3334 PCN4+ & Main Display Release Rev 2

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

**US Only**

PCN4+ & Main Display is Released

Related Equipment:
• M18666A001 Pump Control Node (PCN)4+
• M18830A001 Main Display
• M18923A001 Display Bus Cable

Overview:
Beginning 08/25/2022 most new Encore® units leaving Greensboro will be equipped with new
variants of the PCN and Main Display. Some unit options may require the previous board set,
those units will be equipped with LON-based electronics. Replacement boards for units produced
prior to 08/25/2022 continue to utilize the previous LON-bus node set. The PCN4+ uses the same
Laptop Tool for software loading or downloading information as previous boards.
Troubleshooting and error codes for the new board set are the same. There are no additional
error codes, jump jacks or LEDs. These new boards are not backwards compatible with the
previous LON bus board set. These boards will be released outside of the US at a date TBD. Please
download and review the related documentation for detailed information.

Related Documentation:
• MDE-3804 Encore/Eclipse Start-Up and Service Manual Part I
• MDE-3921 Laptop Tool Software User Guide
• PT-1936 Encore 300, Encore 500/500 S, Encore 700 S, Eclipse® Recommended Spare Parts
• PT-1937 Encore & Eclipse Recommended Spare Parts

Further Information:
The new board set utilizes a Display (RS485) bus instead of the previous LON bus. Redundant
storage is held in two locations, the PCN4+ and A-side Main Display. Therefore single-sided units
will no longer require a Door Node on the unused B-side. The PCN4+ is the primary source of
redundant storage, while the Main Display is the secondary source.
IMPORTANT INFORMATION
In the event of PCN4+ replacement the replacement must be performed correctly
using the instructions detailed in MDE-3804, otherwise calibration and configuration will
be lost. Reconfiguring and recalibrating units due to improper PCN replacement
will not be covered under warranty.

Initial Release: 09/14/2022 SB #3334 REV 2: 10/26/2022

Page 1 of 7
M18666A001 PCN 4+:

The PCN4+ is functionally the same as previous PCNs and must be paired with a M18830 Main
Display. For single sided units only the A side Main Display is required. Most LEDs and jumpers
are the same, as is programming, error codes and software loading procedures and information
retrieval via the Laptop Tool. As this PCN is not LON-based there are no neuron status LEDs.

Jumper Label Function


JP1 PIC PGRM Must not install
JP2 LON Service Must not install
JP3 DBG Enable Must not install
JP4 LON Program Must not install
JP5 Coldstart Coldstart
JP6 BRD Address Must not install
JP7 WD Enable Must be installed
JP8 Battery Disconnect Must not install
JP10 PLD DB Must not install
JP11 None Must not install

Initial Release: 09/14/2022 SB #3334 REV 2: 10/26/2022

Page 2 of 7
M18830A001 Main Display:

The Main Display is functionally the same as previous 6-digit Door Nodes, though it must be
paired with a M18666 PCN4+. Most LEDs and jumpers are the same, as is programming. As this
Main Display is not LON-based there are no neuron status LEDs. There is no loadable software on
this node. The OPT jumper is not used on the Main Display for grades 5 or 6, PPU addressing is
performed solely on the PPUs. UHF Master/satellite combo units are not considered true single
sided units for this application only, the B side will still require a Main Display. PCN programming
will remain the same in Command Code 92.

Function
Jumper Purpose
Installed Uninstalled
JP3 (A0) Side Control Side B Side A
JP4 (A1) Side Control Do not install Not used in North America
JP5 OPT Do not install None
JP6 Display Test Display Test Normal Operation

PPU Addressing:
If converting a unit, the PPUs may need to be re-addressed since the OPT jumper on the Main
Display is not used. Please refer to the table below. PPUs on models NL0-NL6, NF2 & NF4 will
likely need to be re-addressed.

Grade J11 J12 J13


1 Out Out Out
2 In Out Out
3 Out In Out
4 In In Out
5 Out Out In
6 In Out In

Initial Release: 09/14/2022 SB #3334 REV 2: 10/26/2022

Page 3 of 7
Cabling & Connections:

The new board set uses Display bus cables such as the M18923AXXX. These cables feature
latching connectors and are ribbon style cables. Peripherals are connected the same as previous
platforms with the same connector designations.

Note: For further details see the related documents on GOLD

Software:

The PCN4+ is shipped with V05.0.14, which is the functional equivalent of the LON based PCN
version V04.1.30. Support for the Display bus was added, and LON based support was removed.
Later versions will be announced in the usual manner.

WARNING!
PCN4+ V05.X.XX is only compatible with the PCN4+. If a version other than V05.X.X
is loaded the unit will not function until a JP5 coldstart is performed, followed by
loading a compatible V05.X.XX or higher. If V05.X.XX is loaded onto a LON based PCN,
the unit will not function until a JP5 coldstart is performed, followed by loading a
compatible V04.X.XX or lower. Redundant storage may not be retained.

The Main Display will currently be shipped with version V05.0.03, which is the functional
equivalent of Door Node V03.0.05. Enhancements to support the PCN4+ and Main Display were
added, and LON based support was removed.

V05.0.14 is available through the standard pump software download process using the modifier
“PCN4PLUS”. Main Display V05.0.03 is not field loadable and is not available.

Initial Release: 09/14/2022 SB #3334 REV 2: 10/26/2022

Page 4 of 7
Retrofit Kits & Spares:

While there is no need to upgrade from existing equipment upgrade kits will be available.

Part Number Name


M16785K001 Kit, Encore, PCN4+ & M/V Display, Sgl Side
M16785K002 Kit, Encore, PCN4+ & M/V Display

Reverse Compatibility:

If a LON-based unit is converted, both A and B sides must be converted. Only one bus can be used
within a unit at a time. While it should not be necessary to convert existing field units unless
installing kits, please note that these new boards are compatible with most but not all previous
pump electronic peripherals.

Compatible:

• PPUs M12893, M13048, M13051, M18802, M18902 (10-pin ribbon style


connections)
• Satellite Indicator M12895, M14416
Not Compatible:

• LON-based CRIND (CCN)


• Non-standard Pulsers
• M05838AXXX PPU assemblies
• USB/LON functionality
• Units with dual main display windows such as the E300/E500.

SOFTWARE REMINDER
PCN4+ V05.X.XX is only compatible with the PCN4+. If a version other than V05.X.X
is loaded the unit will not function until a JP5 coldstart is performed, followed by
loading a compatible V05.X.XX or higher. If V05.X.XX is loaded onto a LON based PCN,
the unit will not function until a JP5 coldstart is performed, followed by loading a
compatible V04.X.XX or lower. Redundant storage may not be retained.

Initial Release: 09/14/2022 SB #3334 REV 2: 10/26/2022

Page 5 of 7
PCN4+ Replacement Process:

Please follow this process when replacing a PCN4+ with a PCN4+. This is applicable only to
Display bus equipped PCNs, it is not possible to use a LON based PCN in place of a PCN4+.

IMPORTANT INFORMATION
The below process must be followed in the exact sequence shown in the steps below.
If this process is not followed, there is a risk of losing calibration and all regulatory
data. Reconfiguring and recalibrating units due to improper PCN replacement
will not be covered under warranty.

1) If applicable or possible, record the Pump Totals. They can be re-entered later in the process.
2) Isolate the 2-wire from the POS.
3) Remove power from the dispenser.
4) Unseal the security/W&M switch.
5) Disconnect all cables from the PCN4+ and remove it from the mounting bracket.
6) Remove the battery from the new PCN4+ and set it aside on a non-conductive surface.
7) Wait at least 30 seconds, then reinstall the battery.
8) Attach the new PCN4+ to the mounting bracket.
9) Re-connect all cables disconnected previously.
10) Turn ON/OPEN the security/W&M switch by sliding it forward.
11) Restore power to the dispenser.
12) Wait for the PCN4+ to boot up fully (zeros showing on the main display along with error 5056
code flashing on the Grade 1 PPU).
13) Remove then restore power on the dispenser.
14) Wait for the PCN4+ to boot up fully.
15) Turn OFF/CLOSE the security/W&M switch by sliding it backward.
16) Enter Pump Totals if applicable.
17) Re-connect the 2-wire.
18) Test the dispenser for proper operation and communication.
19) Seal the security/W&M switch or if necessary, notify your local W&M office that the seal has
been removed and needs to be replaced.

Initial Release: 09/14/2022 SB #3334 REV 2: 10/26/2022

Page 6 of 7
Further Information:

After reviewing the related documentation if there are any further technical questions, please
email TAC at SSE.Dispenser.Requests@Gilbarco.com. Neither TAC nor Field Engineers will be able
to assist with queries regarding availability, pricing, or any non-technical question.

Related Documentation:
• MDE-3804 Encore/Eclipse Start-Up and Service Manual Part I
• MDE-3921 Laptop Tool Software User Guide
• PT-1936 Encore 300, Encore 500/500 S, Encore 700 S, Eclipse® Recommended Spare Parts
• PT-1937 Encore & Eclipse Recommended Spare Parts

IMPORTANT INFORMATION
This bulletin does not serve as authorization to perform any site visits or warranty service.

Initial Release: 09/14/2022 SB #3334 REV 2: 10/26/2022

Page 7 of 7