LOCATION U.A.E (ABU DHABI) CLIENT XYZ CONSULTANT ABC 126.00 Area or Sun Gain or Factor Item Btu/Hour Watts (U) ROOM HEAT Q= U*A*ΔT ROOM SENSIBLE HEAT Solar Gain - Glass Area ΔT U Glass - N SqFt x x 0.00 Glass - NE SqFt x x 0.00 Glass - E SqFt x x 0.00 Glass - SE 15.50 SqFt x 13.00 x 0.30 60.45 Glass - S SqFt x x 0.00 Glass - SW 11.62 SqFt x 100.00 x 0.30 348.60 Glass - W SqFt x x 0.00 Glass - NW SqFt x x 0.00 Skylight SqFt x x 0.00 Solar & Transmission Gain - Walls & Roof Wall - N SqFt x F x 0.00 Wall - NE SqFt x F x 0.00 Wall - E SqFt x F x 0.00 Wall - SE 138.33 SqFt x 37.50 F x 0.05 259.37 Wall - S SqFt x F x 0.00 Wall - SW 128.35 SqFt x 35.50 F x 0.05 227.82 Wall - W SqFt x F x 0.00 Wall - NW SqFt x F x 0.00 Roof 300.00 SqFt x 45.50 F x 0.05 614.25 Transmission Gain - Except Walls & Roof All Glass 27.10 SqFt x 36.00 F x 0.30 292.68 Partition 46.15 SqFt x 31.00 F x 0.50 715.33 Ceiling SqFt x F x 0.00 Floor 300.00 SqFt x 31.00 F x 0.27 2,511.00 INFILTRATION AND BY PASSED AIR Infiltration CFM x 36.00 T.Diff x 1.08 0.00 Outside Air 28.00 CFM x 36.00 x 130.64 Internal Heat People 2.00 Nos. x 230.00 Btu/Hour Per Person 460.00 Lighting 300.00 SqFt x 1.00 W/SqFt x 3.41 1,023.00 Equipments 1.00 200.00 Watts x 3.41 682.00 Power kW/Hp x 0.00 Sub Total 7,325.13 Factor 5-15% 1,098.77 Effective Room Sensible Heat 8,423.90 1.00 ROOM LATENT HEAT Infiltration 0.00 CFM x 6.00 Gr/Lb x 0.68 0.00 Outside Air 28.00 CFM x 6.00 Gr/Lb x BFx0.68 13.71 People 2.00 Nos. x 120.00 Btu/Hour Per Person 240.00 Sub Total 253.71 Factor 2.5 - 5% 12.69 Effective Room Latent Heat 266.39 2.00 EFFECTIVE ROOM TOTAL HEAT 8,690.30 OUTSIDE AIR HEAT Sensible 28.00 CFM x 36.00 F(TD) x CF x 1.08 958.00 3.00 Latent 28.00 CFM x 6.00 Gr/Lb x CF x 0.68 100.53 4.00 OUTSIDE AIR TOTAL HEAT 1,058.53 GRAND SUB-TOTAL HEAT 9,748.83 Factor 1 - 3% 292.46 GRAND TOTAL HEAT 10,041.30 TMBH 10.04 TKW 2.91 TSMBH 9,381.90 TSKW 2,720.75 TONS=GRAND TOTAL HEAT/12000 0.84 INPUT VALUES ARE TO BE GIVEN IN BLUE COLOR BOXES ONLY FLOOR Ground Floor SPACE REFERENCE R-01, Flat-1, Bedroom,Residential (ABU DHABI) AREA ( SqFt) (WxH) 300.00 Falce Ceiling Height (Ft) 9.40 Volume (CuFt) 2,820.00 Estimate for Summer Design Conditions DB (°F) WB (°F) RH (%) HR (Gr/Lb) Ambient(Out Side) 111.00 75.00 19.00 74.00 Room (InDoor) 75.00 63.00 50.00 68.00 Difference Δ 36.00 12.00 31.00 6.00
By Pass Factor (BF) = 0.12
Contact Factor (CF = 1 - BF) = 0.88 CFM Ventilation CFM Per Person 5.00 No = 2.00 = 10.00 CFM Per SqFt 0.06 Sqft x 300.00 = 18.00 Air Change Per Hour (CFM) = CFM Cu.ft 2,820.00 x 0.00 x1/60 = 0.00 CFM Infiltration Swinging x cfm/door = 0.00 Revolving Doors (People) x cfm/door = 0.00 Open Doors x 1.00 cfm/door = 0.00 Crack (feet) x cfm/ft = 0.00 0.00 Supply CFM from Machine Effective Room Sensible Heat Factor = Effective Room Sensible Heat/Eff Room Total Heat = 0.97 Apparatus Dew Point (ADP) Indicated ADP (F) = Selected ADP (F) = 54.60 Dehumidified Rise (Room DB - ADP) x CF = 17.95 DEHUMIDIFIED AIR QUANTITY Effective Room Sensible Heat = 434.49 CFM Dehumidified Rise x 1.08 = 204.21 L/s TOTAL HEAT CAPACITY Grand Total Heat = 0.84 TR