MP-02 - Isolate For Maintenance

You might also like

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 1

MUD PUMP (MP)

JOB: ISOLATE MUD PUMP FOR MAINTENANCE Sr. mechanic : Mostafa Saher Date :12/11/2010 at 15:00 MP-02

POTENTIAL HAZARDS
TOOLS /
Conditions or Actions Which RECOMMENDED SAFE PROCEDURES
KEY JOB PROCESS STEPS MATERIALS S/P RISK
Could Cause an Injury / Affect Personal Protective Devices Special Clothing Procedures
USED
Health

1. Lock tag out mud pump None  Electric shock 4B HM  Ask electrician to lock out from SCR.
from VFD  Pump not locked out  Install safety pin in DC motor local switch
 Do not use wet gloves

2. Isolate the pump by closing None  Back strain 1C L  Ask Driller to stop other pump if running.
the discharge valves

3. Bleed off trapped pressure None  slip, tripping, falling 1C L  Clean working area
 Ensure of good housekeeping

4. Lock out & line up the None  Electric shock 4B HM  Ask electrician to remove the lock
pump after repair  Back strain 1C L  Make sure other pump is stopped before opening
the valve

HSE : Mostafa Mahmoud STP : Gamal Elsaid

767776080.doc Page 1 of 1

You might also like