) ø12.7 Brazed
ø12.7 Brazed
PUHY-P400TKA(-BS) (ø15.88 Brazed) ø28.58 Brazed ø15.88 ø28.58
Intake *2
Intake
Intake air PUHY-P450TKA(-BS) ø15.88 Brazed
air
air
*1 Connect by using the connecting pipes (for bottom piping and front piping)
1650
that are supplied.
*2 Indicates dimensions and connection specifications in the case the unit is
1347
Service
Refrigerant service valve panel used in combination with other outdoor units.
<liquid> NO. Usage Specifications
Refrigerant service valve 1
<gas> 4 1 Front through hole 102 × 72 Knockout hole
7
88
72 For pipes
2 Bottom through hole 150 × 94 Knockout hole
54
238
172
84
227
121
144
196
(Mounting pitch)
5
94
(740)
681
2 Refrigerant service
6 valve <gas>
Refrigerant service
valve <liquid>
80 1060 80
29.5
(Mounting pitch)
Bottom view
Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC